Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Drainage Work
Eprocure
Opening Date22 Jan 2025
Closing Date27 Feb 2025
Tender Amount₹ 42,44,48,000
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694445_1Tender No
CEBZ /GWL /TOKEN/ 10 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lump sum price worked out by the contractor for INTERNAL ELECTRIC SUPPLY WORKS as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
1
35032
-
... More
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
1
1125301
-
... More
Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY WORKS as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
1
3977438
-
... More
Lump sum price worked out by the contractor for ROAD PATH WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
1
14584568
-
... More
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
1
560569
-
... More
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VII (Ref prepriced schedule attached seperately)
1
43400736
-
... More
Lump sum price worked out by the contractor for COMPOUND WALL , FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately)
1
8666581
-
... More
Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’ Part-IX (Ref prepriced schedule attached seperately)
1
49060951
-
... More
SCH 'A' Pt - X (MISCELLANEOUS ITEMS)
-
-
-
... More
INTERNAL ELECTRIC SUPPLY WORKS NOTE:- For items of INTERNAL ELECTRIC SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-II (INTERNAL ELECTRIC SUPPLY WORKS) shall also be applicable.
-
-
-
... More
M&L for Point wiring with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass /GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-
-
-
-
... More
One light point/exhaust fan controlled by one switch
15
-
-
... More
One 6A socket point controlled by one switch on same board
3
-
-
... More
All as per srl item no. 4.01 here-in-before but with 2.5 sq mm FRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
3
-
-
... More
S&F of LED Tube light fitting batten type 18/20W, 230V, efficiency 120 Lumens per watt, colour temperature 6500k (Cool White), Power factor grater than 0.9, Polycarbonate body, CRI 80, IP Rating, IP 20, THDv with in 5 % and THDi (8-10%) and integrated Electronic driver complete with al accessories internally Pre-wired and including connecting with 3 Core twisted flexible copper conductor cable of suitable size from celling rose all as specified and directed.
Notes:- (i) The rate of three core twisted flexible copper conductor cable of suitable size for connection is included in this item and noting shall be paid extra on this account.
(ii) Warranty for replacement of each LED lite fitting shall not be less than 2 years from the date of purchase.
(iii) Date of purchase shall be marked on each fixture with permanent marker for redeeming warranty benefits.
12
-
-
... More
EXTERNAL WATER SUPPLY WORKS NOTE:- For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-III (EXTERNAL WATER SUPPLY WORKS) shall also be applicable.
-
-
-
... More
M&L for cutting of existing 80 mm dia Gl pipes and inserting Tee of size 80mm x 80mm x 50 mm for tapping including excavation and earth work complete for branch connection of 50mm dia bore of pipe existing CI pipeline complete all as specified and directed.
1
-
-
... More
EXTERNAL ELECTRIC SUPPLY WORKS
NOTE:- For items of EXTERNAL ELECTRIC SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL ELECTRIC SUPPLY WORKS) shall also be applicable.
-
-
-
... More
Supply & Fix fire Extinguisher life guard ISI ABC of 10 KG complete all as specified and directed.
4
-
-
... More
S & F PVC Three core copper conductor 1.5 Sqmm alongwith PVC pipe of dia 20mm for protection from junction box to bracket complete all as specified and directed.
200
-
-
... More
Supply, & Fixing of weather/ dust, vermin proof LT junction box factory made out of CRCA sheet 2mm thick complete with inside, outside powder coated, rubber gasket packing with suitable size with 20 amps SPN aluminium busbar duly insulated (including self insulated) maintaining proper space for each busbar, & proper arrangement for passing incoming/ outgoing LT cable and fixed to pole with 02 Nos MS clamps, Nuts bolts and washer etc complete including self closing locking arrangement complete all as specified and directed.
20
-
-
... More
M&L for GI brackets bending and shaping of size 14mm dia GI Pipe light grade overall length 1.2 mtr including necessary clamps, brackets and bolts etc and to fixing on electric pole all as specified and directed
20
-
-
... More
Construction of platform for transformer of size 3.0 mtr x 3.0 mtr x 1.2 mtr high with suitable iron clamps for cable protection complete all as specified and directed and as shown in drawing.
Note :- (i) Fencing and gate around the platform shall be measured and paid separately in the relevant schedule.
(ii) Except the overall size of the platform all other details and specificaitons shall be followed from TD drawing CEBZ/TD/90/2011 Sheeet 1/1 and overall dimension shall be as specified above in this item.
(iii) Plaster shall be in CM (1:6) and PCC in foundation shall be Type D2 (1:4:8) and brickwork shall be in CM (1:4)
1
-
-
... More
Supply,testing and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire outdoor type with acoustic enclosure as per IS 7888,engine as per IS:10001/ 10002 and Alternator as per IS: 4722 complete with automatic governor,relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB IV + Norms and foundation etc of following under metioned capacity along with remote monitor system having following facility without any cost online detail of DG parameter on mobile/Laptop Desktop 1. Phase Voltage 2. Current 3. Frequency 4. Genset KVA, KW, KWH, KVAR, 5. Power Factor 6. Canopy Temp. 7. Lube oil pressure 8. Engine temperature 9. RPM 10. Run Hours 11. Number of starts 12. Fuel level 13. Auto. Manual stop 14. Battery charging condition with AMF feature Complete all as specified and directed. (For Ser No 6.07 to 6.09)
-
-
-
... More
Capacity 30 KVA DG SET, producing 42BHP@1500RPM, Zone-2 Complete all as specified and directed.
1
-
-
... More
Capacity 70 KVA DG SET, producing 42BHP@1500RPM, Zone-2 Complete all as specified and directed.
1
-
-
... More
Capacity 15 KVA DG SET, producing 20.9 BHP @ 1500 RPM , Zone-3 Complete all as specified and directed., Zone-3
1
-
-
... More
Capacity 100 KVA DG SET, producing 156 BHP @ 1500 RPM DG SET, Zone2&3 MPS Complete all as specified and directed.
1
-
-
... More
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non linear load 15% , of 15 KVAR capacity. (Zone 1) complete all as specified and directed.
1
-
-
... More
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non linear load 15% , of 30 KVAR capacity. (Zone 2) Complete all as specified and directed.
1
-
-
... More
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non linear load 15% , of 7.5 KVAR capacity. (Zone 3) Complete all as specified and directed.
1
-
-
... More
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible nonlinear load 15% of 50 KVAR (25 x 2) KVAR capacity. (Zone 2&3) Complete all as specified and directed.
1
-
-
... More
S&F and testing LT power distribution Indoor panel board (MPS ZONE-1) with CRCA sheet metal and manufactured by CPRI approved manufacturer, indoor cubicle type, 415 Volts, 50Hz, free floor mounted front and back openable, made out of 2.0 mm thick CRCA sheet of suitable size to accomodate the following items, vermin proof, dust proof, supported on and including ISMC 75X40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement ie nuts,bolts, washers, clamps etc with naturally air cooled Aluminium bus bar 4 strips suitable for 200 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoing and outgoing with sufficient working space inside including installing, testing and commissioning complete all as specified and as directed consisting of following:-
Incoming : 63A TPN (16kA) MCCB with O/L & S/C protection, Spreaders & Extended Rotary Handle along with Metering along with, Phase Indicating Lights, along with required CT, CF etc. – 1set. Outgoing : (i) FASD, 3No 7.5HP Star/Delta Starter with 4No. 40A, TPN, & suitable size of Contactor, Thermal Over Load Relay, Star/Delta Timer, Ammeter Direct (Only on Y Phase) ,Single Phase Preventer, On/ Off/Trip Indicating Lights, On/off Push Button, Auto/ Manual Push Button including all associated accessories - 03 Nos (ii) MCB SPN 40A, 10kA MCB - 1 set (For Bldg) ZONE
1
-
-
... More
S&F and testing LT power distribution Indoor panel board (MPS ZONE-2) with CRCA sheet metal and manufactured by CPRI approved manufacturer, indoor cubicle type, 415 Volts, 50Hz, free floor mounted front and back openable, made out of 2.0 mm thick CRCA sheet of suitable size to accomodate the following items, vermin proof, dust proof, supported on and including ISMC 75X40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement ie nuts,bolts, washers, clamps etc with naturally air cooled Aluminium bus bar 4 strips suitable for 200 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoing and outgoing with sufficient working space inside including installing, testing and commissioning complete all as specified and as directed consisting of following:-
Incoming :125 A TPN (25kA) MCCB with O/L & S/C protection, Spreaders & Extended Rotary Handle along with Metering along with, Phase Indicating Lights, along with required CT, CF etc. – 1set. Outgoing : (i) FASD, 3No 20 HP Star/Delta Starter with 4No. 63A, MCCB TPN, & suitable size of Contactor, Thermal Over Load Relay, Star/Delta Timer, Ammeter Direct (Only on Y Phase) ,Single Phase Preventer, On/ Off/Trip Indicating Lights, On/off Push Button, Auto/ Manual Push Button including all associated accessories - 03 Nos
(ii) MCB SPN 40A, 10kA MCB - 1 set (For Bldg) Note : The Starters shall be started through PLC for operation of Pumps as described in Enquiry through Float Switches
1
-
-
... More
S&F and testing LT power distribution Indoor panel board (MPS ZONE-3) with CRCA sheet metal and manufactured by CPRI approved manufacturer, indoor cubicle type, 415 Volts, 50Hz, free floor mounted front and back openable, made out of 2.0 mm thick CRCA sheet of suitable size to accomodate the following items, vermin proof, dust proof, supported on and including ISMC 75X40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement ie nuts,bolts, washers, clamps etc with naturally air cooled Aluminium bus bar 4 strips suitable for 100 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoing and outgoing with sufficient working space inside including installing, testing and commissioning complete all as specified and as directed consisting of following:- Incoming : 40 A TPN (16kA) MCCB with O/L & S/C protection, Spreaders & Extended Rotary Handle along with Metering along with, Phase Indicating Lights, along with required CT, Cf etc. – 1set. Outgoing : (i) DOL, 3 HP, Starter with 1No. 20 A, MCB TPN, & suitable size of Contactor, Thermal Over Load Relay, Ammeter Direct (Only on Y Phase) ,Single Phase Preventer, On/ Off/Trip Indicating Lights, On/off Push Button, Auto/ Manual Push Button including all associated accessories - 03 Nos
(ii) MCB SPN 40A, 10kA MCB - 1 set (For Bldg)
Note : The Starters shall be started through PLC for operation of Pumps as described in Enquiry through Float Switches
1
-
-
... More
S&F and testing LT power distribution Outdoor panel board (MPS ZONE-2&3) with CRCA sheet metal bolted with tappered roof and manufactured by CPRI approved manufacturer, indoor cubicle type, 415 Volts, 50Hz, free floor mounted front and back openable, made out of 3.15 mm thick CRCA sheet of suitable size to accomodate the following items, vermin proof, dust proof, supported on and including ISMC 75X40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement ie nuts,bolts, washers, clamps etc with naturally air cooled Aluminium bus bar 4 strips suitable for 200 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoing and outgoing with sufficient working space inside including installing, testing and commissioning complete all as specified and as directed consisting of following:-Incoming :160 A TPN (25kA) MCCB with O/L & S/C protection, Spreaders & Extended Rotary Handle along with Metering along with, Phase Indicating Lights, along with required CT, Cf etc. – 1set.
Outgoing : (i) FASD,2 Nos 80HP Star/Delt a Starter with 02 No. 160 Amp MCCB, with suitable size Contactor, Thermal Over Load Relay, Star/Delta Timer, Ammeter Direct, (Only on Y Phase) , Single Phase Preventer, On/ Off/Trip Indicating Lights, On/off Push Button, Auto/ Manual Push Button including all associated accessories –02 Set ,01-Nos of 63 Amp mccb for APFC Outgoing : MCB SPN, 40A, 10kA MCB - 2 set
1
-
-
... More
ROAD PATH WORKS NOTE:- For items of ROAD PATH WORKS notes given at the beginning of Sch ‘A’ Part-V (ROAD PATH WORKS) shall also be applicable.
-
-
-
... More
Demolition of bituminus road/Soling/WBM concrete in any description and in any position not otherwise specifically provided for (below or above ground level) (Note : Work for crossing for sewaage line)
920
-
-
... More
Removing of dismantled materials exceeding 1.5 Km but n.exc 5.0 Km and depositing where directed complete all as specified and directed
920
-
-
... More
M&L for barricading around the excavation and safety services alongwith provisioning of road diversion with reflection taping and misc safety work by reconditioned galvalume/CGI sheet of 1.50 mtr height, iron pipe picket 50mm dia with bamboo support, alongwith diversion trolly for traffic diversion incl making of kachha path with rolling. Note: Qty shall be used in repeated manner for the inter sewar length of the project complete all as specified and as directed.
4200
-
-
... More
SEWAGE DISPOSAL WORKS NOTE:- For items of SEWAGE DISPOSAL WORKS notes given at the beginning of Sch ‘A’ Part-VII (ISEWAGE DISPOSAL WORKS) shall also be applicable.
-
-
-
... More
Supply, Laying, Jointing, Field Testing, Commissioning complete at site of (PE material) HDPE Double wall corrugated pipe, for non pressure underground drainage and sewerage with smooth internal & corrugated external surface confirming to IS 16098:Part-2 2013 with spigot or plain end of approved with necessary jointing material coupler complete all as specified and directed by Engr-in-charge & GE. (For Ser No 8.02 to 8.05) Note : The pipes shall be stored & stacked properly as directed by GE to avoid damage.
-
-
-
... More
All as per item No 8.01 above but for 150mm dia pipe.
11023
-
-
... More
All as per item No 8.01 above but for 200mm dia pipe.
15674
-
-
... More
All as per item No 8.01 above but for 250mm dia pipe.
9091
-
-
... More
All as per item No 8.01 above but for 300mm dia pipe.
4615
-
-
... More
M&L for Construction of circular type manhole 0.90 m internal dia at bottom and 0.56m dia at top & 0.90 m deep in brick masonry built in CM (1:4), in side cement plaster 12 mm thick with CM (1:3) finished with a floating coat of neat cement, foundation PCC (1:3:6) type C2 using 40mm graded stone aggregate, and making necessary channel in PCC (1:2:4) Type B1 using 20mm graded stone aggregate finished with a floating coat of neat cement, all complete as per standard design with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in PCC (1:2:4) type B1 using 20mm graded stone aggregate with PVC Coated M.S Foot Rest including necessary formwork complete all as specified and directed.
837
-
-
... More
Extra depth for circular type manhole 0.90 m internal dia (at bottom) & depth beyond 0.90 m to 1.65 m
381
-
-
... More
M&L for Construction of circular type manhole 1.20 m internal dia at bottom and 0.56m dia at top & 0.90 m deep in brick masonry built in CM (1:4), in side cement plaster 12 mm thick with CM (1:3) finished with a floating coat of neat cement, foundation PCC (1:3:6) type C2 using 40mm graded stone aggregate, and making necessary channel in PCC (1:2:4) Type B1 using 20mm graded stone aggregate finished with a floating coat of neat cement, all complete as per standard design with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in PCC (1:2:4) type B1 using 20mm graded stone aggregate with PVC Coated M.S Foot Rest including necessary formwork complete all as specified and directed.
552
-
-
... More
Extra depth for circular type manhole 1.20 m internal dia (at bottom) & depth beyond 1.65 m to 2.30 m
166.5
-
-
... More
M&L for Construction of circular type manhole 1.50 m internal dia at bottom and 0.56m dia at top & 0.90 m deep in brick masonry built in CM (1:4), in side cement plaster 12 mm thick with CM (1:3) finished with a floating coat of neat cement, foundation PCC (1:3:6) type C2 using 40mm graded stone aggregate, and making necessary channel in PCC (1:2:4) Type B1 using 20mm graded stone aggregate finished with a floating coat of neat cement, all complete as per standard design with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in PCC (1:2:4) type B1 using 20mm graded stone aggregate with PVC Coated M.S Foot Rest including necessary formwork complete all as specified and directed.
697
-
-
... More
Extra depth for circular type manhole 1.50 m internal dia (at bottom) & depth beyond 2.30 m to 7.00 m :
656
-
-
... More
Supply of all material, labour, T&P machineries etc & laying & jointing by welding of required dia 10mm thick MS Pipe are laying the same by trenchless technology are required purpose by maintaining required gradient as per site complete all as specified and as directed.
150
-
-
... More
M&L for 600 mm dia S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) complete all as specified and as directed.
22
-
-
... More
M&L for construction of full brick masonary valve pit chamber of size 900x900x900 mm (internal dimensions) including necessary excavation, earth work, plastering on both side and MS sheet cover 6 mm thick with 2 Nos hinges MS hinges, welded to and including angle iron 40x40x6 mm frame with lifting hook including locking arrangement with lock and key of 50 mm pad lock (pad lock brass 6 levers with key in duplicate) duly painting the steel surfaces in two coats or synthetic enamel paint over one coat of red oxide primer complete all as specified & directed.Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
413
-
-
... More
Supply laying, connecting, jointing and testing ductile iron pressure pipe ISI maked to IS-8329-2000 (Reaffirmed - 2005 Edition 4.1) of 100 mm dia, with spigot and socket ends, for water supply class K-9 with cement mortar lining inside the metallic zinc coating with finishing layer of bituminous paint on outside the pipe without polyethylene sleeves but including "Tyton Joint" supplied with ISI marked rubber or fiber board gasket conforming to IS-5382-1982 (Reaffimed-2003) with dual hardness of type-2 (bulb) and type-5 (Heel) quality laid in trenches complete all as specified and directed. Note:- Earth work and DI specified / fittings of the pipe shall be measured and paid separately under appropriate item.
17097
-
-
... More
Supply laying, connecting, jointing and testing ductile iron pressure pipe ISI maked to IS-8329-2000 (Reaffirmed - 2005 Edition 4.1) of 150 mm dia, with spigot and socket ends, for water supply class K-9 with cement mortar lining inside the metallic zinc coating with finishing layer of bituminous paint on outside the pipe without polyethylene sleeves but including "Tyton Joint" supplied with ISI marked rubber or fiber board gasket conforming to IS-5382-1982 (Reaffimed-2003) with dual hardness of type-2 (bulb) and type-5 (Heel) quality laid in trenches complete all as specified and directed.
Note:- Earth work and DI specified / fittings of the pipe shall be measured and paid separately under appropriate item.
6129
-
-
... More
M&L, for DI fittings such as bends (any type, radius and angle) Tapers any type (Straight bends, increasing, decreasing or double socket/flanged etc) Tee pieces, single branch 'Y' junction,double branch, cross (all sockets or sockets & spigot/ all flanged etc) collars, Caps & plugs for spigot socketed/Flanged pipes upto 200 mm dia bore complete all as specified and directed.
1500
-
-
... More
Supply and fixing of Cast Iron Air Valves with Two air Outlets, confirming to IS 14845 of size 50 mm dia bore and fixing up in cast iron water supply mains of size 50 mm dia complete all as specified and directed.
Note:- for pumps Delivery pipe
5
-
-
... More
Supply & Fixing of CI Foot Valve ISI marked with Half round Double GM flap of size 150 mm and connected with necessary bolts, nuts & washers, gaskets etc complete all as directed.
Note:- for Treated water pumps
2
-
-
... More
Supply, install , testing & commissioning of Non clog Vertical submersible pumps with chrome steel impeller and cutter, non clog to pass 40 mm Size particle with guide rail and lifting chain complete with 600 LPM discharge, 40 Mtr Head (Capacity 7.5 HP) with two years guarantee complete including all electrical connections, all as required at site complete and directed by engineer in charge complete all as specified & directed .
3
-
-
... More
Supply, install , testing & commissioning of Non clog Vertical submersible pumps with chrome steel impeller and cutter, non clog to pass 40 mm Size particle with guide rail and lifting chain complete with 1500 LPM discharge, 40 Mtr Head (Capacity 20 HP) with two years guarantee including all electrical connections, all as required at site complete and directed by engineer in charge complete all as specified & directed .
3
-
-
... More
Supply, install , testing & commissioning of Non clog Vertical submersible pumps with chrome steel impeller and cutter, non clog to pass 40 mm Size particle with guide rail and lifting chain complete with 200 LPM discharge, 25 Mtr Head (Capacity 03 HP) with two years guarantee including all electrical connections, all as required at site complete and directed by engineer in charge complete complete all as specified & directed .
3
-
-
... More
Supply, install, testing and commissioning complete Centrifugal Mono block pump set coupled with electrical opretaed Motors 440 volts, 50 Hz required head not less than 91 mtrs, suction/delivery150 mm x 100 mm dia, with discharge capacity not less than 2350 LPM, Cap 80 HP, 1500 RPM, including fixed on suitable size MS angle placed on PCC foundation and grouting with suitable size/Nos Nut bolts & water supply suction and delivery pipe line connection including in required size or length of suction and delivery DI pipe line fixed in existing UG Sump & Delivery line & electrical connections all as required at site complete and directed by engineer in charge. Note:- (i) Quoated rates are includes, PCC foundation work, Nut bolts, MS chanel work, all elctrical connections and suitable size of Copper/aluminium cable (if required on site) not more than 10 RM complete (ii) DI Pipe & fittings Should be Measure and Paid separetaly.Supply and fixing Pumping sets.
2
-
-
... More
Supply and fix puddle flange having both side flange , attached with sluice valve of particular size with 8 m telescopic shaft for operation of valve from ground of size 450 mm dia complete with nut, bolt, etc complete all as specified and directed.
1
-
-
... More
Supply and fix puddle flange having both side flange , attached with sluice valve of particular size with 8 m telescopic shaft for operation of valve from ground of size 300 mm dia complete with nut, bolt, etc complete all as specified and directed.
2
-
-
... More
Supplying and fixing factory made Mild steel chain Pulley block with chain of capacity 0.5 Ton as specified complete all as specified and directed.
3
-
-
... More
Supply & Fix Guide rail from 65 mm dia pipe for Submersible Pump set with Hock Supports etc Installed at Zone 1 at 7.75 M Well complete all as specified and directed.
3
-
-
... More
Supply & Fix Guide rail from 65 mm dia pipe for Submersible Pump set with Hock Supports etc Installed at Zone 2 at 7.75 M Well complete all as specified and directed.
3
-
-
... More
Supply & Fix Guide rail from 65 mm dia pipe for Submersible Pump set with Hock Supports etc Installed at Zone 3 at 6 M Well complete all as specified and directed.
3
-
-
... More
M&L for Construction of header made out of MS pipe of 300 mm dia (Thickness of MS pipe not less than 6mm), 2.5 mtr length (In two piece of each 1.25 meter length ,and providing holes for fixing/welding MS pipe pieces with three flange end for fixing of sluice valve size 50 mm dia=03 Nos for incoming,and 100 mm dia =01 Nos for outgoing . MS pipe should be fixed on PCC foundation and top 1:3:6 type C1 using 20mm graded trap stone aggregate (30cm in foundation on top) & anchoring with MS strip at 3 place (MS strip should be grouted in PCC as suitable) and masonary block constructed with 230 mm thick brickss sub class B bricks builts in cement mortar 1:4 and 15mm thick plastering to brick,masonary in cement mortar ,including Excavation and earth work complete all as specified and directed.
Note (i) Quoted rates are also included to fixing/welding of MS pipe cut pieces as required size/type/length on site each for all 04 Nos inlet/outlet water supply pipeline connected & all type PCC foundation & brick work complete (ii) All T&P material will be provided by the contractor without any cost. (iii) MS fitting like Flange,Dead plate,bleds reducer,etc and sluice/ butterfly valve should be measured and paid separatly under appropiate item below
2
-
-
... More
M&L for Construction of header made out of MS pipe of 300 mm dia (Thickness of MS pipe not less than 6mm), 2.5 mtr length (In two piece of each 1.25 meter length ,and providing holes for fixing/welding MS pipe pieces with three flange end for fixing of sluice valve size 100 mm dia=03 Nos for incoming,and 150 mm dia =01 Nos for outgoing . MS pipe should be fixed on PCC foundation and top 1:3:6 type C1 using 20mm graded trap stone aggregate (30cm in foundation on top) & anchoring with MS strip at 3 place (MS strip should be grouted in PCC as suitable) and masonary block constructed with 230 mm thick brickss sub class B bricks builts in cement mortar 1:4 and 15mm thick plastering to brick,masonary in cement mortar ,including Excavation and earth work complete.
Note (i) Quoted rates are also included to fixing/welding of MS pipe cut pieces as required size/type/length on site each for all 04 Nos inlet/outlet water supply pipeline connected & all type PCC foundation & brick work complete (ii) All T&P material will be provided by the contractor without any cost. (iii) MS fitting like Flange,Dead plate,bleds reducer,etc and sluice/ butterfly valve should be measured and paid separatly under appropiate item below
1
-
-
... More
S&F Float Switch cum Ultrasonic Level Sensor with display of MPS provision including necessary writing of different levels complete all as specified and directed.
Note:-(i) For MPS
(ii) The testing shall be carried out by the contractor at their own expense.
6
-
-
... More
Supply & Commissioning of Pressure transmitter/sensor complete all as specified and directed Note:- (i) For treated water Distribution (ii) The testing shall be carried out by the contractor at their own expense.
1
-
-
... More
Supply and fix Crane Hand operated OH complete with span 9 to 11 meter, lift 4.5 to 6 meter and of capacity 2 tons all as specified and directed.
1
-
-
... More
COUMPOUND WALL / FENCING & GATE WORKS NOTE:- For items of COUMPOUND WALL / FENCING & GATE WORKS notes given at the beginning of Sch ‘A’ Part-VIII (COUMPOUND WALL / FENCING & GATE WORKS) shall also be applicable.
-
-
-
... More
M&L for Provn of Steel Gate 5.50m wide incl excavation and earth work, formwork, reinforcement bars, RCC (M-25) in pillars, painting to all gate complete all as shown on drawings & as specified and directed by Engr-in charge. (Ref TD No :- CEBZ/STD/104/2011 Sheet 1/3 to 3/3)
4
-
-
... More
EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS NOTE:- For items of EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS notes given at the beginning of Sch ‘A’ Part-IX (EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS ) shall also be applicable.
-
-
-
... More
M&L for approved earth filling with approved soil (non expansive nature) brought from out side MD land, filling in trenches or paving laid in layers n.exc 25cm thick spread, levelled and rammed including rough excavation n.exc 1.5m deep and getting out in soft soil, removing excavated soil exc 1.5 Km but n.exc 5.00 Km, spreading and levelling in layers & well ramming including watering as required etc. complete all as specified and directed.
2975
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%