Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date8 Nov 2024
Closing Soon22 Nov 2024
Tender Amount₹ 43,54,000
Costs
EMD
₹ 87,080Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_670102_3Tender No
8900/1559/GWL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
All as per item no 3 above but at CEO Complex, no of panels-02, No of detectors-190 complete all as specified and directed by Engr-in- Charge
1
-
-
All as per item no.3 above but at WSMT, no of Panels-01 No of detectors-18 complete all as specified and directed by Engr-in-Charge
1
-
-
All as per item no.3 above but at Old 10 Tetra School, no of panels-02, No of detectors-68 complete all as specified and directed by Engr-in- Charge
1
-
-
All as per item no.3 above but at New 10 Tetra School, no of panels-02, No of detectors-268 complete all as specified and directed by Engr-in- Charge.
1
-
-
All as per item no 3 above but at 26 MMPU, no of panels-01, Nos of detectors-20 complete all as specified and directed by Engr-In-Charge.
1
-
-
All as per item no 3 above but at Tech Flight and Central Elint Complex, no of panels-02, No of detectors-125 complete all as specified and directed by Engr-in-Charge
2
-
-
Supply only the Sluice valve 150 mm complete with handle, spindle PN 1.6 Rating complete all as specied and as directed.
2
-
-
Supply only the Sluice valve 100 mm complete with handle, spindle PN 1.6 Rating complete all as specified and as directed.
2
-
-
Supply only the Non return valve 150 mm complete PN 1.6 Rating complete all as specified and as directed.
2
-
-
Supply only the Non return valve 100 mm complete PN 1.6 Rating complete all as specified and as directed.
2
-
-
Annual Maintenance for a period of eleven months of following capacity fully automatic engine start system Fire Fighting Pump sets installed at ATC complete all as specifed and as directed by Engr-in-Charge. The AMC includes monthly preventive maintenance visits and unlimited breakdown calls during the Contract period. The AMC Shall include the following works and services.
a) Cleaning, Oiling,Greasing, topping, calibration, repairs to Main Pump Electric driven, Jockey Pump electric driven,diesel engine driven pump
b) Inspection of Motor Control system with cleaning of all the switch gears and contactors
c) Inspection, testing of entire Hydrant System, Water Sprinkler System through maintenance service Centre having experience in Fire Fighting maintainance or any other agency as approved by GE.
11
-
-
The list of fire fighting eqipments installed is appended below.
1.Motor driven main pump 45KW /60HP, 2500LPM 70M head-02 Nos
2. Motor driven Jockey pump 15HP 2900RPM, 70M head-01 Nos
3.Complete Sprinkler system
-
-
-
Annual Maintenance for a period of eleven months of following capacity fully automatic engine start system Fire Fighting Pump sets installed at Nano Hangar complete all as specifed and as directed by Engr-in-Charge. The AMC includes monthly preventive maintenance visits and unlimited breakdown calls during the Contract period. The AMC Shall include the following works and services.
a) Cleaning, Oiling,Greasing, topping, calibration, repairs to Main Pump Electric driven, Jockey Pump electric driven,diesel engine driven pump
b) Checking the tention in V Belt of any size of diesel engine,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals,bushes, servicing of the water pump, adjustment of fuel firing, repair to self starter,
c) Battery top up with Electrolite solution, arresting the oil leakage and topping up of engine oil, operator interface device OID display,replacement of U/S oil level tube provided on the fuel tank for checking of oil level. d) The tank has to be calibrated and level marked on the tank, cleaning of tank for dust and mud. e) Repair of wiring control panel of diesel engine by checking of condition of control wiring and tightning of screws etc as required at site. DG including repair/Replacement off toggle switch,
f) Inspection of Motor Control system with cleaning of all the switch gears and contactors
g) Inspection, testing of entire Hydrant System, Water Sprinkler System through maintenance service Centre having experience in Fire Fighting maintainance or any other agency as approved by GE.
11
-
-
The list of fire fighting eqipments installed is appended below.
1. Motor driven main pump 75KW/100HP 1450RPM 70M head-01 Nos
2.Motor driven Jockey pump 15 HP, 2900RPM 70M head-01 Nos
3. Diesel driven std by pump 45KW/60HP 1800 RPM, 70M head-01 Nos
4. Complete Hydrant System with UG MS Pipe, Fire Hydrants and Hose cabinets
Note for Item No 02 & 03 : The AMC of fire fighting system shall also include the following monthly checks
1. Cleaning, Checking and operating all fire pumps. Checking noise, vibration and temperature of the pumps in their working state. 2. Cleaning, Checking electrical Control Panel (MCC) of the fire pumps.
3. Checking of Engine Driven Starter Panel, Servicing of Fire Diesel pump At the interval of 06 Month
4. Checking of Volt Meter; Amp meter; Starter etc.
5. Checking of batteries, fan belt, temperature gauge, Fuel gauge etc. of diesel generator fire pump. 6. Greasing of pump shafts
7. Overhauling of all Pumps if required
8. Cleaning of all pumps and its accessories.
9.Checking & servicing of Strainers, Gate / Butterfly Valves, Non return Valves, Air Vessel, Pressure Gauges, Pressure Switches and other related accessories therein.
10. Checking of Diesel Tank flow pipe condition, Display pipe condition.
-
-
-
Annual Maintenance of Beam Master/flame detector system installed at TACDE Hangar complete with Addressable control module,addressable monitor modules,manual call point and addressable electronic sounder cum strobe, short circuit isolators, electronic siren,PA system complete with monthly health checkup of entire system and unlimited breakdown calls complete all as specified and as directed.
Note: The AMC includes checking of different accessories of beam/flame detectors installed at a height of 10m.
2. The AMC includes monthly checks of the system by a qualified technician of reputed company approvedby GE.
3. Monthly testing of the entire system as per IS in the presence of user and Engr-in-charge is deemed to be included in the quoted rate.
4. Items which are recommended to be replaced will be measured and paid separetely under relevant items.
11
-
-
Supply only flame detector includng power uniit and module complete all as specified and directed.
1
-
-
Supply only addressable control module complete all as specified and as directed.
4
-
-
Supply only addressable monitor module complete all as specified and as directed.
3
-
-
Supply only Addressable electronic sounder cum strobe complete all as specified and as directed..
1
-
-
Supply only Remote response indicators complete all as specified and as directed.
40
-
-
Supply only in replacement Fire Alarm sounders / Sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 1000 meter range complete all as specified and as directed.
1
-
-
Supply and replacement Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and as directed.
10
-
-
Supply only hose reel drum 30m complete all as specified and as directed.
10
-
-
Supply only Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type complete all as specified and as directed.
15
-
-
Supply only Yard hydrant Post / Stand Post 80mm Dia GI / MS both flanged type 1.5m Height complete all as specified and as directed
10
-
-
Supply only Detectors Complying with and type certified to EN - 45 Addressable/ Non addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and as directed.
150
-
-
Supply only Singal Hydrant Gun Matal 63mm Dia with Water Tigghtness test :-14kgf/cm2 and Hydrostatic Test :- 21kgf/cm2 and Flow test :90 LPM min at :7kgf/cm2 .LPMm(Make :New Age ,Min Max Mtech) ISI Marked complete all as specified and as directed.
10
-
-
Supply only fire hydrant valve double headed complete all as specified and as directed.
4
-
-
Supply only RRL Hose pipe 63mm Dia 15mtr Gun Metal Male/Female Coupling with working pressure : 200 PSI Test Pressure: 300 PSI and Burst Pressure :500 PSI . (Make :New Age ,Min Max ,M Tech ) ISI Marked complete all as specified and as directed.
10
-
-
Supply only battery charger for diesel fire pump complete all as specified and as directed.
1
-
-
Disconnecting, dismantling and taking down unserviceable burnt jockey pump electric motor 7.5 HP capacity 3 phase for repairs, strip opening for repairs, rewinding and varnishing the stator winding with suitable grade, varnish and drying etc, oiling, greasing the bearings etc and replacement of unserviceable bearings, re-metaling the bearing cover plate and reassembling and fixing the motor in position and testing complete all as specified and directed.
Note :- Transportation to work shop and refixing the same at its position is deemned to be included in the quoted rate.
1
-
-
All as per item No 28 here-in-before but 60 HP capacity complete all as specified and as directed.
1
-
-
Supply and fixing power contactor 3 Pole, 415V, AC3 rating 75 Amps complete all as specified and directed.
2
-
-
Supply and fixing power contactor 3 Pole, 415V, AC3 rating 100 Amps complete all as specified and directed.
2
-
-
Supply and replace relay suitable for Jockey pump 15 HP capacity complete all as specified and as directed.
2
-
-
Material and labour for flushing out the complete pipe system from Co2 bank to gas nozzles with the adequate pressure of Nitrogen gas including taking out, opening and cleaning of nozzle complete all as specified and directed.
4
-
-
M&L including filling of CO2 gas 22.5 Kg in existing empty high pressure seamless cylinders having 22.5 Kgs capacity after carrying to authorized filling station of CO2 gas and fixing back to the plant complete all as specified and directed.
Note: Cylinder shall be affixed with lamintated sticker of size not less than 100mmX75mm compresing details of cylinder i.e. Tare wt of cylinder, Nett wt. or filled gas & date.
110
-
-
Supply CO2 gas cylinder seam less of capacity 22.5 kg or nearest higher size conferming to relevent of IS with control , valves etc duly filled with CO2 gas all as specified and directed.
5
-
-
M&L including filling of Nitrogen (N2) gas 2 Kg in high pressure seamless cylinders having 2 Kgs capacity after carrying to authorized filling station of N2 gas and fixing back to the plant complete all as specified and directed.
20
-
-
Supply N2 gas cylinder seam less of capacity 2 kg or nearest higher size conferming to relevent of IS with control, valves etc with N2 gas all as specified and directed.
3
-
-
M & L for preparation of old painted steel surfaces of any description over and applying two coats of synthetic enamel paint of approved colour complete all as specified and directed.for Fire Fighting stand post of 1.5m height along with fire hydrant valve complete all as specified and as directed.
20
-
-
All as per item No 38 here-in-before but painting to hose cabinet complete all as specified and as directed.
8
-
-
M & L for preparation of the old existing steel surfaces of CO2 Gas cylinder and applying two coats of synthetic enamel paint of approved colour complete all as specified and directed.
20
-
-
Supply and fix 80mm bore MS pipe class 'C' heavy duty with Seemless welding/flanged joints including required MS fittings & testing complete all as specified and directed. Note: 1. Necessary excavation and return refilling will be measured and paid separately. 2. The cost of two coats of bituminous paint is deemed to be included in the quoted rate.
50
-
-
All as per item No 41 here-in-before but 150 mm dia complete all as specified and as directed.
100
-
-
Supply only brass discharge nozzles cone type for CO2 cylinders of approved make complete all as specified nd directed.
10
-
-
Supply only high pressure flexible hose pipe10 Kg /cm2 with flexible hose pipe flexible connector for pneumatic line & cylinder of approved make complete all as specified and directed .
20
-
-
Supply only high pressure flexible hose pipe 10 kg/cm2 with flexible hose pipe flexible connector for cylinder to cylinder of approved make complete all as specified and directed.
20
-
-
Supply only high pressure brass ISI mark non return valve 20mm bore for manifold and discharge hose connection of approved make complete all as specified and directed.
10
-
-
Supply only solenoid valve 60Kg/cm2 pressure two way 15 mm dia (ISI mark) including all fitting complete all as specified and directed.
2
-
-
Supply only high pressure brass safety valve 25mm bore (ISI mark) with outlet pipe of approved make complete all as specified and directed.
2
-
-
Supply, fixing, testing and commissioning of Fire alarm system wiring using three single core PVC insulated, sheathed stranded copper conductor cable of size 1.5 Sqmm 1100 Volts drawn in and including MS conduit (Medium grade ISI marked) of dia not less than 20mm with standard accessories complete all as specified and directed .
250
-
-
All as per item No 49 here-in-before but wiring in the existing conduit complete all as specified and as directed
100
-
-
Disconnecting of unserviceable battery of any description and supply and fixing maintenance free battery of 12 volts 7 AH capacity and connecting and testing at site complete all as specified and directed.
25
-
-
Supply & fixing, in repair including testing and commissioning of Fire alrm Control panel complying with BSEN54 addressable two loop panel as compatible with the existing detectors of capacity from 99 detector and 99 modules upto 200 detector and modules complete with battery 12 volts 7 AH capacity (02 Nos ) all as specified and directed Make :- GST/Rawel/Agni devices or as per the site.
4
-
-
All as per item No 52 here-in-before but Non- addessable type panel complete all as directed
1
-
-
Supply & fixing, in repair including testing and commissioning of addressable / conventional manual call point (MCP) surface mounting with glass cover complete all as specified and directed.
8
-
-
Supply & fixing, in repair including testing and commissioning of Auto Dialer system complete all as specified and directed.
1
-
-
Programming/re-loading of software for existing unserviceable fire alarm control panel to make it functional with the help of software to suit existing panel/model including testing of all connected circuits/detectors complete all as specified and directed.
2
-
-
M&L for repairs to PCB of any make or any type of defective Fire alarm control panel including testing of the same complete all as directed
5
-
-
Supply only Pneumatic actuator suitable for cylinder valve (ISI mark) operating at 15 to 30 Kg/cm2 complete all as specified and directed.
8
-
-
Supply only Butter Fly Valve 150 mm CI Lever operated pressure /Class /Rating PN-1.6, Water type Nitrile Rubber Lining SG Iron (Make: Sant ,Castrol, Kartar) ISI Marked
3
-
-
All as per item no 59 here-in-before but butter fly valve 100 mm dia all as directed by Eng-in-Charge.
4
-
-
All as per item no 59 here-in-before but butter fly valve 80 mm dia all as directed by Eng-in-Charge.
4
-
-
Supply only Carbon -Di-Oxide (CO2 ) Portable Fire Extinguisher capacity 4.5 Kg MS Seamless body ISI With Gun mattle Valve . High Pressure Horn type Hose pipe ,with Syphan ,95% Min Efficitive Discharge ,Operation valve Upright Wheel / Squeeze Grip type Including fixing of wall complete with suitable clamp with nuts, bolts and washers .(Make : Like Gurd , Safex )
10
-
-
Supply only ABC type Power Filled Fire Extinguisher capacity 4 kg IS 15683 ,85% Mon effective Discharge , 13 Sec Discharge Time ,35 kgf /cm2 Hydraulic tested Pressure .Including fixing of wall complete with suitable clamp with nuts, bolts and washers . (Make : Like Gurd , Safex )
15
-
-
Disconnecting of unserviceable battery of any description and supply and fixing maintenance free battery of 12 volts 80 AH capacity and connecting and testing at site complete all as specified and directed.
2
-
-
All as per item no 64 here-in-before but 12V 150AH
1
-
-
Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
200
-
-
Removal of surplus spoil to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
40
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
160
-
-
M&L for Annual Maintenance of Servo Voltage Stabilizer of following capacity complete with Check transformer oil level & ensure its up to the mark, Tightened input out put cable , Check and clear cable termination box for any foreign substance ( Ex Bird nest , lizards etc),Ensure stabilizer body & neutral connections are properly earthed,Check by increasing & decreasing voltage through control panel and replacing the defective spares and topping up of oil if required including half yearly preventive maintenance Checks and unlimited breakdown visits by qualified technician complete all as specified and directed by Engr-in-charge.
-
-
-
(a) Servo Controlled Voltge Stabilizer 200 KVA Capacity - 03 Nos
1
-
-
(b) Servo Controlled Voltge Stabilizer 125/130 KVA Capacity - 01 Nos
1
-
-
(d) Servo Controlled Voltge Stabilizer 50 KVA Capacity - 02 Nos
1
-
-
(e) Servo Controlled Voltge Stabilizer 10/20 KVA Capacity - 04 Nos
1
-
-
(i) Servo Controlled Voltge Stabilizer 100 KVA Capacity - 02 Nos
1
-
-
(j) Servo Controlled Voltge Stabilizer 400 KVA Capacity - 01 Nos
1
-
-
Annual maintenance for a period of eleven months for 3 phase UPS of following capacities with 20min battery backup with Input:- 415 Volts +/- 1% 3 phase AC PF-0.85 Out Put:- Voltage 415V +/-1% 3 Phase AC Frequency 50Hz :-
The scope of work shall comprise the following:
a) Breakdown maintenance (b) Preventive and corrective maintenance.quarterly for a period of 11 months (c) Maintenance UPS and battery including repair/replacement of connected accessories all as specified and as directed by Engr-in-Charge through Authorised Manufacturer's service Centre Engineers or through OEM certified agencies as directed.Spare parts to be replaced as per site requirement is the responsibility of the OEM.
-
-
-
Note :-
(i) The Contractor agrees to provide the following Non comprehensive services arising out of wear and tear of the normal usage of UPS
(ii) Preventive and Corrective Maintenance : The authorised service representative of OEM or OEM certified agencies shall visit the site quarterly for carrying out preventive and corrective maintenance on all the units installed at site. This includes maintenance of all mechanical, electrical and electronic parts / sub-assemblies. The preventive maintenance report will be as per the manufacturer's instruction and as specified in Particular Specification. (iii) Breakdown Maintenance : The authorised service representative of OEM or OEM certified agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE(AF) TA Gwalior officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and inform office about the status of site. No payment shall be made on this account of any breakdown service during comprehensive maintenence period.
-
-
-
a) UPS 3 Phase 30 KVA capacity - 01 Nos with 32 batteries of 75 AH installed at ATC
2
-
-
b) UPS 3 Phase 15 KVA capacity - 01 Nos with 32 batteries of 75 AH installed at WSMT
2
-
-
c) UPS 3 Phase 05 KVA capacity - 02 Nos with 32 batteries of 75 AH installed at ATC & Old ATC
2
-
-
Supply only sealed maintenance free batteries 35 AH suitable for 02 Nos 05 KVA UPS system complete for its satisfactory operation
Note: Unserviceable retrieved batteries shall be returned to E/M stores.
35
-
-
All as per item no 72 here-in-before but 180 AH capacity
2
-
-
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized iron strip of 25 x 4mm as earth continuity conductor by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electric plate No 5, of SSR Part - I, 2009 & all as specified, testing on completion including provision of earth lead protected by 40 mm dia GI pipe medium grade & watering pipe 20 mm medium grade including all excavation and earth work in any type of soil, PCC pit (1:3:6) type C1 with RCC cover, charcoal, salt, funnel etc complete including making good disturbed surfaces of wall, floor.
Note : (i) The rate is inclusive of cost of earthing lead of 25 x 4mm and GI protection pipe 40mm size upto 7.5 m length from the top edge of the GI plate electrode.. (ii) Irrespective of what is shown on plate No 5 of SSR Part-I /2009, the earthing pit shall be precasted PCC (1:3:6) type C1 and the cover of earthing pit shall be of precast RCC (1 :2 : 4) type B1 with suitable handle fushed with surface all as specified. (iiii) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet of size 300mmX 300mmX3mm size, fixed with necessary nuts and bolts on angle iron of size 40X40x5mm & length 60cm and grouted in the ground with PCC (1:3:6) using 20mm grade stone masonery of size 200mmX200mmX250mm including necessary earth work.for marking the result and its purpose of use.
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%