Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Eprocure
Opening Date13 Jul 2024
Closing Date12 Sep 2024
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665773_1Bid Award Id
ViewTender No
8436/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
(c ) Exceeding 1.5 M and n. exc 3.00 M depth
900
-
-
Opening & cleaning of blockage from kitchen /bath traps or WC any pattern by rodding or manually upto and including Ist manhole and making it functional complete all as directed and by Engineer-in-charge
1100
-
-
Cleaning of manholes of any size but depth not exc 1.5 M deep mechanically or manually by taking of sludge/any deletrious material from the existing manhole and removing the sludge to a distance beyond 2.00 KM from the habitation in sealed container and depositing the same all as specified and directed by Engineer-in-Charge
400
-
-
All as per item No 3.00 here-in-before but depth of man hole exc. 1.5 mtr and n. exc. 3 mtr deep.
130
-
-
Cleaning of septic tank/Manhole/Soakage wells of any size/shape/dia and depth by bowling/pumping out water, taking out liquid sludge,sludge clay and other rubbish by means of mechanical suction motor mounted on vehicle and removing to a place outside of MOD land in closed container and dumping bin at low lying area as notified complete all as specified and directed.The top of septic tanks and surrounds shall be washed with clear water after cleaning and sprinkling with fresh unslaked lime to make it hygeinic Note:- The rates are deemed to include the cost of pumping, transportation complete. Contractor may use vehicle mounted closed container without any price adjustment
200
-
-
M &L for Punchering existing RCC /SGSW pipe line of any dia and at any places between manholes for cleaning blockage in pipes including necessary exavation, returning, filling in and removal of soil and making good punchered area with CM 1:1, including cutting/clearing away grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, along pipe lines both sides upto a distance 2m complete all specified as directed.
100
-
-
Demolition of brick work built in cement mortar and incl all quoins, arches, pillars etc complete all as specified and directed
8
-
-
M&L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 all as specified and directed.
7
-
-
M&L for brick work but except brick straight or curved plan exc 6m mean radius built in cement mortar 1:6 all as specified and directed
1
-
-
Taking down of cement plaster inculding wall finishes in any description on brick or stone wall etc., incl hacking out joints for key scrubbing down with water etc. all as specified and directed
500
-
-
M&L 10mm thick rendering in CM 1:6 on fair faces of bricks, finished even & smooth without using extra cement complete all as specified and as directed by the Engr-in-Charge
250
-
-
M&L 15mm thick rendering in CM 1:4 on fair faces of bricks, finished even & smooth without using extra cement and including water proofing compound complete all as specified and as directed by the Engr-in-Charge.
Note: Water proofing compound shall be measure and paid for separately as supply only.
300
-
-
Supply only water proofing compound etc all as specified.
11.14
-
-
M&L for preparation of newly plastered surface of wall and applying three coats of white wash to wall complete all as specified and directed.
250
-
-
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint over a coat of alkali resistant primer of approved shade/tint complete all as specified.
300
-
-
Demolition of reinforced cement concrete as cover slabs for manhole, septic tank and soak well etc (reinforcement cut as reqiured to faciliate demolition) complete all as specified and directed.
5
-
-
M&L for precast RCC 1:2:4 type B 1(Using 20 mm graded aggregate) as in cover slab for manhole/ drains etc with plane faces complete all as specified and directed by Engineer-in-Charge.(Note: Reinforcement to be paid separately)
5
-
-
M&L TMT bars 6 mm to 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
250
-
-
M&L TMT bars 10 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
200
-
-
M&L PCC 1:2:4 type B-0 (using 20mm graded stone aggregate) as in coping, benching ,kersbs compelet all as specified and directed
2
-
-
S& F 200 mm bore reinforced concrete pipes class NP-2 laid and jointed in trenches complete with collars including demolition and breaking up 150 mm bore drain pipe (CI/RCC/SGSW) Complete all as directed and specified.
50
-
-
S& F 150 mm bore reinforced concrete pipes class NP-2 laid in trenches and jointed complete with collars including demolition and breaking up 150 mm bore drain pipe (CI/RCC/SGSW) complete all as spd and as directed.
150
-
-
M&L concrete bed to drain pipe of PCC 1:4:8 type C2 using 40 mm graded stone aggregate for drain pipes bedding & hunching against the sides complete after pipes are laid, jointed and tested complete as specified
-
-
-
(a) 150mm
150
-
-
(c) 200mm
50
-
-
M&L for Cutting into existing manholes of 150 mm internal dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete
50
-
-
Taking down rain water pipes ( any size or pattern) incl all fittings , shoes, bends, swan neck etc. and removal to store
200
-
-
S&F PVC (SWR) pipes single socketed in any length with rubber rings joints laid in fixed to walls including clamps of the following bore etc all as specified.
-
-
-
(a) 75mm
50
-
-
(b) 110mm
75
-
-
S&F cast iron soil, waste and vent pipes in any length with or without ears, with cement joints fixed to walls etc all as specified.
-
-
-
(a) 75mm
30
-
-
(b) 110mm
45
-
-
S&F PVC (SWR) pipe bend with accessable door of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface .
-
-
-
(a) 75mm
12
-
-
(b) 110mm
15
-
-
S&F PVC branch pieces, single (equal or unequal),ordinary or inverted (spigot or socket type)or with parallel/ branches etc all as specified.
-
-
-
(a) 75mm
10
-
-
(b) 110mm
12
-
-
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including replecement of cast iron 100mm P trap and connection to trap and flush pipes etc and lime concrete bedding complete all specified.
5
-
-
S&F in repair vitreous china wash down water closet pan pedestal pattern white (excluding fixing bolts, flushing cistern) including flush pipe of polyethylene of low or high density or PVC, 32 mm dia, for low level cistern etc all as specified and directed.
5
-
-
S&F plastic water closet seat cover black/white, closed pattern with flat bottmom & cover and aluminum anodised hinging device all as specifed and as approved.
5
-
-
S&F in repairs vitreous china wash hand basin, white, flat back of size 550 x 400 mm excluding taps, waste, chain and plug porcelain stopper but including brackets incl cutting for and pinning in ends of brackets or erecting stand incl 32 mm dia pvc waste pipe and 32 mm dia waste co.upling etc complete all as specified.
5
-
-
S&F in repair Brass Chromium plated Wash Hand Basin mixer 15mm dia for mixing hot & cold water screwed down for iron pipe complete all as specified & directed.
5
-
-
Supply and fix in repairs of PVC flushing cistern 10 ltr capacity, valve less syphonic action type low level with and incl ball valve float & handle, waste pipe & fixing accesseries to wall complete all as specified and directed.
10
-
-
S&F in repair 15 mm dia bore cast copper alloy chromium plated fancy type angle stop cock screwed down, high pressure with capstan head, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
10
-
-
S&F in repair 15 mm dia bore bib taps cast copper alloy with fancy type, chromium plated capstan head screwed down, screwed for iron pipe, or for brass ferrule and fixed complete all as specified and as directed.
10
-
-
S&F in repairs PVC connections 15mm size of PTMT of 450mm long. complete all as specified and directed.
50
-
-
S & F in repair fancy type pillar tap 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and as directed.
5
-
-
S&F stainless steel grating 125 mm dia with waste hole fixed in cement complete all as specified and directed.
50
-
-
S&F PTMT waste pipe 32 mm bore of length up to 80 cm for WHB / sink/unrinal pots, complete all as specified and directed.
100
-
-
Dismantling floor hearth or wall tiling incl cement mortar bedding but not backing & rubbish off the premises complete all as specified and as directed by the Engineer -in - charge
75
-
-
M&L for non skid coloured/printed ceramic tiles 7-8 mm thick area of each tile exceeding 0.06 Sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over 15 mm thick screed bed or bedding layer 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed by the Engineer -in – charge
30
-
-
M&L glazed ceramic tiles (450X350 mm size) 6-7 mm thick coloured for work on vertical surfaces such as skirting and dado/riser etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over 10 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces as in backing for tiles in dados/skirting complete all as specified and as directed by the Engineer -in – charge
45
-
-
S&F of 15 mm bore steel tubeing medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors etc including taking down 15mm dia GI tubing and connections complete all as specified and as directed.
30
-
-
S&F of 20 mm bore steel tubeing medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors etc including taking down 20mm dia GI tubing and connections complete all as specified and as directed.
50
-
-
Cutting chases, pining in, making good to facing where required and pointing in CM 1:3 for concealed water tubing making good, cutting exc 10cm but n.exc 20cm girth in brick walls all as specified.
30
-
-
S&F rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed top),triple layer construction, ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with all fittings such as dead plugs and checknuts etc. of 20 mm dia including dismantling of old PVC tank (Capacity 500- 1000 Litres) & removing to where directed complete all as specified and as directed.
5
-
-
S&F ball/ float valves high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe and fixed 20mm bore pipe minimum weight 210 gms complete all as specified and as directed.
5
-
-
Excavation in trenches in soft/loose soil n exc 1.5 M wide & n exc 1.5 M in depth and getting out in soft/loose soil for shafts, wells, man holes and for sewage lines and foundation etc n exc 10 Sqm on plan all as specified.complete all as specified and as directed by the Engineer-in-charge
100
-
-
Returning, filling in including spreading leveling watering and well ramming in layers n exc 25 cm thick all as specified and directed by Engineer-in-Charge.
10
-
-
Removing excavated material to a distance exc 250.00 M but n exc 1.50 Km and depositing where directed at a level n exc 1.50 KM above starting point complete all as specified and directed by the Engineer -in-charge.
90
-
-
Dismantling of mild steel or wrought iron work of any description not otherwise provided for complete all as spd
4
-
-
Dismantling asbestos cement corrugated sheets in roof covering complete all as spd and directed.
400
-
-
M&L Roof trusses (framed ), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to IS 1161-1979 Fe-410 W Gde E-.250 complete all as specified and directed.
400
-
-
S&F Pre-painted galvalume aluminium zinc coating GI based semi corrugated steel sheet 0.50 mm thick of an approved colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed by Engineer-in Charge.
365
-
-
S&F Pre-painted galvalume aluminium zince coating GI based semi plain steel sheet 0.50 mm thick of an approved colour having tensile strength of 550 mpa as in ridge, fixed with self tapping screws all as specified and directed by Engineer-in Charge.
35
-
-
M&L Preparation of steel surfaces of any description,over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide/ zinc chromate complete all as specified.
25
-
-
Demolition of cement concrete in ground floors and pavings not exc. 15 Cm thickness (below/above ground level) including floor finishes all as specified and directed
7.5
-
-
M&L 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded stone agg) as in plinth Protection, flooring finished even and smooth without using extra cement complete all as specified and directed.
100
-
-
Demolition of sunken slab floor of WC and Bath including WC trap etc incl taking down loose filling of aggregate any type and removing where direted and providing water proofing treatment of sunken slab in following steps:-
(a) 15mm thick rendering on vertical sides of RCC slab in CM 1:3 mixed with WP chemical of make Sika/Fosroc/M/s Choksey or equivalent as per manufacturer instructions. (b) Cleaning the concrete surface by brushing and watering and removing all surface inperfections. (c) Fixing 40mm dia Pipe 450mm long to the bottom of the sunken and wraping of bath seal tape on the pipes inserted through walls to floor and seal it (Bath seal tape product of Sika/Fosroc/M/s Choksey or equivalent and grouting around the inserted pipes by porable Sika/Fosroc/M/s Choksey or equivalent bath seal grout as directed. (d) Make angle fillets by mixing sand cement mortar with WPC of make Sika/Fosroc/M/s Choksey or equivalent on all corners. (e) Brushing neat cement slurry two coats with high performance cementitious polymer water proofing coating of Sika/Fosroc/M/s Choksey or equivalent bath seal WPC of thickness 1mm in combination of WPC and cement (1:1.5) by vol and providing upto height 15cm from bottom slab and allow it dry completely. (f) Providing PCC 1:4:8 type D-2 using 40mm graded stone aggregate mixed with WPC of Sika/Fosroc/M/s Choksey or equivalent as per mnufacturer's instructions in sunken slab over brick bat . (g) Fill the sanitary gaps with Sika/Fosroc/M/s Choksey or equivalent sealing compounds complete.
20
-
-
Cutting of trees' roots penetrated into manholes /sewage line /trap etc of any girth and at any depth including application of hot bitumen to arrest sprouting and filling up the gap and making good the disturbed portion with cement mortar1:3 complete all as directed by Engineer-in-Charge
100
-
-