Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date12 Nov 2024
Closing Date2 Dec 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Summary

Repair/maint Of Pumps Motors, Borewell Control Panel Water Supply Installation Including Cleaning Of Oht Tank And Ug Sumps, Upkeeping Of Pump House, Filtration Plants, Borewell And Other Connected Works At Afs Amla

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for taking out tube settler from tank, of size 3.8mx2.2mx2.7m (approx) by removing dirt, sludge with sudge cutter pump etc and cleaning entire internal surface/wall with wire brush by applying bleaching powder and fresh water and cleaning entire surface repeatedly with fresh water and bailing out soiled water including cleaning of channels and applying two coats of epoxy paint over a coat of red oxide primer and painting to inner surface of tanks with white cement based paint complete all as specified and directed.

3

-

-

... More
M&L for cleaning of Hypo Solution Tank/Chlorine contact tank of size 3.8mx1.8mx1.3m (approx) by cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and bailing out soiled water after cleaning applying one coat of synthetic enamel paint over a coat of red oxide all as specified and directed.

3

-

-

... More
M&L for cleaning of treated water tank of size 6.7mx3.8mx2m (approx) by removing dirt, sludge with sludge cutter pump and cleaning entire internal surface/wall with wire brush by applying bleaching powder and fresh water and cleaning entire surface repeatedly with fresh water and bailing out soiled water complete including applying two coats of white cement based paint on inner and outer walls of tank complete all as specified and directed. Note for item No. 1 to 6: (i) Location of tanks are STP 360 KLD (Tondon Camp), STP 200 KLD (BT Area), STP 125 KLD (ST Area) (ii) Items mentioned above shall be considered as one job for measurement, therefore contractor is directed to visit the site before quoting of rates. (iii) Quoted rate shall include the cost of cleaning with fresh water, de-watering with sludge cutter pump, suitable chemical for descaling air/water piping and necessary arrangement of ladder and any other T&P required at site for successful cleaning of tank.

3

-

-

... More
M&L for painting of the following set of plants/machineries by scrapping existing paint with emery paper and painting with two coat of synthetic enamel paint by spray painting machine over one coat of primer as per approved colour coding using Make: Asian/Berger/Nerolac paint manufacturer complete all as specified and directed. Pump Set with motor : 06 Nos. MS Sand Filter(DMF) : 01 No. MS Activated Carbon Filter : 01 No. Air Blower with motor : 02 Nos. MS Suction/discharge pipe line with valves : 01 Job Note : (i) Location: STP 360 KLD (Tondon Camp), STP 200 KLD (BT Area), STP 125 KLD (ST Area) (ii) Items mentioned above shall be considered as one job for measurement, therefore contractor is directed to visit the site before quoting of rates. (iii) Quoted rate shall include the cost of necessary arrangement of ladder and any other T&P required at site.

3

-

-

... More
Taking out old unserviceable butterfly valve of size 100 mm bore and S&F new butterfly valve wafer type CI body with integrally moulded liner of nitrile or EPDM stainless steel disc & stem, liver operated as per IS 13095 in PN 1.6 in including jointing material such as rubber gasket, bolts, nuts etc complete all as specified and directed.

2

-

-

... More
All as per item No. 8 above but of size 80mm bore

2

-

-

... More
All as per item No. 8 above but of size 50mm bore

2

-

-

... More
Taking out old unserviceable foot valve of size 100 mm bore. S&F new foot valve in MS/GI suction line as per IS 4038 including jointing material such as rubber gasket, bolts, nuts etc complete all as specified and directed.

2

-

-

... More
All as per item No. 11 above but of size 80mm bore

2

-

-

... More
Testing of treated water sample collected from STP Tondon camp 360 KLD, BT area 200 KLD, ST area 125 KLD in Regional Public Health Laboratory in Nagpur/Betul or any NABL accredited laboratory as per IS -10500 (2012) and submitting testing report with following parameters: (a) pH (b) BOD (mg/l) (c) COD (mg/l) (d) TSS (mg/l) (e) FC (mpn/1000ml (f) Resedual chlorine

33

-

-

... More
M&L for opening air blower set twin lobe type of capacity 250 m3/hr (Make: Everest/Usha) de-coupling blower & motor after isolating electric and air pipe connections, opening air compressor for repair/ overhauling & servicing and alignment of shaft including necessary lathe works and replacement of old /unserviceable items as mentioned below, reassemblying motor & blower set, greasing, connecting, testing on completion complete all as specified and directed. Note : (i) Location: STP 360 KLD (Tondon Camp), STP 200 KLD (BT Area), STP 125 KLD (ST Area) (ii) Spare parts shall be measured & paid seperatly under relevent items as supply only. (iii) Any minor parts not mentioned below but required for successful operation of air blower shall be provided by contractor without any extra cost.

3

-

-

... More
Supply only blower bearing of size suitable for 250m3/hr

2

-

-

... More
Supply only blower V belt of existing size and model

2

-

-

... More
Supply only blower pulley of existing size.

2

-

-

... More
Supply only blower oil seal & packing

2

-

-

... More
Supply only blower suction filter of existing size and make.

2

-

-

... More
Supply only fan belt size A-34

2

-

-

... More
Supply only blower oil of existing grade.

3

-

-

... More
M&L for taking out unserviceable/burnt raw sewage pump set capacity 7.5/10 HP from sewage sump, opening pump set after isolating the electric and pipeing connections for repair/overhauling including replacement of unserviceable items as mentioned below inclding necessary lath work, reassemblying the pumpset, greasing, connecting and testing complete complete all as specified and directed. Note : (i) Spare parts shall be measured & paid seperatly under relevent items as supply only. (ii) Any minor parts not mentioned below but required for successful operation of air blower shall be provided by contractor without any extra cost.

2

-

-

... More
Supply only pump shaft sleeve/bush made out of gun metal

1

-

-

... More
Supply only key for main shaft/impeller

1

-

-

... More
Supply only pump shaft

1

-

-

... More
Supply ball/roller bearing complete

1

-

-

... More
Supply only CI impeller

1

-

-

... More
M&L for taking out unserviceable/burnt raw sewage feed pump set capacity 5 HP from sewage sump, opening pump set after isolating the electric and pipeing connections for repair/overhauling including replacement of unserviceable items as mentioned below inclding necessary lath work, reassemblying the pumpset, greasing, connecting and testing complete complete all as specified and directed. Note : (i) Spare parts shall be measured & paid seperatly under relevent items as supply only. (ii) Any minor parts not mentioned below but required for successful operation of air blower shall be provided by contractor without any extra cost.

4

-

-

... More
Supply only pump shaft sleeve/bush made out of gun metal

1

-

-

... More
Supply only key for main shaft/impeller

1

-

-

... More
Supply only pump shaft

1

-

-

... More
Supply ball/roller bearing complete

2

-

-

... More
Supply only CI impeller

1

-

-

... More
M&L for rewinding of 10 HP, 3 phase motor of submersible non clog pump set by providing high quality of class 'B' paper insulation inside slots and rewinding with PVC insulated copper wire of existing size and gauge as per existing rapping up with high quality cotton tape and varnishing with super quality oil including drying upto desired temperature and desired time complete including taking old burnt out copper winding, insulation material and cleaning the slots complete all as specified and directed.

2

-

-

... More
All as per item No 34 above but for 5 to 7.5 HP, 3 Phase

4

-

-

... More
M&L for cleaning of main raw sewage receiving tank installed at different location of STPs in Tandon Camp, ST Area, BT Area of size 4.0mx3.0 m x 3.0 m (appox), cleaning entire internal surface/wall by removing dirt/mud/ slurry grit waste material, sludge etc by sludge cutter pump or sludge suction machine or Honey sewer machine of suitable capacity and throw out the waste where sewage are disposed off and cleaning the room area with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and bailing out all waste water complete all as specified and directed. Note: Quoted rates shall include cleaning using fresh water & sludge cutter pump/ honey sewer machine and ladder for man entering into tank for removing of sludge from tank and de-watering will be the contractor scope under his own arrangement complete .

8

-

-

... More
Taking out old chemical dosing pump from STP. S&F chemical dosing pump (electromagnatic diaphragam type) of capacity 6 ltrs /hour @ 04 kg back pressure including connected accessories complete all as specified and directed. Make: Milton Roy Model: V-13 PP

2

-

-

... More
Taking out old chemical dosing pump from STP. S&F chemical dosing pump (electromagnatic diaphragam type) of capacity 5 ltrs /hour @ 04 kg back pressure including connected accessories complete all as specified and directed. Make: Rmco Model: RC10(digital)

2

-

-

... More
Supply and fixing in replacement of dosing tank PVC 200 Ltr capacity white in colour all as per site requirement at Tandon Camp STP.

2

-

-

... More
Supply and fixing in replacement of dosing tank PVC 100 Ltr capacity white in colour all as per site requirement at ST STP and BT STP .

4

-

-

... More
S&F 50 mm bore sewage hose pipe (flexible) fitted in sewage pump motor for draining out sewage water along with hose clamp of suitable size installed at various location of STP Plant,

50

-

-

... More
Supply only Trichloroisocyanuric Acid (90%) (TCCA 90), Effective Chlorine : ≥90%, Size 5-8 Mesh Appearance : White Granuals or powder, pH : 2.7 to 3.3 in 50 Kg HDPE drums complete.

800

-

-

... More
Supply only calcium hypochlorite granules having chlorine content = 65% in air tight HDPE drums complete.

200

-

-

... More
Supply only Sodium Hypochlorite Solution (NaOCl) in HDPE drum of capacity 50 Kg complete.

300

-

-

... More
Supply only white granules raw salt in 50 kg bags packing (NaCl) complete. Note for item No. 42 to 45: Supply only items shall be taken on charge vide receipt voucher duly signed by all concerns.

60

-

-

... More
Testing potable water sample from the nearest district Laboratory, PHE Madhya Pradesh or any NABL certified lab including transportation complete all as specified and directed. Note: The rate quoted by contractor includes the following: 1. Collecting water samples in sterlised containers from the location as directed by Eng-in-Charge 2. Transporting the collected sample immediately to the lab and submitting the test report to the Eng-in-Charge.

12

-

-

... More
M&L for oiling, servicing, greasing of existing manually operated gate of check dam of size 3.0x1.5 metre at the depth of 9.5 Mtr below the ground level at Kudmud Pump House including taking off sluice gate on other side of check dam and refixing the same after necessary repair including fabricating and making good dents on edges of gate bolts holes with additional reinforcement of 50x6 mm flat iron with drilled holes on the edges all round suitable insertion sheet with new set of bolts nuts (90 nos) including repacement suitable size ball bearings for existing 40 mm dia pipe in gate spindle by detaching the handle in addition to this necessay welding work and alteration required at site complete all as specified and directed.

2

-

-

... More
Note for item No 47 above Note: (i) The periodicity of repair/service to be carried out shall be before start of Mansoon (opening of gate) and after Monsoon (Closing of gate), hence all nut, bolts and washer fitted in gate of dam shall be replaced accordingly. (ii) The contractor shall ensure proper machineries and skilled technician to be used in opening and closing of dams gate. (iii) Before opening and closing of check dam gate the contractor will inform to concerned Engineer-in-Charge. (iv) The job shall include necessay welding and alteration work in check dam gates, therefore contractor shall quote rate accordingly.

-

-

-

... More
S&F water level indicator at overhead tank, float and board type with specification as measuring range 1-6 mtrs, float valve, wire pointer MS epoxy coated red coloured, scale 8" wide, housing, pulley and appropriate MS channel for support and mounting including all parts being alluminium powder coated. The job involves all alteration at site complete all as specified and directed.

1

-

-

... More
M&L for cleaning of underground water storage tank/sump after scrapping out the scales/deposits from all inner surfaces of sump thoroughly washing with bleaching powder solution (mixed @ 0.5 Kg of bleaching powder of chlorine content 30% per 1000 liters of water), bailing out the settled materials completely away from the site within 100 metres distance, cleaning the tank with clean water and finally sterilizing the tank as mentioned in notes below and resetting the existing level readings complete including taking down and re-fixing of foot valve after necessary cleaning, repairs etc., and replacing minor parts if any required for proper functioning of foot valve, testing and writing “TANK CLEANED ON…..”(date), “DUE DATE ON…..(date) with 10 cm size white letters on black back ground by engaging skilled artist using best quality synthetic enamel paint all as specified and directed for the capacity 50,000 Glns Semi UG Sump at Filter House

2

-

-

... More
All as per item No 49 above but for Capacity 25,000 Glns UG sump at site 'C' X Area

2

-

-

... More
All as per item No 49 above but for Capacity 1,00,000 Glns UG Sump at Malanjhiri Pump House

1

-

-

... More
All as per item No 49 above but for Capacity 20,000 Glns RCC Jack Well at Kudmud Pump House

2

-

-

... More
All as per item No 49 above but for Capacity 2,00,000 Glns RCC OH at 80 feet staging at Filter House. Note for Item No. 49 to 53 The contractor should follow the following procedure in addition to above which demeed to be included in the contractor quoted rate. (a) Mechanized removal of all dirty water by using high capacity submersible pumps. (b) Removal of sludge by using vaccum operated pump. (c) Cleaning of walls, ceiling and ground by high pressure rotary jet of 12 Kg/sqcm pressure. (d) Removal of all dirt particles by industrial wet vaccum cleaner leaving the tank physically cleaned as per Engineer-in-Charge. (e) Sterilization of tank by agents eco-friendly, bio-degradable and highly effective against all pathogens, or approved chemical.

1

-

-

... More
(f) Sterilization of tank atmosphere by industrial UV radiator leaving the tank complete sterilized. (g) All required T&Ps, lubricants/oils and materials will be supplied by the contractor during the work. (h) Fresh air to be blown into the tank for a period before allowing a person to enter. The cleaner should wear protective clothing, including gloves, boots, safety helmet and glasses. Contractor should make sure someone remains outside the tank, next to the access hatch all the time in case the cleaner has an accident.

-

-

-

... More
M&L for taking out carefully complete filter media from the existing gravity filter at filter house and stacking in segregation size/ item wise (viz. gravel/pebble/ grit/ sand) outside the plant house at a distance exc 20 m and n.exc 50 m and cleaning the all filter media (viz. gravel/pebble/ grit/ sand) using bleaching powder and water including refiling the cleaned filter media at the same location complete all as specified and directed.

1

-

-

... More
M&L for complete removal of existing water proofing treatment of water tank by removing old painted surfaces using paint removers or burning off by blow lamps and cleaning with scrapers etc, and applying two coats nontoxic, non-corrosive water proof coating over a coats of primer inside the tank complete all as specified and directed. Make: Sikagard-67 / Dr Fixit Pidifine 2K / Clean Tech PW or equivalent as certified by CFTRI, Mysore for potable water/ BIS Note: (i) Surface preparation and application procedure shall be as per manufacturer’s guidelines and directions of Engineer-in-Charge. (ii) The paint used should not contain any harmful chemical content to pollute drinking water. Manufacturer certificate for the same is mandatory and contractor must produce the certificate as mentioned above before application to Engineer-in-Charge.

400

-

-

... More
M&L for taking out carefully lamella clarifier plate made out of FRP (Fibre reinforced plastic confirming to BIS standards) of size 121cm x 91cm x 3 mm thick from water treatment plant including cleaning using brush and bleaching powder with water and refixing in same position complete all as specified and as directed.

250

-

-

... More
S&F in repairs lamella clarifier plate made out of FRP (Fibre reinforced plastic confirming to BIS standards) of size 1210mm x 910mm x 3mm complete all as specified and as directed.

20

-

-

... More
M&L for scrubbing old paint from aeration tower inner and outer area along with iron grill and ladder and painting of internal and external area of aeration tower with existing colour with two coats of water proof colour of approved colour in complete all as specified and directed.

1

-

-

... More
M&L for taking out old/rusted wiremesh from MIMO filteration plant. S&F new wire mesh of suitable size fitted in angle iron frame with proper nuts, bolt, welding and painting the wire mesh with two coats of blue colour paint on wire mesh and black paint on angle iron /flat iron complete all as specified and directed at site. Note: The cost of welding / cutting/ jointing of flat iron shall include in quoated rate.

30

-

-

... More
S&F submersible pump set electric driven of discharge capacity 60 to 420 LPM at 30 to 82 mtr head, multistage, delivery size 50 mm dia with 5 HP motor AC, 3 phase, 415 Volts, 50 Hz, conforming to IS: 8034 for 150 mm dia borewell including DOL starter of suitable for 5 HP submersible pumpset complete all as specified and directed.

3

-

-

... More
S&F submersible pump set electric driven of discharge capacity 60 to 420 LPM at 35 to 135 mtr head, multistage, delivery size 50 mm dia with 7.5 HP motor AC, 3 phase, 415 Volts, 50 Hz, conforming to IS: 8034 for 150 mm dia borewell including DOL starter of suitable for 7.5 HP submersible pumpset complete all as specified and directed.

1

-

-

... More
M&L for disconnecting and taking up vertical turbine pump set of capacity 45 HP from the existing well and servicing the VT Pump motor by changing gland rope & bearing, oiling, greasing of pump & motor, rethreading of pipes if, necessary and other related works by which the motor runs smoothly and painting of complete VT Pump with one coat of synthetic enamel paint after cleaning and scrubbing complete and fixing back to its original position connecting all wire/parts and testing for satisfactory operation all as specified and directed. Note: Cost of minor items / spares such as nut, bolts, washer, gaskets required for effective functioning of pump set shall be deemed to included in quoted rate.

2

-

-

... More
M&L for dismantling centrifugal pump set from the existing foundation after disconnecting the inlet/out let pipe connections, disconnecting the electric supply cables and transporting to repair work shop complete, servicing the pump set including replacement of unserviceable spare parts reassembling and re-fixing to its original position, making mechanical & electrical connections and testing pumping set complete all as specified and directed for the centrifugal pupm set coupled with electric motor of capacity 20 HP, 3 phase Note: (i) Spares to be replaced shall be measured and paid separately as supply only in respective item. (ii) Rewinding work shall be measured and paid separately in respective items. (iii) In addition to above the rate quoted by contractor deemed to be includes of transportation, lifting of pump set and replacement of worn out minor parts other than the supply only items such as bushes, check nut etc., if any required for proper functioning of pump set.

1

-

-

... More
All as per item No 63 above but Centrifugal pump set coupled with electric motor of capacity 35 HP to 50 HP, 3 phase

4

-

-

... More
All as per item No 63 above but Centrifugal pump set coupled with electric motor of capacity 60 HP 3 phase,

2

-

-

... More
M&L for strip opening of pump and replacement of unserviceable parts such as mechanical seal, SS sleeve, SS bearing sets, wear rings, O rings, gasket, gland cap & bolts alongwith greasing with necessary lathe works including checking/ making proper allignment of motor & pump and testing of pump set on load complete all as specified and as directed for the capacity of pump 20 HP Note: Cost of all the material required for servicing is deemed to be included in this rate.

2

-

-

... More
All as per item No 66 above but Capacity 35 HP

2

-

-

... More
All as per item No 66 above but Capacity 45 HP/ 50 HP

2

-

-

... More
All as per item No 66 above but Capacity 60 HP

2

-

-

... More
M&L for strip opening of induction motor and taking old burnt out copper winding, insulation material, cleaning the slots and rewinding of motor by providing high quality of class 'B' paper insulation inside the slots, rewinding with super enameled copper wire of existing size and gauge, rapping up with high quality cotton tape and varnishing with super quality oil including drying upto desired temperature and desired time including replacement of bakelite terminal testing on completion complete all as specified and directed for the capacity Up to 3 HP, 3 phase, 415 Volts 50 Hz

2

-

-

... More
All as per item No 70 above but 20 HP, 3 Phase, 415 Volts 50 Hz

1

-

-

... More
All as per item No 70 above but 35 HP, 3 Phase, 415 Volts 50 Hz

1

-

-

... More
All as per item No 70 above but 45/50 HP, 3 Phase, 415 Volts 50 Hz

2

-

-

... More
All as per item No 70 above but HP, 3 Phase, 415 Volts 50 Hz

2

-

-

... More
Taking out existing old leaking suction/ discharge pipe of pump set. S&F GI tubing 100 mm bore medium grade including necessary fitting such as socket, elbow, reducer, nipple, bend, flange, nut & bolts etc and make good disturbed surfaces to match the existing surface complete all as specified and directed.

60

-

-

... More
All as per item No. 75 above but for 80 mm bore medium grade complete.

150

-

-

... More
All as per item No. 75 above but for 50 mm bore heavy grade complete.

120

-

-

... More
Taking out defective submersible pump set of capacity upto 7.5 HP from borewell/shallow well for repair by lifting borewell pipe of any type or size from 40 to 70 mtrs depth after disconnecting electrical and water connections complete by means of chain pully block or any other T&P, transporting to E/M store/ work shop for repair and re-installing back to borewell, lowering and reconnecting electrical and water connections and testing on full load compete all as specified and directed. Note : (i) Taking out & lowering of submersible pump set shall be done by highly skilled mechnics. (ii) Repairing of pump/motor and spare parts shall be be measured and paid separately in respective items.

10

-

-

... More
M&L for repairing of vertical submersible pump set upto 7.5 HP capacity by opening the pumpset and replacement of unserviceable parts such as 'O' ring, valve metal sheet, brass sleeve, stage bowl, thrust bearing assembly, brass bush, coupling asembly and other minor parts including oiling/ greasing the lubricating parts and reassembling, painting of submersible pumpset with one coat of synthetic enamel paint after cleaning and scrubbing complete including testing on load all as specified and directed. Note: (i) Lathe work and replacement of unserviceable parts mentioned above shall be included in rate quoted including greasing, overhauling and packing of pump set. (ii) Cost of other spares such as nut, bolts, washer, gaskets, paints and minor parts not specified above but required for successful functioning of pump shall be deemed to included in quoted rate.

10

-

-

... More
S&F in replacement, multi stranded, 4 sqmm, 3 core, PVC insulated and sheathed flat submersible cables, 1100 volts, with copper conductor, ISI marked, IS- 694 including connecting to motor & starter with suitable size copper thimble through PVC conduit complete all as specified and directed.

150

-

-

... More
All as per item No. 80 above but of size 6 sqmm, 3 core

100

-

-

... More
All as per item No. 80 above but of size 16 sqmm, 3 core

50

-

-

... More
All as per item No. 80 above but of size 25 sqmm, 3 core

40

-

-

... More
M&L for taking out horizontal (openwell) submersible pump set 5 HP capacity from static water tank/open well, repairing by opening the pumpset and replacement of unserviceable parts such as 'O' ring, valve metal sheet, brass sleeve, stage bowl, thrust bearing assembly, brass bush, coupling asembly and other minor parts including oiling/ greasing the lubricating parts and reassembling, painting of submersible pumpset with one coat of synthetic enamel paint after cleaning and scrubbing complete including testing on load all as specified and directed. Note: (i) Lathe work and replacement of unserviceable parts mentioned above shall be included in rate quoted including greasing, overhauling and packing of pump set. (ii) Cost of other spares such as nut, bolts, washer, gaskets, paints and minor parts not specified above but required for successful functioning of pump shall be deemed to included in quoted rate.

4

-

-

... More
M&L for strip opening of borewell/openwell submersible motor of capacity 5 HP, 3 phase, taking out burnt winding carefully, cleaning of slots, rewinding with PVC insulated copper cable of appropriate size matching with manufacturer's design including replacement of all insulating materials such as glass paper, insulated sleeves, varnishing, drying up as applicable, re-assembling complete all as specified and as directed.

10

-

-

... More
S&F in repair pressure gauge, 100 mm size dial, 0-14 kg rating fitted on delivery side of pump set, including all necessary items required like ball valve and connecting pipe & dismantling the old one complete all as specified and directed.

10

-

-

... More
S&F voltmeter digital type 0 to 500 V range, flush mounting type with 3 phase selector switch including dismantling old one complete all as specified and as directed.

5

-

-

... More
S & F ammeter digital type 0 to 100 A range, flush mounting type with 3 phase selector switch, including dismantling old one complete all as specified and as directed.

5

-

-

... More
S&F indicator lamp LED type, 230 Volts, AC (for indicating R, Y, B phases) with necessary fixing arrangement in panel incl dismanlting old one complete all as specified and directed.

10

-

-

... More
M&L for preparation of old painted surface of plant/ machinery/ MS structures of Filteration Pump House installation such as 50 HP Motor & Pump set-03 Nos with their sluice valve & NRV, delivery & suction pipe line, air vent pipe of UG sump, iron lid of UG Sump & channel base frame and valve pit cover- 15 Nos. etc by removing / scraping old paint all dirt, dust, grease, oil etc and painting with two coats of synthetic enamel paint of approved colour (Smoke grey, red, black, white) over a coat of red-oxide primer complete all as specified & directed.

1

-

-

... More
M&L for preparation of old painted surface of plant/ machinery/ MS structures of Site 'C' Pump House installation such as 20 HP Motor & Pump set - 02 Nos with their sluice valve & NRV, delivery & suction pipe line, air vent pipe of UG sump, iron lid of UG Sump & channel base frame and valve pit cover- 04 Nos. etc by removing / scraping old paint all dirt, dust, grease, oil etc and painting with two coats of synthetic enamel paint of approved colour (Smoke grey, red, black, white) over a coat of red-oxide primer complete all as specified & directed.

1

-

-

... More
M&L for preparation of old painted surface of plant/ machinery/ MS structures of Malanjhiri Pump House installation such as 30/50 HP Motor & Pump set - 04 Nos with their sluice valve & NRV, delivery & suction pipe line, air vent pipe of UG sump, iron lid of UG Sump & channel base frame and valve pit cover- 10 Nos. etc by removing / scraping old paint all dirt, dust, grease, oil etc and painting with two coats of synthetic enamel paint of approved colour (Smoke grey, red, black, white) over a coat of red-oxide primer complete all as specified & directed.

1

-

-

... More
M&L for preparation of old painted surface of plant/ machinery/ MS structures of Kudmud Pump House/Mowad Nala Pump House installation such as 30/50 HP Motor & Pump set - 03 Nos with their sluice valve & NRV, delivery & suction pipe line, air vent pipe of UG sump, iron lid of UG Sump & channel base frame and valve pit cover- 02 Nos. etc by removing / scraping old paint all dirt, dust, grease, oil etc and painting with two coats of synthetic enamel paint of approved colour (Smoke grey, red, black, white) over a coat of red-oxide primer complete all as specified & directed.

1

-

-

... More
S&F in replacement tyre coupling & MS flange set suitable for 45/50 HP motor pump set of different pump house including nuts/ bolts/washer of required size by proper allignment of motor & pump set complete all as specified and directed.

4

-

-

... More
S&F in replacement tyre coupling only suitable for 30/45/50 HP motor pump set at different pump house and proper allignment of motor & pump set complete all as specified and directed.

4

-

-

... More
S&F in replacement star/spider coupling & coupling hub set suitable for 45/50 HP motor pump set of different pump house including nuts/ bolts/washer of required size by proper allignment of motor & pump set complete all as specified and directed.

3

-

-

... More
S&F in replacement nitrile rubber star coupling only suitable for 30/45/50 HP motor pump set at different pump house and proper allignment of motor & pump set complete all as specified and directed.

8

-

-

... More
S&F in repairs single phase preventer existing motor starter.

5

-

-

... More
S&F in repairs MCCB 63 Amps, 3 pole, 415 V, 36 KA suitable for motor back up protection in exisitng panel with connected accessories complete all as specified and directed.

4

-

-

... More
All as per item No. 99 above but of rating 100 Amps.

4

-

-

... More
All as per item No. 99 above but of rating 125 Amps.

3

-

-

... More
All as per item No. 99 above but of rating 160 Amps.

2

-

-

... More
All as per item No. 99 above but of rating 250 Amps.

1

-

-

... More
S&F in repairs power contactor, type MNX-70, 3 pole, AC-3 rating current 70 Amps complete all as specified and directed.

3

-

-

... More
S&F in repairs power contactor, type MNX-50, 3 pole, AC-3 rating current 50 Amps complete all as specified and directed.

2

-

-

... More
S&F in repairs power contactor, type MNX-40, 3 pole, AC-3 rating current 40 Amps complete all as specified and directed.

4

-

-

... More
S&F in repairs power contactor, type MNX-9, 3 pole, AC-3 rating current 9 Amps complete all as specified and directed.

2

-

-

... More
S&F in repairs power contactor, type ML-4, 3 pole, AC-3 rating current 70 Amp complete all as specified and directed.

2

-

-

... More
S&F in repair thermal over load relay, type MN-2 directly operated for relay range 9-15 Amps, with connected accessories complete all as specified and directed.

2

-

-

... More
S&F in repair thermal over load relay, type MN-5 directly operated for relay range 45-75 Amps, with connected accessories complete all as specified and directed.

2

-

-

... More
S&F in repair thermal over load relay, type MN-5 directly operated for relay range 66-110 Amps, with connected accessories complete all as specified and directed.

2

-

-

... More
S&F in repair electronic timer, ST-100 type ranging from 3-30/12-120 secs complete all as specified and directed.

4

-

-

... More
S&F in repair DOL starter in sheet steel enclosure, AC-3 rating, relay range 9-15 Amp complete all as specified and directed.

3

-

-

... More
S&F in repair fully automatic star delta starter in sheet steel enclosure, AC-3 rating, relay range 9-15 Amp complete all as specified and directed.

2

-

-

... More
S&F in repair fully automatic star delta starter in sheet steel enclosure, AC-3 rating, relay range 30-50 Amp complete all as specified and directed.

2

-

-

... More
S&F in repair MCB TPN 'B' curve 40 to 100 Amp 240 volt 50 Hz 10 KA complete.

5

-

-

... More
S&F in repair MCB TPN 'B' curve 16 to 32 Amp 240 volt 50 Hz 10 KA complete.

5

-

-

... More
M&L for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 25 x 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of panel/machinery etc at the other end including 32 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified & directed.

10

-

-

... More
S&F GI strip of size 25 x 4 mm with saddles and fixing screws, etc, down conductors/ pump motors/ pannels where required complete all as specified and directed.

40

-

-

... More
Restringing & stretching of LT OH lines ACSR conductor of any size including cleaning of insulators & aluminium wire for binding of conductor, cutting/trimming of tree branches on both sides of conductor all as directed 3 phase 3 wire system measured as single run all as directed

850

-

-

... More
Labour only for cleaning of surrounding area of water filteration plant, borewell, malanjhari pump house by cutting/taking out grass, shrubs & bushes and pruning tree branches by employing labour including using own T&P as required to do the job and thrown all waste outside the pump house complete all as specified and directed.

600

-

-

... More
S&F in repairs single phase induction motor 120 watts, 1000 rpm 6 pole pad mounting suitable for fixing on FRP lid alongwith all accessories including taking out old unserviceable motor complete all as specified and directed

2

-

-

... More
M&L for repair of electro chlorination plant by repairing chlorinator cell and wiring of power pack panel with PVC insulated FR grade multistranded copper conductor of existing size, repairing & cleaning and overhauling of electrolyser cell complete for proper functioning, scrubbing out old rusted paint from outside & inside panel box and then spray painting with one coat of red oxide primer and two coats of synthetic enamel paint for hypochloride solution tank, power pack body and greasing of wheels ensuring free movement along with scrapping old paint from iron ladder support and painting one coat of red oxide and and one coat of black paint and replacement of UPVC pipe fixed in bottom of the tank along with all accessories complete all as specified and directed.

1

-

-

... More
S&F only following items of electro chlorinator plant during repair including making copper cable connections with lugs, connectors, ferrule, glands of suitable size as per requirement etc complete all as directed : - Rotary and toggle switch Note: minor parts not specified below but required for successful functioning of chlorinator shall be deemed to included in quoted rate.

1

-

-

... More
All as per itme No 124 above but Thermal Overload Relay MN type (4 to 7.5 amps) compaitable with MNX-9 contactors

1

-

-

... More
All as per item No 124 above but Contactor 3 pole, current rating upto 9 Amp

1

-

-

... More
All as per item no 124 above but Connector 3/4 way double row bakelite

4

-

-

... More
All as per item No 124 above but CPVC Ball Valve size 50mm.

2

-

-

... More
Supply only Chloroscope/ chlorine test kit with coloured sample complete with all testing fitment and OT solution in rexene finish box for measurement of chlorine level in water showing indication 0.1, 0.2, 0.5, 1.0, 1.5, 2.0 & above including box type indicator showing indication along with two numbers test tube and reagent complete all as specified and directed. Make: Rmco

4

-

-

... More
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed.

130

-

-

... More
Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.

128

-

-

... More
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at level not exc. 1.5 m above starting point.

2

-

-

... More
Supply and laying HDPE DWC pipe size outer dia 63 mm, inner dia 50 mm for LT cable protection including sockets, bends etc complete all as specified and directed.

400

-

-

... More
Supply lay & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for the size of cable 16 Sq mm 4 core

250

-

-

... More
All as per item No 134 above but 25 Sqmm 3.5 core

200

-

-

... More
All as per item No 134 above but 35 Sqmm 3.5 core

150

-

-

... More
S&F LT aerial bunched cables 1100 Volts grade of size 3Cx25 Sqmm (phase) + 25Sqmm (bare massenger) ISI marked XLPE insulated aluminium cable twisted over a central bare aluminium alloy messenger wire for use on LT overhead lines conforming to IS:8130/1984, IS:14255/1995 and IS:398 (iv) 1994 with latest amendment including necessary connection LT/starter panel with suitable size thimble in replacement of existing OH conductor complete all as specified and directed.

115

-

-

... More
Supplying & laying GI Tubing 50 mm dia Light grade pipe with connecting acessories complete in trench for road and on surface/,wall for protection all as dirrected

30

-

-

... More
M&L for flushing of complete borewell different locations by using 210 CFM compressor and heavy duty driller machine to deliver the high air pressure at bottom of borewell by pumping muddy water and clear the chockup of boring hole till the water becomes free from mud and clear for potable complete all as specified and directed. Note: Necessary T&P shall be arranged by contractor for taking out and lowering of submersible pump set and cost of same are deemed to be included in the quoated rate.

24

-

-

... More
M&L for painting of steel tubular poles any type of 8.5 to 9 mtrs height with two coats of aluminium paint including painting to cross arms, brackets and clamps etc. including preparation of surfaces by scrubbing and cleaning with wire brush complete.

40

-

-

... More
S&F PVC junction box of size 205mmx255mmx112mm, shockproof, rust proof, 100% waterproof, pole mounting arrangement, fire retardent with aluminium bus bar rating three phase 150 Amps and neutral 75 Amp, IP 65 having provision for metric knockouts for cable entry upto 25 Sqmm including GI clamps and opening of door by hindges with closing clamp complete all as specified and directed.

40

-

-

... More
S&F in repair retro reflective boards in shape of rectangular size 1mx1.4 m made out of 2 mm thick stainless steel both side bounded / pasted with high prismatic sheet manufactured by avery dennison of 3 M with desired letter/ logos designed as directed. The board shall be supplied with and including stainless steel frame made out of 25 mm dia pipe in frame around duly welded with and including stainless steel sheet and stainless steel post of 38 mm dia and full length of 2.20 m one side and 2.8 m other side complete all as specified and as directed. Note: The rate of fixing of board with PCC 1:2:4 type B2 filling of size 45x45x50 cm to be included in the quoated rate. The board description should be given or directed.

3

-

-

... More
S&F in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete including necessary electrical connections from junction box to fitting terminal with 3 core 1.5 sq mm cable complete all as specified and directed.

12

-

-

... More
S&F in repalcement building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts, pre wired and necessary mounting arrangements and provision of 1.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified & directed.

15

-

-

... More
Supply only chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill (Steaqua 411 AE) for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation for power free automatic water sanitiser / conditioning treatment station dosing system complete all as directed.

2

-

-

... More
M&L for rubber insulating mating of size 2 mtr x 01 mtr x 6 mm thick as per IS all as per specified and directed.

4

-

-

... More
M&L for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.

5

-

-

... More
M&L for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like including necessary form work etc, complete all as specified & directed.

5

-

-

... More
M&L for prepration of old painted surface of kerb stone/walls at filter pump house and painting of surface with two coats of synthetic enamel paint in existing yellow and black colour all as specified and as directed.

100

-

-

... More
Note:- The amount of Rs 166881.00 against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.