Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Dec 2024
Closing Date29 Jan 2025
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Summary

Repair/ Maint And Servicing Of Geysers, Ceiling Fan, Exhaust Fans, Wall Mounted Fans And Repair/maint Of Cooling Appliances Water Cooler, Desert Cooler, Deep Freezer, Refrigerator, Spilt/window/ Tower/ Castle Ac With Other Connected Works Under G

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of complete exhaust fan 300 mm sweep unscrewing the body parts of the exhaust fan taking out ball bearing, gun metal bush etc. Incl removing the fan from its original position ,overhauling and varnishing heating as per manufactures design and directed. Re-assembling complete exhaust fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, incl refixing the same in its original position complete all as specified and design to give designed air delivery including greasing, oiling etc complete all as specified and directed.

250

-

-

... More
Description all as per Sl. item no. 4.00 above but exhaust fan of size 450 mm sweep.

113

-

-

... More
Taking down and dismantling of complete pedestrial fan / cabin fan 400 mm sweep unscrewing the body parts of the fan taking out ball bearing gun metal bush etc. Removing of unserviceable ball bearing, gun metal bush, overhauling and varnishing heating as per manufactures design and directed. Re-assembling complete fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed.

63

-

-

... More
Taking down and dismantling of complete PVC exhaust fan 200/250/300 mm sweep by unscrewing the body parts of the fan taking out ball bearing , gun metal bush etc. Removing of unserviceable ball bearing, gun metal bush, overhauling and varnishing heating as per manufactures design and directed. Re-assembling complete fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed. Notes for Sl item no. 1 to 8 :- (a) Spare parts found unserviceable / defective will be measured and paid separately under relevant item as supply only. (b) The element for fixing of new spare parts are deemed to be included in quoted unit rate of above items.

300

-

-

... More
Supply only condenser of capacity 2.5 to 3.15 MFD, 230 volts, 50 Hz AC confirming to IS 1709 complete.

650

-

-

... More
Supply only condenser of capacity 4 MFD, 230 volts, 50 Hz AC confirming to IS 1709 complete.

200

-

-

... More
Supply only Rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200 mm / 1400 mm sweep.

400

-

-

... More
Supply only Gun metal bush 15 mm size as per sample.

500

-

-

... More
Supply only Split Pin of size 25 mm long.

400

-

-

... More
Supply only Ball bearing of size 6201 / 6202 / 6203 as per sample.

680

-

-

... More
Supply only in repair MS down rod 'medium grade' 15mm dia of length 0.75 mtr complete with making split holes, cut or threads at both end of pipe as required for hanging of ceiling fan incl. painting of rod with two coats of synthetic enamel white paint over one coat of primer all as directed.

100

-

-

... More
All as per Sl. item no. 14.00 above but of length 1.0 mtr to 1.20 mtr as per requirement at site

150

-

-

... More
Supply only 'U' shape shackle clamp assembly incl checknut, bolts, screws, washer, lock nut, rubber reel etc. and connecting complete all as directed.

50

-

-

... More
Supply only fan hook made out of steel bar as per sample

40

-

-

... More
Supply only PVC insulated flexible wire twin core twisted copper conductor of size 0.75 Sqmm (24 / 0.20) complete.

500

-

-

... More
Repair / maintenance and servicing of non functioining geysers of 25 ltrs capacity due to any defect like air lock, water leakage in pipe line joints,non functioning of any parts, checking electric connections and making good the loose electric connection and pipe line leakage etc.and making the geysers functional complete

350

-

-

... More
Taking down carefully storage type water heater (geysers) of 25 litres capacity for servicing after disconnecting existing water supply and electric connection by unscrewing / cutting of holding bolts / nuts from walls and opening the tank for repair including taking out inner assembly and scraping scale deposite on the surfcae of assembly, cleaning and washing and re-assembling after repairs and fixing the same in its original position and making necessary water supply and electric connection and testing complete all as specified and directed. Note:- The quoted unit rate is deemed to be included taking down of geyser from original position and refixing after repair incl the cost of nut and bolt if any required at site incl necessary cost of rubber gasket in any size complete all as specified and as directed.

110

-

-

... More
Taking down carefully storage type water heater (geysers) of 50 litres capacity for servicing after disconnecting existing water supply and electric connection by unscrewing / cutting of holding bolts / nuts from walls and opening the tank for repair including taking out inner assembly and scraping scale deposite on the surfcae of assembly, cleaning and washing and re-assembling after repairs and fixing the same in its original position and making necessary water supply and electric connection and testing complete all as specified and directed. Note:- The quoted unit rate is deemed to be included taking down of geyser from original position and refixing after repair incl the cost of nut and bolt if any required at site. Notes for Sl item no.19 to 21 :- (a) Spare parts found unserviceable / defective will be measured and paid separately under relevant item as supply only. (b) The rate for fixing of new spare parts are deemed to be included in quoted unit rate of above items.

4

-

-

... More
Supply only copper sheathed and nickel plated heating element 1.5 kW with gasket (ISI marked) push/ threaded type suitable for horizontal or vertical type water storage type water heater (Geysers) all as specified and directed.

300

-

-

... More
All as per Sl. item no. 22.00 above but heating element 2 kW complete all as specifed and directed .Make - Dasspass, Ditz, Racold, Empire, Havells/ veenus

220

-

-

... More
Supply only copper sheathed and nickel plated heating element 1.5 kW with gasket (ISI marked) round / cup type suitable for horizontal or vertical type water storage type water heater (Geysers) all as specified and directed.

300

-

-

... More
Supply only thermostat, suitable for any make & type of geyser 50/ 25 litres capacity horizontal or vertical type complete all as specified and directed. Note for Item No 22 to 25 : Model Nos of each item shall be vary as per site requirement and shall be be procured accordingly.

450

-

-

... More
Supply only indicating lamp for geysers of any type make & capacity all as specified and directed.

100

-

-

... More
S&F fill glass wool for geysers including taking down old glass wool complete all as specified & directed.

5

-

-

... More
Supply only rubber gasket round / flat suitable for inlet and outlet assembly of any capacity geyser as per sample.

50

-

-

... More
Supply only mild steel expansion fastners 10 mm dia and 100 mm long to walls by drilling complete with washers etc. and making good disturbed surfaces to match with the existing all as specified and directed.

200

-

-

... More
S&F in repairs PVC connections 15 mm size with PTMT nuts, of length 450 mm complete all as specified and directed.

500

-

-

... More
M&L for spray painting to existing Geysers of any capacity 25 Ltrs with supper enameld heat resistant paint of approved colour complete with scrapping old surfaces, filling cavities and writting MES no. complete all as specified and directed.

100

-

-

... More
S&F fan blde 1200mm sweep complete all as specified and directed.

130

-

-

... More
S&F Metal clad plug and socket 20 Amps, 230 V, 50 Hz all as specified and directed.

50

-

-

... More
Taking down / dismantling and removing inner stainless steel/ copper tank of geyser (any make), 25 litres capacity and rectification of leakage by welding/ brazing with suitable metal including all necessary denting etc and re-assembling the same including making connections complete all as specified and directed.

60

-

-

... More
S&F metal plug and socket DB, two pin and earth plug, 240 volts and including one 20 Amp MCB SP, C-Curve & including taking down of old/unsv concealed metal box replacing with new, making good cement work and paint complete all as specified and directed.

62

-

-

... More
S&F in repairs PVC insulated and PVC sheathed 3 core copper conductor flexible round cable size 2.5 sqmm complete all as specified and directed.

600

-

-

... More
S&F in repairs Chromium plated, Concealed stop cock short body, cast copper alloy, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle, screwed externally both ends for unions etc.

15

-

-

... More
S&F in repairs Chromium plated fancy long body Bib taps, cast copper alloy, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified.

15

-

-

... More
S&F in repairs prepainted inspection plate rounded in two pieces made out of 22 gauge MS sheet suitable for 25 Litres and with fixing space for indicating lamp of any type geyser and any make and capacity including fixing screws complete all as specified and directed.

5

-

-

... More
S&F screwed type Bronze vertical check valve 15 mm bore by cutting and threading of GI pipe including necessary fittings like sockets, unions, elbow, nipples etc. complete all as specified and directed.

10

-

-

... More
S&F screwed type Bronze air release valve 15 mm bore by cutting and threading of GI pipeincluding necessary fittings like sockets, unions, elbow, nipples etc. complete all as specified and directed.

50

-

-

... More
Supply & fix new air release valve 15 mm bore for geyser as per existing type including taking down old unserviceable air release valve’s complete all as specified and directed.

20

-

-

... More
S&F wall mounted fan 400 mm sweep, single phase 230 volts including flexible copper cable for electric connections complete all as specified and as directed.

5

-

-

... More
S&F air freshner fan 200 mm sweep, 900 RPM, PVC body AC single phase 230 volt, with inbuilt louver complete all as specified and directed.

25

-

-

... More
S&F air freshner fan 250 mm sweep, 900 RPM, PVC body AC single phase 230 volt, with inbuilt louver complete all as specified and directed.

20

-

-

... More
S&F air freshner fan 300 mm sweep, 900 RPM, PVC body AC single phase 230 volt, with inbuilt louver complete all as specified and directed.

20

-

-

... More
S&F in repairs modular surface mounted plastic boxes 06 module for fixing of switch socket combination 6 Amps (02 Nos) ISI marked complete all as specified and as directed.

50

-

-

... More
S&F in repairs plug top 15 Amps complete all as specified and as directed.

125

-

-

... More
Description all as per Sl. item no. 48.00 here in above but of 5 Amps.

100

-

-

... More
S&F in replacement of PVC casing n caping where ever necessary of size 20 mm size incl screws, wooden/plastic packing complete all as specified and as directed.

400

-

-

... More
Taking down old bottom plate of geysers 25 liters capacity & supply & fix new bottom plates of same sizes and shape complete all as specified & directed.

200

-

-

... More
Description all as per item No. 51.00 above but of capacity 50 Ltrs complete all as specified and directed by Engineer-in-charge

50

-

-

... More
Supply and install PVC Geyser water heater outer cover (Geyser body ) suitable for 25 ltr including top and bottom cover plate comple with all nuts, bolts, washer,glasswool for insulation complete all as specified and directed by Engineer-in-charge

52

-

-

... More
Supply and install PVC Geyser water heater outer cover (Geyser body) suitable for 50 ltr including top and bottom cover plate comple with all nuts , bolts, washer,glasswool for insulation complete all as specified and directed by Engineer-in-charge

4

-

-

... More
Supply in replacement for exhaust fan Louver of size 300mm, complete all as specified and directed by Engineer-in -charge

85

-

-

... More
Supply in replacement for exhaust fan Louver of size 380mm, complete all as specified and directed by Engineer-in -charge

70

-

-

... More
S&F in replacement of inner water storage copper tank of suitable for 25 ltrs capacity complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
S&F in replacement of inner water storage stainless steel tank of suitable for 25 ltrs capacity complete all as specified and directed by Engineer-in-Charge.

45

-

-

... More
S&F in replacement of inner water storage copper tank of suitable for 50 ltrs capacity complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement of inner water storage stainless steel tank of suitable for 50 ltrs capacity complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement of geyser ' U' assembly for 25/ 50 ltrs capacity water heaterincluding as per existing make replacement of rubber seal and nuts and bolts completeall as specified and directed by Engineer in Charge.

210

-

-

... More
S&F in replacement sheet metal enclosures DB Double door type 8 way SPN 240 volt including 200 Amps rated bus bar with neutral link complete all as specified and directed by Engineer in Charge.

25

-

-

... More
S&F in replacement sheet metal enclosures DB Double door type 4 way SPN 240 volt including 200 Amps rated bus bar with neutral link complete all as specified and directed by Engineer in Charge.

14

-

-

... More
S&F sheet metal enclosures DB Double door distribution type, 04 way, TPN DB , IP43, 415V & suitable for MCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer, complete all as specified and directed by Engineer in Charge.

10

-

-

... More
S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal including writting the MES Number with synthetic enamel paint complete all as specified and as directed.

15

-

-

... More
M&L for servicing of both (indoor & outdoor) unit of ACs of windows/ split type/ Cassette/Tower type of any capacity by cleaning coils with the use of c shine solution, removing internal dust and cleaning of filters by using water pump jet and air blower, oiling & greasing wherever required and checking of all other parts and proper cooling complete all as specified and directed . Note:-(i) All tools and machinery required deemed to be in quoted rates including servicing kit for indoor and outdoor unit with air compressor and servicing pump for removal of any foreign material from indoor/outdoor unit all as specified and directed by Engr-in-charge. (ii) All minor parts reqd for satisactory performance of the AC must be replaced and shall be deemed to be included in the above item rate.

75

-

-

... More
M&L for servicing of both (indoor & outdoor) unit of Tower type ACs of capacity 3.0 TR by cleaning coils with the use of c shine solution, removing internal dust and cleaning of filters by using water pump jet and air blower, oiling & greasing wherever required and checking of all other parts and proper cooling complete all as specified and directed . Note:-(i) All tools and machinery required deemed to be in quoted rates including servicing kit for indoor and outdoor unit with air compressor and servicing pump for removal of any foreign material from indoor/outdoor unit all as specified and directed by Engr-in-charge. (ii) All minor parts reqd for satisactory performance of the AC must be replaced and shall be deemed to be included in the above item rate.

12

-

-

... More
M&L for servicing of both (indoor & outdoor) unit of split type ACs of split type/ Cassette of any capacity (fitted on outside wall at height of 25-40 ft and above) by cleaning coils with the use of c shine solution, removing internal dust and cleaning of filters by using water pump jet and air blower, oiling & greasing wherever required and checking of all other parts and proper cooling complete all as specified and directed . Note:-(i) All tools and machinery required deemed to be in quoted rates including servicing kit for indoor and outdoor unit with air compressor and servicing pump for removal of any foreign material from indoor/outdoor unit all as specified and directed by Engr-in-charge. (ii) All minor parts reqd for satisactory performance of the AC must be replaced and shall be deemed to be included in the above item rate.

27

-

-

... More
M&L for taking down the indoor and outdoor and refixing it back to its original position or any other place after servicing of both (indoor & outdoor) unit of split type ACs . Note:-(i) All tools and machinery required for taking down and refixing deemed to be in quoted rates (ii) servicing of AC Shal be measured separately. (iii) spare parts copper tube and cable wire shall be measured separately.

8

-

-

... More
Leakage testing of complete AC unit of any description and of any capacity after making all necessary arrangements in any position including vacuumising & pressure testing with and including dry Nitrogen Gas (N2) after necessary brazing and soldering etc complete all as specified and directed..

18

-

-

... More
M&L for writing of SM/MES No etc on window AC/Split AC/Refrigerator/Water cooler/Deep freezer/Desert cooler with the help of stencil with synthetic enamel paint colour complete all as specified and directed.

25

-

-

... More
Supply and fixing of copper tube suitable for split ACs of capacity 1.5/2 TR of the following sizes including dismantling of old U/S copper tube and insulation of the new copper tube

-

-

-

... More
1/4 " inch

45

-

-

... More
1/2 " inch

45

-

-

... More
Supply & fixing in repair of 20mm dia transparent PVC heavy duty flexible pipe ISI marked with and including necessary clamps & nails for fixing the drain pipe for drainage of swetting water of indoor unit of split type ACs complete all as specified and directed.

150

-

-

... More
Supply and fixed in replacement Blower/ Condenser fan blade (PVC) assembly of existing make & size suitable for window type ACs/Split ACs of capacity 1.5/ 2.0TR complete all as specified and directed.

3

-

-

... More
Supply and fixed in replacement Blower/ Condenser fan blade (PVC) assembly of existing make & size suitable for split/Cassette/Tower type of capacity 3.0/ 4.0TR complete all as specified and directed.

3

-

-

... More
Supply and fixing in replacement of sealed reciprocating/sealed rotary/hermatically seal unit type compressor for AC 1.5 TR of existing size and make and capacity at site including necessary brazing, soldering, pressure testing, refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of sealed reciprocating/sealed rotary/hermatically seal unit type compressor for AC 2.0 TR of existing size and make and capacity at site including necessary brazing, soldering, pressure testing, refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed.

5

-

-

... More
Supply and fixing in replacement of sealed reciprocating/sealed rotary/hermatically seal unit type compressor for split/Cassette/Tower type AC 3.0/4.0 TR of existing size and make and capacity at site including necessary brazing, soldering, pressure testing, refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed.

2

-

-

... More
Supply only refrigerant gas R-134 ( Non CFC) / R-407C in returnable sealed cylinder all as specified and directed by EIC.

65

-

-

... More
Supply only refrigerant gas R-22/410/32 in returnable sealed cylinder all as specified and directed by EIC.

75

-

-

... More
Supply and fixing of new air filters of size 13.3 inch * 8.6 inch or of suitable for existing model of 1.5/2 TR Split/Window AC including taking down the old U/s air filters.

12

-

-

... More
Supply and fixing of new air filters of size of suitable for existing model of 3.0/4.0 TR Split/Window AC including taking down the old U/s air filters.

3

-

-

... More
Supply and fixing in replacement of printed control board panel (PCB) of existing make/ model suitable for window Acs/Split Acs of capacity 1.5/2.0 TR complete all as specified and directed.

12

-

-

... More
Supply and fixing in replacement of printed control board panel (PCB) of existing make/ model suitable for split/Cassette/Tower type AC 3.0/4.0 TR complete all as specified and directed.

3

-

-

... More
Supply and fixing of capillary tube/thermal expansion valve suitable for Split Acs/Window Acs /water cooler/refrigerator /deep freezer of existing make/model as reqd at site complete all as specified and directed.

7

-

-

... More
Supply and fixing in replacement of battery operated cordless remote control of existing make/ model suitable for split type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.

12

-

-

... More
Supply and fixed in replacement of, PVC front grills of existing make, shape & size suitable for window type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.

3

-

-

... More
Supply and fixed in replacement, air sweep louvers with motor complete set suitable for window type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.

4

-

-

... More
Supply and fixed in replacement, PVC sheathed, 3 core copper conductor flexible cable of following size with thimbles of suitable size & shape complete all as specified and directed.

-

-

-

... More
1.5 sqmm 3 core

100

-

-

... More
M&L for preparation of existing outdoor unit of split type Acs any size including steel structure and base of structure complete all as specified & directed.

6

-

-

... More
M&L for insulation of copper pipes (refrigerant gas pipes) with insulating materials of approved quality for better cooling effects of split type ACs or heat resistance/ protection of copper pipes from atmosphere including sealing/ covering the same with packing tape complete all as specified and directed.

30

-

-

... More
Taking down & shifting of existing split type air conditioner of capacity 1.5/2.0TR to new location as directed including re-installation/ re-fixing the same at new location i.e outdoor and indoor units at new locations and making all necessary electric/ charging pipe line connections, commissioning and testing on completion and making good the disturbed surfaces of wall/ floor as per existing including comprising of the following accessories/ works complete all as specified and directed:- Note:- The rate quoted above will include all the necessary tools and spare parts required for its reinstallation including gas charging after carrying out leakage test and new drain pipe & copper pipe with insulation as required at site.

12

-

-

... More
Disconnecting the existing refrigerators /Deep freezer of any capacity and transporting the same from site/AGE E/M Yard to workshop and back after necessary repair/ repair of old unserviceable or wornout accessories/ parts in the workshop and re-fixing/ re-connecting the same in existing position and testing on completion for efficient cooling complete all as specified and directed for the following capacities:- Note:- Gas charging and repair of spare parts of refrigerators shall be measured and paid separately under respective items of BOQ/ Sch'A' as "material and labour" complete.

20

-

-

... More
Supply and fixed in repair, compressors of refrigerators/Deep freezer of following models including cutting the suction and discharge line for removing of un-serviceable compressors and fixing of new compressors by jointing suction & discharge line, welding, brazing/ soldering, vaccumising and charging of gas with required quantity of R-134(a) gas to achieve the efficient cooling & smooth functioning and testing on completion complete all as specified and directed:- Note:- Gas charging of refrigerators shall be measured and paid separately under respective items of BOQ/ Sch'A' as "material and labour" complete.

-

-

-

... More
Compressor of make Kirloskar/Tecumseh/LG for refrigerator refrigerators/Deep freezer of 120 to 230 Ltrs capacity omplete all as specified and directed.

2

-

-

... More
Compressor of make Kirloskar/Tecumseh/LG for refrigerator refrigerators/Deep freezer of 240 to 500 Ltrs capacity omplete all as specified and directed.

2

-

-

... More
Supply and fixed in repair, PVC stand of refrigerators 100 ltr to 420 ltr of best quality suitable for refrigerators of OFF sizes complete all as specified and directed.

8

-

-

... More
Labour for disconnecting, dismantling and taking out the water coolers of any description, any make and in any position having capacity 40 to 150 Ltrs, cleaning and servicing of the water cooler with using C shine solution, taking out or removing all unserviceable/ defective parts of water cooler and fixing of new spare parts/ items i.e wiring kit, compressor, condenser, condenser fan motor, relay, capicitors, thermostat, overload relay and including necessary brazing, vaccumising, gas charging, reassembling/ reinstallation of water cooler, making connections and testing complete all specified and directed. Note:- repair of unserviceable/ defective/ wornout parts/ spares of water coolers shall be measured and paid under respective items as ''Supply & Fixed''

35

-

-

... More
Supply & Fixed'' of new compressor for water cooler in repair suitable for 40/80 Ltrs capacity water cooler of any make and model complete all as specified and directed.

3

-

-

... More
Supply & Fixed'' of new compressor for water cooler in repair suitable for 120/150/160 Ltrs capacity water coolers compete all as specified and directed.

2

-

-

... More
Supply & Fixed'' in repair of unserviceable PVC connection 15mm bore of 450 mm long with brass coupling with washers at both ends and connection to water cooler and water main complete all as specified and directed.Make-Prayagraj/Jyoti

15

-

-

... More
Supply & Fixed'' in repair of unserviceable 15mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe or brass ferrule complete all as specified & directed. (Note-Min weight should not be less than 142 gms)

20

-

-

... More
M&L in repair of MS bracket/base for fixing of condenser fan motor with 02 Nos rubber bush and 02 Nos GI clamp with & including 04 Nos MS nuts and bolts and washers suitable for any type & capacity condenser fan motor of water coolers complete all as directed.

2

-

-

... More
'Supply & Fixed'' in repair of unserviceable aluminium blade for condensing fan motor of water coolers of any model/ size as per existing complete all as specified and directed.

8

-

-

... More
Disconnecting and taking out the defective/ non-functional desert cooler of any description and in any position/ installed at any floor . Strip opening of desert cooler, cleaning, servicing, oiling & greasing,painting of entire body etc of desert cooler, taking out and removing unserviceable/ defective parts and including replacement of unserviceable spares/ parts i.e condenser, internal wiring, re-assembling & testing of the desert cooler complete all as specified and directed. Note:- Replacement/repair of defective/ wornout spares/ parts of desert cooler i.e condenser & internal wiring shall be measured and paid separately under respective items as ''S&F in repair''.

35

-

-

... More
S&F in replacement of unserviceable wood wool pads (set of three) in repair including PVC pipe pieces 03 Nos of required length & dia for connection of water distribution PVC elbows 03 Nos of desert coolers of (Approx) complete all as specified and directed.

35

-

-

... More
S&F in replacement of unserviceable submersible pump for desert cooler in repair, heavy duty, single phase of power 20 to 150 watts and head 2 m complete all as specified and directed.

15

-

-

... More
S&F of electric motor of desert coolers with copper winding heavy duty, 380mm sweep, 1400 RPM with all connected items reqd for its installation complete all as specified and directed.

15

-

-

... More
S&F of metal fan blade set for desert coolers for medium and heavy duty coolers of any size complete all as specified and directed.

20

-

-

... More
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 3500 cum per hour ,tank capacity not less than 70 litre.collapsible louvers to prevent dust and insects,ice chamber,3 speed control fan of size 406mm with motor 1350 RPM,auto fill system,water level indicator and,thermal overload protector complete all as specified and as directed

8

-

-

... More
M&L for removing of perished body of desert cooler over all approx size of 0.750x0.750x0.910 mtr or as per exixting size from existing site and replace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size Approximet 0.750x0.750x0.230mtr and also having electric control panel consisting two nos 5amp switch, one rotary speed regulator switch complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally complete all as specified and directed by EIC.

15

-

-

... More
S&F''of detachable type perforated side panel in repair made out 22 gauge PGI sheet of desert coolers of size 90cmX90cmX75cm or existing size complete all as specified and directed by Engr -in-Charge.

15

-

-

... More
S&F of front grills desert coolers in repair, size 18"x18" of each made out of 22 gauge sheet as per sample and including piano type switch complete all as specified and directed.

15

-

-

... More
S&F 'C' series MCB SP, 6 to 32 Amps, 240 volts, 50Hz , 10kA complete all as specified & directed.

20

-

-

... More
S&F 'C' series MCB SPN, 40 to 63 Amps, 240 volts, 50Hz , 10kA complete all as specified & directed.

3

-

-

... More
Taking out existing defective/unserviceable rusted body of outdoor unit and dismantleing of all the spare parts compressor, fan motor , fan blade and renewal with new out door unit body suitable for split type 1.5 TR complete with copper tube condensor heat exchanger and fins and refixing of compressor, fan motor and fan blade of old oudoor unit to new body with all connected items reqd for its installation complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Taking out existing defective/unserviceable rusted body of outdoor unit and dismantleing of all the spare parts compressor, fan motor , fan blade and renewal with new out door unit body suitable for split type 2.0 TR complete with copper tube condensor heat exchanger and fins and refixing of compressor, fan motor and fan blade of old oudoor unit to new body with all connected items reqd for its installation complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Taking out existing defective/unserviceable body of indoor unit and dismantleing of all the spare parts PCB , blower motor , blower and all conected parts and renewal with new indoor unit body suitable for split type 1.5 TR complete with all connected items i.e copper tube cooling coil,filter and refixng of blower, blower motor and PCB of old uns indoor body to new body with all connected items reqd for its installation complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Taking out existing defective/unserviceable body of indoor unit and dismantleing of all the spare parts PCB , blower motor , blower and all conected parts and renewal with new indoor unit body suitable for split type 2.0 TR complete with all connected items i.e copper tube cooling coil,filter and refixng of blower, blower motor and PCB of old uns indoor body to new body with all connected items reqd for its installation complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Disconnecting of the unserviceable voltage stabilizers capacity upto 5 KVA from the site and removing to workshop for repair and re-fixing/testing/commissioning at the original position after rewinding / replacement of parts/spares to the extent required /reassembling complete all as specified and directed. Note :- Spares/parts shall be measured and paid seperately under respective items of BOQ as " Supply only".

20

-

-

... More
Supply and fixing of voltage stablizers of 5 KVA capacity including its installation and connecting with the existing machinery.

15

-

-

... More
Supply only main transformer with super enameled copper wire proper insulated upto 5 KVA capacity for volatage stabilizer complete as specified and directed.

12

-

-

... More
Supply only volt meter 0 to 300 volts complete all as specified and directed

10

-

-

... More
S&F in replacement of main PCB for voltage stabilizer 0.5 KVA to 5.0 KVA of approved make complete all as specified and directed.

12

-

-

... More
S&F in replacement of auxiliary transformer for the 0.5 KVA to 5 KVA capacity stablizer of approved make complete all as specified and directed.

12

-

-

... More
M&L for rewiring (wiring kit) of windowsplit/Cassette/Tower type ACs,water cooler,deep freezeer,refrigerator with using best quality PVC insulated copper conductor cable including thimbles sleaves of suitable size & shape complete all as specified and directed.

30

-

-

... More
Supply and fixed in replacement, fins and tube type air cooled copper condensers of following capacity of any make complete all as specified and directed including taking down the old U/S fins:-

-

-

-

... More
Split type ACs of capacity 1.5TR/2 TR

4

-

-

... More
Window type ACs of capacity 1.5TR

2

-

-

... More
Refrigerator of capacity 120-200 ltrs.

2

-

-

... More
Refrigerator of capacity 320 ltrs

2

-

-

... More
Deep freezers of capacity 200 to 500 ltrs.

2

-

-

... More
Water cooler of capacity 40 to 150 ltrs

5

-

-

... More
Supply and fixing of Running/Starting aluminium body with lugs terminal capacitors of the following capacities for Acs/water coolers/ Refrigerators/ Deepfreezers/desert coolers etc.all as specified and as directed by Engr-in-Charge

-

-

-

... More
Upto05-30 mfd

10

-

-

... More
Upto 30-80 mfd

35

-

-

... More
Upto 80-120 mfd

11

-

-

... More
Supply and fixing of starting relay of approved make including dismantling old one suitable for the following

-

-

-

... More
Window type/Split type AC 1.5/2 Ton capacity

12

-

-

... More
Refrigerator of 120 to 320 liters capacity.

10

-

-

... More
Deep freezers of 200 to 500 ltrs capacity.

3

-

-

... More
Water coolers 40 to 150 ltrs cooling capacity

10

-

-

... More
Supply and replace thermostats of approved make including dismantling old one of the following:-

-

-

-

... More
Refrigerator of 120 to 320 liters capacity.

12

-

-

... More
Deep freezers of 200 to 500 ltrs capacity.

10

-

-

... More
Water coolers 40 to 150 ltrs cooling capacity

5

-

-

... More
Supply and replace overload protector relay of approved make including dismantling old one of the following:-

-

-

-

... More
Window type/Split type AC 1.5/2 Ton capacity

8

-

-

... More
Refrigerator of 120 to 320 liters capacity.

8

-

-

... More
Deep freezers of 200 to 500 ltrs capacity.

6

-

-

... More
Water coolers 40 to 150 ltrs cooling capacity

6

-

-

... More
Supply and replace starting motor of approved make including dismantling old one of the following:-

-

-

-

... More
Outdoor motor suitable for split ac/window ac 1.5/2 TR.

6

-

-

... More
Indoor blower motor suitable for split ac/window ac 1.5/2 TR.

6

-

-

... More
Swing motor with flapper for split ac/window ac 1.5/2 TR.

5

-

-

... More
Motor for water cooler 40 to 80 ltr/hr.

4

-

-

... More
Motor for water cooler 80 to 150 ltr/hr.

4

-

-

... More
Motor for double door refrigerator 280 to 320 ltr/hr.

2

-

-

... More
Motor for deep freezer 200 to 500 ltr.

1

-

-

... More
Supply and replace cooling coil complete made out of copper tube of approved make complete all as specified and as directed by Engineer-in-Charge of :-

-

-

-

... More
Window type/Split type room air conditioners of capacity 1.5/2 Ton cap.

2

-

-

... More
Water coolers 80/120/150 ltrs capacity.

2

-

-

... More
Refrigerator of upto 320 ltrs capacity.

1

-

-

... More
Deep freezers of 200 to 500 ltrs capacity.

1

-

-

... More
Supply & fixing ( in repairs) Drain pump for cassette type Ac's capacities of 4 TR, 220-240V, 50/60Hz all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for Repair overhauling of exahaust system installed at 'B' Mess including check of all vents, leakage & water pipe lines etc complete all as specified and directed.

1

-

-

... More
Taking out the old unserviceable winding and cleaning the slots of motor capacity 20 HP and rewinding the same with PVC insulated copper wire of existing gauge ,weight, size etc complete including all insulations, varnishing, heating etc and making all connections & testing to make it functional complete all as directed .

1

-

-

... More
M&L for Repair/Replacement of unservicable star delta motor starter suitable for 20 Hp motor complete all as specified and directed

1

-

-

... More
Repair/Maints/Servicing of cold storage room ( plus temperature and minus temperature )of 'B mess' due to loose electrical connections,no power supply, gas leakage or any other minor default / defects, identifying and rectifying the defects and making the cold storage functional by replacement/ renewal, complete all as specified and directed by Engr-in-Charge. Note:- (i) The minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips,PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.

1

-

-

... More
Supply and fixing in replacement of sealed reciprocating/sealed rotary/hermatically seal unit type compressor for cold room of existing size and make and capacity at site including necessary brazing, soldering, pressure testing, refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed.

1

-

-

... More
Servicing of pump & motor of capacity 5 Hp to 7.5 Hp complete all as specified & diected.

2

-

-

... More
Taking out the old unserviceable winding and cleaning the slots of centrifugal pump motor, 5 HP to 7.5 HP and rewinding the same with PVC insulated copper wire of existing gauge ,weight, size etc complete including all insulations, varnishing, heating etc and making all connections & testing to make it functional complete all as directed .

2

-

-

... More
Desclaing of condenser unit by using cleaning solution, HCL, Sulphuric Acid, shoftner chemical, circulating pump, descaling brush, shoue, hand gloves, flange gaset, rubber insertation gasket etc. of capacity 37.5 TRX02 chiller complete all as specified & diected.

1

-

-

... More
Desclaing of condenser unit by using cleaning solution, HCL, Sulphuric Acid, shoftner chemical, circulating pump, descaling brush, shoue, hand gloves, flange gaset, rubber insertation gasket etc. of capacity 11.5TRX02 chiller complete all as specified & diected.

1

-

-

... More
Repair/servicing of hot water generator of capacity 54kw including replacement of unserviceable element complete all as specified & diected.

1

-

-

... More
Repair/servicing of hot water generator of capacity 22kw including replacement of unserviceable element complete all as specified & diected.

1

-

-

... More
Repair and servicing of scroll type panel of capacity 37.5 TR cleaning all contactors and removing damaged electric cable and rewiring with the same gauge new copper wires and make functional complete all as specified and directed.

1

-

-

... More
Repair and servicing of scroll type panel of capacity 11.5 TR cleaning all contactors and removing damaged electric cable and rewiring with the same gauge new copper wires and make functional complete all as specified and directed.

1

-

-

... More
Maintenence/Servicing and attending complaint from in respect of non functioning of Air Conditioner plant of 37.5 x 2 TR capacity and 11.5 x 2 TR capacity due to loose electrical connections,no power supply, gas leakage or any other minor default / defects, identifying and rectifying the defects and making the Plant functional and checking of all meters and make them functional complete all as specified and directed by Engr-in-Charge. Note:- (i)Parts/ accessories/articles/gas renewed only shall be measured and paid separately under appropriate items).However minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips,PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.

2

-

-

... More
Supply and fixing in replacement of sealed reciprocating/sealed rotary/hermatically seal unit type compressor of capacity 12.5 TR for AC plant of existing make and capacity at site including necessary brazing, soldering, pressure testing, refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed.

1

-

-

... More
Repair/servicing of cooling tower tank of central Ac plant of 37.5TRX2 with removing of small leakage including foot valve and cleaning of fins by chemical complete all as specified & diected.

1

-

-

... More
Repair/servicing of cooling tower tank of central Ac plant of 11.5TRX2 with removing of small leakage including foot valve and cleaning of fins by chemical complete all as specified & diected.

2

-

-

... More
Servicing/ cleaning of AHU filter of suitable size complete all as specified & diected. Note :- (i) The contractor will collect the complaint slip at 9 am from the AGE E/M office and will ensure that the unserviceable ACs are rectified within 24 hours of receiving of complaints. (ii) If contractor fails to make ACs serviceable even within 48 hrs time then panel recovery of 500/- per day for each complaint will be made from contrator dues. (iii) The contractor will detail one rerigeration mechanicand one helper for AC and summer cooling appliances on a daily basis (iv) No absentee of refrigeration mechanic and helper will be permissible beyond one day and subjected to a recovery of 500 per day from contractor dues.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.