Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date21 May 2024
Closing Date4 Sep 2024
Tender Amount₹ 1,09,00,000
Costs
EMD
₹ 1,84,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_655054_1Bid Award Id
ViewTender No
81044/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out, in hard/dense soil complete all as specified and directed.
330
-
-
Excavation in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0 m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 3m in depth for shafts, cesspits, manholes, pier holes, etc and getting out, in hard/dense soil complete all as specified and directed.
122.5
-
-
Excavation over areas , not exceeding 1.5 metre deep and getting out, in soft/loose soil complete all as specified and directed.
267
-
-
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
392.25
-
-
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
17
-
-
Removing excavated soil exceeding 50m but not exceeding 250 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
382
-
-
Removing excavated soil exceeding 1.5 KM but not exceeding 5 KM and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
445.5
-
-
M&L for cement concrete 1:4:8 Type D-2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
70.09
-
-
M&L for Reinforced cement concrete DESIGN MIX M-25 using 20 mm graded stone aggregate in foundation, including rafts, footings, beams, plinth beams; bases for columns; etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
68.82
-
-
M&L for Reinforced cement concrete DESIGN MIX M-25 using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
32.17
-
-
M&L for Reinforced cement concrete DESIGN MIX M-25 (20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
53.05
-
-
M&L for Reinforced cement concrete DESIGN MIX M-25 (20 mm aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
78.2
-
-
M&L for form work smooth finishes to sides of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar works; vertical or to batter, complete all as specified and directed.
142.41
-
-
M&L for form work RECTANGULAR FLAT smooth finishes to sides of pillats, posts, struts, piers, columns and stanchions complete all as specified and directed.
286.65
-
-
M & L for Formwork RECTANGULAR FLAT smooth finishes to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc., complete all as specified and directed.
288
-
-
M & L for formwork FLAT SMOOTH FINISHES to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete finish, complete all as specified and directed.
574.16
-
-
M&L for mild steel TMT bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
16891.2
-
-
M&L for mild steel TMT bars 8 mm dia and over, as in stirrups, spacers and binders for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
2160
-
-
M&L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
62.82
-
-
M&L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
59.28
-
-
M & L rendering 15mm thick on brick wall or concrete internal surface in cement mortar ( 1:6), finished even and smooth without using extra cement complete all as specified and directed.
310.24
-
-
M & L rendering 15mm thick on fair faces of brick wall or concrete external surface consisting of two layers, under layer of 10mm thick in CM (1:4) & top layer of 5mm thick in cement mortar 1:4 mixed with liquid water proofing compound, finished even and smooth without using extra cement complete all as specified and directed. (Note:- Liquid Water proofing compound shall be measured and paid for separately as " Supply only".)
319.84
-
-
M & L Moorum / red bajari filling in floor or pavings, laid in layers n. exc 15 cm thick, spread, levelled and rammed including watering as required, complete all as specified and directed.
337.99
-
-
M &L Hardcore of guage n exc 63 mm, deposited, spread and levelled n. exc. 15 cm thick, watered and rammed to true surface with broken stone or boulder complete all as specified and directed.
389.86
-
-
M&L 100 mm thick PCC (1:2:4) type B-2, using 40 mm graded crushed stone aggregate as in flooring with surface finishes even & smooth without using extra cement complete all as specified and directed.
453.6
-
-
M&L Water proofing treatment on roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete :-
-
-
-
M&L 10 mm thick rendering on roof surfaces/concrete surface in CM 1:3 complete.
453.6
-
-
Applying evenly a prime coat of bitumen 85/25 grade @ 1.2 kg/ Sqm including cleaning surfaces.
453.6
-
-
Laying unrolled over the bitumen coated surface,3 mm thick polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction.
453.6
-
-
Applying two coats of bituminous base aluminium paint with 0.2 kg /sqm on Surfaces including preparation complete
453.6
-
-
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars and similar work conforming to Fe- 290 ( Gde-E-165) complete all as specified and as directed. Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts). No claim whatso ever shall be entertained by Govt on this account.
377.88
-
-
M & L 75mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
87.63
-
-
M & L Damp proof course 40 mm thick in PCC (1:2:4) type B-0, to horizontal or vertical surface, complete all as specified and directed.
26.08
-
-
Supply and fix aluminium (powder coated ) three track sliding window comprising of one fly proof shutter and two glazed shutters with frames of size 92.0mm x 31.75mm x 1.30mm thick and shutter frames of size 40mm x 18mm x 1.55mm thick with necessary joining cleats, glazing clips, rubber gasket, anodised aluminium snap beading and connected locking arrangement complete all as per manufacturer's catalogue and specifications complete all as specified and directed. (Notes : (i) aluminium wire mesh/wire cloth shall be deemed to be included in the quoted rate for the item; (ii) Aluminium alloy wire cloth in panels of wire gauzed shutter shall be 0.45 mm nominal dia of wire and avg width of aperture 1.40 mm, fixed with aluminium wire staples; (iii) Glazing shall be measured and paid for separately against relevant item of this BOQ
80.56
-
-
S&F 5.5 mm thick sheet glass, ordinary quality and glazing with rubber gasket in square exceeding 0.5 Sqm in each pane, complete all as specified and directed.
58.71
-
-
M & L Machine cut Kota stone slab flooring 18-20 mm thick over and including cement screed base 15mm thick in CM(1:6), laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
453.6
-
-
M & L Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 10mm thick rendering in cement mortar 1:4 , on fair faces of brick work or concrete surfaces as backing complete all as specified and directed.
36.29
-
-
M&L for providing Reinforced cement concrete of DESIGN MIX M-25 (using 20mm graded stone aggregate) for landings, chajjas, and similar articles with plain faces etc. with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match the shade set in CM 1:4 including necessary form work complete all as specified and directed.
6.34
-
-
S&F Stainless steel conduit curtain rod with PVC coating fancy type curtain rod 20 mm dia of any colour including end globe as approved complete including side mounting complete all as specified and directed.
55.6
-
-
S&F Stainless steel Bracket with PVC coating fancy type for curtain rod 20 mm dia of any colour as approved complete all as specified and directed.
32
-
-
S&F 100mm long butt hinges med wt cold rolled mild steel and fixed complete all as specified and directed.
24
-
-
S & F Door spring ordinary rat tail rod pattern springs including roller and roller plate complete of mild steel 150mm long complete all as specified and directed.
8
-
-
S&F 200mm long aluminium anodised barrel tower bolt and 12 mm dia fixed, complete all as specified and directed.
8
-
-
S&F 150mm long aluminium anodised handle cast type and fixed,complete all as specified and directed.
8
-
-
S&F alluminum alloy, anodised, sliding door bolt with hasp & staple (bolt type) and length of 250 mm long etc. complete all as specified and directed.
8
-
-
S & F mortice Lock 4 lever with all fittings for aluminium door complete all as specified and directed.
4
-
-
S & F door closer hydraulically regulated designation No 3, universal type, suitable for door shutter of weight between 61 to 80 Kg of aluminium (Die cast) body complete all as specified and directed.
8
-
-
M & L rendering 5mm thick on ceiling in cement mortar (1:3) finished fair and even smooth without using extra cement complete all as specified and directed.
577.44
-
-
M & L applying two coat of plastic emulsion on newly plastered or unplastered ceiling surfaces including preperation of surfaces over a coat of Primer and including 2mm thick wall care putty in two layers on ceiling complete all as specified & directed..
491.04
-
-
M & L applying two coat of plastic emulsion on newly plastered or unplastered wall surfaces including preperation of surfaces over a coat of Primer and including 2mm thick wall care putty in two layers on walls complete all as specified & directed.
722.24
-
-
M&L for PCC Type B-1 1:2:4 as in in surface channels and drains complete using 20mm graded stone agregates complete all as specified and directed.
5.85
-
-
Extra work forming fair finished drain or channel over 60cm inner girth in cement concrete complete all as specified and directed.
130
-
-
M & L Providing, cement concrete PCC Type B-1 1:2:4 as in seismic and other similar band coping using 20mm graded stone aggregates, including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed.
13
-
-
Rendering 15mm thick in CM (1:4) on other than fair faces of brick work or concrete surfaces, surface finished even and smooth without using extra cement complete all as specified and directed.
312
-
-
M&L 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed
594
-
-
M&L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment, confirming to IS 15658-2006of 80mm thickness M 40 Grade over and including 50mm thick sand cushioning complete all as specified and as directed.
594
-
-
M&LSub main wiring with four single core PVC Insulated cable two run of size 4.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing into PVC conduct,medium grade not less than 25 mm dia with al conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed.
Note :- two run of 4.0 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
30
-
-
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and includig concealed PVC conduit not less than 20mm (ISI marked) Including all fitting and fixing and accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint niside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
-
-
-
(a) One light point controlled by one switch 5/6 Amp.
42
-
-
(b) One fan point/ex fan controlled by one switch 5/6 Amp.
36
-
-
(c) One socket point controlled by one switch 5 / 6 Amp on same board.
5
-
-
(d) One socket point controlled by one switch 5/6 Amp on Independent board.
20
-
-
Description all as per item No 57 here in before but with 1100 volts grade copper standard conductor cable of size 2.5 Sqmm with 2.5Sqmm solid copper conductor PVC for 3 pin switch socket outlet 15Amp independent board complete all as specified and directed .
8
-
-
M&L for fan regulator socket type AC 230 volts complete all as specified and directed.
30
-
-
M&L for Switch piano flush type AC 230 volts 5 Amps single ole one wat complete all as specified ad directed .
103
-
-
M&L for Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed .
25
-
-
M&L for Switch socket combination 3 pin 5 and 15 Amps AC 230 volts flush type complete all as specified and directed .
8
-
-
M&L for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed .
78
-
-
Supply & Fixing Smart bright batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and efficient, Flicker free start Inbuilt driver intil Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1/ISL 10322(Parts/Secl) , report has established conformity of the product(s) to the requirements of the Standard/Specification complete all as specified and directed .
36
-
-
Supply and fixing Single phase ceiling fan 1200 mm permanent magnet brushless DC Motor 230 v 50 Hz single phase 26-30watt rated current 0.16 amp, pf o.98 370/360 rpm air delivery 220m3 rated service value 629m3/min/watt no of blades three type of blade leaf 1.05 mm thick aluminium sheet remote control radio frequency 5 sped +off timer option speed regualtion class of insulation two nos bearings including connecting wire complete with all as required and directed .
30
-
-
S&F Sheet metal enclosure DBs Single Pole and Neutral 8 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed .
3
-
-
S&F MCB single pole and neutral 240 volts 40 Amps, B Series complete all as specified and directed .
3
-
-
S & F MCB single pole 240 volts 6 to 40 Amps, B Series complete all as specified and directed .
21
-
-
Supply & fix in replacement of LED Security Light Luminaire 35 watt 6000k with high power LED cool white, CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base pole adapter powder coated pressure die medium Grade not less than with 1.2m. long in ant shape with 2 nos of pole fitting clamps made out of MS flat, nuts and bolts and painting with aluminuim paint. complete all as specified and as directed.
6
-
-
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar triple pole and neutral 415 V, 4 Ways, double door type, complete all as specified and directed. With Incoming MCCB of 100 Amps Capacity complete all as specified and directed .
1
-
-
S& F MCB TPN 40 to 100 Amps, 240 Volts, minimum 10 KA, "B" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed (Note :- Proper and suitable size cable copper lugs to be fixed with MCBs are included in unit rate of each MCB of any rating)
1
-
-
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground , (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to and including galvanised iron earth wire 4 mm dia by means iof nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following:- (a) Excavation and earht work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, reinforced with welded steel wire fabric wieghing not less than 1.87 Kg/Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
2
-
-
Supply and fixing Single phase propeller type ventilating (Exhaust fan) heavy duty AC 230 volts 450 mm sweep, metallic body complete with Metalic louvers including making holes of suitable size and making good the disturbed surface and shutters including electric connection with PVC complete all specified and as directed.
6
-
-
Supply , laying and testsilng cable XLPE insulated , screened PVC bedded , galvanized , steel strip or wire armoured , electric power cab les (Heavy duty) 1100 volts grade with stranded aluminium conductor of size 3.5 core 35 Sqmm complete all as specified and directed by Engineer in charge. ( Note : Excavation and earthwork, sand cushioning and cable protection shall be measured and paid for separately against relevant items of this BOQ.)
220
-
-
Supply, installation, testing and commissioning of LT panel, cubical type, 3 phase and neutral, factory made fabricated and CPRI approved, 415 volts, indoor type, dust, weather and vermin proof, front and back open double door with locking arrangements, bricated out of 3.15 mm thick powder coated CRCA sheet, 3mm thick MS angle iron base frame with legs of size 65 X 65 X 5mm and clearance from ground should be of height 60 cm grounted with PCC 1:3:6 type C-1 for foundation filling with floor including entires for incoming and outgoing cable connection and letter written of pattern and descripton as directed,with supply and fixing the followings accessories, pre-wired and connected alongwith suitable cable gland, lugs etc., complete all as directed:-
(a) 4 Nos bus bars of 300 Amps high conductivity tin coated copper strip with heat shrinkable insulator sleeves, 3 Nos for phase (R,Y,B) and 1 No. for neutral rating 1.5 times the rated capacity of incomer MCCB amps mounted on porcelain support- 01 set.
(b) Indicating LED lamps for all the 3 phase with different colour lamps red, yellow and blue.
(c) One set of voltmeter of size 96 X 96sqmm flush type digital with selector switch. (d) One set of ammeter of size 96 X 96sqmm flush type digital copper wound CT operated of suitable required rating amps selector switch. (e) One No danger notice plate of size 200 X 150 X 1.6mm thick mild steel sheet vitreous enameled white and letter figure and conventional skull and bones of signal red colour and fixed/riveted with panel of suitable size. (f) Copper wound with CTR 100/5 -03 Nos
Incoming:- LT MCCB, 4 pole , 415 volts, 16KA, 63 Amps - 01 No.
Out going:- (i) LT MCB , 4 pole, 415 volts, 10kA, 32 Amps-03 No.
(II) Metering equipment complete for incoming and outgoing feeders-1 job NOTE:- (All Switchgears ACB, MCCB should be rotary handle, microprocessor release adjustable type)
1
-
-
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be considered for the payment purpose.)
3
-
-
Supply and laying Brick covering with width equal to length of brick as mechanical protection to cable with fly ash bricks laid drt and flat complete all as specified and directed .
1408
-
-
M&L for GI Tubes, of size 40 mm dia medium grade, galvanised, with all fitting and fixing complete for supporting the cable protection in the roads all as specified and directed.
20
-
-
Earthing complete with galvanised steel eath plate elctrode 60 cm x60 cm x6 mm thicjk buried directly in ground ,(Earth pit not less than 2.25 meter deep bleow ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to adn including galvanised iron earth strip 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including thge material and labour of the following:-
(a) Excavation and earth work for drilling hole for electrode in any type of Soil.
(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 kg/Sq meter.
(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed
(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal.
(f) Testing of earthing.
2
-
-