Military Engineer Services Tender
... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 34,99,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_688006_1Bid Award Id
ViewTender No
GE/RND/T-70/GWL/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Motor cut of limit switch
1
-
-
... More
Closing coil 110 VDC
4
-
-
... More
Tripping coil 110 VDC
4
-
-
... More
Segment gear Assembly (Full Teeth-Big )
1
-
-
... More
Tripping Half shaft
1
-
-
... More
Trip Catch with linkage assembly
1
-
-
... More
Spring charging motor assembly 230 VAC
1
-
-
... More
Motor Gear Box Assembly.
1
-
-
... More
Closing Half shaft
1
-
-
... More
Auxiliary switch Assembly.
1
-
-
... More
Ratchet wheel with key & Set of pawls with pin
1
-
-
... More
Motor contractor
1
-
-
... More
Limit switch
1
-
-
... More
Taking down the existing IDMT relays (two nos over current and one no earth falult relays fixed in 33 KV HT Panels for primary and secondary injection and calibration of all the relays and setting the relay tripping timings in advance to the feeding sub-station to ensure pockets vise installation of various relays in position with complete control and test and trial Note :- (i) The primary injection kit shall be arranged by the contractor. (ii) The DC supply for relay testing shall be arranged by the contractor. (iii) The contractors shall prepare the relay adjustment and tripping timing chart in follow up fashion and submit it to the Engr-in-charge.
4
-
-
... More
Supply & Fixing in Replacement Current transformer 3 Core outdoor type 33 KV rate 100 /50/5A complete all as specied and directed.
3
-
-
... More
Disconnecting and taking out old unserviceable Ammeter of any description and in any position and supply, fixing, connecting, testing and commissioning of new digital Ammeter size as per site requirement suitable for panel, 11 KV HT VCB complete all as specied and directed.
3
-
-
... More
Disconnecting and taking out existing unserviceable Potential transformer (PT) of any description and in any position and supply, installation, commissioning and testing of 11 KV single phase out door oil cooled potential transformer complete all as specied and directed.
2
-
-
... More
Disconnecting & taking out non functional VCB/OCB of any description and any make of rating 11 KV, 400 Amps to 800 Amps dismantling/opening of the VCB for servicing/over hauling taking out and removing unserviceable/defective parts including cleaning and servicing greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after over hauling /servicing and its testing complete all as specified and directed. Note: - The quoted rates of the contractor includes for replacment of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BoQ as supply only)
18
-
-
... More
Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commissioning and testing of cast resin type 11 KV current transformer having ratio of 200+100\5+5 A having protection core class 5P 10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking capacity of 13.1 KV for 1.0 second complete all as specied and directed.
3
-
-
... More
Supply and fixing in repair battery 12v 150 AH Lead acid low maintanance complete all as specified and directed
2
-
-
... More
Supply only following spare parts for 11 KV VCB 400/630 Amps capacity of any make : (Note (i) fixing and testing element of following item is deemed to be included under BoQ item No 7.00 here-in-before(ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item)
-
-
-
... More
Isolating Contacts .
6
-
-
... More
Closing shaft
2
-
-
... More
Tripping shaft
2
-
-
... More
Big Gear Assembly
2
-
-
... More
Small Gear Assembly
2
-
-
... More
Motor Cut off limit switch
2
-
-
... More
Micro switch assembly
2
-
-
... More
Breaker Control switch
2
-
-
... More
Spring charging Motor 230 VAC
2
-
-
... More
Segment Gear Assembly
2
-
-
... More
Trips catch assembly
2
-
-
... More
Bus bar support insulator
6
-
-
... More
Epoxy Bussing insulator for 11kv
6
-
-
... More
ON/OFF push butten Assembly
2
-
-
... More
Charge Dischasge indicator assembly
10
-
-
... More
Indicating lamps Blue 230 VAC spring charging
10
-
-
... More
Indicating lamps Red,Yellow,110 VAC
10
-
-
... More
Indicating lamps Blue 110 VAC
10
-
-
... More
CGI 14N Numerical Relay
2
-
-
... More
Closing / Trip coil
2
-
-
... More
Spout busing upper & lower 11kv 400 to 800A with CC parts
6
-
-
... More
CRC Spry for lubricant
6
-
-
... More
Vacuum Interceptor
6
-
-
... More
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 200 Amps of 11 KV and supply and fix new air break switch gang operated Triple pole (Insulator ) mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating type switch complete all as specied and directed.
8
-
-
... More
Supply & Fixing in Replacement of DO fuse outdoor type upto ratio 200 Amps of 11 KV complete all as specied and directed.
3
-
-
... More
M&L in replacement lightening arrestor of 11 KV, 10KA and maximum voltage of 36KV for with solid earthed natural system comprising of Metal oxide elements suitable for ACSR Conductor alongwith the insulating base structural work complete all as specied and directed.
2
-
-
... More
M&L in replacement lightening arrestor of 33 KV, 10KA and maximum voltage of 36KV for with solid earthed natural system comprising of Metal oxide elements suitable for ACSR Conductor alongwith the insulating base structural work complete all as specied and directed.
1
-
-
... More
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 400 Amps of 33 KV and supply and fix new air break switch gang operated Triple pole mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating type switch complete all as specied and directed.
2
-
-
... More
Supply & Fixing in Replacement of DO fuse outdoor type upto ratio 200 Amps of 33 KV complete all as specied and directed.
1
-
-
... More
Supply and fixing in replacement of sealed lead acid battery 12V, 42 AH complete all as specified and directed
7
-
-
... More
M & L in Replacement jointing and testing for outdoor type heat shrinkable end termination joint suitable for 11 KV, XLPE insulated cable of 95 to 120 Sqmm 3 core.complete material and labour including cutting the faulty outdoor end termination joint of any description and in any position complete all as specied and directed.
6
-
-
... More
M & L in Replacement jointing and testing for Indoor type heat shrinkable end termination joint suitable for 11 KV, XLPE insulated cable of 95 to 120 Sqmm 3 core including cutting the faulty outdoor end termination joint of any description and in any position complete all as specied and directed.
6
-
-
... More
M & L in Replacemente Jointing and testing of Straight through heat shrinkable joint suitable for 11 KV, XLPE/PVC insulated cable size of 95 to 120 sqmm including cutting the faulty straight through of any description and in any position complete all as specied and directed.
2
-
-
... More
M & L in replacemente Jointing and testing of heat shrinkable end termination joint suitable for 33 KV, XLPE/PVC insulated cable size of 120 sqmm including cutting the faulty end termination of any description and in any position.
1
-
-
... More
Removal of existing broken/damaged PCC duct of any description and Material & labour for duct cover of pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) of size 430mm x 900mm x 60mm thick, cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways with 02 Nos 12mm dia MS round bar handle complete all as specied and directed.
60
-
-
... More
Material and labour for 40 to 63 mm graded stone aggregate of black trap / granite / basalts spread in layers not exceeding 25cm thick, & well rammed to a true surface removal of old stone aggregate cleaning screening cum and relaying at same or another location complete all as specified & directed
30
-
-
... More
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32x6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge.
12
-
-
... More
Disconnecting, taking out and removing old existing unserviceable underground, HT 11 KV cable of any description and in any position complete including taking down protection pipe etc complete all as specied and directed.
150
-
-
... More
Supply, laying , jointing & testing of undergraund HT cable 11 KV (Earthed) , aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) (amended till date) having following cross sectional area 95 Sqmm 3 core complete all as specied and directed.
150
-
-
... More
Demolition for cement concrete in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified and directed
1
-
-
... More
M & L for 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) complete all as specified and directed .
10
-
-
... More
M & L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded aggregate) as in floor finishing even and smooth without using extra cement and making impression of expanded metal, while concrete is green and making good as per existing surface etc complete all as specified and directed .
10
-
-
... More
M & L in Replacement, GI water tubing, 100 mm bore,light grade as in sleeving etc cable protaction laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.
18
-
-
... More
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers
131
-
-
... More
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
34
-
-
... More
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed.
97
-
-
... More
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. Note Punned thickness shall be measured.
72.1
-
-
... More
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed.
220
-
-
... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique of 100 mm dia suitable for 0.4 mpa working pressure complete all as specied and directed.
12
-
-
... More
Disconnecting and taking down old unserviceable control cable any size and any description and supply, fixing, testing and commissioning of LT 1100 volts 2.5 Sqmm 4 core copper conductor armoured cable connecting the cable in position properly by providing suitable new copper lugs GI bolts & Nuts washers etc complete all as specified and directed.
260
-
-
... More
Disconnecting and taking down old unserviceable control cable any size any description and supply, fixing, testing and commissioning of LT 1100 volts 2.5 Sqmm 8 core copper conductor armoured cable connecting the cable in position properly by providing suitable new copper lugs GI bolts & Nuts washers etc complete all as specified anddirected.
220
-
-
... More
Disconnecting and taking down old unserviceable control cable any size any description and supply, fixing, testingand commissioning of LT 1100 volts 2.5 Sqmm 12 core copper conductor armoured cable connecting the cable in positioning properly by providing suitable new copper lugs GI bolts & Nuts washers etc complete all as specified anddirected.
260
-
-
... More
supply and installation in repair automatic DC unintrupted power supply system for 24/30 v DC with following specifications (1) AC input voltage 230V RANGE 180V TO 270 V (2) AC input frequency ( nominal) 50 HZ (3) DC output voltage (nominal for load) 24 to 30 VDC (4) DC OUTPUT FLOAT VOLTAGE FOR BATTERY 40.5V (5)DC output boost voltage for battery 43.2v (6) DC out put current for load( nominal) 8A (7) DCoutput current for (nominal) for battery 15A. PROTECTION (1) AC input supply - fuse (2) DC out put Short circuit supply/overload - fully protected (3) Reverse battery protection - yes. ELECTRICAL SPECIFICATION (1) AC input supply/mains available - green led (2) DC output - green led (3) fLOTE CHARGED MODE - GREEN LED ( 4) BOOST CHARGED MODE - YELLOW (5)Battery discharge/low - red led (6) Battery reverse polarity - red led
1
-
-
... More
S&F automatic power factor control relay of 12 stage operating Voltage - 230 V AC and current Input - 1A or 5 A,Steps- 12 relay outputs ,Supply Voltage - 1Ph 415 VAC (-40% to +20% ),Measurement Voltage : 3Ph 3 wire 415 VAC (-40% to +20% ) ,Operating temperature : 0 to 70 º C , of M/S EPCOS CAT NO.BR6000,PFC CONTROLLER-BR-6000-R-12- Material Code - B44066R6012R 230N-1 or equivalent including testing, connecting, commissioning in such a way to avoid "controller hunting" complete as in repairs as specified and as directed having following features:- (a) Microcontroller logic for measurement. (b) User friendly operation. (c) Control mode : binary , unequal and user defined. (d) Multifunctional LCD display. (e) Single CT sensing for balanced loads. (f) Individual harmonic measurement upto 15th order. (g) Three CT sensing for unbalanced load. (h) Dual target Power Factor setting useful for utility and DG mode operation, (j) Automatic synchronization. (k) Separate 3 CT monitoring of healthiness of Capacitor within Panel. (l) Data logging. (m) RS 232 in front and RS 232/485 switchable connection at rear. (n) Step operation indication on LCD display plus LED which facilitates viewing from a distance. (o) Unique facility of including 'Fixed Capacitor Bank' for purpose of Transformer compensation. This can be set such that the controller doesn't ‘see' this capacitor. (p) Unique external temperature sensing by PT100. (q) Settable alarm facility - undervoltage,overvoltage and so on. (r) Settable auxiliary outputs - 2 Nos for Alarm, etc. (s) Dynamic Power Factor Controller (Transistorised) available in16 steps without PT100 facility available. (u) EMI/EMC type tested.
2
-
-
... More
M&L for repair the Unserviceable APFC panel by servicing and renewals of burnt / U/s Power/Control wiring and spare parts to achieve Power Factor upto 0.99 for the capacity upto 75 KVAR complete all as specifies and directed.
3
-
-
... More
All as per ser item No 42.00 here-in-before but for capacity 100 to 150 KVAR.
4
-
-
... More
All as per ser item No 42.00 here-in-before but for capacity 175 KVAR
1
-
-
... More
Note for item 42 to 44 (i) Rate quoted by contractor deemed to be included for renewal of burnt copper wiring, copper lugs and other necessary screws,nuts and bolts etc. (ii) The spare parts to be replaced shall be measured and paid separately as per respective items of the BoQ. (iii) Penalty will charged @ Rs 100.00/day/panel till the completion of the work to contractor in case of average PF falling below 099.
-
-
-
... More
S & F in repair 10 KVAR power factor correction capacitor Heavy Duty Long life rectangular box type, self standing units of modular construction with sheet metal enclosure, self healing property, PU resin as impregnant with safety device in the form of pressure sensitive (over pressure) mechanical interrupter including wire for use on 440V (AC), 3 phase, 50 Hz,(Series B32459) AC conformance to Standards IEC 60831-1 2/96, IS 13340 with MPP film with heavy edge including testing, commisioning as in repairs complete all as specified and directed.
4
-
-
... More
All as per ser item No 46.00 here-in-before but of capacity 15 kVAr .
6
-
-
... More
All as per ser item No 46.00 here-in-before but of capacity 20 kVAr .
6
-
-
... More
All as per ser item No 46.00 here-in-before but of capacity 25 kVAr
6
-
-
... More
S&F in repair power capacitor duty contactor 240 volts suitable for 10 kVAR including testing connecting commissioning complete all as specified and directed.
6
-
-
... More
All as per ser item No 50.00 here-in-before but for 15 kVAr .
4
-
-
... More
All as per ser item No 50.00 here-in-before but for 20 kVAr .
6
-
-
... More
All as per ser item No 50.00 here-in-before but for 25 kVAr
6
-
-
... More
S&F in repair HRC fuse link,Type HG,offset, size F1, 2 - 16 amps cap base/holders make Havells or equivalent of Schneider/ Siemens/ L&T complete all as specified and directed.
6
-
-
... More
S&F in repair HRC fuse link,Type HG,offset, size A2, 16 To 32 amps cap , Fuse base/holders. Make : Havells or equivalent of Schneider/ Siemens/ L&T complete all as specified and directed
3
-
-
... More
S&F in repair HRC fuse,Type HQ,offset, size A3, 35 to 63 amps cap ,Fuse base/holders. Make : Havells or equivalent of Schneider/ Siemens / L&T complete all as specified and directed.
3
-
-
... More
S&F in repair HRC fuse,Type HQ,offset, size A4, 125 amps cap ,Fuse base/holders. Make : Havells or equivalent of Schneider/ Siemens / L&T complete all as specified and directed.
3
-
-
... More
S&F in repair in repairs Fuse holder A2 type, suitable for 4 to 32 Amps bolted fuse links . Make L & T or equivalent of Schneider/ Siemens / HPL complete all as specified and directed.
3
-
-
... More
S&F in repair Fuse holder A3 type, suitable for 35 to 63 Amps bolted fuse links of Make L & T or equivalent of Schneider/ Siemens / HPL complete all as specified and directed.
3
-
-
... More
S&F in repairs Fuse holder A4 type, suitable for 80 to 125 Amps bolted fuse links of Make L & T or equivalent of Schneider/ Siemens / HPL complete as in repairs all as specified and directed.
3
-
-
... More
S&F in repair Solid state relay of 55 to 60 Amp swithing the capacitor bank complete all as specified and directed.
3
-
-
... More
S&F in repairs thyrestor controller relay 75 amp complete all as specified and directed.
8
-
-
... More
S&F in repairs thyrestor controller relay 125 amp complete all as specified and directed.
8
-
-
... More
M&L for control wiring of the panel with 440V 10 Sq mm PVC insulated stranded single core copper conductor cable (FR-LS) conforming to IS for power circuit, the wire ends will be copper ferruled including disconnecting and removing the unserviceable wire complete connecting testing all as specified and directed.
90
-
-
... More
All as per ser item No 64.00 here-in-before but 2.5 Sqmm cable.
90
-
-
... More
S&F digital Ammeter in replacement for measuring alternating current of range : 0 - 450 A flush type 96x96MM size complete all as specied and directed.
6
-
-
... More
S&F digital Voltmeter in replacement for measuring alternating current voltage of range : Range 0-500 V flush type 96x96MM size complete all as specied and directed.
6
-
-
... More
S&F in replacement voltmeter/ammeter selector switches suitable for Voltage between Phases with OFF, 16 Amps complete all as specied and directed.
4
-
-
... More
S&F in replacement indoor resin cast ring type current transformer of ratio 800/5 Amps, accuracy - 15VA, Class - 5P10 complete all as specied and directed.
3
-
-
... More
Painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthetic enamel paint of approved shade over a coat of red oxide primer complete all as specified abd specified.
100
-
-
... More
M & L for sheet metal work for repair to electric panel doors, bus bar cover and accessories mounting supports for alignment with front door with 2 mm thick MS sheet duly painted with super enameled paint over one coat of red oxide primer including necessary cutting, welding and fixing complete all as specied and directed.
40
-
-
... More
M & L in repairs Earthing complete with galvanished earth plate electrode of size 600 x 600 x 6.00 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip 32 x 4mm as earthing lead by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil,PCC work in 1:3:6 pit and RCC 1:2:4 type B-1 pit cover reinforced with 6 mm dia ms bar 75 mm c/c 10 mm dia handle, charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 40mm dia from earth pit to main board including necessary pit cover complete all as specified and as directed.
5
-
-
... More
S&F in repairs, Breaker control switch (Trip-Neutral-close), TNC with 2NO + 2NC SPR RTN complete all as specified and as directed.
4
-
-
... More
S&F in replacement Rotary Type A/M Switch, 1 Pole, 2 Way with Off, Make - KAYCEE//L&T/SIEMENS. complete all as specified and as directed.
3
-
-
... More
S&F Flush head Push Button Green/Red colour with 1 NC Block, Make - L&T of equivalent as approved by GE complete all as specified and as directed.
9
-
-
... More
S&F in replacement multi function meter having LCD Display,96 x 96 sq.mm Flush mounted case, accuracy class 1.0 capable of measuring Instantaneous, Average, Maximum and Total Current from 50A to 6000A and voltage from 120V AC to 300V AC Phase to Neutral, Phase to Phase Voltage, Instantaneous, Average, Maximum and Total Active Power KW, Instantaneous, Average, Maximum and Total Reactive Power KVAR, Instantaneous, Average, Maximum and Total Apparent Power KVA, Instantaneous and Total Power Factor, Frequency complete all as specified and as directed.
1
-
-
... More
S&F in repair instrument Cooling fan , 3000 RPM, 230 Volts 50 Hz complete within the panel including cutting of a suitable sized hole on the panel body and wiring with 1.5 Sqmm copper conductor cable and MCB SPN 6 Amps all complete complete all as specified and as directed.
10
-
-
... More
S&F in renewals capacitor cooling Exhaust fan 230 volts complete complete all as specified and as directed.
10
-
-
... More
S&F in replacement LED indicator - R/Y/B/G 240 V AC complete all as specified and as directed.
16
-
-
... More
S&F MCB TP 63 Amps 10 KA 'C' Series 415 Volts all as specified .
10
-
-
... More
S&F in repairs MCCB 125 Amps 3 pole, 415 V, breaking capacity 16 KA & connected accessories complete as specified and as directed
4
-
-
... More
S&F in repairs MCCB 160 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 25 KA including spreader terminals & connected accessories complete as specified and as directed.
4
-
-
... More
S&F in repairs MCCB 200 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 36 KA including spreader terminals & connected accessories complete as specified & directed.
2
-
-
... More
S&F in repairs MCCB 250 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 36 KA including spreader terminals & connected accessories complete as specified & directed..
2
-
-
... More
S&F in repairs MCCB 350 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 36 KA including spreader terminals & connected accessories complete as specified & directed.
2
-
-
... More
S&F in repairs MCCB 400 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA including spreader terminals & connected accessories complete as specified & directed.
2
-
-
... More
S&F in repairs MCCB 630 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 50 KA including spreader terminals & connected accessories complete as specified & directed.
1
-
-
... More
S&F in repairs ON load changeover with phase Barriers & Handle with door interlock kit is integral part of the Changeover Switch ,with SS enclosure 400 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells /L&T / Schnieder / Siemens
1
-
-
... More
M&L for repairing / servicing the existing U/S Air Circuit Breaker of 800 Amp capacity L&T/Crompton make for proper functioning (tripping) on overload and earthfault by replacing the wornout parts, tighting all cable ends incuding replacing the U/S lugs etc, cleaning the dust by blower all as directed by Engineer-in-Charge. Note:- (i) Wornout/Us parts of ACB will be paid & measured separately under respective item of schedule. (ii) The servicing of ACBs will be done only throgh authrised rep of OEM.
2
-
-
... More
Supply only Lockable trip push button (LTPB) kit of 800 Amps Air circuit breaker .
2
-
-
... More
Supply only contact spring.
4
-
-
... More
Supply only moving contact.
4
-
-
... More
Supply only Door interlock
2
-
-
... More
M&L for repair to main electrical panel at sub stations by tightning the all loose connections of the cable ends & replacing the damaged/US/burnt aluminium lugs of required sizes, insulating/secure the weak insulated portion of cable endsinside the panel by taping with good quality of insulation tape, clean the dust by air blower complete all as specified and directed.
12
-
-
... More
Dismantling and Taking Out old unserviceable LT Panel and Supply, installation, Commissioning and testing LT panel board of size 1200 x 1000 x 300 mm (Approx) for 3 phase, 4 wire, 415 Volts, AC, 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitable shape/ size canopy on top, made out of 3.15 mm thick MS sheet with using 50mm x 50mm x 6mm angle iron frame and supports, duly finished with powder coated of approved colour over a coat of red oxide primer all over steel surfaces complete with separate compartment of suitable shape and size with shutter and locking arrangement for each switchgear and including PCC work for fixing panel legs 45 cm above ground level and Bus bar of aluminium conductor suitable shape and size for 3 phase rating of 600 amps and for neutral 400 Amps rating including taking out end connectinons of the existing cables and fixing the cable with the panel using new lugs and glands of suitable size, separate cable alley for outgoing cables including following switchgear & controls.
(i) Incoming:-
(a) Micro procecessor based MCCB,500 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA, with adjustable load setting - 01 No. (b) Ammeter three phase, digital electronic type, size of 96 mm X 96mm, rating of 0-600 Amps, and in built selector switch and 3 current transformer of suitable ratio and capacity - 1 No.
(c) Indicating lamps LED type for three phases - Qty 1 set of 3 Nos (RYB).
(d) Voltmeter, three phase, (0-500V) range digital electronic type with in built selector switch - 1 No.
(ii) Out going:-
(a) MCCB, 160 Amps, 4 pole 415 Volts AC supply ,having braking capacity lcu =25 KA -4 No. (b) MCCB, 125 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA - 4 Nos. (c) MCB, 63 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA - 10 Nos. (d) MCB, 40 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA - 8 Nos. (e) MCB, 32 Amps, SPN, 415 Volts, AC supply, having breaking capacity Icu = 16 KA - 4 Nos (F) MCB, 25 Amps, single pole, 415 Volts, AC supply, having breaking capacity Icu = 10 KA - 6 Nos
Note :-
1. Before fabrication of panel the contractor shall submit detailed general arrangement drawing and single line diagram of all panel for approval. A drawing shall also show foundation details, list of components in the manufacturer's refernce and bill of materials.
2. Panel should be manufactured by CPRI approved and manufacuturer's CPRI test certificate to be produced.
1
-
-
... More
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down protection pipe,PCC Cover/Bricks etc all as specified and directed by the Engineer-in-Charge for the following sizes:35 Sq mm to 70 Sqmm
450
-
-
... More
Supply, laying, jointing and testing XLPE/ P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes .
-
-
-
... More
35 Sqmm 3.5 core
150
-
-
... More
50 Sqmm 3.5 core
100
-
-
... More
70 Sqmm 3.5 core
100
-
-
... More
95 Sqmm 3.5 core
100
-
-
... More
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed by Engineer-in-Charge.
9.5
-
-
... More
Disconnecting & Taking out old U/S joints and Supplying, Fixing, jointing and testing for provision of straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables all as specified and directed by the Engineer-in-Charge.
-
-
-
... More
10 Sqmm to 16 Sqmm 2 core
4
-
-
... More
25 Sqmm to 50 Sqmm 3½ core
20
-
-
... More
70 Sqmm to 120 Sqmm 3½ core
10
-
-
... More
150 Sqmm to 185 Sqmm 3½ core
1
-
-
... More
240 Sqmm to 300 Sqmm 3½ core
1
-
-
... More
Supply & fix in repair Busbar chamber 6 way with aluminium busbars for MCCBS upto rating 400 amps for three phase four wire system having separate earth link complete all as specified and directed.
1
-
-
Evaluation Notes How It Works ?