Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Jun 2024
Closing Date23 Jul 2024
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only the following spares / parts suitable for Air handling units repaired under respective Sch ‘A’ item No. 1.01 to 1.03 for servicing / overhauling of AHU complete all as specified and directed. (a) Pedestal bearing no NTN 205 J (Japan) or equivalent of make SKF /NBC complete all as specified and directed.

4

-

-

... More
(b) Pedestal bearing no NTN 206 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed

4

-

-

... More
(c) Pedestal bearing no NTN 207 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed

4

-

-

... More
(d) Pedestal bearing no NTN 211 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed.

4

-

-

... More
(e) Mild steel shaft pulley 8” dia, B section, double groove inner bore 32mm with suitable slot for key complete all as specified and directed

2

-

-

... More
(f) Mild steel shaft pulley 8” dia, B section, three groove inner bore 25mm with suitable slot for key complete all as specified and directed.

2

-

-

... More
(g) Mild steel shaft pulley 4” dia, B section, double groove inner bore 25 mm with suitable slot for key complete all as specified and directed.

2

-

-

... More
(h) Cast copper alloy gate valve 20mm nominal bore, screwed down high pressure, with crutch or butter fly handle complete all as specified and directed Make : Sant/Zoloto/Leader/BIR.

4

-

-

... More
(j) Cast copper alloy gate valve 25mm nominal bore, screwed down high pressure, with crutch or butter fly handlec omplete all as specified and directed Make : Sant/Zoloto/Leader/BIR Note (i) Cost element of removing unserviceable parts, fixing and testing of the new items/ parts is deemed to be included in the respective rates quoted by the contractor under respective Sch ‘A’ item No. 1 to 04 for servicing / overhauling of AHU. (ii) Contractor shall have no claim on account of variation of quantities of these items/non execution of any of the above items and contractor shall be paid for at as quoted rates only for the parts actually replaced.

4

-

-

... More
S&F ‘V’ belts of following cross section, pitch length & size including disconnection and taking down of ‘V’ belts from motors complete all as specified and directed, Make : Fenner / Hilton. (a) Cross section 17 x 11 mm & pitch length 4030 mm of size B-159

6

-

-

... More
(b) Cross section 17 x 11 mm & pitch length 2910 mm of size B-113

5

-

-

... More
(c) Cross section 17 x 11 mm & pitch length 1770 mm of size B-68

4

-

-

... More
(d) Cross section 17 x 11 mm & pitch length 1800 mm of size B-69

4

-

-

... More
(e) Cross section 17 x 11 mm & pitch length 2300 mm of size B-89

6

-

-

... More
(f) Cross section 17 x 11 mm & pitch length 1820 mm of size B-70

6

-

-

... More
(g) Cross section 17 x 11 mm & pitch length 1010 mm of size B-38

6

-

-

... More
(h) Cross section 17 x 11 mm & pitch length 2790 mm of size B-108

6

-

-

... More
(j) Cross section 22 x 14 mm & pitch length 3360 mm of size C-130

6

-

-

... More
(k) Cross section 22 x 14 mm & pitch length 2720 mm of size C-105

8

-

-

... More
Supply & fix in replacement the following filters suitable for Air handling units of air conditioning plants complete all as specified and directed by the Engineer-in-Charge (Make : Dyna, Tenacity, Airtech, Puromatic, Thermodyne, Spetam or equivalent make as approved by the GE) (a) Micro ‘V’ air filter nylon/fabric fibre, media of capacity 5 micron, 98% efficiency of size 610mm x 610mm x 305mm deep.

1

-

-

... More
(b) All as per item No 4.00 here-in-before but of size 610mm x 305mm x 305mm deep

1

-

-

... More
(c) Pre-air metallic air filter of 10 micron, 90% efficiency with GI sheet frame of size 600mm x 400mm x 48mm deep

1

-

-

... More
(d) All as per item No 4.02 here-in-before but of size 500mm x 400mm x 48mm deep

1

-

-

... More
(e) All as per item No 4.02 here-in-before but of size 610mm x 305mm x 50mm deep

1

-

-

... More
(f) All as per item No 4.02 here-in-beforebut of size 610mm x 610mm x 50mm deep

1

-

-

... More
(g) All as per item No 4.02 here-in-beforebut of size 610mm x 310mm x 50mm deep

1

-

-

... More
M&L for servicing /descaling of Hot water generator up to 170 KW 3 phase, 415 volts and callibration testing of all functional with including replacement of any minor defective parts such as bolts, nuts and screw etc complete all as specified & directed..

11

-

-

... More
Disconnecting and taking out existing unserviceable heater of 14 KW/3KW any description and in any position complete all as specified & directed.

26

-

-

... More
Supply and fix in repair and commissioning Hot Water Generator Set heating element 14 KW complete including flushing of pipe line and brazing as required all as directed for satisfactory operation of plant complete all as specified & directed. Make : As per sample / Daspas or equivalent make as approved by the GE

3

-

-

... More
Supply and fixing in replacement strip heater 3 KW, 230 volts fin type complete all as specified & directed. Make : Daspas or equivalent make as approved by the GE

4

-

-

... More
Supply and fixing in replacement of PCB for hot water generator as per existing of capacity upto 30KW complete all as specified & directed.. Make : RAPID COOL complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Supply and fixing in replacement of PCB as per existing for hot water generator of capacity above 30 KW and upto 63KW complete all as specified & directed. Make : RAPID COOL complete all as specified and directed by the Engr-in-Charge.

1

-

-

... More
Supply and fixing in replacement of PCB as per existing for hot water generator of capacity above 63 KW complete all as specified & directed. and upto 170 KW Make : KEPL complete all as specified and directed.

1

-

-

... More
Supply only MCB SP 6-32 Amps 240 Vols complete all as specified and directed.

25

-

-

... More
Supply only MCB SPN 16-32 Amps 240 Vols complete all as specified and directed.

25

-

-

... More
Supply and fixing in replacement of fan set of size suitable for up to 75 TR Air Cooled AC Plant with hub assembly sweep 1200 mm & 4 blades complete all as per sample all as specified and directed.

2

-

-

... More
M&L for de-scaling and cleaning of condenser, condensor pipe, water circulating pipe lines ,valves, condenser coil (heat Exchanger) to cooling tower, and cooling tower by circulating concentrated de-scaling solution (scale balaster -copper friendly chemical and neutralizer ) mixed with water in suitable proportion till the deposits/scale is removed to maintain required pressure, the chemical should be circulated through pump, cleaning the condenser and connected pipe and components of compressor by suitable size of drill rod fixing wire brush including dismantling and connecting all dismantled components in proper position after servicing / overhauling/greasing/cleaning and replacement of packing gasket 3mm thick, nuts, bolts with washer, testing of water line for leakage, complete all as specified and directed by Engineer-in-Charge for the following AC plants :- Note : Rates for scale blaster are not inclusive under quoted rate, Scale Blaster and neutralizer shall be measured and paid separately as supply only. (a) Capacity of (3x85 TR) Central AC plant water cooled (Make : Blue Star)

1

-

-

... More
(b) All as per item No15 here-in-before but Capacity of (3x52 TR) Central AC plant water cooled (Make : M/S Swastik Engineers)

1

-

-

... More
(c) All as per item No15 here-in-before but Capacity of (3x11 TR) Central AC plant water cooled. (Make : M/S Swastik Engineers)

1

-

-

... More
(d) All as per item No15 here-in-before but Capacity of (3x50 TR) Central AC plant water cooled. (Make :Blue Star)

1

-

-

... More
(e) All as per item No15 here-in-before but Capacity of (3x37 TR) Central AC plant water cooled. (Make Ramson Project Corporation)

1

-

-

... More
(f) All as per item No15 here-in-before but Capacity of (3x25 TR) Central AC plant water cooled..(Make : M/S Swastik Engineers).

1

-

-

... More
(g) All as per item No15 here-in-before but Capacity of Capacity of (3x65 TR) Central AC plant water cooled. (Make : Blue Star)

1

-

-

... More
(h) All as per item No15 here-in-before but Capacity of Capacity of (3x27 TR) Central AC plant water cooled. (Make : Blue Star).

2

-

-

... More
(k) All as per item No15 here-in-before but Capacity of Capacity of (3 x 38 TR) Central AC plant water cooled. (Make : Blue Star)

1

-

-

... More
(l) All as per item No15 here-in-before but Capacity of (3x26 TR) Central AC plant water cooled. (Make : Blue Star)

2

-

-

... More
(l) All as per item No15 here-in-before but Capacity of (3x35 TR) Central AC plant DX type water cooled. (Make : ACCEL)

1

-

-

... More
(l) All as per item No15 here-in-before but Capacity of (3x35 TR) Central AC plant DX type water cooled. (Make : VOLTAS)

1

-

-

... More
M&L for Servicing of existing cooling tower FRP type, of any description & in any position complete including dismantling all old connected parts/items line motor PVC filling, MS/GI pipe, sluice valve, stop valve, steel structure frame etc servicing, overhauling,cleaning, painting with one coat of paint (approved colour), painting of complete pipe line of entire plant by scrapping & preparation of old painted MS/GI pipe of plant with colour code as directed by Engr - in - Charge and marking arrow for indicating direction of flow are inclusive under quoted rate and fixing of serviceable parts in position, removing & replacement of defective/unserviceable parts with new parts, reassembling the cooling towers and connected parts/items fixied in original position for connecting to existing system and testing at site on full load to the entire satisfaction of the EIC complete all as specified and directed for the following capacity:- Note (i) The replacement of defective/non functional parts shall be measured and paid seperatly as `supply only' under appropriate items of sch `A' and fixing rate for new items are deemed to include under this item. (a) Cooling tower of plant capacity 10 - 50TR

2

-

-

... More
(b) Cooling tower of plant capacity above 50 and upto 100 TR

8

-

-

... More
(c) Cooling tower of plant Capacity above 100 and upto 200 TR

3

-

-

... More
Supply only PVC filling blocks of size as per sample suitable for cooling tower complete all as specified and directed.

600

-

-

... More
Supply and fixing in repair of Aluminium fan set of Colling Tower suitable for 10 to 50TR with hub assembly sweep upto1400 mm & 4 blades complete as per existing all as specified and directed.

1

-

-

... More
Supply and fixing in repair of Aluminium fan set of Colling Tower suitable for 10 to 50TR with hub assembly sweep upto 1600 mm & 4 blades complete as per existing all as specified and directed.

1

-

-

... More
Supply and fixing in repair of Aluminium fan set of Colling Tower suitable for 10 to 50TR with hub assembly sweep upto 1800 mm & 4 blades complete as per existing all as specified and directed.

1

-

-

... More
Supply and fixing of bottom waterline CI filter and replacement of strainer jalli including nuts bolts etc complete as per existing all as specified & directed of following size:- (a) 200mm

1

-

-

... More
(b) 100mm

2

-

-

... More
(c) 80mm

2

-

-

... More
Supply and fixing repair and replacement of rotary sprinkler with head cagin with frame and PVC header assembly of following capacity of cooling tower complete including PVC pipe of suitable size and length as required complete all as specified and directed of following size :- (a) up to 50 TR

2

-

-

... More
(b) Above 50 and upto 100 TR

2

-

-

... More
(c) Above 100 and upto 200 TR

2

-

-

... More
S&F PVC plate as per existing suitable for insertion of fillers of cooling tower as per sample complete all as specified and directed for the following Cap cooling towers :-

-

-

-

... More
(a) Upto 50 TR

2

-

-

... More
(b) Above 50 and upto 100 TR

4

-

-

... More
(c) Above 100 and upto 200 TR

2

-

-

... More
S&F PVC Nozzles of sizes 2 to 3 inch suitable for fixing in cooling tower complete all as specified and directed.

20

-

-

... More
Supply and fixing PVC float valve of size 25mm and model as per existing complete all as specified and directed.

15

-

-

... More
Supply and fixing Gun metal gate/globe valve of size 25 mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.

12

-

-

... More
Supply and fixing Gun metal gate/globe valve of size 20 mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.

8

-

-

... More
Supply and fixing PVC mesh for complete tower as per existing suitable for following cooling tower of capacity all as specified and directed :- (a) Upto 50 TR

2

-

-

... More
(b) Above 50 and upto 100 TR

6

-

-

... More
(c) Above 100 and upto 200 TR

3

-

-

... More
Supply only scale blaster-copper friendly De-scalling chemical as per sample (in 50 ltrs sealed packing) complete all as specified and directed

600

-

-

... More
Supply only neutralizer to neutralize the effects of scale blaster as per sample (in 50 ltrs sealed packing ) complete all as specified and directed.

600

-

-

... More
Supplying, laying, commissioning in replacement including testing M S Pipes of 200 mm bore size, heavy grade with all fittings / welding as required at site, laid in floors or fixed to walls / supports and ceilings for AC plants complete all as specified and directed.

18

-

-

... More
All as per item No 31 here-in-before but of size 150 mm bore

20

-

-

... More
All as per item No 31 here-in-before but of size 100 mm bore

25

-

-

... More
All as per item No 31 here-in-before but of size 80 mm bore

25

-

-

... More
Supply, laying , commissioning including testing in replacement of GI Pipe of Medium Grade of size 25 mm bore complete all as speicified and directed.

100

-

-

... More
Supplying, laying , commissioning including testing in replacement of cast iron butter fly valve as per sample of size 200 mm bore complete all as speicified and directed.

1

-

-

... More
All as per item No 36 here-in-before but of size 150 mm bore

2

-

-

... More
All as per item No 36 here-in-before but of size 100 mm bore

2

-

-

... More
All as per item No 36 here-in-before but of size 80 mm bore

3

-

-

... More
All as per item No 36 here-in-before but of size 65 mm bore

3

-

-

... More
Disconnecting, dismantling & taking up/down AC electric motors of any description and in any position from existing foundation of compressor/blowers/pumps/ cooling tower strip opening and dismantling of motor for servicing /overhauling, cleaning oiling/greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling motors, ensuring proper alignment of the motor with existing compressor / pumps/blower/cooling tower, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :- (a) 1 HP to 5 HP 1 Phase/3 Phase 50 Hz

6

-

-

... More
(b) 7.5 HP to 12.5 HP Three phase 50 Hz

12

-

-

... More
(c) 15 HP to 20 HP Three phase 50 Hz

6

-

-

... More
(d) 60 HP Three phase 50 Hz

2

-

-

... More
Disconnecting, dismantling & taking up/down pump set and monoblock pump sets of AC plant of any description and in any position from existing foundation, strip opening and dismantling of Pumps for servicing/overhauling, cleaning oiling/ greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling the pumps ensuring proper alignment of pump, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :- (a) 0.5 HP to 3 HP single phase 50 Hz

3

-

-

... More
(b) 5.0 HP HP Three phase 50 Hz

5

-

-

... More
(c) 7.5 HP HP Three phase 50 Hz

5

-

-

... More
(d) 10 HP to 12.5 HP Three phase 50 Hz

4

-

-

... More
(e) 15 HP to 20 HP Three phase 50 Hz Notes : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under respective item of overhauling and servicing mentioned here in before. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & from of pumps/ motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop & replacement of necessary unserviceable screws/nuts/bots/washers/ packing etc with new one (iv) Re-metaling of side cover of motor and machinery, polishing for housing of bearing all as required at site for smooth and noiseless movement of rotor impeller shall be measured and paid for separately under appropriate item of Schedule `A’. (v) Re-metaling to pump shaft, polishing and grinding and making to standard size to match with GM Bushes / Neck ring shall be measured and paid separately under appropriate item of Sch`A’

4

-

-

... More
Taking out & removing old burnt out windings and rewinding of electric motors of following sizes with existing size copper super enameled wire including insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc including testing and refixing to original position for the following capacities. (Note : Rates are inclusive of transportation , labour etc, complete. (a) 0.5 HP to 1.5 HP single phase 50 Hz

3

-

-

... More
(b) 2.0 HP to 3.0 HP Three phase 50 Hz

8

-

-

... More
(c) 5.0 HP Three phase 50 Hz

8

-

-

... More
(d) 7.5 HP Three phase 50 Hz

8

-

-

... More
(e) 10 HP to 12.5 HP Three phase 50 Hz

6

-

-

... More
(f) 15 HP Three phase 50 Hz

4

-

-

... More
(g) 20 HP Three phase 50 Hz

4

-

-

... More
(h) 60 HP Three phase 50 Hz

1

-

-

... More
Supply only ball Bearing/Roller Bearing of the following Sizes complete all specified and directed by the Engineer-in-Charge. (a) 6202Z

4

-

-

... More
(b) 6204Z

2

-

-

... More
(c) 6313Z

2

-

-

... More
(d) 6312Z

2

-

-

... More
(e) 6307Z

1

-

-

... More
(f) 6308Z

2

-

-

... More
(g) 6309Z

1

-

-

... More
(h) 6310Z

1

-

-

... More
Supply only gun metal bushes suitable for following capacity of pumps of any make/model :- (a) 02 to 05 HP Pump

2

-

-

... More
(b) 7.5 to 12.5 HP Pump

3

-

-

... More
(c) 15 to 20 HP Pump

2

-

-

... More
Supply only of MS star coupling , rubber coupling L – 190 for pump and Motor or as approved by GE. Note :- Fixing/ testing charges of these items are deemed to be included in the rates quoted by the contractor for respective Sch ‘A’ item.

3

-

-

... More
Supply only cast iron gland plate for pumps suitable for following capacity of pumps of any make/model. (a) 5 to 12.5 HP, three phase, 50 Hz

3

-

-

... More
(b) 20 HP, three phase, 50 Hz

3

-

-

... More
Supply only gland bolts made out of high carbon forged steel complete with nuts & washers suitable for following capacity of pumps of any make/model : (a) 5 to 12.5 HP, three phase, 50 Hz

30

-

-

... More
(b) 20 HP, three phase, 50 Hz

20

-

-

... More
Supply only pump shaft all as specified & directed by Engineer-in-Charge, suitable for following capacity of pumps of any make/model : (a) 5 to 12.5 HP, three phase, 50 Hz

2

-

-

... More
(b) 20 HP, three phase, 50 Hz

1

-

-

... More
Supply only of rotor motor shaft all as specified & directed by Engineer-in-Charge, suitable for following capacity of motor of any make/model:- (a) 5 HP, three phase, 50 Hz

2

-

-

... More
(b) 7.5 HP, three phase, 50 Hz

2

-

-

... More
(c) 10 HP, three phase, 50 Hz

2

-

-

... More
(d) 12.5 HP, three phase, 50 Hz

2

-

-

... More
(e) 20 HP, three phase, 50 Hz

2

-

-

... More
Supply only pump impeller CI suitable for following capacity of pumps of any make/model:- (a) 5 to 12.5 HP, three phase, 50 Hz

4

-

-

... More
(b) 20 HP, three phase, 50 Hz

2

-

-

... More
Disconnecting and taking down existing unserviceable terminal plate of any description and in any position supply and fixing terminal plate, 3 phase, six wire, bakelite, star / star delta connection as required at site with brass studs, nuts and washer complete all as specified and directed for the following capacity of motors : - (a) 1 HP to 3 HP

4

-

-

... More
(b) 5 HP to 10 HP

8

-

-

... More
(c) 12.5 HP to 20 HP

8

-

-

... More
(d) 60 HP

1

-

-

... More
Dismantling and taking down/removing of damaged fan blades of any description and in any position from electric motors all as directed and Supply and fixing Fan blades fabricated to shape and size of Zink Aluminum cast alloy as per sample for electric motor with key and key grove complete all as directed for the following capacity motors :- (a) 5 HP to 7.5 HP

4

-

-

... More
(b) 10 HP to 12.5 HP

3

-

-

... More
(c) 20 HP

4

-

-

... More
(d) 60 HP

1

-

-

... More
S&F of contactor MNX 18 Amp with 1 NO+1NC auxilary contacts complete all as specified and directed.

14

-

-

... More
S&F of contactor MNX 40 Amp with 1 NO+1NC auxilary contacts complete all as specified and directed.

22

-

-

... More
S&F of contactor MNX 32 Amp with 1 NO+1NC auxilary contacts complete all as specified and directed.

18

-

-

... More
Supply and fixing in repair of overload relay MN-2, 14-23Amp complete all as specified and directed.

16

-

-

... More
Supply and fixing in repair of overload relay MN-2, 9-15 Amp complete all as specified and directed.

25

-

-

... More
S&F in repair including testing of electronic timer, time range from 3 seconds to 120 seconds suitable for 240/415 volts 50 HZ complete all as specified and directed

12

-

-

... More
S&F in repair copper Lugs/terminal heavy duty of the following size complete all as specified and directed (a) 50 Sqmm

20

-

-

... More
(b) 35 Sqmm

20

-

-

... More
(c) 25 Sqmm

25

-

-

... More
(d) 16 Sqmm

25

-

-

... More
S&F in repair including testing of DOL motor starter 20 HP capacity, 415 Volts, 3 phase, 50 Hz AC supply, in sheet steel enclosure three phase with maximum relay range of 9-15A fixed on wall of appropriate size fixed with suitable MS nut bolts/screws complete all as specified and directed.

1

-

-

... More
Preventive maintenance & routine servicing of split AC of any type/size/make /model & capacity up to 3TR in any position / work shop as convenient indoor & out door unit by cleaning of dust from condenser,air filter, cooling coils by pressure pump , liquid line filter/capillary tube /expansion valve, refrigerent inlet /out let pipe by Nitrogen and Ethylene tri chloride(ETC),and checking of all electrical components and compressor etc. Replacement of minor parts such as nut, bolts, screws, washers, brazing, lugs etc and testing proper cooling all as directed. Note:- (i) The replacement of defective / nonfunctional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be issued by department under Sch B. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit.

290

-

-

... More
Preventive maintenance & routine servicing of Window type AC of any type/size/make /model & capacity at any position including cleaning & washing condenser assembly by chemical such as suction air filter & coil, brazing the discharge and suction line and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers incl replacment of unserviceable parts of capacity 1.5/2.0 TR of single phase AC etc and testing complete all as specified and directed. NOTE :- (i) The replacement of defective / nonfunctional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be measured and paid separately. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit.

50

-

-

... More
Supply only following items of Air conditioning split/window type AC of capacity 1.5/2/3TR of any make/model/ capacity including checking of defects and rectified. (a) Supply only in replacement with new Starting capacitor 80/100 mfd suitable for 240 Volts 50 HZ AC .

40

-

-

... More
Supply only new Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC

15

-

-

... More
Supply only new Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ AC

40

-

-

... More
Supply only new Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC

50

-

-

... More
Supply only new Running capcitor of 10 mfd suitable for 430 volts 50 HZ AC

50

-

-

... More
Supply only new Running capcitor of 1 to 2.5 mfd suitable for 240 volts 50 HZ AC

20

-

-

... More
Supply only new Running capcitor of 3 to 4 mfd suitable for 240 volts 50 HZ AC

35

-

-

... More
Supply only new PVC braded drain pipe of size 15 mm inner dia

90

-

-

... More
Supply only new PVC braded drain pipe of size 20 mm inner dia

80

-

-

... More
Supply only new Electronic sensing unit as per sample (PCB) with hand set suitable for PCB and display unit suitable for Split AC/Window AC 1.5/2.0 TR of capacity, model and make as per existing all as directed.

35

-

-

... More
Supply only new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR inverter type of capacity, model and make as per existing all as directed.

12

-

-

... More
Supply only new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR capacity Non inverter type, model and make as per existing all as directed.

14

-

-

... More
Supply only new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR cassete type of any model and make as per existing all as directed.

12

-

-

... More
Supply only new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for hot and cool type Split AC 1.5/2 TR of any model and make as per existing all as directed.

8

-

-

... More
Supply only new Air cooled copper condenser coil as per sample suitable for split type AC 1.5/2TR complete all as specified and directed.

12

-

-

... More
Supply only new Air cooled copper condenser coil as per sample suitable for window type AC 1.5/2TR complete all as specified and directed.

8

-

-

... More
Supply only with new Air cooled copper condenser coil as per sample suitable for split type AC 3TR complete all as specified and directed.

8

-

-

... More
Supply only new Air cooled copper condenser coil as per sample suitable for split type Cassete AC 3TR including complete all as specified and directed.

6

-

-

... More
Supply only new Electric fan motor as per sample suitable for out door unit 1.5/2 TR split AC Single Phase complete all as specified and directed. Make :- LG/Blue star/ Voltas or as per existing make of AC at site.

25

-

-

... More
Supply only new Electric fan motor as per sample suitable for out door unit 1.5/2 TR window AC Single Phase complete all as specified and directed at site. Make :- LG/Blue star/ Voltas or as per existing make of AC at site.

19

-

-

... More
Supply only new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Single Phase complete all as specified and directed at site. Make :- LG/Blue star/ Voltas or as per existing make of AC at site.

6

-

-

... More
Supply only new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Three Phase complete all as specified and directed at site. Make :- LG/Blue star/ Voltas or as per existing make of AC at site.

8

-

-

... More
Supply only new capillary tube of size as per sample suitable for split AC 1.5TR/2TR/3TR and window type AC of any make complete all as specified and directed.

150

-

-

... More
Supply only new Liquid line copper filter as per sample suitable for 1.5/2 TR split/window AC complete all as specified and directed.

25

-

-

... More
Supply only new Liquid line copper filter as per sample suitable 3 TR split AC complete all as specified and directed.

30

-

-

... More
Supply only new Over load Relay as per sample suitable for any type split type 1.5/2 TR Capacity complete all as specified and directed.

70

-

-

... More
Supply only new Over load Relay as per sample suitable for any type split type 3 TR Capacity complete all as specified and directed.

30

-

-

... More
Supply only new Condenser side fan blade as per sample suitable for existing Split type AC's of Capacity 1.5/2 TR complete all as specified and directed.

40

-

-

... More
Supply only new Condenser side fan blade as per sample suitable for existing Split type AC's of Capacity 3 TR complete all as specified and directed.

15

-

-

... More
Supply only PVC fan blower assembly as per sample for 1.5 /2TR window / split AC's Non inverter type any make as existing complete all as specified and directed.

15

-

-

... More
Supply only new Blower motor as per sample suitable for split type AC of 3 TR Capacity Non inverter as per existing make and model complete all as specified and directed.

18

-

-

... More
Supply only new Blower motor as per sample suitable for split type AC of 1.5/2 TR capacity inverter type as per existing make and model complete all as specified and directed.

8

-

-

... More
Supply only new Blower motor as per sample suitable for split type AC of 3 TR capacity inverter type as per existing make and model complete all as specified and directed.

6

-

-

... More
Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 1.5 / 2 TR Capacity complete all as specified and directed.

16

-

-

... More
Supply only new Swing Motor suitable for flapper of any type Split AC 3 TR Capacity complete all as specified and directed..

14

-

-

... More
Supply only new flapper suitable for Split AC as per sample for capacity 1.5 to 3 TR complete all as specified and directed.

17

-

-

... More
Supply only new PVC Grills as per sample and for any make window AC complete all as specified and directed..

16

-

-

... More
Supply only new Thermostate switch with knob 230 volts for Window AC complete all as specified and directed.

20

-

-

... More
Supply only new Check valve any dia for upto 3 TR capacity Split AC's as per sample complete all as specified and directed.

30

-

-

... More
Supply only new Expansion valve complete set as per sample suitable for 1.5 / 2 TR Spllit AC complete all as specified and directed.

24

-

-

... More
Supply only new Expansion valve complete set as per sample suitable for 3 TR Spllit AC complete all as specified and directed.

12

-

-

... More
Supply only new Ventury as per sample made of thermo-coal insulation suitable for Window AC complete all as specified and directed.

5

-

-

... More
Supply only new Pre-air filter made up of PVC for indoor unit as per sample of split AC suitable for any capacity make and description complete all as specified and directed.

39

-

-

... More
Supply only new Brass service valve of 5/8" dia with flare unit as per sample for split type AC complete all as specified and directed.

30

-

-

... More
Supply only new Brass service valve of 3/8" dia with flare unit as per sample for split type AC complete all as specified and directed.

35

-

-

... More
Supply only new Brass service valve of 1/2" dia with flare unit as per sample for split type AC complete all as specified and directed.

25

-

-

... More
Supply only new Brass service valve of 1/4" dia with flare unit as per sample for split type AC complete all as specified and directed.

30

-

-

... More
Supply only new Brass service dead nut suitable for any type of Acs as per sample complete all as specified and directed.

180

-

-

... More
Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 3/8" bore complete all as specified and directed.

90

-

-

... More
Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 5/8" bore complete all as specified and directed.

120

-

-

... More
Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 1/4" bore complete all as specified and directed.

90

-

-

... More
Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 1/2" bore complete all as specified and directed.

80

-

-

... More
Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample suitable for 1.5 TR Split Acs 230 volts of existing make complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

4

-

-

... More
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample and suitable for 2 TR Split Acs 230 volts of existing make complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

2

-

-

... More
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample and suitable for 3 TR Split AC Single Phase 230 volts of existing make complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

1

-

-

... More
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample and suitable for 3 TR Three Phase Split Acs 230 volts of existing make. complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

4

-

-

... More
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample and suitable for 1.5 TR Single Phase Window Acs 230 volts of existing make complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

6

-

-

... More
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample complete all as directed and suitable for 2 TR Single Phase Window Acs 230 volts of existing make complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

4

-

-

... More
Supply and fixing in replacement with new Rotary compressor as per sample and suitable for 1.5 TR Split AC Single phase 230 volts of existing make complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

14

-

-

... More
Supply and fixing in replacement with new Rotary compressor as per sample and suitable for 2 TR Split AC Single phase 230 volts of existing make complete all as specified and directedVaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

7

-

-

... More
Supply and fixing in replacement with new Rotary compressor as per sample and suitable for 3 TR Split AC Single phase 230 volts of existing make complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'.

3

-

-

... More
Supply and fixing in replacement with new Rotary compressor as per sample and suitable for 3 TR Split AC Three phase 230 volts of existing make complete all as specified and directed. Vaccumising and pressure testing is inclusive under preventive maintenance of unit under respective item.of schedule 'A'

12

-

-

... More
S&F in replacement with new out door cover at any location and floor made of MS Angle and GI Sheet with proper fixing screw to cover the entire out door unit as per sample, fixed on wall with neccessory grouting MS bolts,washer duly painted and making good of disturbed surfaces, suitable for installing outdoor unit of 1.5/2.0/3.0 TR AC complete all as specified and directed.

80

-

-

... More
Supply and fixing in replacement with new Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.

40

-

-

... More
S & F in replacement with new Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps complete all as specified and directed.

8

-

-

... More
Supply and fixing in replacement with new 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.

60

-

-

... More
Supply and fixing in replacement with new TPN / FP 32 Amp 415V 10KA 'B' curve miniature circuit breaker (MCB) and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.

14

-

-

... More
Supply and fixing in replacement with new power contactor MNX-12 of rating 12 amps four pole suitable for 415 volts for AC complete all as specified and directed.

14

-

-

... More
M & L necessary tools for finding leakage in condenser coil and rectify defects including welding/brazing as necessary by arranging N2 gas for checking and mutein gas for welding etc all as directed and testing for satisfactory operation of window/split type AC complete all as specified and directed.

65

-

-

... More
S & F in repair Voltage Monitor three phase protection device for three phase system having protection against High, Low Voltage , Single Phasing and Reverse phase sequence as per sample complete all as specified and directed.

18

-

-

... More
Repair / Maint of PCB of any type AC as per Sample suitable for 1.5 / 2/ 3 TR split / window AC complete all as specified and directed.

44

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.