Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Oct 2024
Closing Soon21 Nov 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681443_1Tender No
GE/SGR/TOK-37 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, laying and testing in repalcement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
500
-
-
Supply, laying and testing in repalcement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm, 4 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
300
-
-
Supply, laying and testing in repalcement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 4 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
200
-
-
Excavation in trenches in hard/dense of soil not exceeding1.5 meter wide and not exceeding 1.5metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed.
283
-
-
Excavation in trenches n.exc 1.5m wide and exc 1.5m and n exc 3.0 m depth in any type of soil complete all as specified and directed.
1
-
-
Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
156
-
-
Removing excavated materials (soil) not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and directed.
127
-
-
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
9300
-
-
M&L for local river sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as directed
113
-
-
S&F in repair pipe galvanised iron light grade ( ISI marked )with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed of 40 mm dia complete all as specified and directed.
60
-
-
All as per item No 13.00 above but 50 mm dia
42
-
-
All as per item No 13.00 above but 80 mm dia
36
-
-
All as per item No 13.00 above but 100 mm dia
20
-
-
M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and white shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including taking down of old PCC pole and making good to match existing area complete all as specified and as directed.
20
-
-
Supply and fixing in replacement of cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of paint. complete all as specified and directed.
8
-
-
M&L in repair of aluminium conductors Galvanised steel reinforced (ACSR conforming to IS : 398) Part-II)-1976 for HT/LT over head lines on steel poles/ PCC Poles including copper binding wire and suitable szie of GI clamps complete all as specified and directed.
7
-
-
Material and labour for GI wire 4mm dia (8 SWG) stretching and fixing on pole for continious earth conductor, Guard wire 3.2 mm (10 SWG) for cradle (Hexagonal/rectangular) including binding wire all as specified and directed..
3
-
-
S&F pin type polymer/porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel spindle, two Galvanised iron washers and one GI nut 100 mm height , 65 mm dia suitable for 1100 Volt working pressure grade (LT) complete all as specified and directed.
80
-
-
S&F shackle type polymer/porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel straps, washers, suitable bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 volts working pressure grade complete all as specified and directed.
54
-
-
M & L for plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate in foundation of PCC poles/ struts, etc. including form work complete all as specified and directed
1
-
-
M & L for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of stay assy/ pole etc, including form work complete in all as specified and directed
11
-
-
M & L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate for coping/plinth of poles, including necessary form work finished even & smooth without using extra cement all as specified and directed
4
-
-
M&L for earthling complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 meters below normal ground level surrounded from all sides by mixture of charcoal & common salt & electrode connected to and including galvanised earth wire 4.0 mm dia as earthling lead by means of bolts, nuts, check-nuts, and washers of galvanised iron and GI protection pipe light grade 40 mm dia connected to earth point , GI pipe light grade 20 mm dia for watering funnel with wire mesh all as specified & indicated in Electric plate no 3 of SSR 2009 part I complete all as specified and directed.
6
-
-
M&L for earthling complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 meters below normal ground level surrounded from all sides by mixture of charcoal & common salt & electrode connected to and including galvanised earth strip 25x4mm as earthling lead by means of bolts, nuts, check-nuts, and washers of galvanised iron and GI protection pipe light grade 15 mm dia connected to earth point , GI pipe light grade 20 mm dia for watering funnel with wire mesh all as specified & indicated in Electric plate no 3 of SSR 2009 part I complete all as specified and directed.
8
-
-
Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 400 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
1
-
-
Item No. 28.00 Contd...
(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ 250Amps microprocesor based with rupturing capacity 36 KA-01 No. (B) OUTGOING (i) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(ii) LED Type Phase indicator lamps for three phases set of three - 01 set (iii) Busbar chamber having insulated aluminium busbar, each suitable for 400 Amps for three phases and neutral -01 Set (iv) MCCB, 4 Pole,415V, 50HZ 100 Amps with rupturing capacity 16 KA-02 Nos
(v) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 16 KA-02 Nos (vi) Blank space for MCBs SPN - 12 Nos
-
-
-
Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, front openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing,wall mounting, dust and vermin proof, cubical type, fabricated from 2 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 400 Amps, prewired with suitable size of copper cable/insulated copper strip including fixing arragement at sitea with fastner on wall and connecting earth stripswire conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
2
-
-
Item No. 29.00 Contd...
(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ 200Amps microprocesor based with rupturing capacity 36 KA-01 No. (ii) Euroload On-load Changeover switch 200Amps, 4 pole, 415 Volts with handle (B) OUTGOING (i) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(ii) LED Type Phase indicator lamps for three phases set of three - 01 set (iii) Busbar chamber having insulated aluminium busbar, each suitable for 400 Amps for three phases and neutral -01 Set (iv) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 16 KA-02 Nos
(v) MCB, SPN, 230V, 50HZ 63 Amps with rupturing capacity 16 KA-10 Nos (vi) Blank space for MCBs SPN - 12 Nos
-
-
-
M&L for Bus Bar Panel of capacity 400 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 50x50x6 mm thick and 60cm height grouting in floor , 45 mm depth grouting with PCC 1:3:6 upto ground level all as specified and directed.
3
-
-
M&L for Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 40x40x6 mm thick and 60cm height grouting in floor , 0.45 mm depth grouting with PCC 1:3:6 upto ground level all as specified and directed.
3
-
-
Supply and fixing stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 16 mm dia including loop insulator suitable for 1.1 KV (size 65x90 mm) with clearance of hole 16 mm and MS stay plate size 230 x 230 x 6mm, stay clamps etc complete all as specified and directed.
7
-
-
M&L for galvanised stay strand 7/3.15 mm or 7/4.00 mm size with minimum tensile strength of 700 N/ Sqmm and conforming to IS : 2141-1979 complete all as specified & directed.
0.4
-
-
Re-Streaching of Aluminium reainforced condutor by opening from insulators and refixed with streached complete all as per directed
7
-
-
Supply and Laying and spreading of 40mm graded stone aggregate complete all as specified and directed.
90
-
-
M&L in replacement of stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 10 Sqmm 2 core. Make: Havells/Polycab/Finolex/Kalinga/Plaza
500
-
-
M&L for Digital Multifuction meter with selector switch to measure amphere, voltage frequency etc to be fixed in existing LT panel complete all as specified and directed.
5
-
-
M&L for current transformer of ratio 200/5 to be fixed in existing LT panel connecting to existing meter/new meter complete all as specified and directed.
2
-
-
M&L for current transformer of ratio 100/5 to be fixed in existing LT panel connecting to existing meter/new meter complete all as specified and directed.
2
-
-
Supply and fixing in replacement of MCCB 4 pole , 250 amp rating of 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
3
-
-
Supply and fixing in replacement of MCCB 4 pole , 200 amp rating of 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
3
-
-
Supply and fixing in replacement of MCCB 4 pole , 160 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
5
-
-
Supply and fixing in replacement of MCCB 4 pole , 100 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
7
-
-
Supply and fixing in replacement of MCCB 4 pole , 63 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
7
-
-
M&L LT line PVC spacers spiral type for two/three/four line (separator) complete all as specfied and directed.
200
-
-
M&L for Cutting /trimming of tree branches upto 80 mm girth along LT/HT OH electric lines which or growing /touching or falling on ACSR conductor /poles or near by sub stns etc at any height from GL and making sufficient clearance not less than 1.5 mtr from ACSR conductor/ poles/ structure and taking down the same on the ground carefully avoiding the damage of and removing to a distance including stretching of conductor as required where directed by Engr - in -charge. Note :- Tree cutting will be maintain for periodisity for three months depending upon the grougth of three branches.
250
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%