Military Engineer Services Tender
... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date19 Jun 2018
Closing Date9 Jul 2018
Tender Amount₹ 10,00,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Repair/Maintenance of cooling appliances at 28 ED AFS Amla
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MES_191881_1Bid Award Id
ViewTender No
8275/E8 of 2018-19Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking down split AC /Window AC from any position, any condition from existing location and deposit to MES store / work shop complete all as specified and directed by EIC
8
-
-
... More
Refixing split AC / Window AC to existing location/ any other location, any postion including gas charging and any addn / altn patch work and grouting cutting, brazing, complete all as specified and directed by EIC.
8
-
-
... More
Supply and fixing in repair Indoor Unit 1.5 TR for Split AC PC Bord, Cooling Coil,Wairless Remote, Drain Pipe. Make:- Hitachi, LG, Voltas and BlueStar
2
-
-
... More
Supply and fixing in repair Indoor Unit 2 TR for Split AC PC Bord, Cooling Coil,Wairless Remote, Drain Pipe. Make:- Hitachi, LG, Voltas and BlueStar
2
-
-
... More
Starting Capacitor 100 / 120 MFD 275 Volts 50 Hz
12
-
-
... More
Starting capacitor 80 / 100 MFD 275 Volts 50 Hz
6
-
-
... More
Running capacitor 45 MFD 440 Volts, 50 Hz.
6
-
-
... More
Running capacitor 36 MFD 440 Volts, 50 Hz.
6
-
-
... More
Dual Capacitor Starting & running 45 / 50 MFD capacity 25 / 085 / 21 MPP SH Make : EPCOS
12
-
-
... More
Capacitor for Condensing Fan Motor 4 MFD
6
-
-
... More
Capacitor for Condensing Fan Motor 6 MFD
4
-
-
... More
Starting Relay 4 / 5 pin suitable for AC's 1.5 ton to 2.0 ton capacity.
9
-
-
... More
On / Off Knob 3 / 4 way
2
-
-
... More
Thermostat for Split / Window AC
100
-
-
... More
Filter Drier 1/4" x 1/4"
2
-
-
... More
PCB along with control relay and suitable for split window type AC's (as per sample)
8
-
-
... More
Rotary Compressor Sealed Unit for split Air Conditioner of capacity 2.0 TR Make :- KIRLOSKAR/LG
4
-
-
... More
Compressor Sealed Unit for window / split Air Conditioner of capacity 2.0 TR Make :- KIRLOSKAR / LG
4
-
-
... More
Compressor Sealed Unit for window / split Air Conditioner of capacity 1.5 TR
Make :- KIRLOSKAR / LG Note for item 7.13, 7.14 & 7.15 :- In case of any defect in compressor contractor will replace compressor without any financial effect Up to One year
6
-
-
... More
M & L for suitable/existing Refrigerant/gas filling (including gas charges )and testing in the window model/Split type AC including testing the system for 8 hours each in pressure not less than 10 Kg/Sqcm and vacuum complete all as specified and directed by Engr-in- Charge. Note:- Contractor has to refill the gas without any addtional payment incase of any leakage/ shortage of gas/shortage of cooling effect.
20
-
-
... More
PVC Insulated Copper flexible cable 3 core 4 Sqmm 1100 Volts Grade ISI Marked
50
-
-
... More
3- way Bakelite connector of capacity 20 Amps
2
-
-
... More
S&F Fan Motor suitable for Window AC 1.5/2 TR
10
-
-
... More
S&F Fan Motor suitable for outdoor unit of Split AC 1.5/2 TR
10
-
-
... More
Supply and fix in repairs Copper tubing (Refrigerant pipe) of different sizes from 1/4'' to 5/8" and connecting complete including bending in required shape forming etc.
15
-
-
... More
M & L for insulation of refrigerant pipe line both discharge & suction with 3 mm thick thermo form black colour sheet including binding and rapping with insulation tape complete all as directed by EIC.
50
-
-
... More
Supply and fix in repairs dead nuts size 1/4 " complete all as specified and directed by Engr-in- Charge.
6
-
-
... More
Supply and fix in repairs flair nuts size 1/4 " complete all as specified and directed by Engr-in- Charge.
6
-
-
... More
Servicing/preventive maintenance/repairs of water cooler of cooling capacity upto 40 to 150 Ltrs / Hr and storage capacity upto 150 Ltrs complete with disconnecting the water connection, inserting dead plug, dismantling the fan motor, taps, fan blades, condenser etc.Checking up and rectification to wiring and connections, replacement of necessary parts and accessories, and testing complete all as specified and directed. Make of Water cooler : Voltas, Shriram Usha, Sidwal, Bluestar NOTE :- Cost of spare parts replaced during the process of repair shall be measured and paid separately under relevant item herein after.
36
-
-
... More
Thermostat switch with knob
Make :- INDFOSS
7
-
-
... More
Push tap inner thread chromimum plated D type of size 15 mm dia.
5
-
-
... More
Push tap outer thread chromimum plated D type of size 15 mm dia.
4
-
-
... More
PVC flexible drain water pipe of bore 32 mm suitable for water cooler drain water.
5
-
-
... More
PVC connections 15mm size with PTMT nuts of length 450mm
3
-
-
... More
Condenser fan motor 230 Volts, AC 50 Hz 1/35 Watt
10
-
-
... More
Capacitor 10 Mfd
2
-
-
... More
Capacitor 6 Mfd
4
-
-
... More
Capacitor 4 Mfd Make for item Nos 13.07 to 13.09 :- KELTRON / INCAP/TIPCON / EPCOS
2
-
-
... More
Relay for water cooler
8
-
-
... More
Steel drain water tray suitable for water cooler size 40/60 ltr capacity
2
-
-
... More
Flexible cord with moulded plug 16 Amps of size 3 Core 2.5 Sqmm 3 mtr length stranded copper conductor ISI Marked
1
-
-
... More
Compressor Sealed unit for water cooler capacity 40 / 80 Ltrs. Make : Usha/ Shriram / Kirloskar / LG
4
-
-
... More
Compressor Sealed unit for water cooler capacity 60 / 120 Ltrs Make : Usha / Shriram / Kirloskar / LG
3
-
-
... More
Compressor Sealed unit for water cooler capacity 120 / 150 Ltrs.
Make : Usha/Shriram / Kirloskar/LG Note for item 13.13, 13.14 & 13.15:- In case of any defect in compressor contractor will replace compressor without any financial effect Up to One year
1
-
-
... More
M & L for suitable/existing Refrigerant / gas filling (including gas charges) in the water cooler capacity 40/80, 60 / 120, 120/150 Ltrs including testing the system for running smooth functioning Note:- One year guarantee certificate by Contractor be given on site gas re-filling in case of any complaint by user against shortage of Gas filling.
8
-
-
... More
M & L for cleaning of the cold water tank with bleaching powder and including writing date of cleaning and due date for cleaning, white paint on black back ground, piping,flushing refrigerant lines, realignment of the fan coil unit and replacement of drain pipe , connecting to water mains and testing complete all as specified and directed. Contractor duly signed by user with Signature, No, Rank, Name and duly checked by Engr- In-Charge complete all as specified and directed. Note:- Register maintained by the contractor daily signed by the user with signature No, Rank, Name and checked by the Engr-In-Charge completed in all as specified and directed.
36
-
-
... More
M&L for half yearly maint / cleaning, servicing and re fixing of new fiter assembly testing and marking due date on water filter of aqua guard /any other (Aqua Plus)/ Kent including all UV, RO, UF+, spare parts for suitable functioning crystal including connecting pipes, accessories, carbon filters and UV lamps installed in office complex / cook houses and various location complete all as specified and directed.
2
-
-
... More
Servicing/preventive maint/repairs of refrigerator of any capacity Checking up and rectification to wiring and connections, refilling of refrigerent, replacement of necessary parts and accessories, cleaning of refrigerator inner and outer side, replacement of piping, refixing & re alignment of the parts, connecting up and testing complete all as specified and directed .
Note :- (i) Spare parts replaced during the process of repair / overhaul shall be measured and paid separately under relevant item herein after)
28
-
-
... More
Servicing/preventive maint/repairs of Deep Freezer of any capacity Checking up and rectification to wiring and connections, refilling of refrigerent, replacement of necessary parts and accessories, cleaning of inner and outer side, replacement of piping, refixing & reallignment of the parts, connecting up and testing complete all as specified and directed Note :- (i) Spare parts replaced during the process of repair / overhaul shall be measured and paid separately under relevant item herein after). (ii) Register meaintained by contractor duly signed by user with Signature, No, Rank, Name and submitted to Engr- In-Charge complete all as specified and directed.
2
-
-
... More
Thermostat Switch Defrost Type with Knob
1
-
-
... More
Relay for Refrigerator
5
-
-
... More
PVC Refrigerator stand
1
-
-
... More
Compressor sealed unit 1/6 HP sealed unit for Refrigerator Make :- Videocon/ LG/Kirloskar/Godrej
2
-
-
... More
Compressor sealed unit1/8 HP sealed unit for Refrigerator Make :- Videocon/ LG/Kirloskar/Godrej (Note for 19.4 & 19.5:- In case of any defect in compressor contractor will replace compressor without any financial effect Up to One year)
2
-
-
... More
Filter Drier
1
-
-
... More
Flexible cord with moulded plug 5 Amps of size 3 core 2.5 Sqmm PVC insulated copper 3 Mtr length with ISI Marked.
5
-
-
... More
M & L for suitable/existing Refrigerant/gas filling (including gas charges ) and testing in the Refrigerator / Deep freezer including testing the system for 8 hours each in pressure not less than 10 Kg/Sqcm and vacuum.
5
-
-
... More
Servicing/preventive maint/repairs of desert cooler complete of capacitiy upto 3000/4000 CFM dismantling the fan, motor, pumps etc.Checking up and rectification to wiring and connections, replacement of necessary parts and accessories, cleaning of the water tank, replacement of piping, khas pads, refixing & realignment of the fan, complete, connecting up and testing complete all as specified and directed .
Note :- (i) Spare parts replaced during the process of repair / overhaul shall be measured and paid separately under relevant item herein after) (ii) Register maintained by contractor duly signed by user with Signature, No, Rank, Name and submitted to Engr- In-Charge complete all as specified and directed.
131
-
-
... More
Khas pad for desert cooler 2.5' x 2'
30
-
-
... More
Khas Pad of size 2' x 3'
25
-
-
... More
Khas pad of size 1.5' x 3'
30
-
-
... More
Desert Cooler Fan motor 1/6 HP exhaust type, 1400 RPM, ISI marked
30
-
-
... More
Desert Cooler Body size: 3 Ft width, 4 Ft height including Fan motor & pump On/Off Switch, 3 mtr, 2.5 sq mm wire, 5/6 amp plug top. All items ISI Mark MES AS per Sample, Engr- In-Charge complete all as specified and directed.
15
-
-
... More
Desert Cooler Body size: 2 Ft width, 3 Ft height including Fan motor & pump On/Off Switch, 3 mtr, 2.5 sq mm wire, 5/6 amp plug top. All items ISI Mark MES AS per Sample, Engr- In-Charge complete all as specified and directed.
10
-
-
... More
Desert Cooler Fan & motor bracket
15
-
-
... More
Four wing fan blade
20
-
-
... More
Pump 35 watts 6 feet head for desert cooler.
ISI marked
36
-
-
... More
Two Way piano switch 6 Amp
Make :- Anchor/Leader or equivalent
15
-
-
... More
Rotary Knob
5
-
-
... More
Flexible cord with moulded plug 5 Amps of size 3 Core 1.5 Sqmm, 3 Mtr Length PVC insulated copper with ISI Marked.
30
-
-
... More
Capacitor 4/3.15 mfd for Desert cooler
40
-
-
... More
M & L for gas welding/brazing of capillary connections in the refrigerant circuit using copper rod for refrigerator / watercooler/ window type AC / Split AC / Deep Freezer complete all as directd by EIC at site. (Copper Tubing Required will be measured and paid separately under relevant item)
26
-
-
... More
S & F in repairs ball cast iron valves, high pressure with Polyethylene float and flynut complete screwed for iron pipe on or brass ferrule and fixed of size 15 mm dia complete all as specified and directed by Engr-in- Charge. ISI marked as approved by the GE
5
-
-
... More
Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete all as specified and directed by Engr-in- Charge.
Make :- Legrand or equivalent
10
-
-
... More
S & F in repairs MCB SP of Capacity upto 32 Amps 240 Volts complete all as specified and directed by Engr-in- Charge.
Make :- Legrand or equivalent
10
-
-
... More
Supply and lay galvanised pipe medium grade of bore 20mm (including bends, tees, nipple, socket, reducer) complete all as specified and directed by Engr-in- Charge.
12
-
-
... More
S & F Stop cock 20 mm dia bore fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of for union and fixed complete all as specified and directed by Engr-in- Charge.
Make :- Leader, Hindustan Metal Industries, Zoloto
2
-
-
... More
Supply and lay galvanised pipe medium grade of bore 15mm (including bends, tees, nipple, socket, reducer) complete all as specified and directed by Engr-in- Charge.
Make : Jindal, Tata, Swastik
12
-
-
... More
S & F Stop cock 15 mm dia bore fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of for union and fixed complete all as specified and directed by Engr-in- Charge.
Make :- Leader, Hindustan Metal Industries, Zoloto
2
-
-
... More
Construction of rising platform for water cooler of size 800mmx800mmx250mm with brick work 200mm height in CM (1:4), top covered with 50mm thick PCC (1:2:4) along with cement mortar border (1:3) of size 75mmx50mm around platform top and complete plastering 15mm thick in CM (1:4) finished even and smooth using extra cement complete all as directed.
6
-
-
... More
S & F PVC pipe of 40mm dia including all bends necessary clamps for fixing on walls and floors complete all as specified and directed by Engr-in- Charge.
20
-
-
... More
Supply only PVC Insulated Copper flexible cable 3 Core of size 0.5 Sqmm 1100 Volts grade to be incorporated in repairs to ceiling / exhaust fan
75
-
-
... More
Flexible PVC pipe connections 15 mm dia with brass nuts of length 450 mm suitable for hot Water
25
-
-
... More
M & L for servicing of air blast type electrically operated chimmey installed in cook houses by dismantling complete filter assemblies/ducts and connected items for descaling with suitable chemical solution/costic soda including reassembling and testing complete all as specified and directed.
4
-
-
... More
M &L for dismantling unserviceable blower motor 3 phase 415 volts 1400 RPM 3 HP from existing pillor and trasporting to civil work shop for repair/rewinding and reassembling the same on foundation and testing by the followings:- (i) Opening/dismantling electric motor and removing burnt copper winding from starter and cleaning. (ii) M&L for rewinding stater with suitable gauge of super enameled copper winding wire including fixing of insulating papers, varnishing complete. (iii) Replacement of ball bearing to match existing Nos 2 (Make:NBC/ SKF)
3
-
-
... More
Split AC outdoor bracket
10
-
-
... More
R-22
122
-
-
... More
R-134A
30
-
-
... More
R-407
50
-
-
... More
S & F 3 pin plug top 5 AMP