Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date15 Oct 2024
Closing Date18 Dec 2024
Tender Amount₹ 42,37,000
Costs
EMD
₹ 84,740Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679647_1Tender No
8473/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removing excavated soil material exc 250 m and n exc 500m and depositing where directed complete all as specified and directed.
46
-
-
... More
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm.Complete all as specified and directed.
91
-
-
... More
M&L for plain cement concrete1:4:8 type D2 (using 40mm graded crushed stone aggregates) as in foundaion filling etc, complete all as specified & directed
10
-
-
... More
M&L for reinforced cement concrete M-25 design mix using 20 mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
35
-
-
... More
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter and fair finished surface complete all as specified and directed.
150
-
-
... More
S&F Pre-painted galvalume aluminium zince coating GI based corrugated steel sheet 0.50 mm thick of an approved colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed by Engineer-in Charge.
365
-
-
... More
S&F Pre-painted galvalume aluminium zince coating GI based corrugated plain steel sheet 0.50 mm thick of an approved colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed by Engineer-in Charge.
25
-
-
... More
S&F TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
2500
-
-
... More
S&F TMT bars but 6 to 8 mm dia as in stirrups cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
600
-
-
... More
S & F MS screw, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut exceeding 12 mm and not exceeding 20 mm long and dia complete all as spd and directed.
35
-
-
... More
S&F mild steel work as in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed
1500
-
-
... More
S&F for plate girder or single stanchions, built up of one beam or channel section with flange plates, caps,bases. splices, angle brackets,cleats and other connections conforming to Fe-410 W Gde E-250 complete all as specified and directed.
17500
-
-
... More
M&L for two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth.complete all as specified and directed
320
-
-
... More
S& F 6 mm thick aluminium composite panel fixed to framed work and the joints of all panels around the frame shall be made seamless from all sides with the use of silicon or as per manufacturers instructions complete all as specified and directed.
300
-
-
... More
S & F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
155
-
-
... More
S&F 100 mm bore PVC (SWR) bends and fixed in position with adhesive complete all as specified and directed.
30
-
-
... More
S& F framed work such as Joist, channel, angle, or tee sections,
fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410 Gde E-250 complete all as specified and directed.
90
-
-
... More
M&L for writing letters fabricated out of stainless steel sheet not less than 0.90mm thick and not less than 4 CM in width.The overall height of letters shall not be less than 30 CM and shall be fixed on aluminium composite panel as per manufacturers instructions complete all as specified and directed.
44
-
-
... More
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including surface /concealed PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
NOTE : (i) The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers)
22
-
-
... More
M & L for switch flush type single pole one way 16 Amps, 240 volts, white ivory finish complete all as specified.
14
-
-
... More
S&F switch socket combination multi purpose, 6 Pin 6/16 amps, flush typeWith Indicator complete all as specified and directed.
8
-
-
... More
M&L for ceiling rose surface Bakelite two to three terminal, 18 x 50 mm complete all as specified.
14
-
-
... More
Supply, fixing, connecting and testing 100Watts LED highbay luminiare having fin ventilation technology for better thermel management and with cutting edge LED technology seeks to various industrial applications IP66, including clamps, nuts, bolts for fixing arrangement detachable type on wall, trusses with double fixing arrangement etc and connecting the same to electric source with using 2.5 Sqmm (nominal area) stranded copper conductor, three core, PVC insulated & sheathed cable, 1100 volts grade complete all as specified and as directed.
14
-
-
... More
S&F air circulating fan wall mounted, AC, single phase, 230 V, of size 450mm sweep (Steel Body) and connecting up including connecting the same to electric source with using 1.5 sqmm (nominal area) stranded copper conductor, three core, PVC insulated & sheathed cable, 1100 volts grade complete all as specified and as directed.
8
-
-
... More
Supply and fixing of sheet metal enclosure Double door for DB’s 12way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified and directed
1
-
-
... More
S&F MCB/Isolators single pole 6 to 32 Amps, "C" Curve, 240 Volts complete all as specified and directed.
10
-
-
... More
S&F MCB/Isolator Single pole and neutral 40 to 63 Amps, 240 Volts complete all as specified and directed.
1
-
-
... More
Supplying and laying testing and commissioning LT cable XLPE insulated armoured, heavy duty, aluminium conductor cable 10 Sqmm 4 core, 1100 volt grade fixed on walls, roof, ducts with suitable steel saddles complete all as specified and as directed.
50
-
-
... More
Excavation in trenches n exc 1.5 mtr wide and not exc1.5 mtr depth for foundation and laying of cable, erection of RCC poles and getting out in soft /loose soil etc complete all as specified and directed.
10
-
-
... More
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point.
3
-
-
... More
M&L dry river sand in trenches for cable cushioning & protection including spreading, ramming all as specified and directed.
Note: Punned thickness shall be measured and paid.
3
-
-
... More
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
0.29
-
-
... More
S&F aluminium air termination rod single pointed at top and properly threaded at bottom end, 300 mm long, 12mm dia complete all as specified & as directed.
6
-
-
... More
S&F light grade 40 mm dia GI water tubing for protection of earth strip upto test point complete all as specified & as directed.
40
-
-
... More
M&L for 40mm dia GI pipe light grade 1.2 m long duly threaded on one end for fixing socket reducer, with and including socketg reducer of sixe 40 x 25 mm as a air termination stand/post including aluminium gutaka complete all as specified & as directed.
6
-
-
... More
S&F earth continuity conductor 25 x 3.15 mm aluminium strip with saddles and fixing on insulators including brass nut bolts and washers for roof conductors and down conductors above ground complete all as specified & directed.
80
-
-
... More
M&L for providing test point terminal block made out of gun metal or phosphorous bronze of size 75 mm x 75 mm x 25 mm long hexagonal head screws complete all as specified & as directed.
2
-
-
... More
M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI strip 32x6mm as erthing lead by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing complete all as specified & directed.
4
-
-
Evaluation Notes How It Works ?