Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Jun 2024
Closing Date22 Jul 2024
Tender Amount₹ 49,00,000
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/maintenance Of Dg Sets, Amf Panels , Control Panels, Voltage Stabilizers, Isolation Transformers, Air Compressors And Connected Work Of Different Capacity And Periodical Cleaning And Maint Servicees To Overhead Reservoirs, Valve Chambers In
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_662782_1Bid Award Id
ViewTender No
8900/1555/GWL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
All as per Item No . 1 here-in -before but for : 250 KVA DG set
Make:- Sterlin,Kirloskar with AMF panel
2
-
-
... More
All as per Item No . 1 here-in -before but for : 200 KVA DG set
Make:- `Kirloskar with AMF panel
1
-
-
... More
All as per Item No . 1 here-in -before but for : 160 KVA DG set
Make:- Kirloskar/Cummins with AMF panel
2
-
-
... More
All as per Item No . 1 here-in -before but for : 125 KVA DG set
Make:- Cummins with AMF panel
3
-
-
... More
All as per Item No . 1 here-in -before but for : 100 KVA DG set
Make:- KirloskarMahindra with AMF panel
2
-
-
... More
All as per Item No . 1 here-in -before but for : 63 KVA DG set
Make:- Kirloskar with AMF panel
1
-
-
... More
All as per Item No . 1 here-in -before but for : 40 KVA DG set
Make:- Kirloskar with AMF panel
2
-
-
... More
All as per Item No . 1 here-in -before but for : 20 KVA DG set
Make:- `Kirloskar/Cummins with AMF panel
2
-
-
... More
All as per Item No . 1 here-in -before but for : 18.75/15/7.5 KVA DG set Make:- `Crompton greaves/Koel/Cummins with AMF panel Note for BOQ Item No 1.00 to 12.00
1. Engine oil for refilling will be measured and paid Seprately 2. Coolant for make up will be measured & paid separately
3. DHPP will be issued by dept for testing and top up in tank only. 4. The Make of Fuel filter , Oil Filter , V belt & component will be as per existing or suitable make. 5.Spray painting of DG set as per existing colour including preparation of old surfaces all as directed by Engineer -in -Charge . 6. The rate quoted against item No. 1.00 to 12.00 is deemed to be inclusive of any break down attendance / rectification during contract period with in 72 hours of complaint received. failing which penalty @ 3000.00 per day will be recovered from work done statement till rectification .
7. A register for record of servicing & break down attendance shall be maintained by contract duly signed by JE /Engineer-in -Charge .
8. Cost of spares & labour charges for attending break down shall be paid under relevant item of this schedule here in after.
3
-
-
... More
Supply only Air filter element kit as per existing make for DG sets of 40/63 KVA capacity NOTE:- The contractor to be purchased all items from manufacturerer's / manufacturers authorised stockiest/ distributor/ dealer only and also the contractor always keep minimum required quantities in hand as a pro-active/ preventive maint/ breakdown measure against BOQ items as applicable
3
-
-
... More
Supply only Engine oil SAE 20W-40W, Make :- VOLVOLINE/ IOC/HP
795
-
-
... More
Supply only fan belt V-Belt of size B-53 complete all as specified Make : Fenner/Cummins/Kirloskar/Dunlop
2
-
-
... More
All as per item No 15 above but of size B-56
10
-
-
... More
All as per item No 15 above but of size B-58
8
-
-
... More
All as per item No 15 above but of size B-64
6
-
-
... More
All as per item No 15 above but of size B-70
4
-
-
... More
All as per item No 15 above but of size B-143
8
-
-
... More
All as per item No 15 above but of size B-180
6
-
-
... More
Supply only coolant for radiator all as specified and directed. Make :- TVS/HP/Castrol
385
-
-
... More
M & L for spray painting the Generator Set including acoustic enclosure and corresponding AMF panel complete with existing colour coding of any capacity after preparation of rough unequal surface and applying two coats of synthetic enamel paint over coat of primer on old steel surface by spray painting in and including lettering and marking i.e Engine make, Engine Sl No, Alternator make, Alternator Sl No etc all as specified and directed.
8
-
-
... More
Supply & Fix in repair of ON LOAD change over switch , 4 pole , 200 Amps, in open execution / Panel mounting, front operated complete all as specified and directed .
2
-
-
... More
S & Fix in repair/replacement of Automatic voltage regulator (AVR) full wave phase controlled adjustable (0-95V) 6A/12A Suitable for DG Set 40 to 200 KVA including connecting and testing complete all as specified and directed.
12
-
-
... More
Supply and fix in replacement of Lead acid battery, 24 volt, 180 AH Confirming to IS 14257-1995 complete all as specified and directed. Make :- Exide/ Amco/Amaron
9
-
-
... More
Supply and fix in replacement of Lead acid battery, 12 volt, 150 AH Confirming to IS 14257-1995 complete all as specified and directed. Make :- Exide/ Amco/Amaron
8
-
-
... More
M & L Repair / overhauling radiator assembly of DG set by disconnecting and removing from the engine, dismantling the top and bottom chambers, descaling the sediments, scales, corrosion etc. by means of acid, cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets including arresting leakages, if any and fixing to the engine with new hoses, clips etc of 500/320 KVA DG Set all as required and as directed.
Note: The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges.
4
-
-
... More
M & L Repair / overhauling Self starter assembly, 12/24 Volt DC of DG Make: Delco Remi / Lucas TVS assembly of DG Set by disconnecting and removing from the engine, cleaning of all accessories, replacing of worn out parts such as actuator ,gear, solenoid coil ,carbon brushes, bushes, contact plates, jumping leads and seals, revarnishing the field coil, armature and re-assembling the same and re-fixing into the engine including testing all as per original manufacturer's instructions, complete all as specified and directed. . NOTE :- 1. The rate quoted by the contractor is deemed to be include for transportation of the item from site to the workshop as applicable and back.
5
-
-
... More
Supply and fix in repair fuel shutup solenoid valve, 12/24 volts, suitable for 500/320 KVA DG set complete all as specified and directed. NOTE:- All items to be from manufacturerer's / manufacturers authorised stockiest/ distributor/ dealer only and also the contractor always keep minimum required quantities in hand as a pro-active/ preventive maint/ breakdown.
5
-
-
... More
Supply and fix in repair fuel shutup solenoid valve, 12/24 volts, suitable for 160/250 KVA DG set complete all as specified and directed. NOTE:- All items to be from manufacturerer's / manufacturers authorised stockiest/ distributor/ dealer only and also the contractor always keep minimum required quantities in hand as a pro-active/ preventive maint/ breakdown.
5
-
-
... More
S & Fix in replacement of SMPS based Battery charger module 24/12 volt 15/20A Amps having CC,CV, trickle,float and boost charging mode suitable for AMF Panels of DG Set 100/125/200/250/320/500 KVA capacity complete all as specified and directed.
6
-
-
... More
S & Fixing in repairs Lub oil pressure transducer suitable for DG set upto 500 KVA system complete all as specified and directed.
7
-
-
... More
S & Fixing in replacement of proximity Magnetic pickup for sensing RPM of DG set 250/380 KVA capacity with existing model complete all as specified and directed.
5
-
-
... More
S & Fixing in replacement of Low lub oil pressure safety switch suitable for DG set 160/250KVA and connecting with DG set system, testing complete all as specified and directed.
8
-
-
... More
S & Fixing in repairs High water temperature trip safety switch suitable for DG set 320/500KVA and connecting with DG set system, testing complete all as specified and directed.
5
-
-
... More
M & L for repair/overhauling battery charge Dynamo by dismantling from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete 200/500 KVA DG set complete all as specified and directed.
4
-
-
... More
S & Fixing in replacement of wiring harness for 100/160/200/250/320 KVA DG set with proper lugs /ferrules/nuts bolt with washers and testing the circuit complete all as specified and directed.
8
-
-
... More
S & F following items in AMF Panel of any description and in any position of capacity DG Set upto 500 KVA including checking AC/DC circuits, tightning of all power / control wiring connection and replacement of unserviceable control wiring with suitable size, single core, copper conductor, flexible, PVC insulated, unsheathed cable suitable upto 1100 volts confirming to IS-694, taking out, removing and replacement of unserviceable parts / spares / items to make AMF functional inclusing testing complete all as specified and directed.
-
-
-
... More
Pla relay 24 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -24D of pla make or equivalent of Eagle man complete all as specified and directed.
15
-
-
... More
Pla relay 12 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -12D of pla make or equivalent of Eagle man complete all as specified and directed.
18
-
-
... More
Ammeter size 96 mm X 96mm, flush mounted digital type, three phase of class 1.0 complete all as specified and directed.
Make: HPL / Rishab / MECO / Schneider.
8
-
-
... More
Voltmeter size 96 mm X 96mm, flush mounted digital type, three phase, class 1.0 complete all as specified and directed.
Make: HPL / Rishab / MECO / Schneider.
7
-
-
... More
Frequency meter size 96 mm X 96mm, flush mounted digital type, three phase, class 0.2 complete all as specified and directed.
Make: HPL /Rishab / MECO / Schneider.
7
-
-
... More
Under voltage relay suitable for 3 phase 415 volts, AC supply complete all as specified and directed.
Make: PIC / Aditya Electronic/L&T
14
-
-
... More
Engine starting relay with sequence timer & master timer suitable for 12 / 24 Volts DC supply complete all as specified and directed.
Make: PIC / Aditya Electronic/L&T
16
-
-
... More
Electronic timer, time range from 3 seconds to 10 seconds , suitable of 12/ 24 Volts, 50 Hz, AC supply complete all as specified and directed.
Make : L&T / PIC / Aditya Electronic.
10
-
-
... More
Rectifier 4 plates, single phase, having charging rate 15–20 Amp per minute for 12/24 Volts DC battery charge complete all as specified and directed. Make : Usha / URI / Kirloskar.
8
-
-
... More
Rectifier 8 plates, single phase, having charging rate 15–20 Amp per minute for 12/24 Volts DC battery charge complete all as specified and directed. Make : Usha / URI / Kirloskar.
8
-
-
... More
LED Indicator 22.5mm for 12 /24 volts AC/DC supply complete all as specified and directed.
Make: L&T/ BCH / Seimens / ABB.
26
-
-
... More
Battery charging transformer 0 to 10 Amperes, 12 Volts DC tapping 0-12-18-24 Volts complete all as specified and directed.
4
-
-
... More
MCB single pole, 10 KA, rating 6 to 32 Amps ‘C’ series, 240 volts complete all as specified and directed.
12
-
-
... More
M&L for repairing of canopy of DG set by carrying out repairing of door with replacement of broken hinges including nuts, bolts/welding etc as per requirement, cleaning of base of foundation and painting with black paint MS channel with two coats including touching of paint at canopy where required complete all as specified and directed
4
-
-
... More
Material and labour for dismantling and taking out and rewinding of Alternator starter assembly of 320 to 500 KVA DG Set and rewinding of approved suitable gauge super enamel insulated copper winding wire with necessary insulating materials reassembling and transportation to workshop and bring back to orgins at installation and fixing, testing and commissioning complete all as specified and directed.
3
-
-
... More
All as per item No 41 above but of Capacity 250/200 KVA DG set.
2
-
-
... More
All as per item No 41 above but of Capacity 100/125 KVA DG set.
2
-
-
... More
All as per item No 41 above but of Capacity 40/63 KVA DG set.
3
-
-
... More
All as per item No 41 above but of Capacity 20/18.75/15/7.5 KVA DG set.
2
-
-
... More
S & F in repair governor control unit for electronic governor suitable for DG Sets of capacity upto 125 KVA complete all as specified and directed. Make: Kirlosker / Cummins/ABB
3
-
-
... More
S & F in repair governor control unit for electronic governor suitable for DG Sets of capacity 200 to 250 KVA complete all as specified and directed. Make: Kirlosker / Cummins/ABB
3
-
-
... More
S & F in repair governor control unit for electronic governor suitable for DG Sets of capacity 320 KVA to 500 KVA complete all as specified and directed. Make :Kirlosker / Cummins/ABB
4
-
-
... More
S&F in repair Actuator ETR fuel control unit of cummins/Kirloskar make DG sets of 320-500 KVA capacity complete all as specified and directed.
2
-
-
... More
S&F in replacement engine electronic (instrumentation) digital panel comprising of starting switch ON/OFF water temp display, hour meter cum RPM display, lubricant oil pressure display, lubricant oil temperature display, battery charing display, safety alarm against high water temp and lubricant oil pressure for cummins/Kirloskar make DG Set of 200-250KVA capacity complete all as specified and directed.
2
-
-
... More
M&L in replacement of AMF Power contactor , 4 pole, 415 Volts, 600 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
1
-
-
... More
M&L in replacement of AMF Power contactor , 4 pole, 415 Volts, 400 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
3
-
-
... More
M&L in replacement of AMF Power contactor , 4 pole, 415 Volts, 320 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
4
-
-
... More
M&L in replacement of AMF Power contactor , 4 pole, 415 Volts, 250 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
2
-
-
... More
M&L in replacement of AMF Power contactor , 4 pole, 415 Volts, 100 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
4
-
-
... More
M&L in replacment of AMF Power contactor , 4 pole, 415 Volts, 63 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
2
-
-
... More
S & F in replacement of Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,(0-600A) Current, P.F,frequency on existing AMF panel including necessary P.T & C.T's with all connected acccessories all as specified and directed. Make : Selec/AE/Meco/L&T
4
-
-
... More
S & F in replacement of push button switch with NO/NC contacts 415 V ,6A , with add on Aux Contacts and connected acccessories all as specified and directed.
Make : L&T/Siemens/ABB
12
-
-
... More
S & Fix in replacement of Rotatory selector switch 3/4 way 10A for Panel meter including connection as all as specified.
Make :L&T/Siemens/ABB
13
-
-
... More
M&L in replacement of MCCB, 3 poles 415 Volts, 100 Amps, 16 kA, 50 Hz, AC, adjustable type in the existing AMF panel board/sheet metal enclosure including any modification to existing panel frame size and fixing new MCCB with connecting bars to the main busbar and connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed.
5
-
-
... More
All as per item No 63 here in before but MCCB 3 pole, 125 Amps, breaking capacity Icu = 16 KA.
2
-
-
... More
All as per item No 63 here in before but MCCB, 4 pole, 160 Amps, breaking capacity Icu = 36 KA.
3
-
-
... More
All as per item No 63 here in before but MCCB, 4 pole, 200 Amps, breaking capacity Icu = 36 KA
5
-
-
... More
All as per item No 63 here in before but MCCB, 4 pole, 250 Amp, breaking capacity Icu = 36 KA
4
-
-
... More
All as per item No 63 here in before but MCCB, 4 pole, 350 Amp, breaking capacity Icu = 36 KA
3
-
-
... More
All as per item No 63 here in before but MCCB, 4 pole, 400 Amps, breaking capacity Icu =36 KA
2
-
-
... More
All as per item No 63 here in before but MCCB, 4 pole, 630 Amps, breaking capacity Icu = 50 KA
2
-
-
... More
Supply and fix PVC insulated multistranded copper cable suitable for DG sets battery of size 25 Sqmm complete all as specified and directed. .
53
-
-
... More
Supply and fix in replacement of gunmetal battery connecting terminal suitable for 12v/24v battery complete all as specified and directed. . Make :- Exide/amaron/Amco or eqivalent
25
-
-
... More
supply only spray can 500ml for cleaning electrical contacts and decarbonizing electrical parts complete all as specified and directed. . Make : CRC/WD-40/3M
15
-
-
... More
M & L in replacement of flywheel with gear tooth assembly and align center/level between alternator and engine and testing complete all as specified and directed. . Make : Kirloskar/Cummins or Equivalent
6
-
-
... More
S&F DG Set specification board made out of flexible acrylic sheet of Size 2 x 3 feet background of blue colour with white letters of size 50/40mm for alongwith all fixing arrangements different type and model of DG Set as per sample and including removing old existing damaged board complete all as specified and directed. .
4
-
-
... More
S & Fix in repair, replacement of Automatic voltage regulator (AVR) full wave phase controlled adjustable (0-95V) 6A/12A Suitable for DG Set AVR(MODEL AS440)S/F STAMFORD and other equal models of 250/400 KVA including connecting and testing complete all as specified and directed.
6
-
-
... More
M & L Repair / overhauling radiator assembly of DG set by disconnecting and removing from the engine, dismantling the top and bottom chambers, descaling the sediments, scales, corrosion etc. by means of acid, cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets including arresting leakages, if any and fixing to the engine with new hoses, clips etc of 100 to 250 KVA DG Set complete all as specified and directed. Note: The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges.
5
-
-
... More
M & L Repair / overhauling radiator assembly of DG set by disconnecting and removing from the engine, dismantling the top and bottom chambers, descaling the sediments, scales, corrosion etc. by means of acid, cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets including arresting leakages, if any and fixing to the engine with new hoses, clips etc of 7.5 to 63 KVA DG Set complete all as specified and directed. Note: The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges.
5
-
-
... More
Supply, installation, testing and commissioning of factory made AMF panel outdoor cubical type front operated, totally enclosed, dust and vermin proof, floor mounted made out of CRCA sheet 2.2 mm thick , powder coated with all control wiring from front, oprated panel shall have provision for termination of UG cable for incomming / outgoing and necessary gland plates including cable termination with cable glands shall be provided at bottom of the panel suitable for DG set 125 KVA,415V, 3 phase 50 Hz 4 wire system including main supply failure monitor (ATS) control relays, voltage & current sensors, supply failure timer, restoration timer control unit incorporating automatic engine start/stop/Auto/manual/test, indicators for load/mains status with announciator, Push button for engine start/stop, 200 Amps Power contactors with OLR relay - 02 Nos and MCCB 4 Poles 200 Amps 25 KA rating with adjustable thermal over load and magnetic short circuit releases - 2 Nos, Copper busbar having 300 A rating for phase & 200A for Neutral which is duly insulated with proper colour coding , One battery charger in built for charging batteries with 12V 10A SCR Controlled Battery Charger, selector switch and DC voltmeter & Ammeter complete all as specified and directed.
1
-
-
... More
M&L for Earthing complete with galvanize steel earth plate 60 cm x 60 cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr filled around with layer of charcoal dust and salt and connected to GI earth strip size of 32x 6 mm by means of bolt nut and cheek nuts and washers of galvanized iron or steel and thimble and other ends of the earth strip connected to main switch board and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia light grade with funnel and wire mesh pcc 1:3:6 in chambers RCC 1:2:4 in pit cover reinforecd with 8 mm dia deformed bars 15 cm center both ways complete all as specified and directed.
1
-
-
... More
Disconnecting and taking out the turbo charger assembly complete from the engine of any make of 40 KVA to 63 KVA DG set , strip opening of turbo charger and replacement of turbo charger repair kit , assembling the complete part of the turbo charger and fixing back to the engine the tesing and commissioning for satisfactory working complete all as specified and directed.
2
-
-
... More
Disconnecting and taking out the turbo charger assembly complete from the engine of any make of 100 KVA to 160 KVA DG set , strip opening of turbo charger and replacement of turbo charger repair kit , assembling the complete part of the turbo charger and fixing back to the engine the tesing and commissioning for satisfactory working complete all as specified and directed.
1
-
-
... More
Disconnecting and taking out the turbo charger assembly complete from the engine of any make of 200 KVA to 250 KVA DG set , strip opening of turbo charger and replacement of turbo charger repair kit , assembling the complete part of the turbo charger and fixing back to the engine the tesing and commissioning for satisfactory working complete all as specified and directed.
1
-
-
... More
Disconnecting and taking out the turbo charger assembly complete from the engine of any make of 320 KVA to 380 KVA DG set , strip opening of turbo charger and replacement of turbo charger repair kit , assembling the complete part of the turbo charger and fixing back to the engine the tesing and commissioning for satisfactory working complete all as specified and directed.
1
-
-
... More
Supply & Fix in repair of ON LOAD change over switch , 4 pole , 630 Amps, in open execution / Panel mounting , front operated complete all as specified and directed.
1
-
-
... More
Supply & Fix in repair of ON LOAD change over switch , 4 pole , 400 Amps, in open execution / Panel mounting , front operated complete all as specified and directed.
1
-
-
... More
Supply & Fix in repair of ON LOAD change over switch , 4 pole , 315/320 Amps, in open execution / Panel mounting , front operated complete all as specified and directed.
1
-
-
... More
Supply & Fix in repair of ON LOAD change over switch , 4 pole , 250 Amps, in open execution / Panel mounting , front operated complete all as specified and directed.
2
-
-
... More
M & L for carrying out chemical analysis of water as per IS- 10500- 2012 from any govt Approved lab/Institute after collecting the water sample(SIXTEN NO) in separate suitable container as prescribed by the labs from following each pump house / borewell complete all as specified and directed by Engr-in-Charge :-
(a) 9 Sqn Pump House
(b) ETB PUMP HOUSE
(c) BOMBDUMP pump house
(d) Logistic Pump House
(e) NOR Pump House
(f) SOR pump House
(g) Tech Flt Pump House
(h) 06 Ens bore well
(j)CSD Old bore well
(k) BPCL bore well
(l) 1 Sqn bore well
(m) ‘A’ Flt pump House
(n) Tropo Pump Housek
(o) CCR new Pump House
(P) Singpur range pump House
(q)HQ Pump house
1
-
-
... More
M & L for carrying out chemical analysis &biological analysis of water as per IS- 10500- 2012 from any govt Approved lab/Institute after collecting the water sample of user end, (one sample) in separate suitable container as prescribed by the labs from location complete all as specified and directed.
5
-
-
... More
M&L for Cleaning of Static Water Tank 50,000 Gallon capacity of any description, dewatering & cleaning inside of the SWT by removing all depositions/fungus, other micro organism , sediment loose dirt/mud sludge, Vegetation, other foreign materials etc and also removing loose/unsound concrete/plaster including taking out and removing all disposal waste / spoil to a distance not exceeding 50 mtr and Brushing with nylon brush on walls & bottom surfaces , washing the cleaned surfaces with water and washing repeatedly and clean with water & cleaning of external surface with water, including two coats of white wash on internal surfaces and exposed external surface & clearance of any vegetation growth at least 2 mt around the swt to the satisfaction, and replacement of inlet ISI Marked, gun metal globe /gate valve of size 50 mm bore ,and 40/25 mm bore, and painting of cleaning date and next due cleaning date of each static water tank, complete all as specified and directed.
18
-
-
... More
M&L for Cleaning of RCC over head tanks of capacity 50000 Gallons any description cleaning inside of the over head tanks by removing all depositions/fungus other micro organism, sediment loose dirt/mud sludge, Vegetation, other foreign materials etc and also removing loose/unsound concrete/plaster including taking out and removing all disposal waste / spoil to a distance not exceeding 50 mtr and Brushing with nylon brush on walls & bottom surfaces , washing the surfaces with clean water and washing repeatedly with Rebekiense solution and clean with water & cleaning of external surface with water, including two coats of white wash and opening washout/drain pipe and sluice valve cleaning and refixing drain/washout pipe and painting two coats of drain pipe ,overflow pipe ,inlet, outlet pipe 150/100 mm dia,and and panting of cleaning date and next due cleaning date of each tank, complete all as specified and directed.
2
-
-
... More
M/L for replacement of RCC Over Head Tank Top side of LED aviation obstruction light fitting single unit 250 Volts built in 75 VA step up transformer & made out of aluminium alloy body complete all as specified and directed. Make Philips/Crompton/Bajaj
5
-
-
... More
M&L for Cleaning of RCC OH tank of capacity 5000 Gallons over head tanks of any description cleaning inside of the over head tanks by removing all despositions/fungus other micro organism, sediment loose dirt/mud sludge, Vegetation, other foreign materials etc and also removing loose/unsound concrete/plaster including taking out and removing all disposal waste / spoil to a distance not exceeding 50 mtr and Brushing with nylon brush on walls & bottom surfaces , washing the surfaces with clean water and washing repeatedly with Rebekiense solution and clean with water & cleaning of external surface with water, including two coats of white wash and opening washout/drain pipe and sluice valve cleaning and refixing drain/washout pipe and painting two coats of drain pipe ,overflow pipe ,inlet,outlet pipe 150/100 mm dia,and and panting of cleaning date and next due cleaning date of each tank complete all as specified and directed.
2
-
-
... More
Material and labour for earthing complete with galvanized steel earth plate electrode 600mmx600mmx6mm burried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.5 mtr below ground level) connected to GI strip 25mmx4mm means earthing lead by means of galvanized bolts,nuts and washers all as shown in electrical plate no. 3 of MES schedule part -I ,earth lead connected to earth test point and to main switch board etc with and including adequate quantity of charcoal dust and common salt all arround earth plate PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC 1:2:4 type B-1 using 20mm graded stone aggregate 40mm thick cover reinforced with 8mm TMT bars 03 Nos both way with 12mm dia round bar handle GI medium grade watering pipe 20mm dia with funnel and wire mesh etc complete all as specified and directed. Note:- The cost of earth lead including 7.5 mtr only from the top of earth electrode are deemed to be included under this item and additional earth lead if any required shall be measured separately under appropriate item of sch A.
5
-
-
... More
M&L in repair water lavel indicator gage of over head tank, replacement of copper flote of size 200mm dia with 2mm thik flexible steel wire roop and replacement of lavel Scale painting of numbering, abd replacement of gage move pully with complete accessory all as directed
3
-
-
... More
Development of existing bore well of any depth and in any position, of 150/200mm bore, with using suitable air compressor (having minimum 5.5 Kg /cm 2 pressure) to augment the yield to desire requirement of the bore well complete all as specified and directed.
Note :- (i) All necessary T&P and equipments required for flushing out / development of bore wells set etc shall be arranged by the contractor at his own cost.
(ii) Lifting out of submersible pump set, column pipes and cable before flushing out and lowering down of submersible pump set, column pipes and cable will be measured and paid for separately under respective items of Sch ‘A’ all as per specified and directed.
20
-
-
... More
Disconnecting the existing submersible pump set from supply line , dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity and in any position, alongwith existing column pipe 80/50mm dia and existing submersible cable of any size from the bore well (approximately 50 mtr depth of pump set from GL) complete and lowering after repair with all accessories including testing complete all as specified and directed.
Note (i) : Contractor shall take proper precautions while lifting out and removing motor/pump set from bore well so as to avoid any damage to column pipe and submersible cable. (ii) All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. (iii) Any item like Cable, column pipe & clamps if required shall be measured and paid separately.
5
-
-
... More
S & F star dalta starter fully automatic cum pump controller in sheet metal enclosure type MU-G complete with MCB Amp/Volt meter phase indicators 3 phase 415 Volts AC 50 Hz complete all as specified and directed.
2
-
-
... More
S & F star dalta starter fully automatic cum pump controller in sheet metal enclosure type MU-G complete with MCB Amp/Volt meter phase indicators 3 phase 415 Volts AC 50 Hz complete all as specified and directed.
2
-
-
... More
Supply fabrication & installation out door type MS Cover fabricated with 2.00 mm thick CRCA sheet duly painted with two coats of synthetic enamelled paint over a cot of red oxide primer of suitable size mounted on MS angle iron of 50X50X6 mm and having 4 legs of 1.00 mtr including grouting in PCC 1:3:6below ground level of size 100x100x10cm including 125 Amps MCCB 4 Pole 25 KA Make Legrand DPX Model-01 No and Star dalta Starter cum pump controller fully automatic in sheet )-01 No including metal enclosure MUG type 3 Phase,415 Volt AC Cat part No MUG 30 (CS 96008)-01 no including connected with copper cable of suitable size complete all as specified and directed.
2
-
-
... More
Supply fabrication & installation out door type MS Cover fabricated with 2.00 mm thick CRCA sheet duly painted with two coats of synthetic enamelled paint over a cot of red oxide primer of suitable size mounted on MS angle iron of 50X50X6 mm and having 4 legs of 1.00 mtr including grouting in PCC 1:3:6 below ground level of size 100x100x10cm including 100 Amps MCCB 4 Pole 25 KA Make Legrand DPX Model-01 No and Star dalta Starter cum pump controller fully automatic in sheet )-01 No including metal enclosure MUG type 3 Phase,415 Volt AC Cat part No MUG 20 (SS95975)-01 No including connected with copper cable of suitable size all as directed.
2
-
-
... More
M&L for construction of brick masonry valve pit / chamber complete with 3mm thick MS sheet cover with locking arrangement of size 1050 mm x 1050 mm x 1050 mm (depth) (internal dimensions) all as shown on CE(AF)/TD/EM/01 Sheet 1/1 dt 16 Mar 1993 with and including necessary excavation & earth work in any type of soil complete all as specified and directed.
6
-
-
... More
M&L for construction of brick masonry valve pit / chamber complete with 3mm thick MS sheet cover with locking arrangement of size 750 mm x 750 mm x 750 mm (depth) (internal dimensions) all as shown on CE(AF)/TD/EM/01 Sheet 1/1 dt 16 Mar 1993 with and including necessary excavation & earth work in any type of soil complete all as specified and directed.
6
-
-
... More
M&L for construction of brick masonry valve pit / chamber complete with 3mm thick MS sheet cover with locking arrangement of size 600 mm x 600 mm x 600 mm (depth) (internal dimensions) all as shown on CE(AF)/TD/EM/01 Sheet 1/1 dt 16 Mar 1993 with and including necessary excavation & earth work in any type of soil complete all as specified and directed.
6
-
-
... More
Earthing pit shall be precast PCC (1:3:6) type C1-20 mm stone aggregate and the cover of earthing pit shall be of precast RCC (1:2:4) Type B1 Using 20mm aggregate reinforced with 8mm dia round bars @75mm C/C both ways with ms handle 12mm dia with suitable handle fused with surface complete all as specified and directed..
Note:The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet of size 300x300x300mm size 40x40x5mm & length 60cm and grouted in the ground with PCC (1:3:6) using 20mm grade stone aggregate of size 200mm x 200mm x 250mm including necessary earth work for marking the result and its purpose of use
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements