Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Jan 2024
Closing Date22 Feb 2024
Tender Amount₹ 26,25,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
One light point/fan point controlled by one switch.

340

-

-

... More
One switch socket combination out let 5 Amps on independent board.

95

-

-

... More
One Call bell Point Controlled by one bell Push.

12

-

-

... More
One socket out let 5 Amps on the same board with other switches.

90

-

-

... More
All as per item No. 3 above but on surface PVC rigid non metalic conduit of size 19 mm/casin-caping as required, for One light point/fan point/socket outlet 5 Amps independent point controlled by one switch.

135

-

-

... More
All as per item No. 3 above but drawn into the existing conduit as required, for One light point/fan point/socket outlet 5 Amps independent point controlled by one switch.

160

-

-

... More
All as per item No 3 above but with 2.5 sqmm PVC insulated multi stranded copper conductor and 2.5 sqmm PVC insulated multi stranded copper conductor as earth continuity conductor for one socket outlet 15 Amps on independent board.

110

-

-

... More
Supply & Fixing Modular type Switch single pole 6 Amps one way complete all as specified and directed.

363

-

-

... More
Supply & Fixing Modular type Switch single pole 16 Amps one way complete all as specified and directed.

105

-

-

... More
Supply & Fixing Modular type socket out let 2 in 1, 6 Amps complete all as specified and directed.

105

-

-

... More
Supply & Fixing Modular type Socket out let 2 in 1, 6/16 Amps complete all as specified and directed.

185

-

-

... More
Supply & Fixing Modular type Bell Push single pole 6 Amps one way complete all as specified and directed.

12

-

-

... More
Supply & Fixing Bell, AC, Ding Dong type 230 Volt complete all as specified and directed.

12

-

-

... More
Supply & Fixing Fan step type Regulator modular type, 120 watts, 230 Volt complete all as specified and directed.

80

-

-

... More
Supply & Fixing Ceiling Rose Surface PVC type 65 x 50 mm two to three terminals complete all as specified and directed.

440

-

-

... More
Supply & Fixing Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as directed.

95

-

-

... More
Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 4 way, TP & N, double door type, 440 Volt, suitable for MCB incomer complete all as specified and directed.. (Note : MCBs will be Measured separately)

6

-

-

... More
Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 8 way, SP & N, double door type, 240 Volt complete all as specified and directed. (Note : MCBs will be Measured separately)

12

-

-

... More
S&F in repairs Single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed.

20

-

-

... More
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB), TPN, 40 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed.

6

-

-

... More
Supply and fixing 240V 10KA 'C' curve miniature circuit breaker (MCB), SPN, 32 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed.

12

-

-

... More
Supply and fixing 240V 10KA 'C' curve miniature circuit breaker (MCB), SP, 6-32 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed.

144

-

-

... More
M&L for wiring with four single core, multi stranded, PVC insulated, 1100 Volt grade, FRLS, cable with copper conductor of size 6 Sq mm in and including/drawing through through rigid non metalic PVC conduit including continuous PVC insulated copper conductor single core earth continuity conductor of size 6 Sqmm connected common earth. (Note :- 4x 6 Sq mm conductor cable, 1 x 6 Sq mm conductor earth continuity cable & PVC conduit shall be measured as one unit length)

180

-

-

... More
M&L for wiring with two single core, multi stranded, PVC insulated, 1100 Volt grade, FRLS, cable with copper conductor of size 6 Sq mm in and including/drawing through rigid non metalic PVC conduit including continuous PVC insulated copper conductor single core earth continuity conductor of size 6 Sqmm connected common earth. (Note :- 2x 6 Sq mm conductor cable, 1 x 6 Sq mm conductor earth continuity cable & PVC conduit shall be measured as one unit length)

385

-

-

... More
Supply and fix in repairs MCCB, with sheet steel enclosure, AC, 415 V, four Pole, 100 Amps, 25 KA complete all as specified and directed.

3

-

-

... More
S&F in repairs Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB upto 63 Amps, 415 Volt all as specified and directed.

1

-

-

... More
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed/surface type, as directed, with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.

145

-

-

... More
Supply and fix LED tube light fitting box type 20 watts, 2000-2200 luminaire with poly carbonate LED upto 2100 lumin tube rod with in built reflector of same make, connecting cable three core PVC insulated and PVC sheathed copper flexible cable of size 16/0. 20mm with two Nos. MS bracket on wall including hanging arrangment and necessary fixing arrangement complete all as directed.

499

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI earth wire of size 4 mm dia from earth plate to body of the equipment by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15 mm bore GI light grade pipe for protection of earth lead from earth plate (6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.

11

-

-

... More
Taking down old unserviceable Sub main wiring with aluminium/copper conductor, any type/size complete with/without conduit and remove from site all as directed.

565

-

-

... More
Taking down old unserviceable DBs/Main switches any type/size complete with all accessories and remove from site all as directed.

18

-

-

... More
Supply fixing/connecting Static electronic electric energy meter, three phase, 415 volts AC, 50 Hz, of capacity 05 to 30 Amps, class 1.0 accuracy with LCD display including connecting the meter in the existing electrical system/cables and seal by means of sealing wire and lead including disconnecting/taking down u/s burnt energy meters from existing boards/boxes, deposit to E/M store complete all as directed. (Note : (a) Meter reading record shall be maintained before and after replacement.(b) Dismantled u/s energy meter shall be deposited to E/M store yard.)

2

-

-

... More
Supply fixing/connecting Static electronic electric energy meter, Single phase, 230 volts AC, 50 Hz, of capacity 10 to 60 Amps, class 1.0 accuracy with LCD display including connecting the meter in the existing electrical system/cables and seal by means of sealing wire and lead including disconnecting/taking down u/s burnt energy meters from existing boards/boxes, deposit to E/M store complete all as directed. (Note : (a) Meter reading record shall be maintained before and after replacement.(b) Dismantled u/s energy meter shall be deposited to E/M store yard.)

10

-

-

... More
Schedule of credit amount of Rs. 37,637.50 to be deducted during AOC.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.