Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Oct 2024
Closing Soon16 Nov 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling & taking down of existing worn out / unserviceable GI wire of any description/size & in any position from existing LT/HT Lines including cradle guard wires all as specified & directed.

1

-

-

... More
Material and labour for supplying, stringing and fixing GI continuous GI earth wire of size 4 mm / 3.15mm dia on LT/HT poles as in cradle guards / earth wires etc. including binding complete all as specified & directed.

1

-

-

... More
Dismantling & taking out of old existing unserviceable steel & iron items from poles such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description and in any position from LT over head line poles/ street light poles complete all as specified & directed by Engineer -in-Charge.

1.5

-

-

... More
Fixing Only old fabricated mild steel structure such as cross arms, bracing, supports, clamps and back plate including nuts, bolts & washers on LT over head line poles/ street light poles complete all as specified & directed by Engineer -in-Charge.

1

-

-

... More
Supply, fabrication and fixing for mild steel structure such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description on LT over head line poles/ street light poles complete all as specified & directed by Engineer -in- Charge.

0.5

-

-

... More
Dismantling and taking down existing serviceable/unserviceable/ de-shaped/worn out LT/HT steel tubular / PCC pole of any shape, size & height including demolition of existing PCC foundation complete all as specified and directed.

12

-

-

... More
Supply and erecting steel tubular swaged pole (410 SP-31) 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole complete all as specified and dircetd.

10

-

-

... More
M&L for PCC (1:3:6 ) type C-2 ( using 40 mm graded stone aggregates ) as in sub base, foundation etc. complete all as specified and directed.

4

-

-

... More
M&L for PCC (1:2:4 ) type B-1 with20 mm graded stone aggregates for coping of poles with all necessary form work complete all as specified and directed.

0.5

-

-

... More
M&L for PCC (1:4:8 ) type D-2 with 40 mm graded stone aggregates for foundation of pole of complete all as specified and directed.

1.5

-

-

... More
M&L for stay assembly comprising of 16 mm dia, 1.80 meter long galvanized stay rod, having 7/3.15mm GI stay wire stranded and 230mm x 230mm x 6mm thick stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/ accessories like loop type insulator, stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) including taking down and dismantling old unserviceable stay assembly etc. complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for stay assembly comprising of 20 mm dia, 1.80 meter long galvanized stay rod, having 7/3.15 mm GI stay wire stranded and 230mm x 230mm x 6mm thick stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/ accessories like loop type insulator, stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) including taking down and dismantling old unserviceable stay assembly etc. complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT/HT poles all as specified & directed.

147

-

-

... More
Fixing Only old Insulators of any shape, size in any position including nuts, bolts, washers and all connected accessories as specified and directed.

30

-

-

... More
Supply and fixing pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut, 100mm height and 65mm dia suitable for working pressure up to and including 1100 volts grade of LT poles complete all as specified.

30

-

-

... More
All as per item No 18 here-in-before but for isulator 150 mm hight, 150 mm dia for 11000 volts grade., HT poles.

30

-

-

... More
Supplying & Fixing Shackle type 100mm height and 115 mm dia insulator, porcelain, vitreous, white, brown or green including galvanized mild steel strap 31mm X 5mm, insulator bolts 14mm dia with suitable washers and nut, suitable for working pressure up to & including 1100 volts, fixed on LT poles complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
M & L Disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly for tention with tention clamps for conductors, working pressure 11000 volts on HT poles complete all as specified and directed.

27

-

-

... More
Dismantling & Taking down Old Anti climbing devices and Supply and Fixing for Anti climbing devices, comprising 2.24mm dia galvanized steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 meter clamped and properly secured all as specified directed. Note: Clamps shall be measured and paid separately

0.5

-

-

... More
Dismantling and taking down existing unserviceable lightening arrestor of any capacity and any description and Supply, fixing, commissioning & testing of transmission class lightening arrestor 3300 Volt of Discharge capacity 65 KA NDC confirming to EC-99 -41/1990 including brackets, clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Disconnecting and taking down from poles existing street light fittings, bracket, nut-bolt and connected items of any type or any watt and size complete all as specified and directed.

12

-

-

... More
S&F ENDURA PULSE LED Street Light MADE UP of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP 66 protection and impact resistance of IK07. 60 W including GI light grade pipe bracket of suitable shape 1.5 mtr long and connecting cable 1.5 sqmm 3 core copper conductor from light fittings to OH line and PVC conduit pipe 15 mm bore heavy duty ISI marked duly clamped with pole at 2 places complete all as specified and directed

12

-

-

... More
Disconnecting, taking out and removing old existing unserviceable/ repairable underground, LT cable of any description and in any position complete including taking down protection pipe, bricks covers etc. all as specified and directed by the Engineer-in-Charge for the following sizes. Note : Excavation /earth work shall be measured and paid separately under relevant items of Sch.

-

-

-

... More
(a) 10 Sqmm to 25 Sqmm any core

1100

-

-

... More
(b) 35 Sqmm to 70 Sqmm 3½ core

450

-

-

... More
(c) 185 Sqmm to 300 sqmm 3½ core

110

-

-

... More
Laying only, jointing, commissioning and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any type and any make laid in trenches/ducts, floors, fixed to walls/ Poles etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-.

-

-

-

... More
(a) 10 Sqmm to 25 Sqmm any core

200

-

-

... More
(b) 35 Sqmm to 70 Sqmm 3½ core

150

-

-

... More
(c) 185 Sqmm to 300 Sqmm 3½ core

50

-

-

... More
Supply, laying, jointing and testing XLPE / PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description, laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-

-

-

-

... More
(a) 10 Sqmm 2 Core

400

-

-

... More
(b) 16 Sqmm 2 Core

300

-

-

... More
(c) 25 Sqmm 4 core

200

-

-

... More
(d) 35 Sqmm 3½ core

200

-

-

... More
(e) 50 Sqmm 3½ core

100

-

-

... More
(f) 240 Sqmm 3½ core

30

-

-

... More
(g) 300 Sqmm 3½ core

30

-

-

... More
Excavation in trenches in soft & loose soil not exceeding 1.5 meter deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.

650

-

-

... More
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.

490

-

-

... More
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.

415

-

-

... More
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.

235

-

-

... More
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed by Engineer-in-Charge.

8

-

-

... More
Laying only old retrieved serviceable bricks/ cable covers for cable protection with axis of the bricks/ cable cover perpendicular to the axis of the cable of any description as obtained from dismantling of the cable complete all as specified and directed by the Engineer-in-Charge.

5.3

-

-

... More
Disconnecting, dismantling and taking down existing unserviceable spacers of any size/ ways in any position from the LT electric overhead lines of any height and supplying and fixing new PVC insulated spacers suitable for separating existing LT OH lines complete all as specified and directed.

100

-

-

... More
Clearing of LT OH line 2 mtr all around by cutting tree branches of any numbers and any girth on any numbers of conductors/earth wire complete all as specified and directed by Engr-in-charge. Note: Length along aluminium conductor shall be measured and paid.

3800

-

-

... More
Disconnecting LT cable of size from 16 Sqmm 4 core to 35 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs, nut-bolt and washers of suitable size and reconnect the existing system and including LT joints of cable size 16 sqmm 4 core to 35 sq mm 3.5 core and all specified and direceted.

9

-

-

... More
Disconnecting LT cable of size from 50 Sqmm 3.5 core to 120 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs, nut-bolt and washers of suitable size and reconnect the existing system and including LT joints of cable size 50 sqmm 3.5 core to 120 sq mm 3.5 core and all specified and direceted..

9

-

-

... More
Disconnecting LT cable of size from 150 Sqmm 3.5 core to 300 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs, nut-bolt and washer of suitable size and reconnect the existing system and including LT joints of cable size 150 sqmm 3.5 core to 300 sq mm 3.5 core and all specified and direceted..

10

-

-

... More
Supplying, laying & jointing GI tubing, 80 mm bore, light grade as in sleeving etc. laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.

48

-

-

... More
Supplying, laying & jointing GI tubing, 50 mm bore, light grade as in sleeving etc. laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
M&L for surface excavation over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15cm depth including cleaning the bushes and vegetation and leveling incl removal of surplus soil in hard/ dense soil. Note:- All necessary T&P and safety equipments required for the job will be provided by the contractor.

1000

-

-

... More
Removing/scraping the existing pre-painted aluminium paint preparing surface and applying new paint with two coats of approved quality aluminium paint on 11 mtrs long existing HT pole above coping all as directed and required along with existing accessories such as clamps, channels, angles etc. including numbering of poles with white paint on black back ground as per the directions and three Nos of reflector strips of 15 CM width over the pole surface on height of 1.50 mtr from GL in Red, Yellow, Green colours as approved all to the entire satisfaction of Engr-in-Charge.

10

-

-

... More
All as specified in Sl item No 56 here-in-before but for 9 mtrs long LT poles.

138

-

-

... More
Removing/scraping the existing pre-painted aluminium paint preparing surface and applying new paint with two coats of approved quality aluminium paint on 2 Pole structure all as directed and required along with existing accessories such as clamps, channels, angles, bracing etc. including numbering of poles with white paint on black back ground as per the directions and three Nos of reflector strips of 15 CM width over the pole surface on height as directed in Red, Yellow, Green colours as approved all to the entire satisfaction of Engr-in-Charge.

8

-

-

... More
Removing/scraping the existing pre-painted aluminium paint preparing surface and applying new paint with two coats of approved quality aluminium paint on 4 Pole structure all as directed and required along with existing accessories such as clamps, channels, angles, bracing etc. including numbering of poles with white paint on black back ground as per the directions and three Nos of reflector strips of 15 CM width over the pole surface on height as directed in Red, Yellow, Green colours as approved all to the entire satisfaction of Engr-in-Charge.

5

-

-

... More
Disconnecting GOD of capacity 11KV, dismantling of GOD for complete repair & overhauling and checking the serviceability of spares and operating mechanism and replacement of defective/worn out spare parts for making the GOD functional including reassembling of operating mechanism, oiling & greasing of moving parts, fine setting of mechanism, making the GOD perfect operational in manual mode complete all as specified and directed. Note :- New spare parts replaced for GOD shall be measured and paid for separately under respective items of Sch 'A' as “supply only” but fixing element of same shall be deemed to be included under this item.

5

-

-

... More
Supply only the following new parts suitable for GOD of 11KV of existing make and descriptio to be repaired under Schedule `A' item No 60 here-in-before NOTE: - (i) The new parts shall be suitable to match with the existing GOD. (ii) Fixing element of these items like nut, bolts, washers etc. is deemed to be included under the rates quoted by the contractor for respective Schedule `A' item No 60 here-in-before.

-

-

-

... More
(a) 11KV post type insulator

5

-

-

... More
(b) Male contact/moving contact blade.

5

-

-

... More
(c) Female contact/fix contact Jaw

5

-

-

... More
(d) MS Jumper carrier

5

-

-

... More
(e) Tinned copper flexible jumper

5

-

-

... More
(f) Back connector plate

5

-

-

... More
(g) Fix top contact / L contact

5

-

-

... More
(h) Fix bottom contact

5

-

-

... More
Supply, fixing, commissioning and testing of outdoor, gang operated switch, tilting type, 11KV of current rating upto 200 Amps, triple pole, each pole consisting of galvanized steel base, HT insulators as per IS, non ferrous knife and spray, loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers, horizontal GI pipe of adequate length for phase separation, adequate length of GI pipes for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather and suitable for vertical mounting complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Taking down unserviceable Drop out fuse set outdoor type ratio 100 Amps of 11 KV and supply and fix drop out fuse set 66 KV, 100 Amps mounted on insulators and steel frame complete all as specified and directed.

2

-

-

... More
Supply & errect in position steel tubular pole complete with MS base plate finial taper plug, cap bolt, nut screws etc all as specified regarding swaged pole of type 410 SP-55 11 mtrs long incl painting with one coat of red oxide paint and there after two coats of aluminium paint and black bitumen paint on hidden surface in foundation of structure of approved make/quality complete all as specified and directed. Note: Earth work and PCC for foundation of steel pole shall be done as per manufacturer's instruction and shall be measured and paid separately

2

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level duly connected to galvanised earth lead strip 25mm x 4 mm with protection pipe of 40mm dia GI pipe, light grade, by means of bolts, nuts chek nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earth test point all as specified including necessary earth work, gun metal test point block, PCC work, in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge. Note: (i) Test result of earthing to be submitted by the contractor for all earthing . (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders,aggragates,gravel etc. (iv) The rate quoted by the bidders shall be also be deemed to include :-(a) Excavation upto 5 mtr depth and returning filling in any type of soil and disposal of surplus soil. (b) Supply of charcoal and common salt.

4

-

-

... More
S&F MCCB 630 Amps 4 Pole, 50 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type, Icu=Ics, and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
S&F MCCB 400 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type, Icu=Ics, and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
S&F MCCB 250 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type, Icu=Ics, and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
S&F MCCB 200 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type, Icu=Ics, and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
S&F MCCB 100 Amps 3 Pole, 16 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type, Icu=Ics, and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Taking down old unservisable fluorescent board and S &F fluorescent board 8 feet x 2 feet made out of 24 gauge GI sheet and front with acrylic sheet total enclosed with computerised letter writtings of size not less than 100 mm height as direcetd by Engineer in charge and inside with 4 feet long 02 Nos of 18 Watt LED tube light fitting complete with time control switch, MCB and battery back up with timer and synchronised motor board including writting, with complete service connection of 2.50 Sqmm 3 Core copper sheathed cable 10 metre long including protection pipe service connection from the pole by means of 40 mm dia light grade pipe to the board including excavation, returning filling and removing out surplus soil, Complete all as specified and directed.

1

-

-

... More
Demolition/Dismantling of existing PCC platform of Transformer at Sub Station of any capacity and M& L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate, repairing the cable duct after disconnecting the LT/HT cable from transformer to LT panel and relaying the same after repair of duct and laying the existing GI plate for covering of cable tray including refixing of transformer after repair of foundation complete all as specified dircetd by Engr-in-Charge.

2

-

-

... More
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.

1800

-

-

... More
Disconnecting, taking out and removing old existing unserviceable under ground, HT 11 KV cable of any type and in any position complete including taking down protection pipe, cable covers etc all as specified and directed by the Engineer-in-Charge of the following sizes:-

-

-

-

... More
(a) 95 Sqmm to 120 Sqmm 3 core

400

-

-

... More
(b) 150 Sqmm to 240 Sqmm 3 core

200

-

-

... More
Laying, jointing and testing 11KV, HT UG cable of any type laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge of following sizes :-.

-

-

-

... More
(a) 95 Sqmm to 120 Sqmm 3 core

200

-

-

... More
(b) 150 Sqmm to 240 Sqmm 3 core

100

-

-

... More
Supply, laying , jointing & testing 11 KV (Earthed) , aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended up to date having following cross sectional area complete all as specified and directed by the Engineer-in-Charge.

-

-

-

... More
(a) 95 Sqmm, 3 core

100

-

-

... More
(b) 120 Sqmm, 3 core

100

-

-

... More
(c) 185 sqmm, 3 core

50

-

-

... More
(d) 240 sqmm, 3 core

50

-

-

... More
Excavation for removing/checking of HT cable joint with draining out water in trenches including returning filling of existing soil, sand , PCC cable cover and making good disturbed surfaced after repair complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
S&F in replacement Jointing and testing of Straight through Heat shrinkable joint suitable for 11 KV, XLPE/PVC insulated cable of following sizes complete material and labour including cutting the faulty straight through of any type and in any position. Note :-(i) All Necessary T & P required shall be arrange by the Contractor. (ii) The contractor has to rectifie the joint with in 4 Hrs after the complaint, in case of failure the penalty of Rs.1000 per hours shall be recovered from the contractor.

-

-

-

... More
(a) 50 Sqmm to 95 Sqmm, 3 core

7

-

-

... More
(b) 120 Sqmm to 185 Sqmm 3 core

7

-

-

... More
(c) 240 Sqmm to 300 Sqmm 3 core

4

-

-

... More
S&F in replacement , jointing and testing for indoor type Heat shrinkable end termination joint suitable for 11 KV, XLPE/PVC insulated cable of following sizes complete material and labour including cutting the faulty indoor end termination joint of any type and in any position. Note :-(i) All Necessary T & P required shall be arranged by the Contractor. (ii) The contractor has to rectifie the joint with in 4 Hrs after the complaint, in case of failure the penalty of Rs.1000 per hours shall be recovered from the contractor.

-

-

-

... More
(a) 50 Sqmm to 95 Sqmm, 3 core

13

-

-

... More
(b) 120 Sqmm to 185 Sqmm 3 core

15

-

-

... More
(c) 240 Sqmm to 300 Sqmm 3 core

7

-

-

... More
S&F in replacement jointing and testing for outdoor type Heat shrinkable end termination joint suitable for 11 KV, XLPE insulated cable of following sizes complete material and labour including cutting the faulty outdoor end termination joint of any type and in any position. Note :-(i) All Necessary T & P required shall be arranged by the Contractor. (ii) The contractor has to rectifie the joint with in 4 Hrs after the complaint, in case of failure the penalty of Rs.1000 per hours shall be recovered from the contractor.

-

-

-

... More
(a) 50 Sqmm to 95 Sqmm, 3 core

13

-

-

... More
(b) 120 Sqmm to 185 Sqmm 3 core

16

-

-

... More
(c) 240 Sqmm to 300 Sqmm 3 core

6

-

-

... More
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified

1

-

-

... More
M&L for Plain Cement concrete C-1 (1:3:6) using 20 mm crushed stone aggregate as in foundations and mass including necessary filling complete all as specified and direcetd.

1

-

-

... More
M&L for Boring of hole under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Engineer-in-Charge. Note : Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/ taxi track/ apron /floors etc.

15

-

-

... More
Supply and laying and jointing GI water tubing in repair, 100 mm bore, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
Material and labour for checking and finding out pin point location of fault in HT 11 KV underground cable with the help of fault locating High Tech mobile machine complete all as directed. Note : (i) Charges for rent and transportation of the fault locating high tech mobile machine including DG Set, necessary earth work for repair HT cable, testing of cable after repair, charges for operator, engineer, electricians etc deemed to be included in the quoted rate. (ii) Fault locating high tech mobile machine will be provided as and when required on short notice otherwise an amount of Rs. 5000/Per day will be charged as penalty.

21

-

-

... More
Supply, installation, testing and commissioning of factory fabricated CPRI approved outdoor Kiosk type HV junction panel for 3 phase, 11 KV, AC, 50 Hz supply & fixing aluminium bus bar of 600 amp rating of suitable size , cubical of appropriate size made of 3.00 mm thick CRCA steel sheet and angle iron base & legs 25mm x25mm x 5mm totally enclosed with top canopy, free standing, water, dust & vermin proof with IP 65 protection powder coated internally and externally not less than 80 micron thick after seven tank pretreatment process including locking arrangement and embeding angle iron legs in PCC (1:3:6) type C-1 precast blocks of size 20X20X45 cm deep all as specified & directed.

5

-

-

... More
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32mm x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing complete all as specified & directed by Engineer-in-Charge. Note: (i) Test result of earthing to be submitted by the contractor for all earthing . (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders,aggragates,gravel etc. (iv) The rate quoted by the bidders shall be also be deemed to include :-(a) Excavation upto 5 mtr depth and returning filling in any type of soil and disposal of surplus soil. (b) Supply of charcoal and common salt.

5

-

-

... More
Supply and laying hard core broken stone/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, to a true surface at the places as specified and directed by Engineer-in-charge.

7

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.