Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date18 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 23,00,000
Costs
EMD
₹ 46,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689253_1Tender No
85189/P/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Features, Functions, Protections
(a) 16 character x 2 line alpha-numeric LCD display with LED backlight (b) Operator interface (c) Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory (d) Provide Alternator data fequency Control which includes provision for Service adjustment and calibration of DG control functions
(i) Voltage, frequency selection
(ii) Meter calibration
(iii) Configurable input and output set up Power Start which operates on 24 V DC batteries. Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode.
-
-
-
... More
Engine Starting – (a) The control system supports automatic engine starting, Primary and back up start disconnections are achieved by battery charging alternator feedback or main alternator output frequency. (b) Controller Model PS0602 provides configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. (c) Sleep mode increases battery life. Configurable current settings from low to minimize current draw when genset is not working.
-
-
-
... More
Engine Protective Functions includes - Configurable alarm output, Emergency stop: Annunciated whenever an emergency stop signal is received by the control
(a) Low Lube oil pressure warning and shutdown
(b) High engine water temperature warning/ shutdown
(c) Low coolant temp warning (d) Sensor failure indication
(e) Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down
(h) Cranking lockout: Control will not allow the starter to engage or to crank the running engine
(j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods. Alternator Protective functions includes (a) High and Low AC voltage shut down (b) Under and over frequency shutdown / warning (c) Loss of sensing voltage input shut down (d) Battery charger alternator
-
-
-
... More
Fuel tank: (a) Sub Base Fuel tank of 14 SWG MS sheet of adequate capacity to operate 8 hrs to 12 hrs on 100% load. (b) Base Rail: Base Rail with integral fuel tank is provided.
(c) Batteries: For electrical control circuit 12 Volts/88AH batteries for electrical starting of DG set
-
-
-
... More
AMF ELCECTRICAL CONTROL PANEL : Panel is manufactured with 14 guage CRCA sheet, floor mounting type, powder coated for weather-proof and long lasting finish, totally enclosed, front hinged cover, instrument switches and panel complete comprising of the followings :- (a) MCCB 4 Pole 200 Amps 35 KA rating at load side - 02 Nos
(b) MCB DP 20A 10 KA - 01 No
(c) MCB DP 6A 10 KA - 02 Nos
(d) MCB DP 4A 10 KA - 09 Nos
(e) Current Transformer, Class-1.5 VA, 200/5A - 04 Nos
(f) FP Contactor, 240 V AC, 2 No+2 NC, GMC-220/4, 220A AC3 - 02 Nos
(g) Indicating LED Light, R,Y, B - 09 Nos (R,Y - 06 No & B - 03 No)
(h) Illuminated Push Button with element - 01 No
(j) Mushroom head push button, press to lock, turn to release - 01 No
(k) VAF meter 0 - 500 Volts, 415 V AC, 96 x 96 mm, digital type with selector switch - 01 No
(l) DC Ammeter 0-3 Amps, 0-20 A rating, digital type, 96 x 96 mm with CT ratio 100:5 operated with 4P,3 way slector switch - 01 No
(m) 12 V DC Automatic Battery charger complete with in-built trickle / Boost Facility, 12V DC 10A rating, voltmeter charging rate indicator, selector switch , trip/boost switch - 01 No
-
-
-
... More
(n) 4 Point Alarm Annunciator with in-built hooter, test, accept and reset push button, 12V DC - 01 No
(o) Solid State single element earth fault relay with 2C/o contact, CTR-250/5A AUX 230V AC - 01 No.
(p) Suitable bus bar and control panel shall have suitable incoming / out going terminal control, circuit fuses, painted with powder coated, rust proof paint.
(q) AMF controller, DG-6 type, 12V DC rating - 01 No
(r) AUX relay, coil voltage, 12V DC 4 C/O, 14 Pin - 05 Nos
(s) AUX relay, coil voltage, 240V AC 4 C/O, 14 Pin - 01 No
(t) Thermal Overload relay, with in-built SPP feature, 3A-5A rating - 01 No
-
-
-
... More
One set of accessories (As per manufacture's instruction) :- (a) Fuel tank with locking arrangement for 08 hours running on full load
(b) Level indicator on fuel tank (c) Drain plug
(d) MS Class "C" pipe of suitable dia and length for fuel inlet from tank to engine as per Manufacturer's instruction.
(e) Fuel strainer and fuel tank with air vent.
(f) Batteries heavy duty 24 Volts 180 AH lead acid type fully charged, indication of high flow charging changed : - 01 No
(g) Cable connection from alternator to DG set control panel as directed
-
-
-
... More
Tools (As per manufacturer's instructions):- (a) 'D' spanners - 01 Set
(b) Ring spanners - 01 Set
(c) Screw driver 5" to 12 " - 01 Set
(d) Cutting plier 9 " - 01 No
(e) Hammer 2 LBS - 01 No
-
-
-
... More
Base frame arrangements . The engine and alternator would be coupled by means of specially designed flexible coupling. Both the units including the radiator would be mounted on a rigid fabricated base to form a compact arrangement. The steel shall be of Make : TISCO/SAIL or equivalent Make as approved by GE
-
-
-
... More
Sound acoustic enclosure : CPCB approved sound acoustic enclosure suitable for above generator set with complete set installed within canopy.
-
-
-
... More
Supply and laying in trenches/through pipes or laid across road /paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. cable under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area 120 Sqmm x 3.5 core complete all as specified and directed.
70
-
-
... More
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for shafts , wells, cesspits, manholes, laying of pipe and not exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
14
-
-
... More
Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25cm thick complete all as specified and directed.
9
-
-
... More
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & diected.
5
-
-
... More
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be considered for payment purpose)
4
-
-
... More
Supply and laying unreinforced precast concrete cable cover, class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed.
394
-
-
... More
M&L for 100 mm thick PCC (1:2:4) Type B-1 using 20mm graded stone aggregate as in floor/hard standing complete all as specified and directed..
0.5
-
-
... More
Supply and fix earth continuity conductor for main earthing lead 32 x 6 mm GI strip burried in ground or fix in walls with bolts complete all as specified and directed.
24
-
-
... More
Supplying and fixing 80 mm bore, ISI marked steel tubes light grade galvanised with all fittings used for cable protection complete all as specified and directed.
9
-
-
... More
Earthing complete for various equipments with galvanised steel earth plate electrode 600 x 600x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.I Strip 32 x 6 mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, PCC chamber 1:2:4, type B-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 75mm C/C both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I(2009) and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion complete all as specified and directed.
Note:- Unit rate quoted against this item is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%