Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 9,20,000
Costs
EMD
₹ 18,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692541_1Tender No
8498/KH/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Compressor hermatically sealed and Rotatory type Suitable for 1.5 Ton AC split type.
3
-
-
... More
Compressor hermatically sealed and Rotatory type for 2.0 Ton AC split type.
2
-
-
... More
Compressor inbuilt invertor type Suitable for 1.5 Ton AC split type.
3
-
-
... More
Material & Labour for rewinding of fan motor of desert cooler, split and window AC of any size with super enameled copper winding wire of existing gauge including insulation, warnishing etc, and replacement of worn out bushes, bearings, shafts, nuts, bolts and washers includind greasing, oiling, reassembling and testing the motor complete all as specified and directed for the following
-
-
-
... More
1/7 HP Suitable for desert cooler.
8
-
-
... More
1/4 HP and 1/6 HP suitable for AC any type.
10
-
-
... More
Replacement new PCB (printed circuit board ) units as existing model/make for split AC 1.5/2 Ton capacity complete all as specified and directed . Make:Blue star/Voltas/LG/Samsung
5
-
-
... More
Replacement Old/UNSV with new water lifting pump suitable for desert cooler of 1/20 Hp, 240 volts, 50 Hz, 12 watts, 1.5 mtr head capacity complete all as specified and directed.
Make:Crompton /Khaitan/Kenstar
10
-
-
... More
S & F PVC switch box including two switch & indicater of Plaza Make for desert cooler including taking down old switch box complete all as specified and directed.
5
-
-
... More
S & F new speed control regulator for desert cooler 240 volts 50 Hz, single phase, including taking down old switch, any make and any size complete all as specified and directed. Make : PLAZA/KINJAL/ANCHOR
10
-
-
... More
S & F knobs for window AC, including taking down old switch complete any make and any size, complete all as specified and directed.
5
-
-
... More
S&F in replacement desert cooler water tank suitable for desert cooler (as per existing size) made out of 22 gauge GI sheet made to shape including complete all as specified and directed .
2
-
-
... More
S & F in replacement suction valve/Liquid valve of size 1/2" & 1/4" along with dead nut, flare nut complete suitable for split AC cap 1.5/2 Ton out door unit complete all as specified and directed.
6
-
-
... More
M&L for Preparation of surfaces and applying two coat of synthetic enamel spray painting on metal surface (inner/outer) including writing SM No/MES No with paint to desert cooler of any make and size complete all as specified and directed .
11
-
-
... More
Replacement of old/UNSV with new wood wool pads / Honeycomb type of required size for desert cooler any make including complete all as specified and directed .
11
-
-
... More
Replacement of old/damaged with new front grill made out of 22 gauge GI sheet suitable for desert cooler any make/size complete all as specified and directed .
4
-
-
... More
Repair/replacement of damaged body of desert cooler, with 1 mm thick MS sheet any make complete all as specified and directed.
2
-
-
... More
S & F in replacement of old/UNSV fan motor, single phase, 230 volt ,50 Hz ,1/7 HP with blade arm 18" sweep size suitable for desert cooler, complete all as specified and directed.
Make: Khaitan/Champion/Jyoti
7
-
-
... More
S & F in replacement of defective / damaged transformer of voltage stabilizer complete all as specified and directed for following capacity:-
-
-
-
... More
(a) 5 KVA
5
-
-
... More
(b) 4 KVA
5
-
-
... More
S & F in replacement of volt meter range 0 to 300 volts, flush type square or circular for voltage stabilizer complete all as specified and directed.
5
-
-
... More
Replacement of old/UNSV fan motor 230 volt, 50 Hz for 1/4 and 1/6 HP suitable for AC window type and split type complete all as specified and directed. Make: Crompton/ Bajaj /Khaitan
8
-
-
... More
Re-filling of refrigerent gas Non CFC R 32 /R22/R 410 A /R134A of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed .
30
-
-
... More
Taking down carefully following item of any make/model after repair refixing of same or other position or depositing in MES store of AGE E/M (P) Jabalpur complete all as specified and directed.
-
-
-
... More
Desert cooler of any make and size
8
-
-
... More
Window AC/Split AC of any capacity /position
15
-
-
... More
Servicing of split type AC including pressure testing of AC, cleannig of indoor unit with blower & outdoor unit of AC washing, filter cleaning,copper tubing check etc,complete all as specified and directed.
13
-
-
... More
Servicing of window AC type including pressure testing of AC ,cleannig of unit with blower , washing, filter cleaning,copper tubing check etc, for complete all as specified and directed.
17
-
-
... More
M & L for core cutting to make provisional holes for pupose of electric wiring / drain pipe outlet / fixing of AC any type / any size or drain pipe including surface finishing complete all as specified and directed.
5
-
-
... More
Replacement of old/UNSV Ply-wood grade BWR type BB 6mm thick (five Ply) cut into required size fixed where required with all fixing are complete all as specified and directed.
5
-
-
... More
Replacement of old/UNSV Running capacitor for AC, desert Cooler of following capacity, any type and ISI make complete all as specified and directed .
-
-
-
... More
50.0 mF.
20
-
-
... More
4.0 mF.
10
-
-
... More
S&F in replacement new thermostate for AC, complete all as specified and directed.
15
-
-
... More
S&F in replacement installation and testing copper tubing of size 1/2" &1/4" along with sleeve insulation complete all as specified and directed.
16
-
-
... More
S & F in replacement switch socket combination flush type 5 Amps complete all as specified and directed. Make : PLAZA/KINJAL/ANCHOR
10
-
-
... More
S & F in repairs single pole and neutral encloser with two pin and earth plug and socket complete with one MCB SP 32/20 Amps complete all as specified and directed. Make: L & T/Legrarnd/Schinder.
8
-
-
... More
S & F in repairs MCB SP, 230 volts, 20 to 32 amps as per complete all as specified and directed.
4
-
-
... More
S & F in repairs MCB SPN, 230 volts, 32 to 40 amps as per complete all as specified and directed.
4
-
-
... More
S&F in repairs Three core copper flexible wire PVC insulated cable and PVC sheathed of size 40/0.076 mm complete all as specified and directed.
100
-
-
... More
S & F in repairs three pin plug top 15 amps ISI mark complete all as specified and directed. Make : PLAZA/KINJAL/ANCHOR
10
-
-
... More
S & F MS fan blade of AC unit size 450 mm / suitable size including taking out of old unserviceble blade complete all as specified and directed.
20
-
-
... More
S & F in repairs air filter suitable for 1.5/2 Ton split AC as per existing size complete all as directed.
20
-
-
... More
S & F in repairs black insulation cover suitable for copper tubing of any size complete all as directed.
20
-
-
... More
Replacement of old/UNSV PCB with new inbuilt inverter type PCB (printed circuit board ) units as existing model/make for split / Window type AC 1.5/2 Ton capacity complete all as specified and directed. Make:Blue star/Voltas/LG/Samsung
6
-
-
... More
Repair and fix PCB (printed circuit board ) units as existing model/make for split / Window type AC 1.5/2 Ton capacity complete all as specified and directed. Make:Blue star/Voltas/LG/Samsung
6
-
-
... More
S & F in replacement swing motor of split AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed.
Make: LG/Voltas/samsung
5
-
-
... More
S & F in replacement water tray suitable for split AC 1.5/2 Ton capacity, any type and any make/model complete all as specified and directed. Make: LG/Voltas/samsung
5
-
-
... More
S & F in replacement condensing Coil of window type/ split type AC cap 1.5/2 Ton any type and any make/model complete all as specified and directed.
5
-
-
... More
S & F in replacement cooling coil of window type/split type AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed.
5
-
-
... More
S & F in repairs switch socket combination 15 Amp flush type, 240 Volts, 50 Hz complete all as specified and directed.
8
-
-
... More
Replacement of old/UNSV PCB with new PCB (printed circuit board) units as existing model/make for Window type AC 1.5/2 Ton capacity complete all as specified and directed. Make:Bluestar/Voltas/LG/Samsung
8
-
-
... More
S & F in replacement of PVC drain pipe of 15mm dia and 0.5mm thick corrugated type complete all as specified and directed.
40
-
-
... More
S & F in replacement of remote control suitable for split AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed. Make: LG/Voltas/Bluestar/Samsung
8
-
-
... More
M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leaks including S&F in replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/suction/ discharge valves of compressors, gland packages of all angle valves, flaring of all connections framing welding etc complete all as specified and as directed for the following AC plants:- Note:- Entire work shall be carried out by the Auth rep of OEM i.e Bluestar for following plants:
-
-
-
... More
Central Air Conditioning Plant of Make : Bluestar of capacity (3x25.5) TR
1
-
-
... More
Central Air Conditioning Plant of Make : Bluestar of capacity (3x11) TR
1
-
-
... More
Opening the upper sheet and side sheet of AHU’s of the following central AC plants for access to cooling coil, including M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and descaling of cooling coil of AHU, re-fixing and changing of V Belt both set with necessary fitting and T&P for mounting complete all as specified and directed. Note:- Entire work is to be carried out by OEM i.e Bluestar for following plants:
-
-
-
... More
Central Air Conditioning Plant of Make : Bluestar of capacity (3x25.5) TR
1
-
-
... More
Central Air Conditioning Plant of Make : Bluestar of capacity (3x11) TR
1
-
-
... More
M&L for repair of AHU motor suitable for AC plants with following capacity by dismounting it from weather making unit of AHU replacement of Bush, bearing by opening nuts bolts and removing electrical connections of the motor, replacement of V type Belt with new belt, replacement of stator and rotor assembly rewinding of motor, replacement and alignment of shaft complete all as specified and as directed. Rate is inclusive of the replaced items.
-
-
-
... More
Central Air Conditioning Plant of Make : Bluestar of capacity (3x25.5) TR
1
-
-
... More
Central Air Conditioning Plant of Make : Bluestar of capacity (3x11) TR
1
-
-
... More
M&L for replacement of cast iron Y type strainer of size 50mm flanged type as per existing complete all as specified and as directed. Make: Zoloto/Leader
1
-
-
... More
M&L for evacuation of gas from the system into the empty cylinder (arranged by contrator as required), pumping down to the system, descaling condenser unit of the following capacity plants after bypassing the cooling tower, pumps & supply and circulation of the descalling solution (ANTI SCALENE SCALE FOEE-100) with pump brushing the tubes and where required drilling the stubborn scalling without damaging the tube, replacement of deshed end gasket and unserviceable nuts and bolts assembling back complete testing and commissioning including removing air lock, recharging the gas taken out of the system complete all as specified and directed.
Notes:-(i) Descaling pumps, nylon brush, acid including storage containers, drill and drill bits to be arranged by contractor and cost of the same deemed to be included in the rate quoted . (ii) Entire work shall be carried out by OEM i.e Bluestar .
2
-
-
... More
M&L for Vacuum the system and after maintaining vacuum for 24 hours supply and charge refrigerant gas 407 C complete all as specified and directed., Make:-Mafron/Refron
2
-
-
... More
M&L for painting of AC Plant as per existing colour including Compressor, condenser, motor, chiller pump, AHU, cooling tower including base and all pipe lines & connected valve etc complete all as specified and directed. Make of Paint-Asian/Indigo
1
-
-
... More
M&L for repair of indoor type LT panel board and replacement of unserviceable switch/control gears and meters, selector switches, indicator lamps etc including rewiring and extension of incoming and outgoing cables by opening of loops and provisioning of cable lugs /thimbles as required and replacement of rusted sheet metal with existing size MS sheets by necessary arc/gas welding(Approx sheet 1 Sqmtrs ) including two coats of synthetic enamel spray painting over a coat of red oxide primer both inside and outside surfaces of Panel Board including rewriting of identification for controls complete all as specified and directed.
Note:- MCCB, contactors, relay, single phase preventer, timer, Change over, Indicator lamp, Selector switch, Ammeter, Voltmeter etc given below will be measured and paid seperately under respective items of this schedule.
2
-
-
... More
M&L in repair for thermal insulation for ducts/chiller with 19mm thick nitrile rubber insulation, complete all as specified and directed
60
-
-
... More
M&L in reapir for air ducting fabricated out of GI Sheet of thickness as under in diffirent size and shape complete all as specified and directed for following gauges:
-
-
-
... More
Made out of 22 Gauge.
12
-
-
... More
Made out of 24 Gauge.
15
-
-
... More
M&L in replacement of PUF insulation 36 mm of density 36 kg/cum and 26 gauge GI cladding complete with necessary mounting arrangement like clamps , nut bolt etc suitable for existing AC Plant cap upto 100 TR complete all as specified and as directed.
10
-
-
... More
M&L in replacement duct filter with ss material filter media capacity shall capable 5 microns as per existing, suitable for AC plant of capacity upto 75 TR, package units as per site requirement complete all as specified and directed.
1
-
-
... More
M&L in replacement strip heaters of cap 3KW (3000 W) complete all as specified and directed.
1
-
-
... More
Taking out the unserviceable motor and rewinding of motor capacity 7.5 HP with same gauge with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the following items complete all as specified and directed.
(a) Replacement of ball bearing. Make: SKF-02 Nos (b) Replacement of bush (c) Replacement of cooling fan - 01 Nos.
1
-
-
... More
M&L for opening of pump 7.5 HP centrifugal for repair and replacement of following unserviceable parts including re-fixing of all the same and testing and commissioning complete all as specified and as directed.
(a) Replacement of gun metal impeller. -01 Nos (b)Replacement of gun metal bush -02 Nos (c) Replacement of ball bearing. Make: SKF - 01 Nos. (d) Replacement of oil seal -01 Nos. (e) Replacement of gland -01 Job
1
-
-
... More
Attending emergency break down & making functional of AC Plant of Make- Bluestar of capacity 3x 11 TR ventilation system complete exists at NERC OFK Jabalpur alongwith equipments as associated complete all as specified and directed. Notes:- (i) The cost of parts/ accessories/ materials if required to be replace, same shall be paid seperately under respective items here-in-after as Supply & fix in replacementas considered/ taken for item No. 02 above.
(ii) Emergency break down shall be attend immediately ON CALL, if emergency break down not attended immediately on GE's call, a lump sum recovery of Rs. 10000.00 on account of penalty shall be made from the contractor's dues/ payment .
3
-
-
... More
Attending emergency break down & making functional of AC Plant of Make- Bluestar of capacity 3 X 22.5 TR ventilation system complete exists at LPR Jabalpur alongwith equipments as associated complete all as specified and directed. Notes:- (i) The cost of parts/ accessories/ materials if reequired to be replace, same shall be paid seperately under respective items here-in-after as Supply & fix in replacementas considered/ taken for item No. 01 above.
(ii) Emergency break down shall be attend immediately ON CALL, if emergency break down not attended immediately on GE's call, a lump sum recovery of Rs. 10000.00 on account of penalty shall be made from the contractor's dues/ payment .
3
-
-
... More
Supply & Fix in replacement heating coil of suitable layers, shape and size as per existing of capacity 03 KW complete all as specified and directed. Make:- Voltas or Carrier or Blue Star or Aeco or Universal as approved by GE.
4
-
-
... More
Supply & fix in replacement cooling coil of suitable layers, for central AC of 11 TR and 22.5 TR capacity, shape and size as per existing complete all as directed.
Make:- Voltas or Carrier or Blue Star or Aeco or Universal as approved by GE.
4
-
-
... More
M&L in replacement for Cooling tower water collection FRP tray sheet of having dimension (280cm X135cm X 44cm) as existing at LPR Central AC plant Cooling Tower including fixing & leak proof testing complete all as Specified and directed.
1
-
-
... More
M&L for removing the existing choked fins of existing cooling towers and supply and fixing new PVC fins of size suitable for cooling tower of 3 X 25.5 TR or 3 X 11 TR capcity as per existing complete all as specified and directed. Make:- Voltas or Carrier or BlueStar or Aeco or Universal as approved by GE.
60
-
-
... More
Supply only power contactor 3 pole, ML-2 type with 2 NO + 2 NC aux contracts, 415 Volt, 50 Hz, rating 32 Amps to be fixed under item No. 53 here-in-before complete all as specified and directed. Make:- Siemens or L&T as approved by GE.
3
-
-
... More
Supply only MCCB 4P with enclosure, 415 volts, 50 Hz, 400 Amps with breaking capacity 35 kA to be fixed under item No. 53 here-in-before complete all as specified and directed. Make:- Legrand/L&T/ C&S as approved by GE.
1
-
-
... More
Supply only MCCB 4P with enclosure, 415 volts, 50 Hz, 200 Amps with breaking capacity 25 kA to be fixed under item No.53 here-in-before complete all as specified and directed. Make:- L&T/ Legrand/C&S approved by GE. .
1
-
-
... More
Supply only MCCB 3 POLE with enclosure, 415 volts, 50 Hz, 100 Amps with breaking capacity 16 kA to be fixed under item No. 53 here-in-before complete all as specified and directed. Make:- L&T/ Legrand / C&S as approved by GE.
1
-
-
... More
Supply & fix in replacement power indication lamps with complete accessories 230 volts, single phase as per existing duly approved by Engr-in-Charge to be fixed under item No. 53 here-in-before complete all as specified and directed.
15
-
-
... More
Supply & fix in replacement voltage selector switch complete 230 volts, as per existing duly approved by Engr-in-Charge to be fixed under item No. 53 here-in-before complete all as specified and directed.
5
-
-
... More
Supply & fix in replacement ampere selector switch complete 230 volts, as per existing duly approved by Engr-in-Charge to be fixed under item No. 53 here-in-before complete all as specified and directed.
3
-
-
... More
Supply & fix in replacement over load relay range 9 to 15 Amps, MN-2 type to be fixed under item No. 53 here-in-before complete all as specified and directed.
3
-
-
... More
Supply & fix in replacement over load relay range 3 to 5 Amps, MN-2 type to be fixed under item 53 here-in-before complete all as specified and directed.
3
-
-
... More
Supply & fix in replacement butter fly valve with side handle operated type of 80 mm dia to be fixed under item No.53 here-in-before complete all as specified and directed. Make: Zoloto, Upadhyay, Leader
5
-
-
... More
Supply & fix in replacement butter fly valve with side handle operated type of 100 mm dia complete all as specified and directed. Make: Zoloto, Upadhyay, Leader
5
-
-
... More
Supply & fix in replacement temperature gauge (digital type) bottom connected, direct mounting type, range 0 to 100° C or 32 to 212°F complete as per existing make duly approved by GE to be fixed under item No. 53 here-in-before complete all as specified and directed.
8
-
-
... More
Supply & fix in replacement V belt 'B' section of size A-56 as per existing to be fixed under item No. 53 here-in-before complete all as specified and directed.
5
-
-
... More
Supply & fix in replacement water flow switch of type RC-61 MWP 150 PSI electric rating 250 volts, 50Hz, 15 Amps with sensor and lead as per existing make duly approved by GE including testing and commissioning complete all as specified and directed.
5
-
-
... More
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 3.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauge and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
2
-
-
... More
M&L for dismantling & taking out the old unserviceable/ burnt winding wire after taking out the 3 phase, 50 Hz, 415 volts electric motor of capacity 5.0 HP from existing position and rewinding the same with superior quality copper winding wire of suitable gauge and number of turns including insulating materials (PVC insulation sleeve, tape, film paper, varnish, cotton & heating process etc) as required including replacement of existing DE & ND side bearings and re-fixing the motor in existing position after re-assembling and testing on completion complete all as specified & directed.
2
-
-
... More
M&L for repair/ overhaulling of hot water generator of capacity 54 KW out put by unscrewing and draining out to detect leakages, welding where-ever necessary, removing burnt/ unserviceable heating element from bottom level of tank, scraping out rust/ sludge including putting new insulation sleeves to bare conductors, fixing of new/ fresh heating elements of suitable capacity, replacement of PCC kit with new one and reassembling all the dismentled components and testing on completion for satisfactory operation complete all as specified & directed.
1
-
-
... More
M& L in replacement for perforated cable tray of size 100x 50 Galvenised Iron for support of cables from AHU to AC plant including all fixing accessories ,nuts, bolts and proper support of MS channels and connected fixing arrangements complete all as specified and directed.
80
-
-
... More
M&L for complete repair/ over-hauling to FRP based cooling tower of 3 X 11 TR capacity by dismantlinlg fins, couplings, cooling fan, draining out of water moving algey deposited and cleaning, servicing of mechanical components, welding wherever necessary, scraping out rust/ sludge including putting descaling solution and replacing of gear box, bearings, gear oil, mechanical couplings as per site requirement and over-hauling the complete transmission system of cooling tower and painting the complete system as per existing duly approved by GE and reassembling all the dismentled components and testing on completion for satisfactory operation complete all as specified & directed.
1
-
-
... More
M&L for complete repair/ over-hauling to FRP based cooling tower of 3 X 25.5 TR capacity by dismantlinlg fins, couplings, cooling fan, draining out of water moving algey deposited and cleaning, servicing of mechanical components, welding wherever necessary, scraping out 1ust/ sludge including putting descaling solution and replacing of gear box, bearings, gear oil, mechanical couplings as per site requirement and over-hauling the complete transmission system of cooling tower and painting the complete system as per existing duly approved by GE and reassembling all the dismentled components and testing on completion for satisfactory operation complete all as specified & directed.
1
-
-
... More
M&L for PVC mat of size not less than 2.0M X 1.0M X 20-25mm thick of colour and design as approved GE complete all as specified & directed.
Make:- CELLO or SUPREME or AMKO as approved by GE. Note:- Mat shall be of standard class PVC but not re-cycled.
1
-
-
... More
Supply and fix in Repair pressure gauge of size 4"dial 0-10 kg/cm2 rating including fixing accessories valve ,threads ,pop and checking for leakages if any, as per existing make duly approved by GE complete all as specified & directed.
3
-
-
... More
Supply and fix in Repair pressure gauge of size 4"dial 0-15 kg/cm2 rating including fixing accessories valve ,threads ,pop and checking for leakages if any, as per existing make duly approved by GE complete all as specified & directed.
4
-
-
... More
Supply & fix in repair discharge non return sluice valve of dia 80 mm as per existing duly approved by GE suitable for Air Conditioning Plant after shut down the air conditioning unit & opening of compressor and taking out of old unserviceable discharge NRV and leakage testing on completion at desired pressure and commissioning complete all as specified & directed.
2
-
-
... More
Supply and fix in repairs, 35/36 watt new generation energy saving and environmental friendly long life LED security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07 on bldg wall with and including pipe bracket made out of G.I tubing 32/40 mm dia bore medium grade ISI marked 1.20m long bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/ MS clamps & 12mm dia bolts, nuts & washers etc and two coat painting of approved colour on brackets compltely with and including synthetic enamel paint and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Make:- Havells Cat part No. ENDURAPEARLNEOSL40WLED757PASYTOPC or equivalent model of make- Philips or Crompton or WIPRO or Bajaj as approved by GE.
5
-
-
... More
Supply and Fixing in repair RELATIVE HUMIDITY-TEMPERATURE INDICATOR CUM CONTROLLER complete all as specified and directed. Model No: humitherm IS 96x96mm
Input/Out put configuration
Display: 4+4digit, 0.56" bright LED, Resolution: 0.1 for Temperature & RH
Input 1& 2: Dry & Wet
Temperature Range: 0-100
RH Range: 1% to 99.99%
Transmiter Excitation Voltage:+12VDC [5 V , 25A]
Output 1: Temp. Control , ON/OFF, Relay: NO/NC, or SSR
Output 2: RH. Control , ON/OFF, Relay: NO/NC, or SSR
Output 3: Temp. Alarm , ON/OFF, Relay: NO/NC, or SSR
Output 4: RH Alarm , ON/OFF, Relay: NO/NC, or SSR
Supply : 85 to 250V AC
With dry and wet Rtd bulb assembly and 2 nos RTD sensor (Dry & Wet bulb) along with 5m Teflon cable
1
-
-
... More
Earthing complete for various equipments with galvanised steel earth plate electrode 600 x 600x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.I Strip 32 x 6 mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, PCC chamber 1:4:8, type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 12mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 100mm center to center both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion complete all as specified and directed. Note:- Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate.
4
-
-
... More
Schedule of credit amount of Rs. 41167.00 to be deducted during AOC
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%