Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Oct 2024
Closing Soon23 Nov 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680623_1Tender No
8710/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolition of cement concrete unreinforced in ground floors and pavings n.exc.15 cm thickness (below or above ground level) complete all as specified and directed.
5
-
-
M &L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in filling & mass concrete complete all as specified and directed.
10
-
-
M &L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in coping of pole ect including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
10
-
-
M&L for cutting/trimming the trees branches size n.exc 80 mm dia at height of exc. 3 mtrs but not exc 12 mtrs crossing/touching/embracing the overhead lines of HT/LT and obstructing the uniform electric power supply incl. Removing the same from site to a distance exceeding 50 mtrs. complete all as specified and directed.
12
-
-
All as per Item No - 19 but here-in-before of tree branches size exc. 80 mm and not exc. 150 mm dia complete all as specified and directed.
8
-
-
M & L for excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out in soft/loose soil complete all as specified ad dirtected.
80
-
-
M & L for returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25 cm all as specified ad dirtected.
30
-
-
M & L for removing excavated materials not exc 50 mtr and depositing where directed at a level n exc. 1.5 M above complete all as specified ad dirtected.
50
-
-
M & L for unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified.
Note : maesurement shall be done after puning down of sand.
6
-
-
M & L for Fly Ash bricks Sub-class 'B' locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.
2000
-
-
M & L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 32 mm dia with all fittings.
10
-
-
All as Per Item No - 14 but here-in-before of size 40 mm dia complete all as directed.
25
-
-
All as Per Item No - 14 but here-in-before of size 50 mm dia complete all as directed.
20
-
-
All as Per Item No - 14 but here-in-before of size 80 mm dia complete all as directed.
15
-
-
Taking down existing old Extg unserviceable LT UG/service cable of any description and size complete all as specified and as directred.
580
-
-
S& F XLPE insulated armoured and PVC sheated heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size note- rate is inclusive of cable gland & cable lugs.
-
-
-
2 core x 10 sq mm
100
-
-
4 core x 10 sq mm
100
-
-
3.5 core x 70 sq mm
100
-
-
3.5 core x 95 sq mm
100
-
-
3.5 core x 120 sq mm
100
-
-
3.5 core x 150 sq mm
80
-
-
M & L for repair/maint of floor indoor/outdoor cubical type LT Feeder Pillar Box of various sizes including disconnecting all in-coming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size incl. and segregating the serviceable and un-serviceable items with removing old burn out wiring and re-fixing the existing position replacement of un-serviceable parts including re-wiring and PCC works around the Feeder Pillar Box complete all as specified and directed.
4
-
-
S & F of MCCB 63 Amps, 4 Pole, 415V, with breaking capacity 16 KA complete all as specified and directed.
3
-
-
S & F of MCCB 100 Amps, 4 Pole, 415V, with breaking capacity 16 KA complete all as specified and directed.
4
-
-
M & L for MCCB 4 Pole, 415V, Adjustable type 160 Amps with breaking capacity upto 18 KA complete all as specified and directed.
3
-
-
M & L for MCCB 4 Pole, 415V, Adjustable type 200 Amps with breaking capacity upto 18 KA complete all as specified and directed.
2
-
-
M & L for MCCB 4 Pole, 415V, Adjustable type from 320 A upto 350 Amps with breaking capacity upto 36 KA complete all as specified and directed.
2
-
-
M & L for MCCB 4 Pole, 415V, Adjustable type 400 Amps with breaking capacity upto 36 KA complete all as specified and directed.
2
-
-
M & L for MCCB 4 Pole, 415V, Adjustable type 630 Amps with breaking capacity 50 KA complete all as specified and directed.
2
-
-
Supply and fix ACB 4 Pole, 415 V, beaking capacity 50 KA with Thermal Magnetic Release (Manual Fixed type) of capacity 2500 Amps completed all as specified and directed.
1
-
-
S&F in-replacement of Digital time switch including 3 phase power contactor 40 Amps and taking out old UNSV timer & contactor complete all as specified and directed.
2
-
-
Dismantling and taking down street light fittings any size and re-fixing again after erecting of LT pole etc complete all as specified and directed.
5
-
-
S & F Cable junction box for street lights of size 155 x 210 x 92 mm IP 66 with integrated membranes/metric knockouts for cable entry of 10 to 25 Sqmm LT UG cable suitable for 415 voldts, 50 Hz, 3 phase 4 wire including clamp made out of MS flat 30 x 5 mm, nuts, bolts, washers etc complete and mounted on security light pole complete all as specified and directed. Make ; Hensel cat Part No - DK 2525G with terminals
12
-
-
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with impact and corrosion resistant complete with driver and fixing as arrangement to focus on operating area of operation complete with IP 65/66 protection complete all as specified and directed.
9
-
-
Supply and fixing LED street light fitting 60 watt 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complet with driver, and fixing as arrangement to focus on operating area of operation with brackets/as directed with impact and corrosion resistant including thermal mangement in multiple optics compete with IP 65/66 protection complete and taking down old unsv street light fitting and type and any wattage complete all as specified and directed.
7
-
-
Supply and fixing LED flood light fitting 70 watt 230V AC outdoor type with thermal mangement in multiple optics and equipped with IP66 protection with impact corrosion resistant complete with driver and lamp and fixing as arrangement to focus on operating area of operation with brackets/as directed with impact taking down old unsv flood light fitting and type and any wattage complete all as specified and directed.
6
-
-
Supply install commissioning and testing CPRI Approved factory fabricated, floor mounted outdoor type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame and 750mm above the Normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar 250 Amps rating (01 Set) fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl. necessary PCC (1 : 3 : 6) type C2 as in foundation all as directed, comprising of the following : -
1
-
-
(a) INCOMING
-
-
-
(i) Thermal magnetic and microprocessor release MCCB 250 Amps, 4 Pole, 36 KA with front operated locking device. - 01 Nos
-
-
-
(b) OUTGOING
-
-
-
(i) Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty - 03 Nos
-
-
-
(ii) MCB 32 Amps, 2 Pole. Qty - 01 Nos
-
-
-
(c) Digital time switch including 3 phase power contactor 40 Amps Make : Qty - 01 Nos
-
-
-
(d) (i) Digital Voltmeter 0 - 500 Volts with selector switch - 1 Set.
-
-
-
(ii) Digital Amperemeter 0 - 200 Amps with selector switch - 1 Set.
-
-
-
(iii) Indicator Lamp - R - Y - B (Set of three).
-
-
-
(iv) Frequency meter 40-55 Hz - 01 Nos
-
-
-
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection of GI wire to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for street light poles). Note :- Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
4
-
-
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 mtrs as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
20
-
-
Supply and fix Electrical Insulation Rubber Sheet AS PER IS-15652-2006 Class A - 2MM Thickness. Width 1MTR X Length 2MTR. Color - Blue complete all as specified and as directed.
10
-
-
Supply and fixing in replacement Sealed maintenance free battery tubular type with capacity 12V, 150 AH complete all as specified and as directed.
6
-
-
Supply and fix in replacement of Fountains and Pools 6 LED 18 WATT Full SS SPOT Fountain Light (HF040) with all necessary fixing arrangement as required complete all as specified and as directed.
10
-
-
Supply and fix in replacement 9 W LED Bollard lights complete all as specified and as directed.
12
-
-
S & F LED Post top 25 W made in die cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP-65 protection opal mdiffuser available complete all as specified and as directed.
10
-
-
Supply and fix LED Ultra LED Rope Light 6000 LEDs Warm White as per sample from the site all as specified and as directed.
2
-
-
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served wth inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart inccluding 4 mm susension wire, one twin core aluminium conductor of size 6 Sqmm flat or circular from junction box to street light fitting complete all as specified and directed by engr in charge.
150
-
-
M&L for boring of holes under road/pavement /hard standing by trenchless technology with neccessary machineries for inserting the GI pipe of size upto 80 mm working pressuredia all as directed.
55
-
-
Supply install commissioning and testing CPRI Approved factory fabricated, floor mounted outdoor type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame and 750mm above the Normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar 250 Amps rating (01 Set) fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl. necessary PCC (1 : 3 : 6) type C2 as in foundation all as directed, comprising of the following : -
4
-
-
(a) INCOMING
-
-
-
(i) Thermal magnetic and microprocessor release MCCB 250 Amps, 4 Pole, 36 KA with front operated locking device. - 01 Nos
-
-
-
(b) OUTGOING
-
-
-
(i) Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty - 03 Nos
-
-
-
(ii) MCB 32 Amps, 2 Pole. Qty - 01 Nos
-
-
-
(c) Digital time switch including 3 phase power contactor 40 Amps Make : Qty - 01 Nos
-
-
-
(d) (i) Digital Voltmeter 0 - 500 Volts with selector switch - 1 Set.
-
-
-
(ii) Digital Amperemeter 0 - 200 Amps with selector switch - 1 Set.
-
-
-
(iii) Indicator Lamp - R - Y - B (Set of three).
-
-
-
(iv) Frequency meter 40-55 Hz - 01 Nos
-
-
-
Supply and fix manually on load change over swich 4P, 200 A, 415 Volts complete all as specified and directed.
4
-
-
Supply and fix manually on load change over swich 4P, 160 A, 415 Volts complete all as specified and directed.
2
-
-
Supply and fix manually on load change over swich 4P, 63 A, 415 Volts complete all as specified and directed.
4
-
-
Supply and fix in replacment of the Digital water level indicator for Sump/OHT complete all as specified and directed.
4
-
-
M & L in replacement of submersible pump MU-G 25 FASD Three phase submersible pump Controllers with single phase preventer of 25 HP in sheet-steel enclosure type ML with Wideband coil conf to HSN Code 8536 complete all as specified and directed.
2
-
-
M & L in replacement of submersible pump MU-G 20 FASD Three phase submersible pump Controllers with single phase preventer of 20 HP in sheet-steel enclosure type ML with Wideband coil conf to HSN Code 8536 complete all as specified and directed.
2
-
-
M & L in replacement of submersible pump MU-G 15 FASD Three phase submersible pump Controllers with single phase preventer of 15 HP in sheet-steel enclosure type ML with Wideband coil conf to HSN Code 8536 complete all as specified and directed.
2
-
-
S & F PVC Insulated unsheathed Submersible cable 10 sqmm dia three core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified and directed.
300
-
-
S & F PVC Insulated unsheathed Submersible cable 16 sqmm dia three core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified and directed.
300
-
-
M & L for Lead Wool insullation for packing of CI /DI pipe/ Sluice Valve up to 200mm dia complete to the entire satisfaction of Engr-in -Charge. all as specified and directed.
200
-
-
Supply only High-Quality "Gland Packing Sun Brand" Braided with Graphite for CI/DI/Sluice valve/NRV complete to the entire satisfaction of Engr-in -Charge. all as specified and directed.
200
-
-
Dismantling floor, hearth or wall tiling in-cluding cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
165
-
-
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
35
-
-
Material and labour for Glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 all as specified
50
-
-
Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm th 1:6 cement mortar screed bed complete all as specified and directed.
115
-
-
M & L Granite (Black/Ruby Red ) work (table rubbed and polished) 20 mm thick in cooking platforms bedded and jointed with grey cement slurry and pointed to match the shade of granite stone including grinding and polishing types including screed bed 15 mm thick in CM 1 : 6 .
20
-
-
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 20mm cement mortar screed bed complete all as specified and directed.
83
-
-
M&L for rubbing and polishing old kota stone flooring complete all as specified and directed.
148
-
-
M&L for colour rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with white cement and pigments over 15mm thick cement mortar screed bed complete all as specified and directed.
250
-
-
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed
5
-
-
M&L for Machine pressed precast cement concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade
100
-
-
M&L for Pre-cast cement concrete block (1:3:6)type C1 using 20mm graded stone agg masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete
2
-
-
M&L for preparation of new surface of concrete Surfaces of any description over 10cm girth or width, not otherwise described and applying two coat of synthetic enamel paint complete all as specified and directed.
15
-
-
M&L100 mm thick PCC 1:4:8 type type D2 as in floors as sub base in patches all as specified and directed by Engr-in-charge.
350
-
-
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
5
-
-
M&L FLY ASH Brick work using modular bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
5
-
-
M&L for rendering on fair faces of brick work or concrete surface of wall 10mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed
150.5
-
-
M&L for preparation of new decorated surfaces of walls and applying two coat of oil bound distemper over a coat of birla wall care putty complete all as specified and directed.
150.5
-
-
Schedule of credit amount of Rs. 63551.00 to be deducted during AOC.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%