Military Engineer Services Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Services
Electrical and Electronics
Eprocure
Opening Date10 May 2018
Closing Date24 May 2018
Tender Amount₹ 29,62,500 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Bearing Bush (Front)

1

-

-

... More
Bearing Bush (Rear)

1

-

-

... More
Half section bearing (set of two)

4

-

-

... More
Connecting rod bolts & nuts

4

-

-

... More
Piston with piston pin & rings

2

-

-

... More
Suction valve ring plate

4

-

-

... More
Discharge valve ring plate

4

-

-

... More
Spring for unloading ring

8

-

-

... More
Taflon ring for Suction/ Discharge valve

3

-

-

... More
Tyre coupling for Voltas compressor

1

-

-

... More
Repair & relaying of Electrical interlocking wiring of LT panel of AC plant including all connected lux, cable, fuzes, complete all as specified and directed . NOTES :- (i) The cost of minor spares required including connector, lux, wire/cable, fuses required is deemed to be included in the quoted rate. (ii) Spares incorporated during repair of the electric panel will be measured separately under relevant item.

1

-

-

... More
Contactors as per existing Make: L&T , Legrand

3

-

-

... More
Timer 30-120 Sec. (L&T, Selec)

3

-

-

... More
Relay 17.5-22 Amp Make -L&T Siemans, Legrand

2

-

-

... More
ALV D-2 single phase preventer Make : L&T/Minilec

1

-

-

... More
MCB TPN 63 Amps, 10 KA Make -Siemens, Legrand, Hagger(L&T)

2

-

-

... More
MCB SP 32Amps, 10 KA Make -Siemens Legrand, Hagger(L&T)

1

-

-

... More
Relay, 5.5 - 8.5 Amps Make -Siemens Legrand, Hagger(L&T)

1

-

-

... More
Relay, MN-2 10-25 Amps Make -Hagger(L&T), Siemens , Legrand

1

-

-

... More
Digital type Ammeter 3 phase & CT coil (Make- Conzerv/Selec/ AE)

3

-

-

... More
ON/OFF switch As per sample

2

-

-

... More
Digital type Voltmeter 3 phase (Make- Conzerv/Selec/ AE )

2

-

-

... More
Contactor Model No - 3VU 1640 - including with NO/NC Make :Siemens/ L&T

1

-

-

... More
Indicator (R-Y-B ), 15mm dia, Neon type As per sample

9

-

-

... More
Timer 0-30 Sec. Make: L&T , Legrand

3

-

-

... More
HRC Fuse 63A ( Havells, Indoasian and C&S)

12

-

-

... More
Terminal plate for any type motors as per existing

3

-

-

... More
Conector 6Amp 12Way

5

-

-

... More
Conector 16Amp 06Way

5

-

-

... More
M&L for Overhauling / repair of the compressor capacity 10 TR Model FK-4 (Kirloskar Make) by means of isolating the compressor from the system by putting dummy plates to the suction and discharge valves, dismantling of the compressor, separating into components, inspecting, cleaning all the parts completely, carrying out necessary machining work as may be required on the crank shaft, replacement of unserviceable parts. reassembling of the compressor, Leak testing of the compressor for 12 Hrs, charging of fresh compressor oil upto the necessary level and connecting the compressor with the system. Charging of refrigerant gas after putting the system on vacuum, running the plant and watching the performance for smooth running. NOTES :- (i) The cost of minor spares required including Gasket set, required is deemed to be included in the quoted rate. (ii) Spares incorporated during repair of the compressor will be measured separately under relevant item.

2

-

-

... More
Main bearing bush front end.

2

-

-

... More
Main bearing rear end.

2

-

-

... More
Valve Plate Assembly including suction and discharge rod

3

-

-

... More
Connecting rod as per site of suitable size

8

-

-

... More
Piston with piston Pin & rings

6

-

-

... More
Shaft seal assembly

3

-

-

... More
Oil Pump Assembly

2

-

-

... More
Connecting rod nuts & bolts of suitable size

12

-

-

... More
Suction strainer

1

-

-

... More
Taflon ring for Suction/ Discharge valve

3

-

-

... More
A-72 (AHU)

2

-

-

... More
B-70 (compressor motor )

2

-

-

... More
A -76 (AHU)

2

-

-

... More
A -80 (AHU)

2

-

-

... More
B-117 /120 (cooling tower)

2

-

-

... More
B- 84 (cooling tower)

2

-

-

... More
LP cut out MP-1

1

-

-

... More
HP cut out MP-5

1

-

-

... More
OP Cut Out MP-55

2

-

-

... More
LP/HP Cut Out MP-15

2

-

-

... More
Supply and fix in repairs water pressure cut out Type IPSD 50 including necessary control wiring with 2.5 Sq. mm multistranded copper conductor cable in flexible / rigid MS Conduit fixed to wall ceiling / wall / laid in floor. Make: Indofoss / Danfoss

2

-

-

... More
Supply and charging refrigerant gas F-22 in returnable cylinder. Make : Mafron / Freon NOTE :- Gas supplied by the contractor will be taken on ledger charge by the deptt.

122

-

-

... More
Supply and filling of new compressor oil No - 68 suitable for AC Compressor. Make : Castrol / Servo

20

-

-

... More
Supply and Fix in repairs of angle Valve, brass 1/4" for return suction line including refixing as existing at site complete all as directed. Make : Castle ( or) Equivalent

1

-

-

... More
Supply and fix in repairs Shut Off valve brass 1/4" bore complete with and including replacement of flair nut , nut and bolts all as directed. Make : Castle ( or) Equivalent

1

-

-

... More
Supply & Fix in repairs of condenser safety valve, brass 0 to 350 PSI sealed of any size confirming to ISI including evacuation of refrigeration gas and recharging of taken out gas all as directed by Engineer-in-charge. Make - Castle/Henry/Brassomatic

2

-

-

... More
0 to 200 PSI or equivalent in Kg/cm2.

2

-

-

... More
0 to 300 PSI or equivalent in Kg/cm2.

2

-

-

... More
(-) 30 to 200 PSI or equivalent in Kg/cm2.

2

-

-

... More
0-4.2 Kg / sqcm.for water pressure Guage

2

-

-

... More
Supply and fix in repairs Water Temperature Guage industrial Type 0- 50 Deg C. Make Feibig , H Guru Or equivalent

4

-

-

... More
Supply and charging refrigerant gas R-407C in returnable cylinder. Make : Mafron / Freon NOTE :- Gas supplied by the contractor shall be taken on ledger charge by the deptt.

100

-

-

... More
Supply and filling of new compressor oil polyster lubricant grade 160-SZ suitable for Scroll compressor AC plant. Make : Danfoss/Emcorf (or) Equivalent

7

-

-

... More
M&L for descaling the condenser with hot water and chemical (paras-11) and reassembling the condenser connecting up and testing including all opening, closing, testing and complete all as specified and directed by EIC. Make of chemical for descaling: PARAS-11

9

-

-

... More
Upto 5 HP ( Condensor, CT fan pump motor)

3

-

-

... More
Upto 7.5 HP (for AHU)

1

-

-

... More
Upto 15 HP (for Compressor Motor)

1

-

-

... More
Upto 20 HP (for Compressor Motor)

1

-

-

... More
CT fan roller bearing of size 30204 J2/Q Make : SKF/ NBC

4

-

-

... More
Bearing for cooling tower motor 1.5 / 2 HP Make : SKF/ NBC

2

-

-

... More
Ball brass valves, high pressure with Polyethylene float and fly nut complete screwed for Iron pipe or brass ferrule of size 20 mm dia

4

-

-

... More
CT fan Housing As per sample

1

-

-

... More
M&L for Cooling Tower PVC Fins size - 300X600X150mm complete all as specified and directed. As per sample

120

-

-

... More
S&F Pilot solenoid coil 3 way complete all as specified and directed. Make : As per sample

3

-

-

... More
M&L for painting of AC plant equipments and connected pipe lines including cleaning of existing old paint surface for re painting and applying two coats of synthetic enamelled paint of existing colour code on compressor , motor , condensor, suction / discharge pipe line, liquid line, Hot water pipe line, stand and structure complete all as specified and directed .

2

-

-

... More
M&L for descaling the condenser with hot water and chemical (HCL) and reassembling the condenser connecting up and testing including all opening, closing, testing and complete all as specified and directed by EIC . Make of chemical for descaling: HCL

9

-

-

... More
Supply and fixing, or commissioning of existing Condensor Pumps having capacity of 5HP rating, 3 phase , 50 Hz, complete all as specified and directed . Make of Pump: Kirloskar, CG.

2

-

-

... More
Supply and fixing Pressure release valve size 20 mm dia for Hot water tank top side of hot water boiler complete all as specified and directed .

2

-

-

... More
Supply and fixing Heating element threded type capacity 3KW as per sample (each row 3 heaters) proper fixing in heater box with opening , closing system of heater box complete all as specified and directed .

9

-

-

... More
Supply and fixing Heating element threded type capacity 6KW as per sample (each row 3 heaters) proper fixing in heater box with opening , closing system of heater box complete all as specified and directed .

9

-

-

... More
Repair & replacement of cold water storage tank cleaning and insulation 50 mm thick glass wool with water proof insulation complete tank all as specified and directed

1

-

-

... More
S&F in repairs dry & wet bulb thermometer mercury filled and graduated on tube including removing existing unserviceable thermometer all as directed. Make : USHA/ Dimple

12

-

-

... More
AC plant No - 4 : Outsourcing for operation around clock with one skilled operator at each shed i.e. 03 skilled operator for 03 sheds at a time and comprehensive maintenance of Central type AC plants direct expansion type comprising of 3 VOLTAS compressors (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric meters of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for the following capacity :- central air conditioning plant of capacity not less than 34 TR (4 x 8.5 TR working and 2 x 8.5 TR stand by) complete with all accessories as specified and directed by engineer-in-charge (for shed Nos 4, 6 & 21)

4

-

-

... More
AC plant No - 5 : Outsourcing for operation around clock with one skilled operator at each shed i.e. 03 skilled operator for 03 sheds at a time and comprehensive maintenance of Central type AC plants direct expansion type comprising of 3 VOLTAS compressors (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric meters of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for the following capacity :- central air conditioning plant of capacity not less than 34 TR (4 x 8.5 TR working and 2 x 8.5 TR stand by) complete with all accessories as specified and directed by engineer-in-charge.

4

-

-

... More
AC plant No - 6 : Outsourcing for operation around clock with one skilled operator at each shed i.e. 03 skilled operator for 03 sheds at a time and comprehensive maintenance of Central type AC plants direct expansion type comprising of 3 VOLTAS compressors (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric meters of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for the following capacity :-central air conditioning plant of capacity not less than 34 TR (4 x 8.5 TR working and 2 x 8.5 TR stand by) complete with all accessories as specified and directed by engineer-in-charge

4

-

-

... More
AC plant No - 13 : Outsourcing for operation around clock with one skilled operator and Preventive maintenance of Central type AC plants direct expansion type comprising of 3 VOLTAS compressors (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric meters of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for :- 3 x 15 TR in shed No. 13 daily 3 shifts (Running capacity 30 TR) ( for 11 months only)

11

-

-

... More
AC plant No - 21 : Outsourcing for operation around clock with one skilled operator at each shed i.e. Three skilled operator for 03 sheds at a time and comprehensive maintenance of Central type AC plants direct expansion type comprising of 3 VOLTAS compressors (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric meters of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for the following capacity :-central air conditioning plant of capacity not less than 34 TR (4 x 8.5 TR working and 2 x 8.5 TR stand by) complete with all accessories as specifiedand directed by engineer-in-charge.

4

-

-

... More
AC plant No - 53 : Outsourceing for operation around clock with one skilled operator and Preventive maintenance of Central type AC plants direct expansion type comprising of 3 FK -4 Model compressors Make : Kirlosker (one standby out of 3 Nos.), and water cooled scroll compressor of capacity 12 TR Make: Voltas (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric motors of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for :- 3 x 10TR in shed No. 53 daily 3 shifts (Running capacity 20TR) ( for 11 months only)

11

-

-

... More
AC plant No - 54 : Outsourcing for operation around clock with one skilled operator and comprehensive maintenance of Central type AC plants direct expansion type comprising of 3 VOLTAS compressors (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric meters of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for the following capacity :- water cooled chilled water central air conditioning plant of capacity not less than 24TR (2 x12 TR working + 1 No 12 TR standby) complete with all accessories as specified & including cooling tower, for rooms / area.

4

-

-

... More
AC plant No - 57 : Outsourceing for operation around clock with one skilled operator and Preventive maintenance of Central type AC plants direct expansion type comprising of 3 FK -4 Model compressors Make : Kirlosker (one standby out of 3 Nos.), and water cooled scroll compressor of capacity 12 TR Make: Voltas (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric motors of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for :- 3 x 10TR in shed No. 53 daily 3 shifts (Running capacity 20TR) ( for 11 months only)

11

-

-

... More
AC plant No - 84 : Outsourceing for operation around clock with one skilled operator and Preventive maintenance of Central type AC plants direct expansion type comprising of 3 FK -4 Model compressors Make : Kirlosker (one standby out of 3 Nos.), condensers, cooling tower pipe line from cooling tower to pumps, refrigerant piping all gauges controls, expansion valves, filters, suction and discharge valves, electric motors of compressors, blower motors, pump sets including all starters of panel motors, electrical panel bus bars, insulators, indicator lamps, RH micro filters, humidifiers, heaters etc. complete per shift of 8 hours duration for :- 3 x 10TR in shed No. 84 daily 3 shifts (Running capacity 20TR) ( for 11 months only)

11

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.