Military Engineer Services Tender

... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date4 Mar 2025
Closing Date31 Mar 2025
Tender Amount₹ 1,45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm and testing on completion including taking out old unserviceable cable jointing kit complete all as directed.

14

-

-

... More
Supply, Installation, testing and commissioning Outdoor Type Compact Sub- Station (CSS) having 11 KV, 630A VCB, 100 KVA Copper Wound Off-Circuit Transformer & LT Side comprising of the following below mentioned accessories complete all as specified and as directed:- (a) HT Section :- 11kV, 630A, Horizontal Draw Out VCB with Manual/230V AC Motor Operated Spring Charging Mechanism with 24V DC Closing /Opening Shunt trip coils, Aux. Switch, Mechanical On/Off Push Button, mechanical Operating Counter with metering 1 No CT, PT, IDMT, Cubical Auxiliary Relay, 8 Window Annunciator Model No. SI-801, Battery Power Pack with 7AH Battery & in built charger for 24V Circuit. (b) Transformer Section :- 100 KVA, 11/0.433 KV, Copper Wound Step Down “BIS Marked & BEE Star Labelled” Transformer having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI 1 No & Marshalling Box. as per IS-1180:2014 EEL- 2 with amendment no.- 1,2,3 & 4 Formerly EEL- 3 (till 30.3.2022) Losses @50% Load - 435W, Losses @100% Load - 1500W

2

-

-

... More
(c) LT Section :- LT Panel comprising of LV Side Incomer – 01 no. 200 Amp 4 Pole 25KA MCCB with thermal magnetic based release with O/L & S/C Protection.- RYB Indication - Ammeter -Voltmeter (d) APFC Section :- APFC Panel (i) 60 KVAR Capacitor bank with suitable MCB/MCCBs and Contactors MS Steel Sheet enclosure suitable for Outdoor Installation with MS channels (Base) - 01 Set (ii) Provision for receiving Incoming and Outgoing cables through Bottom entry, Excluding Termination Kit and Glands - 01 Set

-

-

-

... More
Supply, Installation, testing and commissioning Outdoor Type Compact Sub- Station (CSS) having 11 KV, 630A VCB, 315 KVA Copper Wound Off-Circuit Transformer & LT Side comprising of the following below mentioned accessories complete all as specified and as directed:- (a) HT Section :- 11kV, 630A, Horizontal Draw Out VCB with Manual/230V AC Motor Operated Spring Charging Mechanism with 24V DC Closing /Opening Shunt trip coils, Aux. Switch, Mechanical On/Off Push Button, mechanical Operating Counter with metering 1 No CT, PT, IDMT, Cubical Auxiliary Relay, 8 Window Annunciator Model No. SI-801, Battery Power Pack with 7AH Battery & in built charger for 24V Circuit. (b) Transformer Section :- 315 KVA, 11/0.433 KV, Copper Wound Step Down “BIS Marked & BEE Star Labelled” Transformer having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI 1 No Marshalling Box.as per IS-1180:2014 EEL- 2 with amendment no.- 1,2,3 & 4 Formerly EEL- 3 (till 30.3.2022) Losses @50% Load - 955W, Losses @100% Load - 2750W

1

-

-

... More
(c) LT Section :- LT Panel comprising of LV Side Incomer – 01 no. 630 Amp 4 Pole 35KA MCCB with thermal magnetic based release with O/L & S/C Protection. - RYB Indication - Ammeter -Voltmeter (d) APFC Section :- APFC Panel (i) 200 KVAR Capacitor bank with suitable MCB/MCCBs and Contactors, Mild Steel Sheet enclosure suitable for Outdoor Installation with MS channels (Base) - 01 Set (ii) Provision for receiving Incoming and Outgoing cables through Bottom entry, Excluding Termination Kit and Glands - 01 Set

-

-

-

... More
Supply, Installation, testing and commissioning Outdoor Type Compact Sub – Station (CSS) having 11 KV, 630A VCB, 500 KVA Copper Wound Off-Circuit Transformer & LT Side comprising of the following below mentioned accessories complete all as specified and as directed:- (a) HT Section :- 11kV, 630A, Horizontal Draw Out VCB with Manual/230V AC Motor Operated Spring Charging Mechanism with 24V DC Closing /Opening Shunt trip coils, Aux. Switch, Mechanical On/Off Push Button, mechanical Operating Counter with metering , 1 No CT, PT, IDMT, Cubical Auxiliary Relay, 8 Window Annunciator Model No. SI-801, Battery Power Pack with 7AH Battery & in built charger for 24V Circuit.

1

-

-

... More
(b) Transformer Section :- 500 KVA, 11/0.433 KV, Copper Wound Step Down “BIS Marked & BEE Star Labelled” Transformer having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI, 1 No & Marshalling Box. as per IS-1180:2014 EEL- 2 with amendment no.- 1,2,3 & 4 Formerly EEL- 3 (till 30.3.2022) Losses @50% Load - 1430 W Losses @100% Load - 4100 W (c) LT Section :- LT Panel comprising of LV Side Incomer – 01 no. 800 Amp 4 Pole 36 KA MCCB with thermal magnetic based release with O/L & S/C Protection. - RYB Indication - Ammeter -Voltmeter

-

-

-

... More
M & L, in replacement, earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 mtrs as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.

14

-

-

... More
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.

11

-

-

... More
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.

5

-

-

... More
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed.

6

-

-

... More
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be considered for payment purpose)

3.24

-

-

... More
Supply and laying un-reinforced precast concrete cable covers, Class HV type-1, flat, size 300 mm x 180 mm x 40 mm, complete all as specified and as directed.

1350

-

-

... More
Schedule of credit amount of Rs 13,851.00 to be deducted during AOC

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.