Military Engineer Services Tender
... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Coronavirus COVID 19
Eprocure
Opening Date9 Jun 2018
Closing Date30 Jul 2018
Tender Amount₹ 29,80,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 59,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MES_197171_1Bid Award Id
ViewTender No
8287/04/E8 OF 2018-19Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking down the existing Old UNSV insulators and S/F new insulators all as specified and directed by Engineer-in-Charge are as under :-
-
-
-
... More
Disc type insulator Porcelain Vitreous 145mm high & 255 mm dia ball and socket type white brown or green 2 or 3 in series assembly for tension with tension clamps for conductors of working pressure 11 KV Complete all as specified and directed
3
-
-
... More
Pin type insulators, size 150 mm height & 150 mm dia Porcelain Vitreous brown / green / white 11 KV grade for supporting conductor/ jumpers.
3
-
-
... More
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of pipes/cable and getting out in hard / dense soil complete all as specified and as directed.
150
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm in hard / dance soil complete all as specified and directed by Engineer-in-Charge.
95
-
-
... More
Removing surplus excavated soil not exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
55
-
-
... More
M&L for sand cushioning to Cable in trenches with screened river washed sand and punning to provide required cover cable all as specified and directed Note:- Punned down thicknees of sand shall only be measured and paid.
30
-
-
... More
Supply and laying factory made un reinforced precast concrete cable covers of class LV type-1, flat size 250 x 150 x 40 mm all as specified & as directed.
Note :- Cable covers shall be laid in such a way that its length shall be perpendicular to the length of cable.
650
-
-
... More
Supply and laying factory made un reinforced precast concrete cable covers of class HV type-1, flat size 300 x 180 x 40 mm all as specified & as directed.
Note :- Cable covers shall be laid in such a way that its length shall be perpendicular to the length of cable.
1650
-
-
... More
Supply , laying & testing cable XLPE insulated screened PVC beaded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade 3 core complete all as specified for the following sizes:-
-
-
-
... More
HT cable 95 sq mm 3 core
50
-
-
... More
HT cable 120 sq mm 3 core
300
-
-
... More
HT cable 185 sq mm 3 core
50
-
-
... More
Material and labour in repair for GI tubing light grade of following size laid in trenches/ fixed to poles, walls etc as protection of cable all as specified
Make:- Tata / Jindal / Prakash Surya
-
-
-
... More
40mm dia
12
-
-
... More
80 mm dia
6
-
-
... More
100 mm dia
6
-
-
... More
On load filtration and dehydration of transformer oil of transformers installed in power house with filtering and dehydration machine, running the machine till the dialectic strength of minimum 45 KV in 2.5 mm gap achieved including testing complete all as specified and as directed.
400
-
-
... More
Supply and topping up transformer oil of dielectric strength 50 KV at 4 mm gap in transformers of various cap installed in various locations .Make of Transformer oil: Power Oil /Indian Oil. Notes : (a) New Transformer oil will be filled in the transformer only after filtration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
250
-
-
... More
Supply and fill silica gel in the breather of transformer all as specified and as directed.
2
-
-
... More
Replacement of old unserviceable breather with new breather assembly including silica gel in the breather all as specified and as directed.
1
-
-
... More
M&L for replacement of unserviceable gaskets of transformer with Neoprene sheet 6 mm thick, nut bolts washers and all other sundry materials required in repairs such as press board and other materials.
1
-
-
... More
Taking down / out transformer carefully from position at E/M installations by disconnecting all the connections carefully, lifting the transformer by crane and transporting the transformer safely to the repairers workshop and back after repair and placing in original position, connecting up and testing all as specified and as directed.
1
-
-
... More
Opening the top of the transformer step up / down , draining out transformer oil , cleaning the internal portion of tank, core and connections by mechanical means and force feeding of transformer oil and flushing out deposits, sludge etc, replacement of studs, bushings, washers etc and closing the top including new set of tropicalized gaskets complete all as specified and directed .
Notes : Studs, bushings shall be measured and paid under relevant items here in after
1
-
-
... More
M&L for Rewinding of transformer 250 / 315 KVA , Step up / down , HV Coils complete with copper wire ( As per existing gauge and size), re-assembling of newly wounded coils on core in position including re- insulation and testing on load complete all as specified & directed .
1
-
-
... More
M&L for Rewinding of transformer 250 / 315 KVA , Step up / down LV Coils complete with copper wire ( As per existing gauge and size), re-assembling of newly wounded coils on core in position including re- insulation and testing on load complete all as specified & directed .
1
-
-
... More
M&L for preparation of surfaces and painting of transformer by spraying with two coats of synthetic enamel paint of approved colour, patch work on transformer tank body including welding for closing of cracks and leakages etc all as specified & directed .
4
-
-
... More
S&F in repair of transformer LT bushing with brass rod / stud including cork sheet gaskets ,bolts complete all as specified & directed .
4
-
-
... More
S&F in repair of transformer HT bushing with brass rod / stud including cork sheet gaskets, bolts complete all as specified & directed .
3
-
-
... More
Supply and fix expulsion/drop out fuse unit with silverside brass contactors and fuse barrel suitable for 11 KV system triple pole of rating 200A complete with all fittings all as specified and as directed .
2
-
-
... More
Supply and fix gang operated device triple pole mechanically operated mounted on insulator & steel frame with operating mechanism worked from ground level , rating 200 Amp 11 KV complete all as specified and as directed
2
-
-
... More
M&L for lightning arresters expulsion type complete with all fittings, transmission class , discharge capacity 65 kilo amps suitable for 11KV on existing 2 pole/4 pole structures including taking down old unserviceable lighting arresters and connecting to the system complete all as specified and directed.
2
-
-
... More
Supply & fix the following items required during repair / maint of LT Panel at E/M installation :-
-
-
-
... More
MCCB 4 pole 415V, Adjustable type, 160 Amps with breaking Capacity 36 KA
1
-
-
... More
Dito all as above but 250 A
1
-
-
... More
S&F Epoxy insulators HT 11 KV suitable for providing spacing between bus bar and panels of 11000 Volt grade, shape as per existing at site all as specified & directed .
3
-
-
... More
S&F CT for HT 11 KV , of ratio 5/50/5/100 Amp as per existing , size and shape all as specified & directed .
1
-
-
... More
M&L for painting of steel tubular pole size 09 / 11 mtr long with two coats of aluminium paint including preparation of surface complete all as specified & directed .
8
-
-
... More
M&L for painting of poles of 2 Pole structures with two coats of aluminium paint including preparation of surface all as specified & directed .
6
-
-
... More
All as per sl Item No. 31 above but of 4 Pole structure.
2
-
-
... More
All as per sl Item No. 31 above but of 6/8 Pole structure.
1
-
-
... More
Supply and fixing new indicating lamp LED type suitable for HT / LT panel all as specified & directed .
3
-
-
... More
Supply and fix in repair digital type Ammeter as per existing for HT/LT panel all as specified and as directed.
1
-
-
... More
Supply and fix in repair digital voltmeter as per existing for HT/LT panel all as specified and as directed.
1
-
-
... More
Providing coloured sleeves as per existing sizes (Red/ Yellow / Blue etc) for jumper connections and connector on poles at E/M installations .
25
-
-
... More
M&L for Spray Painting to existing HT Panels, outer side with Super enamelled paint of approved make and colour and matching with the existing panel completely, including scrapping the rust and polishing, cleaning and drying the surfaces all as specified and directed for under mentioned panels :-
-
-
-
... More
VCB Panel / Bus coupler 11 KV
12
-
-
... More
VCB Panel 33 KV
3
-
-
... More
Relay panel 33 KV
3
-
-
... More
LT panel 440 Volts
1
-
-
... More
Supply and laying in trenches XLPE armd cable heavy duty 1100 volts grade of following sizes .
-
-
-
... More
LT Armd cable 2 & 10 Sq mm
60
-
-
... More
LT Armd cable 4 & 16 Sq mm
100
-
-
... More
S&F PVC insulated Twin flat multi stranded copper conductor cable of size 1.5 sq mm for replacement of connection from terminal box to light fitting all as specified and directed.
20
-
-
... More
Supply & fix 60W LED Flood Light with pressure die-cast housing with epoxy powder coated grey colour finish with IP 66 protection mounted on channels all as specified and directed
2
-
-
... More
Supply & fix integral LED street light luminaire comprising of epoxy powder coated housing enclosed with glass cover in frame 45 Watt , IP 65 protection including suitable size of GI bracket with clamps , Nuts , bolts & washers with two coat of aluminium paint over one coat of red oxide paints complete
4
-
-
... More
Supply & fix garden light LED fitting IP 65 protection 10 Watt including necessary connection with copper wire 1.5 Sq mm and properly fox with nuts, bolts & washers on PCC complete all as specified & directed .
2
-
-
... More
Servicing & testing on load of HT VCBs 11 / 33 KV and decarbonising complete contract points, meggering all HT insulators including oiling/greasing to moveable parts and replacement of burnet/unserviceable parts including checking of control wiring all as specified and as directed
Note:- Spares replaced shall be measured and paid under reverent items herein after .
15
-
-
... More
Supply only the following items complete all as specified and as directed .
-
-
-
... More
HBC fuse links HT 12 KV AC 10A / 20 A / 25 A
3
-
-
... More
HBC fuse links HT VTF for PTs 11 KV
3
-
-
... More
HT insulators 11 KV
3
-
-
... More
Shunt trip coil and closing coil 30 V DC suitable for 11/33 KV indoor/outdoor type VCB
3
-
-
... More
Servicing & testing on load of HT 33 KV control relay panel including primary current injection for its best tripping operation and checking of DC circuits complete all as specified and directed.
2
-
-
... More
Supply, testing and commissioning of master tripping relay system on 33 KV side including its control DC circuits wiring and connected to existing 33 KV control panel complete all as specified and directed
1
-
-
... More
Supply and fix in repairs out door type cable end termination joint heat shrinkable type for HT XLPE 11000 volt grade cable of size 3 core and connecting the cable with the load and testing complete all as specified and as directed for the following size of the cable
Make- Denson/ M Seal
-
-
-
... More
HT cable 185 sq mm 3 core
1
-
-
... More
HT cable 120 sq mm 3 core
1
-
-
... More
HT cable 95 sq mm 3 core
1
-
-
... More
Supply and fix outdoor type HT 11 KV cable jointing feeder pillar for inspection & meggering during faults , fabricated out of 3.15 mm thick CRCA sheet duly painted as per standard norms and practice , totally enclosed , powder coated mounted on channel of 75 X 40 ISMC , dust proof , vermin proof / water proof , both sides open able having provision for termination of two no's 11 KV HT cables with single Al bus bar PVC sleeved , air insulated colour coded of 400 Amp capacity , duly mounted on 11 KV epoxy insulators with two No's GI studs 16 mm thick for connection of GI earthing strip 32 / 6 mm including suitable size PCC platform of size 1.6 X 1.0 X 1.3 mtrs all as specified & directed . Note : Excavation shall be measured and paid separately under relevant item here in after
1
-
-
... More
M&L for Earthing complete with copper earth plate electrode 60 cm x 60cm x 3.15 mm thick and buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to Copper earth plate with copper strip of size 20 x 03 mm by means of bolts, nuts and washers of copper all as shown in electrical plate No. 3 connected to earthing test point complete, all as specified including PCC pit (1:3:6) type C-1 in cement concrete 40 mm thick precast RCC cover in (1:2;4) type B-1 reinforced with 8 mm dia MS round bar @ 75 c/c both ways with 01 No lifting handle of 12mm dia MS plain bar, GI pipe 32 mm dia light grade for copper strip protection and GI tubing 20 mm for watering including GI funnels with wire mesh including necessary earth work & excavation etc complete all as specified and directed by Engineer-in-charge.
Note:- Quantity of copper Strip/protection pipe beyound 7.5 Mtrs length will be measured separtely.
6
-
-
... More
M&L for Earthing complete with GI earth plate electrode 60 cm x 60cm x 6.0mm thick and buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to GI earth plate with GI wire of size 04 mm dia by means of bolts, nuts and washers of Steel all as shown in electrical plate No. 3 connected to earthing test point complete, all as specified including PCC pit (1:3:6) type C-1 in cement concrete 40 mm thick precast RCC cover in (1:2;4) type B-1 reinforced with 8 mm dia MS round bar @ 75 c/c both ways with 01 No lifting handle of 12mm dia MS plain bar, GI pipe 15 mm dia light grade for GI strip protection and GI tubing 20 mm for watering including GI funnel with wire mesh ikncluding necessary earth work & excavation etc complete all as specified and directed by Engineer-in-charge.
Note:- GI lead wire and protection pipe upto 7.5 mtrs is deemed to be included in the in the qouted rate.
(iii) Earthing required for External electrification shall also be measured under this item.
4
-
-
... More
M&L for copper strip size 20 X 3 mm thick complete all as specified & directed .
12
-
-
... More
M&L for earth continuity conductor or main earthing lead of 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or deawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required.
6
-
-
... More
M&L for cement concrete in foundation , filling and mass concrete Type D2 1:4:8 ( using 40 mm graded aggregate ) including form work complete all as directed .
4
-
-
... More
M&L for cement concrete 1:3:6 type C2 using 40mm graded as in foundation filling and mass concrete including form work complete all as specified.
10
-
-
... More
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick / concrete surface and finishing the surface even and fair all as specified and directed
100
-
-
... More
M&L for aluminium conductor steel reinforced complete all as specified & directed .
25
-
-
... More
S&F in repair out door type straight through joint heat shrinkable type for HT XLPE 11000 volt grade cable of size 3 core and connecting the cable including testing on load complete all as specified & directed for the following size of cable .
1
-
-
... More
HT cable 95 Sq mm
1
-
-
... More
HT cable 120 Sq mm
1
-
-
... More
HT cable 185 Sq mm
1
-
-
... More
Supply & fix in repair epoxy bus bar supporter for VCB 11 KV all as specified & directed
1
-
-
... More
Supply & fix in repair heater 230 Volt , single phase for HT VCB 11 KV all as specified & directed
1
-
-
Evaluation Notes How It Works ?