Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jul 2024
Closing Date10 Sep 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_663562_1Bid Award Id
ViewTender No
GE(MCTE)/MHOW/43(T) OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removing surplus excavated soil material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
279.5
-
-
... More
M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified directed.
(Note : Punned thickness of sand shall be measured)
279.45
-
-
... More
M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified directed.
26
-
-
... More
Taking down damaged PCC/ steel pole/ strut of any size all as specified and directed.
8
-
-
... More
M&L for steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws type 410, SP-31 (9 mtrs long), errected to truely vertical position, painting externaly embedded portion in PCC with black bitumenous paint and externally exposed to surfaces with aluminium paint in two coats, making five alternate strips 30cm wide with black and yellow paint in two coats, marking MES number with black paint complete all as specified and directed. (Note : Excavation and PCC will be measured and paid for separately under respective items of this schedule)
8
-
-
... More
M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) as in base, foundation filling of the pole, all as specified and directed.
0.43
-
-
... More
M&L for PCC (1:3:6), type C2 (using 40mm graded crushed stone aggregate) as in coping for poles, incl. formwork etc all as specified and directed.
4.06
-
-
... More
M & L for PCC (1:2:4), type B1 using (20mm graded crushed stone aggregate) as in coping of poles including necessary use and waste of form work and finishing exposed surfaces even and smooth complete all as specified and directed.
0.65
-
-
... More
Supply & Fix in replacement SMF Battery 2V/1OO AH as per existing site Make : Exide, Model NO- UPST 100 all as directed by Eng-in-charge.
15
-
-
... More
Supply & Fix in replacement SMF Battery 2V/3OO AH as per existing site Make : Exide, Model NO- UPST 300 all as directed by Eng-in-charge.
16
-
-
... More
M&L for treatment of existing high resistance earthing pit by pouring of salt water solution made of 20 ltrs of water and 5 Kg of salt in the trench to be prepared all around the existing earth pit with radious 60 cm from the centre of the earth pit to the centre of the trench with a depth not less than 30 cm below ground level all as directed and specified by the Engr-in-charge and levelling/ returning filling of earth surface.
45
-
-
... More
Dehydration of HV/EHV grade transformer oil minimum three cycles to achieve di electric strength not less than 40 KV for 1 minute with 2.5mm Gap as per IS - 335 - 1983 for EHV grade including topping up with new transformer oil all as directed.
Note:- (i) Centrifuging Machine with all T&P & testing machine of oil, required for dehydration shall be arranged by contractor.
(ii) Oil required for topping up the transformer will be measured & paid separately
13000
-
-
... More
Supply and filling (topping up) of transformer oil EHV as per IS 335 of 1983 Part-II after dehydration & testing complete all as specified and directed.
1680
-
-
... More
Supply and errecting LT Panel outdoor type (CPRI approved and make as per list of make) mounted and fixed with PCC foundation, made out of MS sheet factory assembled & factory fabricated out of 3.15mm thick sheet steel with suitable size MS angel frame duly spray painted with two coats of gray synthetic enamel paint over one coat of red oxide zinc chrome primer after preparatiion of surface, with required civil works & with and including 4 Nos Copper bus bars 800 Amps with suitable size porcelain insulators & wiring with copper cable of suitable size, connecting including indicating lamp LED type for each phase, incl in built industiral type locking arrangement, front operated and back openable incl necessry arrangement for fixing with suitable clamps, nuts & bolts etc. The panel pre wired with PVC insulated copper conductor danger notice board, feeders marked, and testing & commissioning, complete consisting of the following (Make : Indoasian/ Power system and control/ Shalabh (India) Industries/ CPRI Approved (Locally Available):-
2
-
-
... More
(a) MCCB 4 pole 415 Volts 50Hzs 400 Amps 36 ka repturing capacity - 01 No (incoming)
(b) MCCB 4 pole 415 Volts 50Hzs 63 Amps 25 ka repturing capacity - 05 Nos (outgoing)
(c) ON / OFF LED Type indication lamp with toggle switch - Set of 03
(d) Voltmeter (0-500V) digital type with selector switch
(e) Ammeter (0-400 Amps) digital type with CT's and selector switch
-
-
-
... More
S&F MCCB, TPN, fixed thermal and fixed magnetic, 415 Volts, including taking out old unserviceable MCCB from existing panel of any type and make complete of following sizes :-
-
-
-
... More
(a) 40 Amps 16 kA
3
-
-
... More
(b) 63 Amps 16 kA
4
-
-
... More
(c) 100 Amps 16 kA
8
-
-
... More
(d) 125 Amps 25 kA
6
-
-
... More
(e) 150 Amps 25 kA
4
-
-
... More
(f) 200 Amps 25 kA
5
-
-
... More
(g) 250 Amps 25 kA
5
-
-
... More
(h) 320 Amps 36 kA
4
-
-
... More
(j) 400 Amps 36 kA
3
-
-
... More
Taking out old unserviceable underground cable heavy duty armoured with aluminum conductor of any size and all as specified and directed.
4350
-
-
... More
Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, multi stranded 1100 volts grade, laid in trenches, fixed on poles/ walls or passing through pipes including provision of necessary lugs and glands & making necessary connection complete all as specified and directed for the following:- (Note:- excavation and earth work, cable protection sand cushioning will be measured and paid seperately)
-
-
-
... More
(a) 10 Sqmm, 2 core.
700
-
-
... More
(b) 16 sqmm, 4 core
600
-
-
... More
(c) 25 Sqmm, 3 1/2 core
500
-
-
... More
(d) 35 Sqmm, 3 1/2 core
500
-
-
... More
(e) 50 Sqmm, 3 1/2 core
400
-
-
... More
(f) 70 Sqmm, 3 1/2 core
300
-
-
... More
(g) 95 Sqmm, 3 1/2 core
300
-
-
... More
(h) 120 Sqmm, 3 1/2 core
300
-
-
... More
(j) 150 Sqmm, 3 1/2 core
300
-
-
... More
(k) 185 Sqmm, 3 1/2 core
250
-
-
... More
(l) 240 Sqmm, 3 1/2 core
200
-
-
... More
S&F GI tubing, light grade, ISI marked 80mm bore pipe laid in trenches/ duct or in road crossing or fixed to wall/ poles for protection of cable incl taking out old pipe of any grade complete all as specified and directed.
24
-
-
... More
All as per item No.41 above but 50mm bore pipe.
36
-
-
... More
All as per item No.41 above but 40mm bore pipe.
30
-
-
... More
M&L for painting of existing old steel tubular poles 9 / 11 m long with cross arms with two coats of aluminium paint of approved make after preparation of surfaces, making five alternate strips 30cm wide with black and yellow paint above GL/plinth and marking MES No with black paint complete all as specified and directed.
240
-
-
... More
M&L for painting to old chain link fencing and steel sections post with two coats aluminum paint over a coat of aluminium red-oxide complete including preparation of old steel or iron surfaces all as specified and directed.
600
-
-
... More
Cutting the existing bituminous road for passing of UG cable in road crossing and making good the disturbed surface of road to its original specification complete all as specified and directed.
12
-
-
... More
Cutting, trimming and prunning of trees/ tree branches of any girth all around existing LT over head lines/ surrounding street light and flood fitting including cleaning the area beneath the LT overhead lines and removing the debris from the site and depositing where directed.
120
-
-
... More
M&L for cleaning the area including uprooting of weeds/ grass and removing creepers from fencing or poles/ posts and brooming the complete area of sub station around panels, transformers and four pole structures all as specified & directed.
1500
-
-
... More
Taking down unserviceable/ burnt out MCB from existing LT Panel board duly disconnected all electrical connection & Supply and fixing new MCB SP 6-32 Amps, incl making necessary cable connection complete all as specified and directed.
60
-
-
... More
Taking down unserviceable/ burnt out MCB from existing LT Panel board duly disconnected all electrical connection & Supply and fixing MCB 63 Amps TPN, incl necessary cable connection complete, all as specified and directed.
27
-
-
... More
Supply & laying or fixing 1100 volts grade havey duty 4 sqmm twin core flat/ circular PVC insulated aluminium conductor served with an inner shething of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtrs apart.
180
-
-
... More
All as per item No.51 above but 6 Sqmm 2 core
180
-
-
... More
All as per item No.51 above but 10 Sqmm 2 core
180
-
-
... More
Supply and jointing LT kit, heat shrink type suitable for 1100 V, XLPE, UG aluminum conductor cable of size 25 to 50 Sqmm 3.5 core and testing after jointing all as directed.
3
-
-
... More
All as per item No.54 above but 70 to 95 sqmm dia
4
-
-
... More
All as per item No.54 above but 120 to 240 sqmm dia
3
-
-
... More
Supply and fixing cable route indicator, made of MS sheet of size 200mm x 150mm x 3mm thick, spot welded with angle iron of size 40 x 40 x 5mm thick, 750mm long embedded in PCC (1:2:4) type B-2 (using 40mm graded crushed stone aggregate) block 30cm x 30cm x 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint showing size of cable HT/ LT complete all as specified & directed.
12
-
-
... More
M&L for painting of old RCC poles cross arms after preparation of old surfaces with two coats of synthetic enamel paint of approved colour incl making alternate strips of black and yellow colour of 30 cm width each above the top of coping/ GL and marking MES No with black paint complete all as specified and directed.
38
-
-
... More
M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x 6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI strip 32mm x 6mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length, provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts, bolts, earthing shall be done all as per shown electrical plate No 5 of SSR Part-I Including neccessary excavation in disintergratedand hard soil and 20mm dia GI pipe with funel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge.
4
-
-
Evaluation Notes How It Works ?