Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date25 Oct 2024
Closing Date29 Nov 2024
Tender Amount₹ 9,11,78,000 
Notes
Download

Costs

Summary

752930a Augmentation Of Electric Supply Under Ge West Jabalpur

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Item No 3: Dismantling of cross arm(made of MS channels / angles etc.) or clamps etc.complete and stacking aside for re-use / replacement all as directed by Engr-in-Charge

14

-

-

... More
Item No 4: Dismantling of stay assembly embedded in concrete and removing materials from site of work complete all as directed by Engineer-in-Charge.

30

-

-

... More
Item No 5: Dismantling of old unserviceable service connection cable with GI wire and reel insulator complete all as directed by Engr-in-Charge.

1500

-

-

... More
Item No 6: Dismantling of existing GI earth wire any size complete all as specified and directed

9

-

-

... More
Item No 7: Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X6 MM mm strip by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.

110

-

-

... More
Item No 8: Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.

20

-

-

... More
Item No 9:Taking down of old unserviceable cable of any type upto and including 50 sqmm complete all as specified and directed

1000

-

-

... More
Item No 10:Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core

400

-

-

... More
Item No 11:do-- but size 16 sq mm 4 core

9408

-

-

... More
Item No 12: do-- but size 25 sq mm 4 core

6026

-

-

... More
Item No 13:do-- but size 35 sq mm 3.5 core

1055

-

-

... More
Item No 14:do-- but size 50 sq mm 3.5 core

465

-

-

... More
Item No 15:do-- but size 70 sq mm 3.5 core

340

-

-

... More
Item No 16: do-- but size 95 sq mm 3½ core

800

-

-

... More
Item No 17: do-- but size 120 sq mm 3½ core

520

-

-

... More
Item No 18: do-- but size 150 sq mm 3½ core

170

-

-

... More
Item No 19: do-- but size 185 sq mm 3½ core

320

-

-

... More
Item No 20: do-- but size 240 sq mm 3½ core

80

-

-

... More
Item No 21: do-- but size 300 sq mm 3½ core

200

-

-

... More
Item No 22: do-- but size 400 sq mm 3½ core

480

-

-

... More
Item No 23:Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1200 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 800 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422257

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420249

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420248

-

-

-

... More
(c) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420053

-

-

-

... More
(d) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(e) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(f) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(g) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(h) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(j) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(k) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(l) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 24 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 300 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420053

-

-

-

... More
(b) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(c) Digital Ammeter 96mm x 96mm suitable to read 0 to 200 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(d) Current transformer (CT) of rating 200/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(e) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(f) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(g) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 25 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

2

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 250 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 26 :Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1000 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 630Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422009

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 315 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422006

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
© 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420053

-

-

-

... More
(d) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(e) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(f) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(g) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(h) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(j) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(k) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(l) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates. (Old Mandla)

-

-

-

... More
Item No 27 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 300 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
OUTGOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 100Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420055

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420053

-

-

-

... More
(c) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(d) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Current transformer (CT) of rating 300/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(f) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(g) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(h) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 28 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 300 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
OUTGOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420053

-

-

-

... More
(b) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(c) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(d) Current transformer (CT) of rating 300/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(e) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(f) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(g) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 29 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 500 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 315 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422006

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 160 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420057

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63A mps, 415 Volts, 50 Hz. - 03No Legrand Cat part No.420053

-

-

-

... More
(c) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(d) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(e) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(g) Current transformer (CT) of rating 320/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 30 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1200 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 800 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422257

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420249

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
(c) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420053

-

-

-

... More
(d) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(e) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(f) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(g) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(h) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(j) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(k) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(l) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 31 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 250 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 32 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 300 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420053

-

-

-

... More
(b) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(c) Digital Ammeter 96mm x 96mm suitable to read 0 to 200 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(d) Current transformer (CT) of rating 200/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(e) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(f) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(g) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 33 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 05 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 250 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 34 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1000 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 630Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422009

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420248

-

-

-

... More
© 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420053

-

-

-

... More
(d) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(e) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(f) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(g) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(h) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(j) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(k) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(l) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates. (Old Mandla)

-

-

-

... More
Item No 35 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 250 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 36 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 300 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

2

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 250 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(k) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 37 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 300 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 05 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 250 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 38 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1200 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 800 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422257

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422007

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01No Legrand Cat part No.420249

-

-

-

... More
(c) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 160Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420057

-

-

-

... More
(d) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420053

-

-

-

... More
(e) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(f) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(g) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(h) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(j) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(k) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(l) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(m) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 39 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 600 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422007

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 160Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420057

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 400 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 40 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 250 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 41 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 300 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 160Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420057

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 200 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 200/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 42 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1200 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 800 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422257

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.422021

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420053

-

-

-

... More
(c) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(d) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(e) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(f) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(g) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(h) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(j) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(k) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 43 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 600 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422021

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 06 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 400 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 44 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 600 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.422021

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 400 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 45 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1000 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 630 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422009

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 315 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422006

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
(c) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420053

-

-

-

... More
(d) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(e) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(c) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(d) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(e) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Digital Ammeter 96mm x 96mm suitable to read 0 to 800 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(g) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 46 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 315 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.422006

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 05 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 400 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 47 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 05 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 400 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 48 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 600 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422007

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420248

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420053

-

-

-

... More
(c) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(d) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(e) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(f) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(g) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(h) Digital Ammeter 96mm x 96mm suitable to read 0 to 600 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(j) Current transformer (CT) of rating 600/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(k) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 49 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 600 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422007

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420249

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420053

-

-

-

... More
(c) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(d) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(e) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(f) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(g) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(h) Digital Ammeter 96mm x 96mm suitable to read 0 to 500 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(j) Current transformer (CT) of rating 500/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(k) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 50 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

2

-

-

... More
INCOMING : pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420249

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420053

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 400 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 51 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1500 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 1000 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422258

-

-

-

... More
OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 630 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422009

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422007

-

-

-

... More
(c) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420053

-

-

-

... More
(a) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos

-

-

-

... More
(b) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos

-

-

-

... More
(c) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(d) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(e) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Digital Ammeter 96mm x 96mm suitable to read 0 to 1000 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(g) Current transformer (CT) of rating 1000/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 52 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 100 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420053

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 16 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 40Amps, 415 Volts, 50 Hz. - 05 No Legrand Cat part No.420012

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 100 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 53 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 100 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420053

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 16 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 40Amps, 415 Volts, 50 Hz. - 05 No Legrand Cat part No.420012

-

-

-

... More
(b) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(c) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 100 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 54 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1000 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole ACB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 630 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422009

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 03 No Legrand Cat part No.420053

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 16 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 40Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420012

-

-

-

... More
(c) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(d) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(e) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Digital Ammeter 96mm x 96mm suitable to read 0 to 100 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(g) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 55 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 600 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 400 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422007

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 100Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420055

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420053

-

-

-

... More
(c) 4 pole MCCB having breaking capacity 16 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 40Amps, 415 Volts, 50 Hz. - 06 No Legrand Cat part No.420012

-

-

-

... More
(d) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(e) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(f) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(g) Digital Ammeter 96mm x 96mm suitable to read 0 to 400 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(h) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(j) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 56 : Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 150 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring .

1

-

-

... More
INCOMING : 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 100 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420055

-

-

-

... More
OUT GOING :(a) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.420053

-

-

-

... More
(b) 4 pole MCCB having breaking capacity 16 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 40Amps, 415 Volts, 50 Hz. - 04 No Legrand Cat part No.420012

-

-

-

... More
(c) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No.

-

-

-

... More
(d) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.

-

-

-

... More
(e) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos

-

-

-

... More
(f) Digital Ammeter 96mm x 96mm suitable to read 0 to 100 Amps, accuracy class 1% - 01 Nos

-

-

-

... More
(g) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos

-

-

-

... More
(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos

-

-

-

... More
(i) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI

-

-

-

... More
Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.

-

-

-

... More
Item No 57 : Dismantling of old unservicable bus bar chamber and Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947.

15

-

-

... More
The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation.

-

-

-

... More
Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).

-

-

-

... More
Item No 58 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm Model KF - 9250, 5 way having terminals for termination of cable with necessary nuts and bolts , including -02 Nos polycarbonate cable gland Model-AKM-25 , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed.

120

-

-

... More
Item No 59 : Supply & fixing and connecting PVC insulated stranded aluminium conductor cable 4 Sqmm flat 3 core 1100 volts grade complete all as specified and directed.

960

-

-

... More
Item No 60 : Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed.

150

-

-

... More
Item No 61 : Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling complete all as specified and directed by Engr in charge.

10

-

-

... More
Item No 62 : Material and labour for providing cement concrete 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in coping complete all as specified and directed by Engr in charge.

10

-

-

... More
Item No 63 : Supply and fixing oil cooled high tension current transformer of dual ratio of 100-50/5 Amps, 15 VA burden out put, accuracy class-0.5 conforming to IS 2705/IEC 60044-1 suitable for rated voltage system of 33KV for metering/ protection of breakers after taking out the old unserviceable CT and testing on completion complete all as directed amd specifed by Engineer in chrge

2

-

-

... More
Item No 64 : Supply and installation of 33 KV 3 phase 50c/s out door dry type 33 KV of ration 33KV / under root 3/110/under root 3V, 3 phase, draw out type, Core I, Cl1.0 with 100 VA burden for metering & protectionPT ratio 33 KV/110 volts class 0.5 50 VA burden isolation lavel 33 KV a;; as required and directed by Engineer in charge.

2

-

-

... More
Item No 65 : Supply, installation, commissioning and testing of 33 kV nominal voltage SF6 Ring Main Unit (2 I/C +4 O/G + 1 PT Panel), compact, out door type (IP54), 630 Amps, breaking capacity 25 kA for 1 sec having 6 vacuum circuit breaker (VCB) insulated in SF6 and one Bus PT panel extensible to right side RMU/ Outdoor, motorised having metering panel and copper bus bar of suitable ampere ratings complete with and including the followings:- Notes: (i) Brief description of this item is "33 kV, SF6 Ring Main Unit complete with 6 Vacuum Circuit Breaker + 1 Bus PT Panel (Right side extensible / OUTDOOR) - MOTORIZED". (ii) As per manufacturers design, cost of making of platform shall be deemed to be included in unit quoted rates. (iii) All necessary arrangements for performance testing of RMU shall be made by contractor without any extra cost to government.

1

-

-

... More
(A) HT COMPARTMENT: VACUUM CIRCUIT BREAKER - Each module of Vaccuum Circuit Breaker enclosed in SF6 -06 Nos(2 I/C +4 O/G + 1 PT Panel). (a) The function unit shall consist of a three position switch. The three position switch shall fulfil the operation of the disconnector function and the earthing function. The circuit breaker unit T2 shall be equipped with an over current time release for the protection of distribution transformer. (b) Vacuum circuit breaker shall be of 33 kV, 630 Amps, 25 kA for one sec enclosed in SF6. (c) Spring assisted closing with stored energy tripping mechanism for T2-motorised operation with integrated earthing switch. (d ) Having auxiliary contacts on load break switch 1 NO+2 NC & auxiliary contacts on earth switch 1 NO+1 NC - 01 No. (e) Self powered electronic numerical protection relay providing 3 over current & 1 earth fault protection for Each Breaker - 06 No. (f) Tape wounded protection CT shall be 100/5, 10P5, 2.5VA - 03 Nos. (g) Tape wounded metering CT shall be 100/5, Class-1.0, 2.5 VA - 03 Nos. (h) Shunt trip Coil - 24 V DC - 01 No. (j) Capacitive voltage indication fixed type (LED display) - 01 No. (k) On/ Off/ TRIP mechanical indication on the front mimic of the panel-01 Set. (l) Cable box for termination of XLPE cable of size 3 core 95 sqmm to 120 sqmm aluminium conductor- 01 No. (m) Cable cover standard - 01 No. (n) Emergency trip push button- 01 No. (o) Set of 33 kV cable termination boots - 1 Set (p) Ammeter of suitable capacity/ class -01 No. (q) Rated frequency - 50/60 Hz

-

-

-

... More
(r ) Rated Power frequency withstand voltage directly earthed -28 kV (s) Level of insulation for the SF6, rated lightening impulse withstand voltage - 75 kV (t) Level of insulation for the SF6, rated power frequency withstand voltage - 28 kV (u) Level of insulation of the sectionalized distance for the cable test energized busbar, maximum AC feeder test voltage - 18 kV (v) Rated current busbar C-R-RE functions - 630 Amps (w) Rated current busbar SB functions - 630 Amps (x) Rated current outgoing feeder- 630 Amps (y) Rated short time current, main electrical circuit for 1 Sec - 25kA (z) Rated short time current, earthing circuit for 1 Sec - 25kA (aa) Rated network load and closed loop breaking current - 630 Amps (ab) Rated no load cable breaking current -160 Amps (ac) Rated breaking current under earth fault conditions - 630 Amps (ad) Rated no-load cable breaking current under earth fault conditions - 277 Amps

-

-

-

... More
(B) BUS METERING PANEL (a) 03 Single phase PT 33 kV/ RT3/ 110V/RT3, 100 VA, class -1.0 (b) 01 Space heater (c ) RYB indication - one set (d) 01 No. Voltmeter (e) Microprocessor based three phase electronic tamper compatibel for scada arangemet proof HT energy meter with optical communication port, accuracy class 0.5 rating 3 X 110 V, 1/5 A conforming to IS : 13779. (f) 24 V DC battery and battery charger - 01 Set

-

-

-

... More
(C) Additional equipment to be mounted on each RMUs (a) Manometer with IEC standards- 01 No. (b) Operating Handle - 01 No. (c) Cable clamping provision (standard) - 01 Set (d) Cable testing Plug and Stud - 01 set (e) O&M Manual (f) I&C Manual

-

-

-

... More
Item No 66 : Supply, Installation, testing and commissioning HT 11 KV, 3 Phase, 50 Hz, 3 wire, totally enclosed, metal clad, prewired, extensible type, indoor type, floor mounted, Horizontal draw out, horizontal isolation type vaccum circuit breaker (VCB) 630 Amp rating, consisting of INCOMER VCB-02 No, Outgoing VCB-04 No and suitable size bus coupler VCB with copper bus bar of appropriate capacity duly insulated, motor operated, spring charged having rupturing capacity 350 MVA , comprising of the followings including provision of suitable foundation and duct under the VCBs for necessary entry for cables with and including the followings:- (A) Incoming VCB, 630 Amps, 350 MVA - 02 No with and including the followings : (a)   Housing for circuit breaker carriage - 1 No (b) Vacuum interupter suitable for 400 Amps-set of 03 (c)   Mechanical inter lock and automatic safety shutter gear including padlocking arrangement - 1 No (d) Closing & tripping coil suitable for 24 V DC - 01 Set (e) 4 NO + 4 NC Auxiliary switch - 01 Set (f) Mechanical ON/OFF indicator - 01 Set (g) Mechanical spring charge/discharge indicator-01 Set (h) Breaker Position indicator - 01 Set (j) Mechanical operating counter-01 Set (k) Automatic safety shutters - 01 Set (l) Secondry Plug in contacts-01 Set (m) Anti Pumping relay - 01 Set (n) 11 KV Epoxy Resin Cast current transformer of ratio 200-100/50-5+5A, Core I, Class 1.0 with 15 VA burden for metering, core II CL-1.0, 5 P 10 with 15 VA burden for protection, - 03 Nos

2

-

-

... More
(o) 11 KV epoxy resin cast potential transformer of ratio 11/ under root 3/110/under root 3V, 3 phase, draw out type, Core I, Cl1.0 with 100 VA burden for metering & protection-01 No (p) meter misc type 96sqmm ammeter with selector switch - 01 No (q) Meter Misc type 96sqmm voltmeter with selector switch - 01 No (r ) Relay non drawout case type, micro processed based non-direction IDMT - 01 No (s) Master trip relay model No AVAJH-13-01 No (t) Auxilary relay - Model No AVA-23-01 No (u) Trip circuit suspervision relay model No JRV-911-01 No (v) Battery power pack with battery & in built charger for 24V circuit-01 Set (w) KWH meter suitable to record unit consumed-01 No (x) R,Y,B indication lamp- 01 Set (xi) Breaker ON/OFF indicating lamps-01 No (xii) Spring charging indication lamp-01 No (xiii) Auto trip indication lamp-01 No (xiv) Trip circuit healthy indication-01 No (xv) Trip/Neutral/Close switch-01 No (xvi) Trip circuit healthy push button-01 No (xvii) MCB for spring charge motor-01 No (xviii) MCB for AC/DC supply-01 Set (xix) Panel space heater with thermostat-01 No (xx) Panel illumination with switch-01 No (xxi) 5 Amps 3 pin socket with switch-01 No (xxii) Copper Bus bar 630 Amps rating with sleeves R, Y. B-01 Set (xxiii) Control fuses, ferules & wiring complete - 01 Set

-

-

-

... More
(xxiv) MS cubical with powder coating - 01 Set (r) Relay non drawout case type, micro processed based non-direction IDMT - 01 No (Notes :1.Before placement of order, contractor will submit Genral Arrangement(GA) drawing & other drawings in detail to GE for approval . On approval of drawings, contractor shall place the order. 2. Pre-dispatch inspection shall be carried out at Manufacturer Premises by Representative of Accepting Officer. cost thereof , if any, is deemed to be included in the unit rate quoted by the contractor ) Add : Description of bus coupler VCB : Vacuum Circuit Breaker 11 KV, 800A Current rating frequency 50 Hz Short Circuit Breaking Capacity 21 KA. The bus coupler shall be housed in a robust, dustproof, and waterproof metal enclosure with IP degree of protection having Copper busbars with appropriate insulation with reliable spring-charged or motor-charged operating mechanism. VCB should be Capable for remote operation and monitoring through SCADA. All metering panels and tripping mechanisms shall comply with incoming and outgoing VCBs. Note :- Above quotaed rate shall be include shifting /disconnection/reconnection of existing VCB as per site requirement

-

-

-

... More
Item No 67 : Supply, installation, commissioning and testing of 12 kV nominal voltage SF6 Ring Main Unit, compact, out door type, 630 Amps, breaking capacity 21 kA for 1 sec having 4 vacuum circuit breaker (VCB) insulated in SF6, two load break switch (LBS) insulated in SF6 and one Bus PT panel extensible to right side RMU/ Outdoor, motorised having metering panel and copper bus bar of suitable ampere ratings complete with and including the followings:- Notes: (i) Brief description of this item is "12 kV, SF6 Ring Main Unit complete with 4 Vacuum Circuit Breaker + 2 LBS+ 1 Bus PT Panel (Right side extensible / OUTDOOR). FBX-RE/12-21/ M+CT2T2 /OUTDOOR - MOTORIZED". (ii) As per manufacturers design, cost of making of platform shall be deemed to be included in unit quoted rates. (iii) All necessary arrangements for performance testing of RMU shall be made by contractor without any extra cost to government.

1

-

-

... More
(A) HT COMPARTMENT: VACUUM CIRCUIT BREAKER - Each module (Vaccuum Circuit Breaker) enclosed in SF6 -04 Nos. (a) The function unit shall consist of a three position switch. The three position switch shall fulfil the operation of the disconnector function and the earthing function. The circuit breaker unit T2 shall be equipped with an over current time release for the protection of distribution transformer. (b) Vacuum circuit breaker shall be of 12kV, 630 Amps, 21 kA for one sec enclosed in SF6. (c) Spring assisted closing with stored energy tripping mechanism for T2-motorised operation with integrated earthing switch. (d ) Having auxiliary contacts on load break switch 1 NO+2 NC & auxiliary contacts on earth switch 1 NO+1 NC - 01 No. (e) Self powered electronic numerical protection relay providing 3 over current & 1 earth fault protection - 01 No. (f) Tape wounded protection CT shall be 100/5, 10P5, 2.5VA - 03 Nos. (g) Tape wounded metering CT shall be 100/5, Class-1.0, 2.5 VA - 03 Nos. (h) Shunt trip Coil - 24 V DC - 01 No. (j) Capacitive voltage indication fixed type (LED display) - 01 No. (k) On/ Off/ TRIP mechanical indication on the front mimic of the panel-01 Set. (l) Cable box for termination of XLPE cable of size 3 core 95 sqmm to 120 sqmm aluminium conductor- 01 No. (m) Cable cover standard - 01 No. (n) Emergency trip push button- 01 No. (o) Set of 12 kV cable termination boots - 1 Set (p) Ammeter of suitable capacity/ class -01 No. (q) Rated frequency - 50/60 Hz

-

-

-

... More
(r ) Rated Power frequency withstand voltage directly earthed -28 kV (s) Level of insulation for the SF6, rated lightening impulse withstand voltage - 75 kV (t) Level of insulation for the SF6, rated power frequency withstand voltage - 28 kV (u) Level of insulation of the sectionalized distance for the cable test energized busbar, maximum AC feeder test voltage - 18 kV (v) Rated current busbar C-R-RE functions - 630 Amps (w) Rated current busbar SB functions - 630 Amps (x) Rated current outgoing feeder- 630 Amps (y) Rated short time current, main electrical circuit for 1 Sec - 25kA (z) Rated short time current, earthing circuit for 1 Sec - 25kA (aa) Rated network load and closed loop breaking current - 630 Amps (ab) Rated no load cable breaking current -160 Amps (ac) Rated breaking current under earth fault conditions - 630 Amps (ad) Rated no-load cable breaking current under earth fault conditions - 277 Amps (B) HT COMPARTMENT: LOAD BREAK SWITCH- C, 12 kV, 21 kA, 630 Amps - EACH MODULE (LBS) enclosed in SF6 -02 Nos. (a) The switching unit shall be so designed as a three position switch. The three position switch combines the functions of switch disconnector and earthing switch. The switch disconnector as well as the earthing switch shall be equipped with a separate drive unit. (b) Cable switch 11 kV, 630 A, 21 kA for 1 sec - 01 No. (c ) Spring assisted mechanisim for C-manual operation with integrated earthing switch - 01 No. (d) Cable bushing 630 Amps, Standard C-bushings - 01 No.

-

-

-

... More
(e) Aux switch for load break (ON & OFF) - 01 No. (f) Cable Cover standard - 01 No. (g) Capacitive voltage indication fixed type (LED display) - 01 No. (h) On/ Off/ EARTH indication on the front mimic of the panel - 01 Set. (j) Cable box for termination of XLPE cable of size 3 core 95 sqmm to 185 sqmm aluminium conductor- 01 No. (k) Operation counter - 01 No. (l) Cable boot suitable for 11 kV - 01 Set, cable entry shall be provided from front bottom (m) Rated frequency - 50/60 Hz (n ) Rated power frequency withstand voltage directly earthed -28 kV (o) Level of insulation for the SF6, rated lightening impulse withstand voltage - 75 kV (p) Level of insulation for the SF6, rated power frequency withstand voltage - 28 kV (q) Level of insulation of the sectionalized distance for the cable test energized busbar, maximum AC feeder test voltage - 18 kV (r) Rated current busbar C-R-RE functions - 630 Amps (s) Rated current busbar SB functions - 630 Amps (t) Rated current outgoing feeder- 630 Amps (u) Rated short time current, main electrical circuit for 1 sec - 25kA (v) Rated short time current, earthing circuit for 1 sec - 25kA (w) Rated network load and closed loop breaking current - 630 Amps (x) Rated no load cable breaking current - 160 Amps (y) Rated breaking current current under earth fault conditions - 630 Amps (z) Rated no-load cable breaking current under earth fault conditions - 277 Amps

-

-

-

... More
(C) BUS METERING PANEL (a) 03 Single phase PT 11 kV/ RT3/ 110V/RT3, 100 VA, class -1.0 (b) 01 Space heater (c ) RYB indication - one set (d) 01 No. Voltmeter (e) Microprocessor based three phase electronic tamper compatibel for scada arangemet proof HT energy meter with optical communication port, accuracy class 0.5 rating 3 X 110 V, 1/5 A conforming to IS : 13779. (f) 24 V DC battery and battery charger - 01 Set

-

-

-

... More
(D) Additional equipment to be mounted on each RMUs (a) Manometer - 01 No. (b) Operating Handle - 01 No. (c) Cable clamping provision (standard) - 01 Set (d) Cable testing Plug and Stud - 01 set (e) O&M Manual (f) I&C Manual

-

-

-

... More
Note for Item No 65,66 & 67 :- (1) Contractor will have to submit and get approval on the GA Drawings & other Technical Drawings with complete specifications and Design Details of above 33/11 KV HT switchgears and RMUs by GE.On approval of drawing, contractor shall place the order. (2) Various IEC & IS standard shall be meet while designing of HT Switch Gears.Pre-dispatch inspection shall be carried out at Manufacturer Premises by Representative of Accepting Officer. cost thereof , if any, is deemed to be included in the unit rate quoted by the contractor.All metering panels and tripping mechanisms shall comply with incoming and outgoing VCB/RMU. (3) If any part is missing in the above specifications or if any discrepencies are there in any specifications or ratings mentioned in the above Items as per OEM recommendations,then Contractor will fullfill all the requirements complete to the satisfaction to the Site Executives & GE without any extra cost.

-

-

-

... More
Item No 68 : Supply and fix switch air break gang operated HT 33 KV Volt grade triple pole with 12 Polymer based insulators, 400 amps rating mounted on Polymer based insulator and fitted on steel frame horizontally operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50 mm x 6 mm including MS channel of suitable size and length for fixing GOD including bolts, nuts, and washers complete all as specified and directed. (Note: - MS work shall be measured & paid for separately under respective items.)

3

-

-

... More
Item No 69 : Supply and Installation of 11 KV, 630 Amp Load break switch with 200 Amp DO set and earth switch

4

-

-

... More
Item No 70 : Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm.

11110

-

-

... More
Item No 71 : Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.

8970

-

-

... More
Item No 72 : Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 Sqmm to 95 sqmm,Outdoor type

22

-

-

... More
Item No 73 : Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 Sqmm to 120 sqmm, Indoor/Outdoor type

20

-

-

... More
Item No 74 : Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm

8

-

-

... More
Item No 75 : Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm

24

-

-

... More
Item No 76 : Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm

14

-

-

... More
Item No 77 : Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm

10

-

-

... More
Item No 78 : M&L for cable jointing kit for 33 KV (Earthed) grade cable for outdoor cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm and testing on completion complete all as directed.

12

-

-

... More
Item No 79 : S & F MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed in and including providing of one coat of red oxide and one coat of aluminium paint complete all as specified and directed by Engr in charge.

15

-

-

... More
Item No 80 : M&L for new lightning arrestor expulsion type complete with all fittings, transmision/ distribution class 65 KA, conforming to IS-3070 (Part-III) 1993 suitable for 11 KV system and mounting on poles including all necessary bolts, nuts and washers and making electric connection after taking out the old unserviceable lightning arrestor and testing on completion complete all as specified and directed.

2

-

-

... More
Item No 81 : M&L for new lightning arrestor expulsion type complete with all fittings, transmision/ distribution class 65 KA, conforming to IS-3070 (Part-III) 1993 suitable for 11 KV system and mounting on poles including all necessary bolts, nuts and washers and making electric connection after taking out the old unserviceable lightning arrestor and testing on completion complete all as specified and directed.

5

-

-

... More
Item No 82 : Taking out the HT pole PCC/Steel tubular complete with all as required and directed at site

20

-

-

... More
Item No 83 : Taking down the cross arm complete with stringing all as required and directed at site

5

-

-

... More
Item No 84 : Taking out the cable and refixing/rerouting HT/LT cable of 120/95 Sqmm from trenches and refixing all as required and directed

1000

-

-

... More
Item No 85 : Taking down AB swithces complete

17

-

-

... More
Item No 86 : S & F of Retrofit emission control system for DG Sets of capacity 30 KVA complete including dual fuel conversion kit in existing DG Set and exhaust piping with insulation and aluminium kit cladding on MS support for extension to existing exhaust piping with bellows/ connectors all as required, specified & directed

5

-

-

... More
Item No 87 : S & F of Retrofit emission control system for DG Sets of capacity 40 KVA complete including dual fuel conversion kit in existing DG Set and exhaust piping with insulation and aluminium kit cladding on MS support for extension to existing exhaust piping with bellows/ connectors all as required, specified & directed.

3

-

-

... More
Item No 88 : S & F of Retrofit emission control system for DG Sets of capacity 125 KVA complete including dual fuel conversion kit in existing DG Set and exhaust piping with insulation and aluminium kit cladding on MS support for extension to existing exhaust piping with bellows/ connectors all as required, specified & directed.

2

-

-

... More
Item No 89 : S & F of Retrofit emission control system for DG Sets of capacity 100 KVA complete including dual fuel conversion kit in existing DG Set and exhaust piping with insulation and aluminium kit cladding on MS support for extension to existing exhaust piping with bellows/ connectors all as required, specified & directed.

2

-

-

... More
Item No 90 : S & F of Retrofit emission control system for DG Sets of capacity 62.5 KVA complete including dual fuel conversion kit in existing DG Set and exhaust piping with insulation and aluminium kit cladding on MS support for extension to existing exhaust piping with bellows/ connectors all as required, specified & directed.

2

-

-

... More
Item No 91 : S & F of Retrofit emission control system for DG Sets of capacity 20 KVA complete including dual fuel conversion kit in existing DG Set and exhaust piping with insulation and aluminium kit cladding on MS support for extension to existing exhaust piping with bellows/ connectors all as required, specified & directed.

4

-

-

... More
Item No 92 : S & F of Retrofit emission control system for DG Sets of capacity 82.5 KVA complete including dual fuel conversion kit in existing DG Set and exhaust piping with insulation and aluminium kit cladding on MS support for extension to existing exhaust piping with bellows/ connectors all as required, specified & directed

2

-

-

... More
Item No 93 : S & F of Retrofit emission control system for DG Sets of capacity upto 1500 KVA complete including dual fuel conversion kit in existing DG Set and exhaust piping with insulation and aluminium kit cladding on MS support for extension to existing exhaust piping with bellows/ connectors all as required, specified & directed.

1

-

-

... More
Add : Note for the Ser item Nos 86 to 93 Retrofit Emission Control Device (RECD) Design, Manufacture, supply, installation, Testing and Commissioning of Retrofit Emission Control Device suitable for DG Set with following requirements as given below: Retro-fit emission control system should be as per statutory Authorities recommendations to achieve minimum specified particulate matter capturing efficiency of at least 70%. The emission control system shall be type tested and approved from CPCB approve laboratories any one from the following as per guideline of NGT and MoHUA. (i) Automotive Research Association of India, Pune (Maharashtra) (ii) International centre of Automotive Technology, Manesar (Haryana) (iii) Indian Oil Corporation, Research and Development Centre, Faridabad (Haryana) (iv) Indian Institute of Petroleum, Dehradun (Uttrakhand) (v) Vehicle Research Development Establishment, Ahmednagar (Maharashtra) Retro-fit emission control system of suitable rating or sizes shall be installed or retrofitted in existing exhaust pipe with required modifications and suitable design compatible for respective model of diesel engine prime mover of DG sets and have safety precaution to ensure no damage to the engine operations under any circumstances. Safety system provided to engine from higher back pressure, engine vibration, and high temperature operation to avoid any malfunction, it should be within the limits as recommended by DG OEM. The retrofit system manufacture to coordinate and take certificate from DG OEM The emission reduction will be verified after the installation of unit at site by any of the air pollution labs approved by CPCB of DPCC.

-

-

-

... More
Item No 94 : M&L for broken stone aggregate for loose filling under 11 KV four pole and arround the transformer /panel for protection of gauge 40 mm graded

80

-

-

... More
Item No 95 : M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4) complete all as specified and directed.

24

-

-

... More
Item No 96 : M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :-reinforcement where provided shall be measured and paid seprately)

4

-

-

... More
Item No 97 : S&F mild steel works as in posts and struts in fencing including cutting tops to shape as directed drilling holes notching for wire fencing/chain link fencing etc flat iron fillets, sag rods (for securing chain link fencing etc) including all necessary drilling, bolting or reveting, welding etc and embeding in concrete and securing etc. and similar works conforming to Fe- 290, grade E-165. All as specified and directed

1000

-

-

... More
Item No 98 : Supply only Chain link MS galvanisd fencing, any size or type all as specified and directed

798

-

-

... More
Item No 99 : S & F Mild steel screw bolts 5 to 10 mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long

20

-

-

... More
Item No 100 : M&L for preparation of newly steel surfacces of any description not otherwise desribed, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide zinc chrome primer surfaces complete all as specified and as directed.

50

-

-

... More
Item No 101 : M&L Rendering 15mm thick in cement mortar 1:4 on brick or concrete wall surface finished even and smooth without using extra cement

250

-

-

... More
Item No 102 : M&L for Preparing Newly Plastered Surfaces of external Walls and applying Two Coats of Cement Base Paint over a coat of primer complete all as as specified and as directed.

250

-

-

... More
Item No 103 : Fixing only Chain link MS galvanisd fencing, any size or type all as specified and directed.

300

-

-

... More
Item No 104 : M&L for shifitng ofdistribution transformer/VCB/RMU of any capacity.any size , disconnecting all connections from the transformer , shifting to new locations and reshifting disconnected transformer to location as directed and reconnecting all connections , all as per required and directed by Engr In charge.

10

-

-

... More
Item No 105 : Supply , install and erect in true vertical position steel tubular swaged welded pole for provision of 2 pole structure complete with MS base plate 6 mm thick of size 300 x 300 mm final taper, pole cap, bolts nuts washers and screws etc pole madeoutof ERW MS tubing confirming to IS 2713 part-II type 410 SP-55 (11 mtr) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide,primer and two coats of aluminium paints for portion embedded in concrete, painting with systhetic enamel paint(First Garde/quality) black and yellow at lower portion of exposed pole starting from plinth block band of 1200 mm height(4 no each strip of 150 mm width) complete all as specfied and directed. Note:- Earthwork, cement,c oncrete cross arms etc will be measured and paid under appropriate items.

2

-

-

... More
Item No 106 : Supply , install and erect in true vertical position steel tubular swaged welded pole for provision of 4 pole structure complete with MS base plate 6 mm thick of size 300 x 300 mm final taper, pole cap, bolts nuts washers and screws etc pole madeoutof ERW MS tubing confirming to IS 2713 part-II type 410 SP-55 (11 mtr) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide,primer and two coats of aluminium paints for portion embedded in concrete, painting with systhetic enamel paint(First Garde/quality) black and yellow at lower portion of exposed pole starting from plinth block band of 1200 mm height(4 no each strip of 150 mm width) complete all as specfied and directed. Note:- Earthwork, cement,c oncrete cross arms etc will be measured and paid under appropriate items.

4

-

-

... More
Item No 107 : Supplying and laying un-reinforced precast concrete cable cover, class HV, type 2 with peak, size 450mm x180mm x 40mm ISI marked layed perpenducular to the length of the cable .

94567

-

-

... More
Item No 108 : Supplying and laying un-reinforced precast concrete cable cover, class LV, type 2 with peak, size 300mmx 180mmx40mm ISI marked layed perpenducular to the length of the cable .

89116

-

-

... More
Item No 109 : Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil

14281

-

-

... More
Item No 110 : M and L for cutting of roads /trenchless technology method all as per required and directed by Engr In charge.

200

-

-

... More
Item No 111 : M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.

10321

-

-

... More
Item No 112 : M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.

3960

-

-

... More
Item No 113 : Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.

3464

-

-

... More
Item No 114 : M/L for GI Tubes,of size 50 mm dia medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.

120

-

-

... More
Item No 115 : M/L for GI Tubes,of size 80 mm dia medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.

120

-

-

... More
Item No 116 : M/L for GI Tubes,of size 100 mm dia medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.

80

-

-

... More
Item No 117 : M&L for cable route indicator for HT cable with 11000 Volts embossed in MS sheet 5mm mounted in 50mm angle iron duly painted in red , with one coat of red oxide over two coats of sunthetic emanel paint with height 300mm above GL with PCC foundation all as per required and directed by Engg in Charge.Note: Rate quotyed by contractor shall deemed to be included of excavtion and earth work.

280

-

-

... More
Item No 118 : Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 3 m in depth and getting out in any type of soil

5

-

-

... More
Item No 119 : M&L for cable route indicator for LT cable with 1100 Volts embossed in MS sheet 5 mm mounted in 50mm angle iron duly painted in red , with one coat of red oxide over two coats of sunthetic emanel paint with height 300mm above GL with PCC foundation all as per required and directed by Engg in Charge.Note: Rate quotyed by contractor shall deemed to be included of excavtion and earth work.

410

-

-

... More
Item No 120 : M&L for cable route indicator for HT joints with 11000/33000 Volts embossed in MS 5mm sheet mounted in 50mm angle iron duly painted in red , with one coat of red oxide over two coats of sunthetic emanel paint with height 450mm above GL with PCC foundation all as per required and directed by Engg in Charge.Note: Rate quoted by contractor shall deemed to be included of excavtion and earth work.Necessary sample may be approved before final execuation of material.

72

-

-

... More
Item No 121 : M&L for cable route indicator for LT joints with 1100 Volts embossed in MS 5mm sheet mounted in 50mm angle iron duly painted in red , with one coat of red oxide over two coats of sunthetic emanel paint with height 450mm above GL with PCC foundation all as per required and directed by Engg in Charge.Note: Rate quoted by contractor shall deemed to be included of excavtion and earth work.Necessary sample may be approved before final execuation of material.

250

-

-

... More
Item No 122 : Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 20x15cm

200

-

-

... More
Item No 123 : Anti-climbing device; spikes type fabricated out of M.S. bars (round,square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole

5

-

-

... More
Item No 124 : S&F in replacement 3 Layer PPR Pipes, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete for outer dia 20 mm (PN-16)

840

-

-

... More
Item No 125 : S&F the straight through joint LT from 25 sqmm 3.5/4 core to 95 sqmm 3.5 core with jointing all as required and directed at site

40

-

-

... More
Item No 126 : S&F the straight through joint LT from 120 sqmm 3.5 core to 240 sqmm 3.5 core with jointing all as required and directed at site

35

-

-

... More
Item No 127 : Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 33000 volts(E) grade, of size 3 core 185 sq mm.

400

-

-

... More
Item No 128 : S&F the straight through joint LT from 240 sqmm 3.5 core to 400 sqmm 3.5 core with jointing all as required and directed at site

20

-

-

... More
Item No 129 : Supply testing and training for cable fault locator shall be mounted on existing vehicle consist of the following:- Sur Gen Model: T-1032(10) Suitable for fault location in low/medium/high voltage power cables up to 33 KV. 1. DC High Voltage Testing up to 32 KV. 2. Limited burning current more than 200 Ma. 3. High voltage metering and mA metering on output. 4. Surge Testing Range 8/16/32 KV. 5. 1000 Joules Energy on 8/16/32 KV. Please refer to the following specification for details Pinpointing Set, Model: Dig point Sensitive acoustic and magnetic sensor to pinpoint fault. 1. Magnetic and Acoustic signal strength through bar graph and digits on LCD. 2. Coincidence figure readout i.e. Distance to the fault in milliseconds on LCD. 3. Accurate display of magnetic and acoustic indications. 4. Light weight receiver. 5. Advance noise reduaction filter for fast & accurate pinpointing. Please refer to the attached specification for details Reflect meter, Model: T-610 Reflect meter for pre-location of cable faults. 1. Digital Time Fomain Reflectometer. 2. Pulse Echo, Impulse Current & Decy methods. 3. Microprocessor based fault locator with user-friendly menu. 4. Inbuilt Wi-fi for internet connection Enabling Online support of experts to review and help in difficult fault conditions. 5. Large and automatic graph storage. 6. 10" touch screen for easy operation.

1

-

-

... More
7. Precise fault distance & cable end measurement. 8. Testing Range up to 160 KM. Please refer to the attached specification for details HIGH VOLTAGE MURRY LOOP, MODEL: T-1502 For pre- location of low & high resistance constant leakage fault. 1. Portable, Battery operated. 2. Suitable for constant leakage fault up to 5. K.V.DC. 3. Gives teading in % of cable length. 4. Accuracy up to 1% of fault distance. Please refer to the attached specification for details Connecting Cables and leads with Drum 1. 25 mtr. High voltage output cables 2. 25 mtr. Earthing cables 3. 25 mtr. Main supply cables Discharge rod with lead

-

-

-

... More
HIGH VOLTAGE MURRY LOOP, MODEL: T-1502 For pre- location of low & high resistance constant leakage fault. 1. Portable, Battery operated. 2. Suitable for constant leakage fault up to 5. K.V.DC. 3. Gives teading in % of cable length. 4. Accuracy up to 1% of fault distance. Please refer to the attached specification for details Connecting Cables and leads with Drum 1. 25 mtr. High voltage output cables 2. 25 mtr. Earthing cables 3. 25 mtr. Main supply cables Discharge rod with lead

-

-

-

... More
HIGH VOLTAGE MURRY LOOP, MODEL: T-1502 For pre- location of low & high resistance constant leakage fault. 1. Portable, Battery operated. 2. Suitable for constant leakage fault up to 5. K.V.DC. 3. Gives teading in % of cable length. 4. Accuracy up to 1% of fault distance. Please refer to the attached specification for details Connecting Cables and leads with Drum 1. 25 mtr. High voltage output cables 2. 25 mtr. Earthing cables 3. 25 mtr. Main supply cables Discharge rod with lead

-

-

-

... More
Item No 130: Deduct Schedule of Credit Rs (-) 469064

-

-

-469064



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.