Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Oct 2024
Closing Soon18 Nov 2024
Tender Amount₹ 20,00,000
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679341_1Tender No
8708/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking out accumulated sludge and foreign particles from screen chamber of STP and depositing to drying bed at distance not exc 25 mtr spreading, levelling complete all as specified and directed.(Note : This operation shall be carried out once in every three months i.e total four time in a year and every operation shall be measured and paid seperately)
16
-
-
Taking out accumulated sludge and foreign particle from the grit channel and its hopper and depositing to drying bed at a distance not exc 50 m spreading, levelling complete all as directed.(Note : This operation shall be carried out once in every three months i.e total four time in a year and every operation shall be measured and paid seperately)
16
-
-
Cleaning and rubbing down with coir string to wall surface of dry and wet sump of STP (Outer wall of dry sump and inner wall of wet sump) washing with clean water complete all as specified and as directed.(Note : This operation shall be carried out once in every three months i.e total four time in a year and every operation shall be measured and paid seperately)
16
-
-
Taking out accumulated sludge and foreign particles from screen chamber of sump-cum-pump house and depositing to distance not exc 50 mtr and spreading, leveling complete all as specifried and directred by Enbgineer-in-charge.(Note : This operation shall be carried out once in every three months i.e total four time in a year and every operation shall be measured and paid seperately)
16
-
-
Taking out accumulated mixture of sludge and sludge water from dry and wet sump of sump-cum-pump house and disposal of the same to the distance not exc 50mtr spreading, levilling etc complete all as directed by Enginer-in-charge.
500
-
-
Cleaning of blockage of Primary & secondary Bio-filter (each bio-filter consists of four arms) nozzle by wire or by opening the nozzle lid complete all as specified and as directed
64
-
-
Taking out accumulated mixture of sludge and sludge water from digester and disposal of the same to a distance exc 10 mtr and not exc 50 mtr to drying bed, spreading, leveling complete all as directed by the Engineer-in-charge
500
-
-
Taking out accumulate dry sludge (Dry manure) from drying beds and removing from site all as directed by Engineer-in-charge
300
-
-
M&L for foundation of non clogging pumping set of capacity 5HP/2 HP/1HP installed at raw sewage pump room including providing PCC 1:2:4 (Type B1) and regrouting of MS Bolts and Nuts and washers after demolition of existing foundation complete all as specified and directed.
2
-
-
Dismantling defective current collector assembly of primary and secondary clarifiers and refixing in position after carrying out servicing/replacement of the following worn-out parts as given below after re-doing all electrical connections complete all as specified and directed. (a) Carbon crush with spring as per existing size and specification - 12 Nos. (b) Carbon brush holder as per existing size and specification - 02 Nos. (c) Cleaning/greasing of centre bearing of clarifier bridge all as directed.
4
-
-
M&L for repair of earthing with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanized earth lead strip 25x4mm (earthing lead from earth electrode to test point upto 7.5m ) by means of bolts, nut, checknuts and washers of galvanized iron or steel all as shown in electrical plate No 5 of MES Schedule Pt-I 1991, GI earth lead strip of size 25mm x 4mm protected by GI pipe 40mm dia light grade and connected to earth test point including excavation & earthwork including testing on completion complete all as specified and directed.
2
-
-
M & L for disconnection of Electrical/Mechanical connection and taking out carefuly of Sewage transfer pump up to 05 HP DOL (3 phase, 415V 50 HZ, AC Supply) from collection tank of any make and rewinding the same with super enameled copper wire of existing gauge/specification making of heat varnishing, greasing and two coat spray/ brush painting with synthetic enemel paint of recommended colour including replacement of bearings NDE and DE as per existing specification and size including refixing the motor in position making all electrical and mechanical connections and testing complete all as specified and as directed . NOT: Rate included taking out pump from the collection tank.
2
-
-
All as per item no 15 here-in- before but capacity 05 HP of Air Blower pump DOL complete all as specified and directed.
2
-
-
All as per item no 15 here-in- before but capacity 02 HP of Filer Feed Pumps DOL complete all as specified and directed.
2
-
-
All as per item no 15 here-in- before but capacity 01 HP of Sludge Pumps DOL complete all as specified and directed.
2
-
-
M& L for replacment of Sewage Agitator motor 0.50HP complete all as specified and directed.
1
-
-
M& L for replacment of Air blower for STP complete all as specified and directed.
2
-
-
M& L for replacment of DOZING PUMP complete all as specified and directed.
3
-
-
Disconnecting all cable connections, dismantle and taking out old unserviceable LT panel board of any type/ size, and remove from the site and making good the disturbed surfaces all as directed and supply, install, testing and commissioning of Supply fabricate, installation and tesing of FPB ,outdoor type 45 cm height from ground to bottom of pillar box, front door with locking arrangement with duplicate keys fixed on top hinges mounted on and including PCC foundation and connecting LT panel cubical flush pattern made out of MS sheet 2 mm with angle iron base frame of size 50mm x 50mm x 6mm for mounting of panel, dust proof, welded steel structure with locking arrangement having TPN copper Bus Bar 200 Amps rating capacity strip fixed with insulators 4 wire system painting of steel work with 2 coats of synthetic enamel paint over a coat of primer comprising of the following:
1
-
-
(a) (Incommer) MCCB 3 pole 100 Amps with breaking capacity 16 KA
-
-
-
(b) (Out going) (i) MCCB 4 pole 63 Amps with breaking capacity 16 KA -02 Nos
-
-
-
(ii) MCB TPN 32 Amps with breaking capacity 42 KA -03 Nos
-
-
-
(iii) MCB, single pole and neutral, 240 Volts , 05-32 Amps-04 Nos all as specified and as directed.
-
-
-
(c) (i) Digital Voltmeter Digital 0-500 Volts - 01 No, with selector switch.
-
-
-
(ii) Digital Ampere Meter Digital - 01 No. with CT and selector switch.
-
-
-
(iii) Phase indicating lamp (RYB) - 01 Set.
-
-
-
(iv) Digital frequency meter 40-60 Hz - 01 Set.
-
-
-
(d) Supply and Fix automatic Star Delta Starter having contractor ML 3, Relay scale 28-12 Amp, HRC fuse 80 Amp and also having all safety devices suitable upto 10 HP, 3 phase motor.-02Nos
-
-
-
(e) Multispan (Single Phase preventor) Voltage Protection Relay 90 X 22.5 X 67.5 (SPP-22 (Din Rail))-01Nos
-
-
-
S&F for of HDPE TANK 200 ltr Capacity complete all as specified and directed.
3
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm 2 core nominal cross section in service connections
100
-
-
Supply and laying in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape , of 3.5 Core Core 25 Sq.mm for connection from LT pannel to Sub LT panel Bus bar , confirming to IS specifications or make: Havells :-
200
-
-
M&L for Cleaning of blockage of GI pipe of 40mm dia to 100mm dai by wire or by opening the pipe lid complete all as specified and as directed
100
-
-
M&L for Painting of CI pipe 100/80mm dia with one coat of black paint after preparation of surfaces
26
-
-
M&L for cutting the bushes, grass, thorney bushes, small plants/trees up to a height of 5 mtr in and around STP south zone and central zone incl surface dressing and removing the waste material to a distance not exceeding 50 mtr from the starting point complete all as specified and directed.
250
-
-
Dismantling of old rusted/corroded and pitted GI nipple fixed on primary/secondary bio-filter arms by electric/gas welding complete all as specified and directed
20
-
-
M& L for replacment of BIO Media complete all as specified and directed.
15
-
-
M& L for replacment of tube Media complete all as specified and directed.
15
-
-
M& L for replacment of filter Media complete all as specified and directed.
4000
-
-
M& L for replacment of carbon Media complete all as specified and directed.
350
-
-
Material and Labour for repair/maintenance of Bleaching Dozer of cap 100 Gallons all as specified and directed.
2
-
-
S&F in repair 'V' belt size A-11 for primary and secondary clarifier bridge motor complete all as specified and directed.
2
-
-
M&L in repair of carbon brush set with copper leads and clip for clarifiers/digester beds all as per existing complete.
10
-
-
M&L in repair of rubber coupling wheel type cotton reinforced suitable for non clogging pumping set of capacity1-5HP all as per existing complete.
6
-
-
M&L in repair for Pump bearing suitable for non clogging Pumping set of capacity 1-5HP/.
2
-
-
M&L in repair of gland packaging 15 mm size for non clogging pumping sets, sluice valves at STP all as specified and ditected.
20
-
-
M& L for replacement of 50 mm dia SS pipe complete all as specified and directed.
40
-
-
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 m in depth in any type of hard/dense soil complete all as specified.
20
-
-
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm complete all as specified.
18.5
-
-
Removing excavated material not exc 50 meters and depositing where directed at a level not exc 1.5 m above the statring point.
1.5
-
-
S&F for framed brackets of angles or tees with web and flanges cut to shape,drilled & counter sunk for screw,incl bending and welding angles,as necessary,guest plates,rivetting etc. for brackets,conforming to Fe 290 Gde E-165 complete incl taking down old existing.
100
-
-
S&F in replacemnt of butterfly valve 50 mm dia bore hand operated of pressure not less than 15 Kg / Sqcm with complete set all as specified and directed.
20
-
-
S&F in replacemnt of MS flanged pipe 100 mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer after provideing with red oxide including specials complete all as specified and directed.
50
-
-
M & L for Pre - insulated MS pipe of size 50mm dia, Class 'C' having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 gauge GI cladding complete suitable for above ground
50
-
-
M&L for painting for outer and inner steel/iron surfaces with applying two coats of synthetic enamel paint (1st grade) over 10 cm in width or girth after preparation of new surface complete all as specified and directed.
350
-
-
Testing of Treated sewage quality for following parameters as per Mannual of Sewerage and Sewage Treatment System, Ministry of Urban Development 2013:- - Tempratuer - pH - TSS - BOD5 at 20 degree C - FC MPN - Helminths Egg - Nitrates as N - Phosphorus as P
4
-
-
Testing of Raw sewage for following parameters as per Mannual of Sewerage and Sewage Treatment System, Ministry of Urban Development 2013:- - Ph value - TDS - BOD - COD - TSS - Oil & Grease - Dissolve Phosphorus - Nitrate (Nitogen as N) - Total Nitrogen - Alkalinity (as CaCO3) - Chloride - Total phosphorus - Potassium (as K2O) - Coliform - Suspended Solids - Faecal Streptococci - Helminthic eggs - Virus (plaque forming units) - Peak Flow - Av Flow - Total Flow in 24 hr
4
-
-
AMC for comprehensive repair and maint of STP of 240 KLD with following specifications:-Sewage Transfer Pump up to 5 HP-01, Air Blower 05 HP-01 Nos, Filter Feed Pump 2 HP-01 NOs, Dossing Pump up 0.50 HP-01 NOs, Agitaor Motor 0.50 HP-01 Nos, MCB 63 AMP TPN-01 Nos ,PVC pipe connection inlet to Doser and outlet to Doser,cleaning of Doser tank, including following repair/maint work also carrying out:- . all as per required and directed by engr- in-charge
9
-
-
Pumps: Repair or replace faulty pumps and check for any leaks or unusual noises.
-
-
-
Blowers: Service blowers and check for motor issues or air leaks.
-
-
-
Valves and Pipes: Repair or replace any damaged valves or pipes to prevent leaks or blockages.
-
-
-
Control Panels: Inspect and repair control panels and wiring issues.
-
-
-
Sensors and Meters: Fix or recalibrate sensors and meters that are not providing accurate readings.
-
-
-
Cleaning of chocked sludge pipe up to 80mm dia
-
-
-
.Note:- (a) Defective items if replaced shall be measured and paid under relavent item.
-
-
-
Schedule of credit amount of Rs. 25581.60 to be deducted during AOC.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%