Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date11 Nov 2024
Closing Date25 Nov 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_668901_3Tender No
82681/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and fix, in repair, serviceable sealed unit compressor suitable for window type air conditioner of 1.5 TR / 2 TR, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as directed. Make:- As per existing Make at the site of work.
Note:- Refrigerant gas shall be measured and paid for separately under relevant item of this BOQ.
20
-
-
Supply and fix, in repair, serviceable sealed unit compressor suitable for split type air conditioner of 1.5 TR / 2 TR capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as directed. Make:- As per existing make. Note:- Refrigerant gas shall be measured and paid for separately under relevant item of this BOQ.
20
-
-
Supply and fix, in repair, serviceable sealed unit compressor suitable for water cooler of 40/80 litres capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as directed. Make:- As per existing Make at the site of work. Note:- Refrigerant gas shall be measured and paid for separately under relevant item of this BOQ.
10
-
-
Supply and filling, in replacement, compressor oil of sealed unit Compressor in water coolers, ACs, refrigerators and deep freezers, complete all as specified and directed by Engineer-in-Charge. Make:- As per existing Make at the site of work.
50
-
-
Supply and filling/charging Refrigerant (R -134a) Gas (CH₂FCF₃) complete including vacuum and pressure leakage testing with nitrogen (N₂), brazing work complete all as specified and directed by Engineer-in-Charge.
170
-
-
Supply and filling/charging refrigerant R-22/F-22 gas including vacuum and pressure leakage testing with nitrogen gas (N₂), brazing work complete all as specified and directed by Engineer-in-Charge.
300
-
-
M&L for disconnecting, dismantling and taking out the non-functional Air conditioner window type/split type of any description, any make and in any position, 1.5 TR /2.0 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using MAIC-DS solution, taking out and removing unserviceable/ defective wiring & parts, painting the bottom with one coat of black synthetic enameled paint, including testing of the AC and refixing complete all as specified and directed by Engineer–in–charge. Notes :-(i) The rate for above item shall be deemed to include for transportation to & from the site of work to MES workshop as directed by Engineer-in-charge for necessary repairs and testing of AC at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one, Charging of gas with leakage testing as required. ii) Cost of gas and necessary spare parts shall be measured and paid for separately under relevant items of this BOQ. iii) Visiting charge and Service charge of mechanic shall be deemed to be included under this item and No extra payment will be made to the contractor for mechanic visit.
60
-
-
S&F, in replacement, new sealed unit compressor of same existing capacity,description, make & model, suitable for capacity 1.5 TR window AC/split AC and connecting to suction/discharge of existing system with and including vacuum and pressure leakage testing with nitrogen gas in appropriate pressure and quantity complete all as specified and directed by Engineer-in-Charge. Note:- Refrigerant gas will be measured & paid for seperately under relavant item of this BOQ. Make : As per existing Make at the site of work.
20
-
-
All as item Srl No 11 above but 2.0 TR capacity complete all as specified and directed.
20
-
-
S&F, in replacement, AC Electric Blower motor of 1/10 HP, 1/7 HP to 1/5 HP 230 volts approx, 3 speed suitable for 1.5 TR/2.0 TR capacity window AC/ split AC complete all as specified and directed by Engineer-in-Charge. (Make : As per existing Make at the site of work.)
30
-
-
S&F in replacement of unserviceable running capacitor 36 mfd/45mfd/50 mfd suitable for 1.5 TR/2.0 TR capacity window AC/ split AC complete all as specified and directed by Engineer-in-Charge. (Make : As per existing Make at the site of work.)
30
-
-
S&F, in replacement, starting capacitor 80/100 mfd, 100/120 mfd 400 Volts, suitable for 1.5 TR/2.0 TR window AC/ split AC complete all as specified and directed by Engineer-in-Charge. (Make : As per existing Make at the site of work.)
30
-
-
S&F, in replacement, capacitor 3.15/4/6 mfd, 400 Volts for blower motor complete all as specified and directed by Engineer-in-Charge. (Make : As per existing Make at the site of work)
80
-
-
S&F, in replacement, PCBs complete with remote control 230 Volts, 50 Hz suitable for split ACs / window Acs, capacity 1.5TR/2.0 TR complete all as directed by Engineer-in-Charge. (Make : As per existing Make at the site of work)
30
-
-
S&F, in replacement, defective Relay contactor 6 Pin G7L-2A-TUBJ-CB (220-240VAC) for 1.5/ 2.0 TR split AC units with all electrical connection complete all specified and directed by Engineer-in-Charge.
30
-
-
S&F, in replacement, over load relay suitable for 1.5/2.0 TR capacity window ACs/split ACs /water coolers complete all as specified. (Make : As per existing Make at the site of work)
20
-
-
S&F, in replacement, PVC flexible cable PVC insulated and sheathed , 3 core, copper conductor multi-stranded, size 4 Sqmm round cable complete all as specified and directed by Engineer-in-Charge. (Make : As per existing Make at the site of work)
100
-
-
S&F, in replacement, Chromium plated PVC Knob, any type and any size suitable for window AC 1.5/2.0 TR capacity complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, PVC grill any type/ any size suitable for window type AC 1.5/2.0 TR capacity complete all as specified and directed by Engineer-in-Charge (Make: As per existing Make and Model at the site of work)
20
-
-
S&F, in replacement, rotary switch with knob 30 Amp. 250 volts complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, thermostate as per existing make/size sutaible for 1.5TR /2 TR window /split type AC complete all as specified and directed by Engineer-in-Charge
20
-
-
S&F, in replacement,copper filled with silica gel, automation Grade suitable for refrigerators, window ACs,split type ACs, water coolers etc complete all as specified and directed by Engineer-in-Charge
20
-
-
Disconnecting, dismantling and taking out existing defective/unserviceable condenser coil of any description,any make,any model & in any position and supplying & fixing same type new condenser coil, copper tube and aluminium fins suitable for window/split type AC 1.5 TR /2.0 TR capacity all as specified and directed by Engineer-in-Charge. (Make : As per existing Make at the site of work)
20
-
-
All as item Srl No 26 above but cooling coil.
20
-
-
S&F, in replacement, complete wiring kit suitable for 1.5 TR /2.0 TR windows type ACs/ water coolers complete all as specified and directed by Engineer-in-Charge.
10
-
-
Disconnecting, dismantling and taking out the non-functional Water coolers of any description, any make and in any position, capacity 20 ltrs to 150 ltrs, including water connections, single phase, 50 Hz, strip opening, cleaning and servicing of the water cooler with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing,re-assembling water cooler, restoring water supply connections and testing of the water coolers complete all asl specified and directed by Engineer–in–charge.
Note :-(i) The rate for above item shall be deemed to include for transportation to & from the site of work to MES workshop as indicated by Engineer-in-charge for necessary repairs and testing of water coolers at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one. (ii) Refrigerant gas will be measured and paid for separately under the relevant item of this BoQ. (iii) Visiting charge and Service charge of mechanic shall be deemed to be included under this item and No extra payment will be made to the contractor for mechanic visit.
50
-
-
M&L for repair of water coolers chiller tank with replacement of unserviceable/leakage copper pipe in existing copper pipe size and brazing, pressure testing, insulation of system with glass wool/ PUF, vaccumising and gas charging complete all as specified and directed by Engneer-in-charge. Note:-Refrigerant gas shall be measured and paid for separately against relevant item of this BoQ.
20
-
-
S&F, in replacement, new sealed unit compressor as of existing capacity, description, make & model and connecting to suction/discharge of existing system with and including vacuum and pressure leakage testing with nitrogen gas in appropriate pressure and quantity complete all as specified and directed by Engineer-in-Charge. (Make : As per existing Make at the site of work.) Note:-Refrigerant gas for leakage testing will be measured & paid for separately under relavant item of this BOQ.
-
-
-
Refrigeration compressor suitable for 80 ltrs capacity.
8
-
-
Refrigeration compressor suitable for 60 ltrs capacity.
8
-
-
Refrigeration compressor suitable for 40 ltrs capacity.
8
-
-
S&F, in replacement, capacitor 40/60 mfd, 60/80mfd complete all as specified and directed. (Make : As per existing Make at the site of work.)
20
-
-
S&F, in replacement, Running capacitor 10 to 15 MFD complete all as specified and directed. (Make : As per existing Make at the site of work.)
20
-
-
S&F, in replacement, Running capacitor 20 to 25 MFD complete all as specified and directed. (Make : As per existing Make at the site of work)
10
-
-
S&F, in replacement, Thermostate, 220 volts for water coolers complete all as specified and directed. (Make : As per existing Make at the site of work)
20
-
-
S&F, in replacement, over load protector suitable for water coolers as per existing Make/Size complete all as specified and directed.
20
-
-
S&F, in replacement, water cooler Ball Cock Set/Float Valve Set, of 15mm dia size suitable for any capacity of water cooler complete all as specified and directed.
20
-
-
S&F, in replacement, CP brass self closing and Push cock, 15 mm dia (ISI marked) complete all as specified and directed.
50
-
-
S&F, in replacement, brass Nipple 15 mm dia for inlet and out let connection of water cooler, any type/size including one PVC connection 15 mm size with brass coupling on both ends as per existing Make at site complete all as specified and directed.
50
-
-
S&F, in replacement, AC electric condenser motor 1/35 HP or 1/32 HP, 230 Volts, single speed complete all as specified and directed. (Make : As per existing Make at the site of work)
30
-
-
S&F, in replacement, AC electric condenser motor 1/83 HP, 230 Volts, and single speed complete all as specified and directed. (Make : As per existing Make at the site of work)
30
-
-
S&F, in replacement, PVC flexible drain pipe, OD size 36mmx300mm with one end circle clip complete all as specified and directed.
100
-
-
M&L, in replacement, the body of the desert coolers/ water coolers i.e. in bottom / top / frame etc. including fixing in required size angle iron/ flat iron with welding works, using new, 18 SWG, MS black sheet, cut to size, made to shape and size including necessary mouldings etc and fixing and riveting /bolting with existing parts / portion of the water cooler complete all as specified and directed by Engineer-in-Charge.
50
-
-
Disconnecting and taking out the defective / non-functional desert cooler of any description and in any position, installed at any floor at direct approach ( where any ladders and other T&P are not required to remove the desert cooler from position), strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler, taking out and removing unserviceable / defective parts & internal wiring and re-assembling & testing of the desert cooler complete all as specified and directed by Engineer-in-Charge
50
-
-
S&F, in replacement, PVC switch board with and including piano type switch 5 amp - 2 Nos, 1 way and 1 No selector switch 4 way, 15 Amps, 230 Volts for speed control and One Red indicator including wiring complete all as specified and directed.
40
-
-
S&F, in replacement, desert cooler with submersible/Vertical Pump, 230 volts, 45 watt complete all as specified and directed by Engineer-in-Charge. (Make : As per existing Make at the site of work)
250
-
-
S&F, in replacement, Fan motor with blade suitable for desert cooler of any capacity complete all as specified and directed by Engineer-in-Charge (Make : As per existing Make at the site of work)
100
-
-
M&L, in replacement, wood wool pads in required size as approved (three in each desert cooler) complete all as specified and directed.
100
-
-
M&L,in replacement, front grills of any description and in any position with supplying and fixing new grills of existing shape and size, made of 20 SWG, PGI sheet complete all as specified and directed by Engineer-in-Charge.
80
-
-
M&L for preparation of the steel surfaces and applying two coats of synthetic enamel paint, spray painting for the followings :
-
-
-
Water cooler, any make and any size.
30
-
-
Desert cooler, any make and size.
200
-
-
Refrigerator 165 litres.
30
-
-
S&F, in replacement, new sealed unit compressor of capacity, description make & model as per existing at site, and connecting to suction/discharge of existing system with and including vacuum and pressure leakage testing with nitrogen gas in appropriate pressure and quantity complete all as specified and directed by Engineer-in-Charge. Note:-Refrigerant gas shall be measured & paid for separately under relavant item of this BoQ.
-
-
-
Refrigerator compressor suitable for 165 ltrs capacity .
10
-
-
Refrigerator compressor suitable for 260-286 ltrs capacity.
15
-
-
Refrigerator compressor suitable for 300 ltrs capacity.
10
-
-
Refrigerator compressor suitable for 310-320 ltrs capacity.
10
-
-
S&F, in replacement, Danfoss scroll compressor Model No-SM 147 suitable for 11/17/22 TR Package AC Plant complete all as specified and directed.
4
-
-
S&F in replacement centrifugal condensor pump 5 HP Model No-2DM6-W/BR Make Beacon. U/S condensor pump will be deposited by contractor in MES Store.
10
-
-
S&F, in replacement, following parts suitable for refrigerator/deep freezer of any description and capacity 165 ltrs to 330 ltrs :-
-
-
-
Electric fan motor with complete accessories suitable for frost free refrigerator/deep freezer (Make : As per existing Make at the site of work)
12
-
-
Thermostat switch with knob 230 volt suitable for any type refrigerator/deep freezer (Make : As per existing Make at the site of work)
12
-
-
Relay PTC/ Box type 220 volt 3 pin / 4 pin (Make : As per existing Make at the site of work)
12
-
-
Pin type / screw type bulb suitable for 165 ltrs to 360 ltrs. (Make : As per existing Make at the site of work)
20
-
-
Ice tray PVC moulded of best quality as approved suitable for 14-18 round/rectangular cubes
50
-
-
Refrigerator freezer coil & freezer complete suitable for 165 ltr to 360 ltr. capacity
20
-
-
Bulb Holder assembly complete as per existing Make and Model at the site of work)
20
-
-
S&F, in replacement, condenser coil suitable for 165 to 360 ltrs capacity refrigerator/ deep freezer of any description and any model. (Note : Fixing, brazing to suction and discharge line and testing, gas charging/filling in refrigerator , deep freezer will be measured and paid for separately under Srl item No. 2 and 3 of this BOQ.)
10
-
-
Disconnecting & taking out existing defective electric motor of ACs/water coolers/Desert Collers/Refrigerators of any description & in any position, 230 volts strip opening for rewinding, removing for rewinding to & from the site of work to workshop as approved by Engineer-in-Charge, rewinding with appropriate size copper super enameled wire including insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc, testing at workshop to the entire satisfaction of Engineer-in-charge and transportation & fixing the motor at site including necessary connecting & testing at site complete all as specified and directed by Engineer-in-Charge.
50
-
-
Disconnecting & taking out following voltage stabilizer of any description and in any position & strip opening, servicing and overhauling of Voltage Stabilizer capacity 0.5 KVA to 5 KVA, single Phase , 50Hz , (Make :- Blue Line/Blue Tech/ Nayar/Intage/Citizen), taking out unserviceable/defective wiring & parts i.e. transformer, PCB,Relay, cleaning and servicing,painting complete, re-fixing at site and testing complete all as specified and directed by Engineer-in-Charge.
-
-
-
0.5 KVA/1 KVA
10
-
-
2 KVA/3 KVA
15
-
-
4 KVA/5 KVA
60
-
-
S&F, in replacement, following parts commonly used in the voltage stabilizer of any capacity & any type, as approved by Engineer-in-charge.
-
-
-
Connector (Connection Terminal)
20
-
-
Control circuit auxiliary transformer
20
-
-
Control circuit main transformer
20
-
-
Volt meter, 0-300 Volt type: Rectangular/Round
20
-
-
PCB holder connector
20
-
-
Indicator lamp Green/Red – 220 volts
20
-
-
Toggle/paino type switch 15 Amp 2 way 220 volts (Make : as per existing model )
20
-
-
PCB for high and low cut off voltage (180-245 volts) at higher side setting.
20
-
-
Time delay relay for voltage stabilizer upto 5KVA capacity
20
-
-
S&F, in replacement, fan blade suitable for window AC /split AC, any type, any make complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, blower for window AC/Split AC, any type and any size and any Make, complete all as specified and directed by Engineer-in-Charge.
25
-
-
S&F, in replacement, thermostat switch Assembly for window type AC, any type and any make complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, filter pad for window AC complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, contactor for split AC condenser unit complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, black foam insulation of adequate thickness over copper tubing of any size complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, copper tube suitable for window type AC for following size :-
-
-
-
3/8”
40
-
-
¼”
40
-
-
½”
40
-
-
5/8”
40
-
-
5/16”
40
-
-
S&F, in replacement, heating kit assembly zigzag type, capacity 2KW for window AC complete all as specified and directed by Engineer-in-Charge.
10
-
-
S&F, in replacement, industrial type three pin earth plug top, 20 Amp and 220 Volt complete all as specified and directed by Engineer-in-Charge (Make : As per existing Make and Model at the site of work)
20
-
-
S&F in replacement of MCB SP capacity 32 AMP 240 volt complete all as specified and directed by Engineer-in-Charge. (Make : As per existing Make and Model at the site of work)
40
-
-
S&F, in replacement, capillary coil with the following size :-
-
-
-
31 (0.031")
40
-
-
44 (0.044")
40
-
-
55 (0.055")
40
-
-
60 (0.060")
40
-
-
S&F, in replacement, suction and discharge valve for split A.C. 1.5/2.0 Ton complete all as specified and directed by Engineer-in-Charge.
25
-
-
M&L for denting and painting of window AC/split type AC complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, relay suitable for water cooler compressor 40/80, 60/120 and 150 Litres complete all as specified and directed by Engineer-in-Charge..
20
-
-
S&F, in replacement, Door gasket for water cooler complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, condenser fan blade for water cooler, any size complete all as specified and directed by Engineer-in-Charge.
15
-
-
S&F, in replacement, condenser copper coil for water cooler capacity 40/80 litrs complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, condenser coil for water cooler up to 120 ltr capacity, operating on 220V and 50Hz,complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, storage water tank for desert cooler, any size (as per existing size and specification) complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, fan Regulator step up type for desert cooler, any size complete all as specified and directed by Engineer-in-Charge.
80
-
-
S&F, in replacement, desert cooler body, made of GI sheet of gauge existing at site complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F, in replacement, plywood 4 mm thick for fixing of desert cooler Including fixing material like nails etc complete all as specified and directed by Engr-in-Charge.(Make: as per existing Make and model at site)
10
-
-
M&L for shifting of split type AC from one location to another location including fixing evaporator unit with gutties/fastner, cutting wall/concrete including arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing and brazing work, connecting drain pipe, making good the disturbed surface complete all as specified and as directed by Engineer-in-Charge.
20
-
-
M&L for shifting window type AC including wooden frame, fixing chase, providing electrical connections complete all as specified and as directed by Engineer-in-Charge
30
-
-
S&F in repairs Framed brackets of angles or tees with web and flanges for water cooler stand cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165.
100
-
-
S&F MS stand factory made suitable for condensing unit of split AC unit 1.5/2.0 TR duly power coated complete all as specified and directed
20
-
-
S&F, in repairs, 15mm bore GI tubing 'medium grade' with all fittings and fixed to walls and ceilings or laid in floors complete all as specified.
100
-
-
Same all as item Srl No. 88 above but 20 mm bore
100
-
-
S&F, in repairs, Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed pipe 15 mm bore complete all as specified and directed by Engineeer-in-Charge.
40
-
-
Supply and fix, in replacement, metal plug top 2 pole and earth 240 volts complete all as specified and directed by Engineer-in-Charge .
30
-
-
Supply and fix, in replacement, metal Socket 2 pole and earth 240 volts complete all as specified and directed by Engineer-in-Charge .
30
-
-
S&F sheet metal enclosure with socket plug top and MCBs, Single pole and neutral with a two pin and earth plug and socket complete and one double pole MCB complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F MCB TP 240 Volts , 32 Amps complete all as specified and directed by Engineer-in-Charge.
20
-
-
S & F, in repairs, Power contactor ML-1.5 , 3 pole rating not less than 40 A with 230 coil complete all as specified. (Make: as per existing Make at site)
20
-
-
S & F, in repairs, Power contactor ML-2, 3 pole rating not less than 40 A with 230 coil complete all as specified. (Make: as per existing Make and Model at site)
20
-
-
S&F, in repair, twin core flat 3/0.66 sheathed copper conductor 1100 volts grade conforming to IS:694/2010 complete all as specified and directed.
200
-
-
M&L for writing letters or figures of MES NO/MES ASSETS on split /window type AC, Desert Cooler, Deep Freezer and Water Cooler(Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme complete all as specified and directed by Engineer-in-charge.
200
-
-
M & L for Wet Cleaning of Split Air Conditioner, both Indoor and Outddor Unit, by using Soft cloths, Mild detergent, Water, Spray bottle, Soft brush or toothbrush, Coil cleaner using Plastic sheeting or AC cleaning cover (to catch water) and Garden hose . Taking out the filters and washing them with warm water and mild detergent. Rinse thoroughly and dry completely, Filling a spray bottle with water and a small amount of mild detergent. Spraying the evaporator coils generously. allow the solution sit for a few minutes to loosen the dirt. Use a soft brush or toothbrush to gently scrub the coils, removing any dirt and debris. carefully without damaging the fins. Wiping the blower with a damp cloth or use a soft brush to clean it. Avoid getting water into the motor area, Also Cleaning the Outdoor Unit: by Spraying the condenser coils with water using a garden hose. If the dirt is stubborn, a coil cleaner spray to be used and follow the instructions. Rinsing the coils thoroughly with clean water to remove all cleaning solution and dirt. Using a soft brush to clean the fins. If they are bent, carefully straighten them with a fin comb. Ensuring the drain pipe is clear and not blocked. flushing it with water to remove any clogs. Once everything is cleaned and dry, reassembling the indoor unit and turn on the power complete all as specified and directed by Engineer-in-charge. Note : This item shall not be considered for those Air conditoner (any type) which are already considered for repair & maintanence under this contract.
150
-
-
Schedule of credit amount of Rs 199899.00 to be deducted during AOC
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%