Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date4 Jan 2025
Closing Soon1 Feb 2025
Tender Amount₹ 15,00,000
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_691923_1Tender No
83980/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender documents with errata and amendments
BOQ Items
... More
M&L for 10mm thick ready mix conceret on wall/ceiling finishing the surfaces fair & even without using extra cement complete all as specified and directed.
(Make: Ultratech Readyplast, JSW Enduraplast, Hiscon Industries or equivalent)
55
-
-
... More
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and as directed.
55
-
-
... More
M&L complete removal of existing treatment on wall surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed.
100
-
-
... More
M&L for preparation of old plastered or unplastered surfaces of walls and applying one coats of oil bound distemper, complete all as specified and as directed.
9000
-
-
... More
M&L for complete removal of existing treatment on wall surfaces and applying two coats oil bound distemper over one coat of Putty as approved (wherever required) complete all as specified and directed.
1000
-
-
... More
M&L for applying one coat of white cement based wall care putty 1.5 mm thick on walls complete all as specified and directed.
500
-
-
... More
M&L for preparation of old or previously treated surfaces of ceilings and applying one coats of oil bound distemper complete all as specified and as directed.
800
-
-
... More
M&L for preparation of old or previously treated surfaces wood/wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
400
-
-
... More
M&L for preparation of old or previously treated surfaces of steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat synthetic enamel paint complete all as specified and directed.
300
-
-
... More
Hacking out old glass (any thickness size quality or description) from wooden frame or stone, concrete or brick surrounds glazed with putty or fixed with beads complete all as specified and directed.
12
-
-
... More
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each complete all as specified and directed.
10
-
-
... More
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in eachpane complete all as specified and directed.
2
-
-
... More
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
2.5
-
-
... More
M&L cement concrete Type B-1, 1:2:4 using 20 mm graded stone aggregate as in bed blocks, lintels, cills, steps, seismic and other similar bands, kerbs, coping, benching and like etc incl necessary form work complete all as specified and directed.
1.5
-
-
... More
Providing, cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
1
-
-
... More
M&L in repairs 18/19 mm thick WPC panels solid decorative type for kitchen cabinet , fixed with stainless steel cabinet hinges to plain WPC panel frame-work, complete all as specified and directed. WPC to be fixed with stainless steel cabinet hinges of required size all as per direction of EngineerIn- Charge. (Note: stainless steel cabinet hinges, handles and necessary S.S screws shall be including) complete all as specified and directed.
100
-
-
... More
S&F in repairs PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints laid in trenches, floors or fixed in walls complete all as specified and directed.
55
-
-
... More
S&F in repairs PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints laid in trenches, floors or fixed in walls complete all as specified and directed.
20
-
-
... More
Taking down Shutters of any description n exc 1 sq. m each complete all as specified and directed.
40
-
-
... More
S & F for Powder Coating minimum thickness of powder coating (50 micron) aluminium frame and shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.complete all as specified and directed.
500
-
-
... More
M&L for Sheet glass 4.0mm thick ordinary quality and glazing in square exc n 0.5 sq. m in each in aluminium frame complete all as specified and directed.
24
-
-
... More
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
12
-
-
... More
Taking down existing water proofing treatment of any description incl PCC padding, cement plaster any thickness from roof surfaces, cleaning of roof and prepairing it for further treatment incl make good necessary dubbing out wherever required and removing rubbish from site complete all as specified and directed.
400
-
-
... More
M&L for provn of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified below:
(a) 10 mm thick plaster in CM 1:4 mixed with and including water proofing compound @3% by weight of cement applied over roof slab. After the plaster is cured the roof will be tested for water tightening by ponding with water for seven days for any seepage / leakages etc. if any seepage is observed the rectification will be carried out by pressure grouting under the pressure of 5 Kg/Sqcm using cement-based cement grout. After the surface is repaired the slab will be tested for watertightness against before processing further treatments. (WPC will be paid separately).
(b) The surface of the roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets, the grove shall be cut around to tuck in the treatment as pipes, chimneystacks etc. and other similar situations to ease up about corners.
(c) Bituminous primer conforming to IS: 3384-1965 @ 0.30 Kg/Sqm to be applied and prepared surface till the surface is properly impregnated.
(d) APP modified water proofing membrane as specified shall be laid on the primer surface by torch application method as per manufacturer’s instructions, The overlaps while torching shall be 100 mm in both directions (longitudinal and transverse directions). All overlap joints shall be sealed thoroughly by thermofusing both the membrane layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer.
400
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles and rubbish off the permises complete all as specified and directed.
83
-
-
... More
M&L for 25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate in floor and rough finished surface to receive floor finishes, complete all as specified and directed.
65
-
-
... More
M&L for Vitrified ceramic coloured (light) tile 7-8mm thick(square/rectangular) polished, area of each tile not exceeding 0.36 Sqm as in floors over and including 15 mm thick screed bed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed.
45
-
-
... More
M&L for Vitrified ceramic coloured (light) tile 7-8mm thick(square/rectangular) polished, area of each tile not exceeding 0.36 Sqm on vertical surfaces such as skirting, dado and risers to steps etc over & including 10 mm thick rendering in CM 1:4 set & jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified and directed.
8
-
-
... More
M&L for non skid ceramic coloured tiles 7mm to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm, but not exceeding 0.18 Sqm , in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed.
20
-
-
... More
M&L for coloured glazed ceramic tiles of size 450mm X 300mm X 7mm thick in vertical surface, set and jointed over and including 10 mm thick rendering even and rough in CM1:4 for backing of tiles, jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
10
-
-
... More
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, call bell and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
94
-
-
... More
Dismantling/taking down of unserviceable old existing service /submain wire of any size complete all as specified and directed.
40
-
-
... More
Dismantling/taking down of unserviceable distribution boards with MCBs/metal sheet enclouser complete all as specified and directed.
5
-
-
... More
M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FR-LS H cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates)
20
-
-
... More
All as per Srl item No -37 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed.
9
-
-
... More
All as per Srl item No -37 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
6
-
-
... More
All as per Srl item No. 37 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire complete all as specified and directed.
6
-
-
... More
All as per Srl item No. 37 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire complete all as specified and directed.
5
-
-
... More
M&L for Casing caping/conduit point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FR-LS H cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates)
20
-
-
... More
All as per Srl item No -42 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed.
10
-
-
... More
All as per Srl item No -42 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
5
-
-
... More
All as per Srl item No. 42 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire complete all as specified and directed.
8
-
-
... More
All as per Srl item No. 42 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire complete all as specified and directed.
5
-
-
... More
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed.
70
-
-
... More
S & F in repair socket out let 5 pin 5/6 Amps complete all as specified and directed.
30
-
-
... More
S&F in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
20
-
-
... More
S&F in repair ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated complete all as specified and directed.
20
-
-
... More
S & F in repair lamp holder insulated PVC/Polycarbonate body with back plate for conduit /batten fittings complete all as specified and directed.
5
-
-
... More
S & F in repair stepped type electronic fan regulator single / double module flush type on the existing phenolic laminated sheet etc. as reqd. complete all as specified and directed.
5
-
-
... More
S & F in repair modular switch one way 6 Amp one module, 240 volts complete all as specified and directed.
10
-
-
... More
S & F in repair modular bell push 6 Amp one module, 240 volts complete all as specified and directed.
2
-
-
... More
S & F in repair modular switch one way 16 Amp one module, 240 volts complete all as specified and directed.
5
-
-
... More
Supply and fixing in repair modular socket outlet 2-in-1, 2/3 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
5
-
-
... More
Supply and fixing in repair modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, controlled by one switch complete all as specified and directed.
5
-
-
... More
Supply and fixing modular fan regulator complete all as specified and directed.
4
-
-
... More
S & F in repair modular white cover plate with frame 2 module complete all as specified and directed.
4
-
-
... More
S & F in repair modular white cover plate with frame 3 module complete all as specified and directed.
4
-
-
... More
S & F in repair modular white cover plate with frame 6 module complete all as specified and directed.
4
-
-
... More
S & F in repair modular white cover plate with frame 8 module complete all as specified and directed.
4
-
-
... More
S&F in repair electric bell single phase suitable for 240 Vcomplete all as specified and directed.
3
-
-
... More
Supply & fixing in repair LED tube light complete fitting 1x18 watt 220V, AC decorative box type with driver , holder including LED tube light connecting up with three core flexible xopper conductor cable of suitable size from ceiling rose complete all as specified and directed.
20
-
-
... More
Supply & fixing in repair LED light fitting mirror type with high out put 2 feet , 10 watt 220 V AC connecting up with three core flexible coppder conductor cable of suitable sixe complete all as specified and directed.
5
-
-
... More
S & F in repair LED lamp 10 Watt B22 CDL complete all as specified and directed.
10
-
-
... More
Supply & fixing in repair LED light luminaire 600mmx600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible coppder conductor cases of suitable size complete all as specified and directed.
4
-
-
... More
Supply and fix in repair sheet metal enclosures with socket plug top and MCB's with two pin and earth plug and socket complete with one Single pole MCB 240 V grade 25/20/10 Amp complete all as specified and directed .
2
-
-
... More
S & F in repairs sheet metal enclosure double door type surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc including taking down old unsv DB complete all as specified and directed.
1
-
-
... More
Supply and fix in repair DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar with encosure blank plates for unused complete all as specified and directed.
1
-
-
... More
Supply and fix in repair DB, TP & N , 4 way double door for MCB, 415 volt with 200 amps rated bus bar with encosure blank plates for unused complete all as specified and directed.
1
-
-
... More
S & F in repairs MCB SP suitable for 240 volts, AC supply 6 to 32 Amps , with over load and short circuit protection and rupturing capacity not less than 10KA including taking down old unsv MCB SP complete all as specified and directed.
10
-
-
... More
S & F in repairs MCB SPN suitable for 240 volts, AC supply 6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA , including taking down old unsv MCB SPN complete all as specified and directed.
2
-
-
... More
S & F in repairs MCB SPN suitable for 240 volts, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA including taking down old unsv MCB SPN complete all as specified and directed.
2
-
-
... More
S & F in repairs MCB TPN suitable for 415 volts, AC supply, 40 to 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA including taking down old unsv MCB TPN complete all as specified and directed.
2
-
-
... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified and directed. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
20
-
-
... More
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified and directed. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 4 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
20
-
-
... More
S&F in replacement building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings complete all as specified and directed.
2
-
-
... More
S&F in repairs laminated hylum sheet cover of size 11 X 13 inches, ISI marked of Make" Hylem" including cutting grooves for mounting of fittings like switches, sockets, fan regulators etc; including fixing in location with new galvanised screws and cup washer complete all as specified and directed.
2
-
-
... More
S&F in repairs laminated hylum sheet cover of size 9 X 11 inches, ISI marked of Make" Hylem" including cutting grooves for mounting of fittings like switches, sockets, fan regulators etc; including fixing in location with new galvanised screws and cup washer complete all as specified and directed.
2
-
-
... More
S&F in repairs laminated hylum sheet cover of size 5 X 8 inches, ISI marked of Make" Hylem" including cutting grooves for mounting of fittings like switches, sockets, fan regulators etc; including fixing in location with new galvanised screws and cup washer complete all as specified and directed.
2
-
-
... More
S&F in repairs laminated hylum sheet cover of size 5 X 5 inches, ISI marked of Make" Hylem" including cutting grooves for mounting of fittings like switches, sockets, fan regulators etc; including fixing in location with new galvanised screws and cup washer complete all as specified and directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%