Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Jun 2024
Closing Date29 Jun 2024
Tender Amount₹ 20,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.

110

-

-

... More
Supplying & Laying Sub Class `B’ common burnt bricks old size as in cable protection all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Laying only old retrieved serviceable bricks/cable covers for cable protection as obtained from dismantling of the existing cable complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any type and in any position complete including taking down protection pipe complete all as specified and directed by the Engineer-in-Charge for the following sizes:

-

-

-

... More
(a) 10 Sqmm to 25 Sqmm any core

500

-

-

... More
(b) 35 Sqmm to 70 Sqmm 3½ core

680

-

-

... More
(c) 95 Sqmm to 150 Sqmm 3½ core

440

-

-

... More
(d) 185 Sqmm to 300 sqmm 3½ core

150

-

-

... More
Laying, jointing and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminium conductor cable 1100 volts grade of any type laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-

-

-

-

... More
(a) 10 Sqmm to 25 Sqmm any core

50

-

-

... More
(b) 35 Sqmm to 70 Sqmm 3½ core

50

-

-

... More
(c) 95 Sqmm to 150 Sqmm 3½ core

30

-

-

... More
(d) 185 Sqmm to 300 sqmm 3½ core

50

-

-

... More
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed by the Engineer-in-charge for the following sizes:

-

-

-

... More
(a) 16 Sqmm 4 core

250

-

-

... More
(b) 25 Sqmm 4 core

200

-

-

... More
(c) 35 Sqmm 4 core

200

-

-

... More
(d) 50 Sqmm 3.5 core

230

-

-

... More
(e) 70 Sqmm 3.5 core

200

-

-

... More
(f) 95 Sqmm 3.5 core

150

-

-

... More
(g) 120 Sqmm 3.5 core

150

-

-

... More
(h) 150 Sqmm 3.5 core

110

-

-

... More
(j) 185 Sqmm 3.5 core

100

-

-

... More
S&F, jointing and testing for provision of straight through joints, Heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, for following sizes all as specified and directed by the Engineer-in-Charge.

-

-

-

... More
(a) 10 Sqmm to 16 Sqmm any core

10

-

-

... More
(b) 25 Sqmm to 50 Sqmm 3½ core

12

-

-

... More
(c) 70 Sqmm to 120 Sqmm 3½ core

18

-

-

... More
(d) 150 Sqmm to 185 Sqmm 3½ core

25

-

-

... More
(e) 240 Sqmm to 300 Sqmm 3½ core

20

-

-

... More
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 50 mtr etc complete all as specified

2

-

-

... More
S&F in repair replacemant rusted pipe & jointing GI water tubing, 40 mm bore,light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
All as per Item No 12.00 here-in-before but GI tubing 50 mm bore.

22

-

-

... More
All as per Item No 12.00 here-in-beforebut GI tubing 80 mm bore.

22

-

-

... More
All as per Item No 12.00 here-in-before but GI tubing 100 mm bore.

12

-

-

... More
Taking down existing LT cable from pole/ LT panel/ feeder pilar box etc. cutting the defective/burnt/cracked /heated, unserviceable end portion of cable, preparation of cable end of requird length retrived from rings/loops including necessary execavation and earth work and reconnect through existing protection pipe alongwith the pole/panels/feeder piller box etc with proper size of aluminium lugs, nuts, bolts, washer and M.S. clamps etc testing and commisioning comple all as specified and directed by engineer-in-charge for the following size of LT cables :-

-

-

-

... More
(a) 10 Sqmm to 25 Sqmm cable of any core

10

-

-

... More
(b) 35 Sqmm to 70 Sqmm cable of any core

10

-

-

... More
(c) 95 Sqmm to 150 Sqmm cable of any core

8

-

-

... More
(d) 185 Sqmm to 300 Sqmm cable of any core

8

-

-

... More
Supply & fixing in replacement new PVC insulated, served with inner sheathed pvc tape weatherproof stranded Alumunium conductor cable twin core 6 Sqmm size for connecting from Over head conductor complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
All as per Item No 17.00 here-in-before but of size 10 Sqmm.

200

-

-

... More
All as per Item No 17.00 here-in-before but of size 16 Sqmm.

200

-

-

... More
Supply only PVC Electrical Insulation tape 25 RM all as specified and dircetd by Engr-in-Charge

100

-

-

... More
Supply the hard core broken stone/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, to a true surface at the places as specified and directed by Engineer-in-charge.

24

-

-

... More
Taking down old unserviceable sign board and S &F fluorescent sighn board size 10' x 4' made out of 24 gauge GI sheet and front with acrylic sheet total enclosed with computerised letter of size not less than 100 mm high as diirecetd by Engineer in charge with and including 4 feet long 02 Nos of 18 Watt LED tube light fitting complete with time control switch, MCB and battery back up with timer and synchronised motor complete with service connection of 2.50 Sqmm 3 Core copper sheathed cable 10 metre long including protection pipe service connection from the pole with and including 40 mm dia light grade pipe to the board including necessary PCC, excavation, returning filling and removing out surplus soil, Complete all as specified and directed.

3

-

-

... More
Taking down old unservisable MCCB and S&F MCCB 630 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Taking down old unservisable MCCB and S&F MCCB 400 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Taking down old unservisable MCCB and S&F MCCB 250 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location complete all as specified and as directed by Engineer-in-Charge.

6

-

-

... More
Taking down old unservisable MCCB and S&F MCCB 200 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
Taking down old unservisable MCCB and S&F MCCB 100 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location complete all as specified and as directed by Engineer-in-Charge.

11

-

-

... More
Taking down old unservisable change over switch and S&F On load change over switch, four pole with advance neutral 100 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in the existing panel location complete all as specified and as directed and as directed by Engineer-in-charge.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.