Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Aerospace and Defence
Electrical Works
Eprocure
Opening Date16 May 2023
Closing Date13 Jun 2023
Tender Amount₹ 36,41,000
Costs
EMD
₹ 72,820Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_595782_1Bid Award Id
ViewTender No
8673 GE(AWC) /MHOW / OF 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Returning filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed.
28
-
-
Removing excavated material n exc. 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
272.1
-
-
M & L PCC 1:4:8 type D-2 using 40 mm graded aggregate as in mass concrete, foundation and any other location etc. complete all as specified and directed.
82.3
-
-
M&L for RCC (design mix) M25 ( 20 mm graded aggregates) as in foundations, including rafts, footings, foundation beam, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
11
-
-
M&L for RCC (design mix) M25 ( 20 mm graded aggregates) as in Columns, pillars, peirs, posts, and struts complete all as specified and directed.
4.5
-
-
M&L for RCC (design mix) M25 ( 20 mm graded aggregates) as in Beams , cantilivers , bressummers , lintles over 1.5 M span complete all as specified and directed.
5.5
-
-
M&L RCC M-25 (Design mix) using 20mm graded stone aggregate as in slabs supported on walls, beams, and columns complete all as specified and directed.
10
-
-
M&L RCC M-25 (Design mix) using 20mm graded stone aggregate as Chajjas complete all as specified and directed.
0.25
-
-
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beam, sides and soffits(if any) of foundation and plinth beams and similar work, vertical or to batter surfaces for rough finished flat surfaces of concrete, complete all as specified and directed.
42
-
-
Use and waste of formwork fair finished surface of concrete as in Square, rectangular or polygonal to sides of columns, pillars, posts, struts, piers etc.complete all as specified and directed.
55
-
-
Use and waste of formwork fair finished surface of concrete to sides and soffits of floor or roof beam, beam hauchings, bressummers, lintels, shelves etc. including supports, overhangs, etc, complete all as specified and directed.
45
-
-
Use and waste of form work fair finished surface of concrete to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizointal or slooping) complete all as specified and directed.
54
-
-
Use and waste of formwork fair finished surface of concrete to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
2.7
-
-
Use and waste of form work fair finished surface of concrete to edges of concrate flats, treads, breaks in floors, and roof n.exc 20 cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but not exc 20 cm wide complete all as specified and directed.
30
-
-
S & F TMT bars 10 mm dia and over, cut to length, bent to shape as required incl cracking, bending spirally for hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed
2260
-
-
Description same as per Item No. 18.00 but 6mm to 8mm dia complete all as specified and directed.
190
-
-
Description same as per Item No. 18.00 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed.
480
-
-
M&L brick work with fly ash modular bricks straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
21.9
-
-
M & L 40 mm thick Damp proof course in cement concrete 1:2:4 type B-0 with incorporating integral water proofing compound in the manner specified by the manufacturer and in the proportions indicated, to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. Note:- WPC will be measured and paid separately.
5.6
-
-
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cills, steps, seismic and other similar bands, plinth courses, string courses, parapets and railing upto 60 cm in height, coping, kneelers, apex stones bed plates, etc and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary use and waste of form work, complete all as specified and directed.
0.4
-
-
M & L rendering 10 mm thick on brick wall/cement block wall or concrete surfaces in cement mortar 1:6, surfaces finished even and smooth without using extra cement , complete all as specified and as directed.
84
-
-
M & L 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling surface finish even and smooth without using extra cement , complete all as specified and directed..
62
-
-
M & L Plastering 15 mm thick in two layers of 10 mm thick in bottom and 5 mm thick with WPC of top layer in Cement Mortar 1:4 on brick wall/cement block wall or concrete surfaces, surfaces finished even and smooth without using extra cement , complete all as specified and as directed. Note:- WPC will be measured and paid separately.
120
-
-
Supply only liquid water proofing compound all as specified and directed
3.5
-
-
M & L for preparation of newly plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
62
-
-
M&L for applying 1 mm thick wall care putty on wall on internal old/new wall surfaces as per manufacturerer instruction complete all as specified and as directed
84
-
-
M & L for applying two coats of oil bound distemper over a coat of alkali resistant primer on prepared wall putty surfaces of internal wall all including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as per specified and directed.
84
-
-
M&L preparing of newly plastered or unplastered surfaces of walls, cornices etc and applying two coats of cement base paint over one coat of cement primer, complete all as specified & directed.
120
-
-
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
45
-
-
M & L 20 - 25 mm thick machine cut Kota stone slab in flooring or treads of steps over and including 20mm thick screed bed in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab/rubbing, polishing etc. complete all as specified and directed. Note:- (i) The size of Kota stone slab shall not less than 550 mm x 550 mm cut size, except the location where the balance portion remain less than size as specified above.
97.6
-
-
Description same as per Item No. 33.00 but as in riser of steps, skirting, dado and vertical surfaces including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
3.5
-
-
M&L Rounding to edges of stone slabs one edges, such as in steps, cooking platform, and other similar situations for bullnosing / moulding to exposed edges( any type) and polishing to match the adjoining surfaces complete all as specified & directed.
288
-
-
M & L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar places, surface finished even and fair without using extra cement incl necessary use and waste of form work complete all as specified and directed.
1.7
-
-
S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
2595
-
-
S & F Powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters glazed and one shutter wire mesh) making good the adjacent side of jombs of windows by plastering in CM 1: 3 even and smooth complete etc . shifting of existing cooler stand where required complete all as specified and as directed by Engr-in-charge and should have following specification complete all as specified and as directed by Engr-in-charge.
(i) Windows frame of cross section 101mm x 44mm x 1.5mm thick.
(ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm x1.1mm thick.
(iii) Sliding shutter frame of cross section 40 x 18 x 1mm thick.
(iv) 4 mm thick tinted glass superior quality.
(v) IDPE Rubber guasket for fixing of glass.
(vi) Locking cleats per shutter -01 Nos.
(vii) Sliding rollers per shutter - 02 Nos.
(viii) Aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56mm for shutters 01 Nos.
154.6
-
-
Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required all as specified and directed complete all as specified and directed.
4
-
-
S&F Pressed steel frames size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
5.4
-
-
S&F 2nd class hard wood 35 mm thick Plain, framed, pannelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, complete as specified.
2.2
-
-
S&F 2nd class hard wood 35 mm thick Glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc, (without sash bars),edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc, size of members of shutters as specified in SSR Part I, Section 8, clause8.24(a) complete all as specified and directed.
Note :- Glass pane and wire mesh shall be measured and paid separately in respective supply only item.
2.2
-
-
Supply only galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
2
-
-
M & L Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise description, over 10 cm width or girth apply two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
9
-
-
S&F aluminium anodised barrel tower bolts 200 mm long of extruded section and fixed complete all specified and directed.
4
-
-
S&F aluminium handles, size 150 mm cast type, anodised complete all as specified and directed.
8
-
-
S&F 300mm mild steel ordinary rat rail rod pattern springs including roller & roller plate complete all as specifeid and directed.
2
-
-
S & F butt hinges, size 100 mm type C-21 extruded aluminium alloy with galvanised mild steel hinge pin, anodised ISI marked complete all as specified and directed
12
-
-
M & L 100mm length floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor complete all as specified and as directed.
4
-
-
S&F 250 mm long aluminium alloy, anodised sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and directed.
1
-
-
S & F tubular rolled sections as post, rafter, purlin, and its connected wk for shed structure and similar work complete using ERW or induction butt welded tubes conforming to I.S. 1161-1976 grade St.-240, all as specified and directed.
210
-
-
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in sun shade, roof covering/ cladding to wall, and similar work fixed with self tapping screws complete all as specified and directed.
88
-
-
M & L Preparation of new or previously untreated steel and iron surfaces of any description, not otherwise description, over 10 cm width or girth apply two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
238.6
-
-
M&L Water proofing treatment on "Non approachable / non accessible roof" surface (Horizontal & Vertical surfaces) in following sequence through authorized applicator of the manufacturer all as specified and directed complete. (i) cleaning of new rendered surfaces properly and drying the surfaces. (ii) Applying a coat of oxidised bitumen based solvent primer @ 0.30 Kg / Sqm (iii) Laying 3 mm thick APP modified water proofing membrane with 100 mm over laps sealed and bounded to the surfaces by 'torchon' method.(iv) Applying two coats of bitiminous aluminium paint @ 200 Gram / Sq M (minimum) in two coats .Make incorporated : HYPERPLAS POLYSTER OF IWL (INDIA) LTD or equivalent in Pidilite industrries Ltd /STP Ltd all as specified and as manufacturer instruction complete. as per manufacturers instruction.
70
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from the frames)exc 1.5 sqm but not Exc 4.0 sqm each and removal from site complete all as specified and directed.
82
-
-
M&L brick work with fly ash brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including demolition of brick work built in cement mortar complete all as specified and directed.
3
-
-
M & L 15 mm thick rendering on brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement complete, all as specified and directed.
119
-
-
M&L preperation of new plastered surface and applying one coat of oil bound distemper over 1mm thick wall care putty complete all as specified and directed.
59
-
-
Surface excavation in any type of soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
936.5
-
-
M&LSand filling under floors or in foundations including watering and consolidation for interlockin paver block complete all as specified and directed.
63.68
-
-
M&L Machine pressed precast concrete interlocking paver block any shape and size / any colour confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed.
722
-
-
Providing, cement concrete TypeB0 (1:2:4 ) (12.5mm graded graded graded aggregate)in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
16.07
-
-
M&L 100 mm thick Cement concrete type B- 2, 1:2:4 (40mm gradedaggregate) as in sub base of floor finishes complete all as specified and directed.
240
-
-
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40Grade with grey cement and no pigment complete all as specified and directed.
240
-
-
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, drain, saucer drain channel, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in soft/loose soil and getting out complete all as specified and directed.
7
-
-
M&L Cement concrete in surface channels and drains Type B 2, 1:2:4 (40mm graded stone aggregate) complete all as specified and directed.
6
-
-
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
62
-
-
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting hard/dense soil all as specified and directed.
14.5
-
-
M&L cement concrete Type B1, 1:2:4 (20mm graded stone aggregate) as in packing/grouting of trg infra structure, in walls or retaining walls,any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
6.5
-
-
M & L for preparation of New surfaces including brooming down or steel wire brushing, scrapping down smoke soot,moulds,moss and efflorescent salt and trading oil and greasy spots of wall and applying two coat of white wash complete all as specified and directed.
60
-
-
M&L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmen Fe-410- W(Gde E-250) quality complete all as specified and directed.
14
-
-
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
900
-
-
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
430
-
-
M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for the One light / fan /bell controlled by one, one way switch 5/6 Amps all as specified and directed.
17
-
-
Description same as per Item No. 110.00 here in above but One 3 pin, 5/6 amps socket outlet point on independent board controlled by one, one way 5/6 amps switch complete all as specified and directed.
5
-
-
Description same as per Item No. 110.00 here in above but One 3 pin, 5/6 amps socket outlet point on same board controlled by one, one way 5/6 amps switch complete all as specified and directed.
1
-
-
M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module, for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one 15A socket point independent complete all as specified and directed.
2
-
-
S&F in Ceiling rose three terminals surface bakelite type, AC, 50 HZ, 230V complete all as specified and directed.
10
-
-
S&F modular switch 1 way 6 A , 1 module complete all as specified and directed.
23
-
-
S&F modular socket 6 Amps 2/3 pin combined 2 module complete all as specified and directed.
6
-
-
S&F switch modular type 16 A, 1 module complete all as specified and directed.
2
-
-
S&F socket modular type multipurposes 6/16 A, 2 module complete all as specified and directed.
2
-
-
S & F for wall mounted LED tube light fitting 18 to 20 watts batten with, system efficency = 100 lumens/watts for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
6
-
-
M&L for Modular angular holder with LED Bulb 9 watts complete all as specified and as directed
2
-
-
M&L for LED Bulk head fitings 6.5 watts designed for modern homes available with premium quality diffuser for glarefree light and easy to install snapfit installer, making good of surfaces complete all as specified and directed.
2
-
-
S & F LED bldg security light fitting 30 watt made up of pressure die cast aluminium housing with acylic cover as diffuser with IP-66 protection complete incl mounting pipe made of GI tubing 40 mm size 1M length bend into size with mounting brackets nut bolt and washers all as specified and directed.
4
-
-
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
1
-
-
Supply & Fix MCB SPN 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.
1
-
-
Supply & Fix MCB SP 6 to 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.
2
-
-
Supply and fix in ceiling fan 1200 mm sweep , BLDC fan,BEE rated 5 star ceiling fan or above with 350 RPM or above with power factor of /=.0.90 for air delivery of 220 M/Cum minimum service value of 7 with electronic modular type fan regulator 1 module or with remote, complete all as specifeid and as directed.
3
-
-
M&L for Tubes, 'light grade,galvanised, with all fitting of size 40 mm ;laid in trenches, under floors,roads,along poles for protection of cable with all necessary fittings and sealing ends complete all as specified and directed.
10
-
-
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel connected to earth test point including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion complete all as specified and directed.
Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.