Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Oct 2024
Closing Date30 Oct 2024
Tender Amount₹ 45,54,000
Costs
EMD
₹ 91,080Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677876_1Bid Award Id
ViewTender No
8799/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking down cement plaster on brick/stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
1465
-
-
M&L for 15mm thick rendering on fair faces of brick work or concrete surface of wall in CM 1:4 with WPC and to be finished even and smooth without using extra cement complete all as specified and as directed. (Note: WPC compound shall be measured and paid separately)
2505
-
-
M&L for applying two coats of cement based paint over a coat of alkali resistant primer on new plastered surfaces of wall and including preparation complete all as specified and as directed.
1535
-
-
M&L for applying two coats of cement based paint on old decorated surfaces of wall incl preparation of surfaces complete all as specified and as directed.
400
-
-
M&L for applying two coats of exterior emulsion paint over a coat of primer on new plastered surfaces of wall including preparation complete all as specified and as directed.
40
-
-
Complete removal of existing surface and applying two coats exterior emulsion paint over a coat of Primer on old decorated surfaces incl preparation complete all as specified and as directed.
40
-
-
M&L for Plain cement concrete (1:4:8), type D-2, using 40mm graded crushed stone aggregate as in foundations filling and mass concrete complete all as specified and as directed.
7
-
-
M&L for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
4632.7
-
-
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer on new or previously untreated steel and iron surfaces of any description over 10cm in width or girth including Preparation complete all as specified and as directed.
192
-
-
M&L for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
550
-
-
S & F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed.
(Note: each line of wire to be measured)
47.8
-
-
M&L for Concertina coil fencing with Punched tape Concertina coil 800 mm dia confirming to IS:4454 and having 10 m openable length (total length 90m) having 50 No's rounds per 6m lenth, spring core wire(2.5 mm thick) of high tensile strength of 165kg/sq.mm with tape (0.52 mm thick) and and weight 43.478 gm per metre and fixing the same including provision of necessary GI 'U' clips fixed in position over boundary wall to angle iron posts/horns complete all as specified and as directed .
556
-
-
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering including ridge complete all as specified and as directed.
60
-
-
Demolition of brick work built in cement mortar of any description including all quions, arches, pillars, etc complete and removing rubbish from the premises all as specified and as directed.
44.56
-
-
Demolition of RCC jali in any description in any position complete all as specified and as directed.
4.8
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
3
-
-
S&F for Framed work as in doors or gates of angle/ MS tube or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming Fe-410W(GdeE-250) quality B complete all as specified and as directed.
700
-
-
M&L for 18-20mm thick black granite stone slab machine cut in skirting/dado, cooking platform, jams, pillars, windows cills and the like laid over and including 10mm thick screed bed or backing coat in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
20
-
-
M&L for RCC 1:2:4 type B1 using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed
2.5
-
-
M&L for RCC 1:2:4 type B1 using 20mm graded stone aggregate as in Foundations, footings,mass concrete complete all as specified and as directed
2.25
-
-
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed
10
-
-
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed
6
-
-
M&L for TMT reinforcement bars 10mm and over dia including all cutting bending binding cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and as directed
380
-
-
M&L for TMT reinforcement bars 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders complete all as specified and as directed .
120
-
-
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
575
-
-
S&F for Refixing of old pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet obtained from item above as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
30
-
-
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, wind ties etc. conforming Fe 410 -W (GdeE- 250) qualityA complete all as specified and as directed.
600
-
-
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in copings, kerbs, and the like all as directed incl necessary form work complete all as specified and as directed.
14.79
-
-
M&L for 40-50 mm thick ready made precast cement concrete louvered and jali of approved design set in cm 1:4 including all mouldings all as specified and as directed.
87
-
-
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed.
35.5
-
-
M & L for preparation of new plastered wall surface and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over 2mm thick water proof wall care putty complete all as specified and as as directed.
1070
-
-
M&L for Complete removal of existing treatment of any description and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over and including 2mm thick water proof wall care putty complete all as specified and as directed.
272
-
-
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation and filling mass concrete etc complete all as specified and as directed. .
9.8
-
-
Excavating in post holes (or similar holes) each n.exc 0.5 cu.m getting out, returning filling in and ramming earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface in soft and loose soil complete all as specified and as directed. .
32
-
-
M&L for Precast factory made reinforced cement concrete 1:2:4 type B-l, (using 20 mm graded stone aggregate) as in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional are exc 100 sq. cm not exc 250 Sq cm, with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and as directed.
1.56
-
-
M & L for 40-50 mm thick precast cement concrete solid building blocks or slabs (with plain or interlocking joints as directed) setting RCC post in cement mortar, complete all as specified and as directed.
144
-
-
S&F in repair for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
4
-
-
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft /loose soil complete all as specified and as directed.
552
-
-
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
75.5
-
-
M&L for 100 mm thick Cement concrete 1:4:8 type D-2, , using 40 mm graded stone aggregate as in sub base 1:4:8 1:4:8 complete all as specified and as directed.
552
-
-
M&L for Machine pressed coloured precast concrete interlocking paver block any shape and size ( with grey cement and pigment) confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and as directed.
290
-
-
M & L for Factory made precast cement concrete blocks made of 1:2:4 type B-1, using 20mm graded stone agg as in kerb stone chamfered fixed in CM 1:6 complete all as specified and as directed.
6.19
-
-
M&L for 50 mm thick Sand filling below the interlocking paver block including watering and consolidation complete all as specified and as directed.
16
-
-
Excavation in trenches in soft/loose soil n. exc 1.50 metre wide and n. exc 1.50 metre deep for foundation and n. exc 10 Sqm on plan area and getting out complete, all as specified and as directed..
10
-
-
Returning filling in, including, spreading, leveling watering and well ramming in layers n exc 25 cm thick each, complete all as specified and as directed.
5
-
-
Supply, laying and jointing 150mm nominal bore dia DWC ( HDPE double wall corrugated), socketed and sewage pipes having 6.0 mtr length, conforming to IS-16098 (Part-2) of SN-4 stiffness with and includung necessary jointing materials etc complete all as specified and as directed.
20
-
-
Supply, laying and jointing 200mm nominal bore dia DWC ( HDPE double wall corrugated), socketed and sewage pipes having 6.0 mtr length, conforming to IS-16098 (Part-2) of SN-4 stiffness with and includung necessary jointing materials etc complete all as specified and as directed.
35
-
-
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and as directed.
20
-
-
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 200 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and as directed.
35
-
-
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches , in floors or walls of 110 mm bore of pipe etc complete all as specified and as directed.
40
-
-
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches , in floors or walls of 75 mm bore of pipe etc complete all as specified and as directed
10
-
-
S&F for PVC (SWR) bends ISI marked of 110 mm bore with access door complete all as specified and as directed.
4
-
-
S&F for PVC (SWR) bends ISI marked of 75 mm bore with access door complete all as specified and as directed.
4
-
-
S&F for PVC (SWR) junction single, (single T) equal or un equal of 75 mm bore of pipe complete all as specified and as directed
5
-
-
S&F for PVC (SWR) junction single, (double T) equal or un equal of 110 mm bore of pipe complete all as specified and directed
6
-
-
S&F for PVC (SWR) vent cowl of 110 mm bore of pipe complete all as specified and as directed
4
-
-
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and as directed.
3
-
-
Supply only Integral water proofing compound complete all as specified and directed.
4
-
-
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and as directed.
20
-
-
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
35.2
-
-
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors including 15 mm thick screed bed in CM 1:6 for laying floor finish complete all as specified and all as direcred.
232
-
-
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates complete all as specified and as directed.
465
-
-
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding/ ridge to wall, fixed with self tapping screws complete all as specified and as directed.
5
-
-
M&L for 25 mm thick PCC (1:2:4), type B-0, using 12.5 mm graded aggregate as in subbabse or to receive rough finish as in floor complete all as specified and as directed.
90
-
-
M&L for non skid ceramic coloured joint free tiles 10 mm thick area of each tile exceedeing 0.18 sqm but n.exc 0.38 sqm (600x600), in floors, set and jointed in neat cement slurry and pointed in white cement to over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed.
90
-
-
S&F in repairs 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed.
22
-
-
M&L for Machine pressed coloured precast concrete rubbber moulded interlocking paver blocks of any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and as directed.
30
-
-
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed. : .
2.5
-
-
M&L for Mild Steel TMT bar 8 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
200
-
-
M&L for Formwork to Soffiting of Suspended slab such as roof slab,floor slabs landing and similar work not exceeding 200 mm thickness complete all as specified and as directed
14
-
-
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors for 20mm bore of pipe including Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor and all necessary fittings etc complete all as specified and as directed.
10
-
-
M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate, as in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and as directed.
30
-
-