Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Oct 2024
Closing Date2 Nov 2024
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678481_1Bid Award Id
ViewTender No
83944/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender documents with errata and amendments
BOQ Items
... More
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
40
-
-
... More
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
21.6
-
-
... More
Supply & laying unreinforced precast concrete cable cover class HVP type 1, with peak shape, dimension 450mm x 180mm x 40mm peak thickness as per IS 5820: 1970 complete all as specified and as directed.
1000
-
-
... More
M&L Cement Concrete (1:4:8) type D-2 (40mm Graded Stone Aggregate) as Lean Concrete, Bed Concrete in Foundation of Poles, etc., including Formwork (as required), complete all as specified and as directed.
11
-
-
... More
M&L Cement Concrete (1:3:6) type C-2 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as required), complete all as specified and as directed.
0.9
-
-
... More
M&L Cement Concrete (1:2:4) type B-1 (20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as required), complete all as specified and as directed.
0.48
-
-
... More
Disconnecting, taking out old unserviceable under ground cable of rated voltage 6.35 kV/ 11 kV, upto any size of nominal cross sectional area of main conductor, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit complete all as specified and as directed.
200
-
-
... More
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 6.35 kV/ 11 kV, three phase, earthed system, 3 core, screened, armoured power cable, 95 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
200
-
-
... More
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 50 sqmm to 95 sqmm complete all as specified and as directed.
2
-
-
... More
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed.
2
-
-
... More
S & F XLPE cable end termination, cold shrinkable, indoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 50 sqmm to 95 sqmm complete all as specified and as directed.
2
-
-
... More
S & F XLPE cable end termination, cold shrinkable, indoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed.
2
-
-
... More
S & F cable jointing kit for 6.35 kV/ 11 kV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
1
-
-
... More
S & F cable jointing kit for 6.35 kV/ 11 kV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
2
-
-
... More
S & F cable jointing kit for 6.35 kV/ 11 kV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm complete all as specified and as directed.
2
-
-
... More
Dismantling danger notice plate any type and size and setting aside for re-use or removing to store or for schedule of credit complete all as specified and as directed.
50
-
-
... More
M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 250 mm X 200 mm complete all as specified and as directed.
50
-
-
... More
Dismantling insulators any type, any size complete all as specified and as directed.
75
-
-
... More
Dismantling and taking down Lightning arrestor of any size and any type complete all as specified and as directed.
9
-
-
... More
Supply and fix metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, station class, low duty, nominal discharge current 10 kA, switching impulse discharge current 0.5 kA, repetitive charge transfer rating (Qrs) more than 1.0 C, thermal energy rating (Wth) more than 4 kJ/kV, nominal system voltage 33 kV, highest system voltage 36 kV, rated voltage of arrester 27 kV, continuous operating voltage 21.6 kV, temporary overvoltage (30.45 kV for 1 s, 28.50 kV for 10 s, 26.35 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 170 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 72 kV, switching impulse residual voltage (30/60 µs) at switching impulse discharge current maximum 56 kV, high current impulse withstand capability (4/10 µs) 100 kA, minimum creepage distance 900 mm complete all as specified and as directed.
3
-
-
... More
S & F polymer pin insulator, Type B, Nominal System voltage 11 kV, highest system voltage 12 kV, visible discharge test voltage 9 kV, wet power frequency withstand voltage 35 kV, power frequency puncture withheld voltage 105 kV, impulse withstand voltage 75 kV, minimum total creepage distance 230 mm, minimum failing load 5 kN, of suitable size with galvanised steel insulator pin, nut, washers complete all as specified and as directed.
50
-
-
... More
S & F polymeric composite disc insulator, ball and socket type, Type B, Nominal System voltage 11 kV, highest system voltage 12 kV, visible discharge test voltage 9 kV, wet power frequency withstand voltage 35 kV, impulse withstand voltage 75 kV, minimum total creepage distance 230 mm, minimum failing load 70 kN, of suitable size with galvanised steel stud pin, nut, washers complete all as specified and as directed.
25
-
-
... More
Supply and fix metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, distribution class, heavy duty, nominal discharge current 10 kA, repetitive charge transfer rating (Qrs) more than 0.4 C, thermal charge transfer rating (Qth) more than 1.1 C, nominal system voltage 11 kV, highest system voltage 12 kV, rated voltage of arrester 9 kV, continuous operating voltage 7.2 kV, temporary overvoltage (10.50 kV for 1 s, 9.90 kV for 10 s, 9.35 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 75 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 30 kV, high current impulse withstand capability (4/10 µs) 100 kA, minimum creepage distance 300 mm complete all as specified and as directed.
6
-
-
... More
Dismantling air break gang operated switches vertical/horizontal mounted, drop out fuse assembly, any rating, any type including insulators and operating mechanism, carrying to MES store or taken on schedule of credit complete all as specified and as directed.
11
-
-
... More
Supply and fix in repairs drop out fuse assembly, triple pole mounted on polymer HT insulator 6 Nos and mild steel galvanised steel frame rating upto 200 Amp, 33 kV complete with drop out fuse and electrical connections, jumpering by ACSR conductor and connectors complete all as specified and as directed.
1
-
-
... More
Supply and fix in repairs drop out fuse assembly, triple pole mounted on polymer HT insulator 6 Nos and mild steel galvanised steel frame rating upto 200 Amp, 11 kV complete with drop out fuse and electrical connections, jumpering by ACSR conductor and connectors complete all as specified and as directed.
4
-
-
... More
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 33 kV, rated voltage 36 kV, rated normal current 400 Amps, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 70 kV (rms) (ii) across the isolating distance 80 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 170 kV (Peak) (ii) across the isolating distance 195 kV (Peak), Rated short-time withstand current 20 kA for 3 seconds, rated peak withstand current 50 kA for climatic conditions at the site, mechanically operated mounted on polymer insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
2
-
-
... More
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 11 kV, rated voltage 12 kV, rated normal current 400 Amps, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 28 kV (rms) (ii) across the isolating distance 32 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 75 kV (Peak) (ii) across the isolating distance 85 kV (Peak), Rated short-time withstand current 25 kA for 3 seconds, rated peak withstand current 63 kA for climatic conditions at the site, mechanically operated mounted on polymer insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
4
-
-
... More
M& L for servicing of 11 kV gang operated air break switch by cleaning the contact, pin insulator with CTs and applying petroleum jelly at the contact point and down rod links for smooth operation including replacing the rusted, corroded bolts, nuts (using galvanised iron nuts) along with replacing the burn aluminium thimbles and defective insulators, male and female contact as required at the site complete all as specified and as directed. Note: - (1) Insulator, male (moving) and female (fixed) contact shall be measured and paid separately under the relevant items. (2) The cost for replacement of aluminium thimbles, GI nuts, bolts, washers, lubricating, materials etc. shall be deemed to be included in the unit rate quoted by the contractor for the item.
10
-
-
... More
Supply and fix male contact /moving contact blade for gang operated air break switch complete all as specified and as directed.
30
-
-
... More
Supply and fix female contact/fix contact jaw for gang operated air break switch complete all as specified and as directed.
30
-
-
... More
Supply and fix tinned copper flexible jumper for gang operated air break switch complete all as specified and as directed.
30
-
-
... More
M & L for maintenance of 33 KV(yard) power grid bus bar structure at MRS 33/11 kV Dronachal including provision of red, white, yellow PVC busbar sleeves including preparing and painting on steel tubular poles/PCC pole/MS Channels - 15 Nos (9 to 13 metres long) including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: -
(a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions.
1
-
-
... More
Dismantling steel poles/ struts, any size, transporting to store and stacking or for schedule of credit complete all as specified and as directed.
6
-
-
... More
M & L for steel tubular swaged pole 410 SP-55 (11.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including preparing and painting on steel tubular swaged pole 410 SP-22 (8.50 metre long) including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: -
(a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions
6
-
-
... More
Dismantling ACSR or AAC conductors removing to store or taken on schedule of credit complete all as specified and as directed.
2
-
-
... More
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
2
-
-
... More
Dismantling earth wire or copper conductor, service feeder or distributor span removing to store or taken on schedule of credit complete all as specified and as directed.
1
-
-
... More
M & L for Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed.
1
-
-
... More
M & L for stay assembly of stay rod of diameter 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and as directed.
4
-
-
... More
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside for re-use or removing to store or for schedule of credit complete all as specified and as directed.
5
-
-
... More
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
5
-
-
... More
M & L for dismantling, re-erecting, restringing, tensioning and repair to overhead line ACSR conductor of any size upto 5 conductors in one span as required on poles LT / HT including fixing insulators and jointing with ACSR conductor complete all as specified and as directed.
20
-
-
... More
M & L for preparing and painting on steel tubular swaged pole 410 SP-55 (11.00 metre long) including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: -
(a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions.
150
-
-
... More
M & L for preparing and painting on cross arms of electric poles (structure of two poles) of any height with two coats of aluminium paint over a coat of aluminium red oxide primer after scrapping the metal surfaces with emery sheet complete all as specified and as directed.
10
-
-
... More
M & L for preparing and painting on cross arms of electric poles (structure of four poles) of any height with two coats of aluminium paint over a coat of aluminium red oxide primer after scrapping the metal surfaces with emery sheet complete all as specified and as directed.
10
-
-
... More
M & L for loose filling with broken stone or boulder aggregates of gauge 40 to 80 mm in soakage pits, soakage wells, on open space etc. complete all as specified and as directed.
10
-
-
... More
Inspection/Servicing to outdoor VCB 33 KV 800 Amps of AREVA make with full functionality by doing following jobs including testing and commissioning to the entire satisfaction of Engineer-in-charge.
(a) Cleaning the external surface of bushing with CTC or liquid ammonia to remove the accumulation of dirt or any other deposits. Inspection of bushings and make sure that vibration due to break operation have not caused the bushings to move resulting misalignment of contacts.
(b) Checking the vacuum interrupter assembly and contact Checking the alignment of contacts and setting the contact surfaces to bare firm and uniform pressure and adjust the gap as per manufacture tolerance. Badly potted contact needs to be replaced.
(c) Checking of operating voltage watt mechanism terminals tripping arrangement for positive tripping. Contacts to be examined for their condition and operation. Dress the pitted contacts.
(d) Inspecting all bolts, nuts pins and collar pins for tight and opened properly
(e) Inspection cleaning and relubrication of circuit breaker (f) calibration of outdoor VCB 33 KV 630 Amps along with primary current injection test of 33 KV current Transformers (CTs) & Potential Transformer (PTs) and checking the electrical circuit for fault condition and proper functioning for testing of L&T relay MC61AnX at MRS 33/0.433 KV Dronachal powerhouse including calibration of relay indoor control panel complete all as specified and as directed.
3
-
-
... More
Servicing inspection cleaning of VCB outdoor switchgear system voltage 33 kv 50 Hz VCB with motorized operation mechanism 24 to 30 DC supply shunt trip close coil operation handle for spring charging relay master reset carefully tightening of cable connection applying greece and oil to moving and fixed mechanical part for its smooth operation and service. Report giving details of defective of if any along with list of spares for rectification including replacing spares issued by department and rectification of defects complete all as specified and as directed.
5
-
-
... More
Supply and fix Oil temperature meter and Winding temperature meter complete all as specified and as directed.
2
-
-
... More
Supply only Spring charging motor suitable for 11 KV, 800 Amps VCB, complete all as specified and as directed.
1
-
-
... More
Supply only for TNC switch uitable for 11 KV, 800 Amps VCB, complete all as specified and as directed.
2
-
-
... More
Supply and fix for hooter suitable for 11 KV, 800 Amps VCB, complete all as specified and as directed.
8
-
-
... More
M&L for dehydration of transformer oil of transformer of capacity 1000 KVA 33 KV/0.433KV ,oil capacity-1400 Litre by means of Centrifugal Filtration Plant to acheive minimum turnover of 3 cycle or till die electric strength to achieved upto 50 KV at 4 mm gap and testing complete including all arrangement of T&P and electrical equipment and transport etc in presence of Engr-in-Charge complete all as specified and as directed.
6500
-
-
... More
Supply and filling of new insulating transformer oil for make up of transformer of cap 33/0.433 KV during dehydration, confirming to IS 335/1993 and having dielectric strength of 50 KV at 4 mm gap complete all as specified and as directed.
500
-
-
... More
Supplying and laying synthetic Rubber insulated mats 3.0 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
4
-
-
Evaluation Notes How It Works ?