Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date4 Sep 2024
Closing Date1 Oct 2024
Tender Amount₹ 49,00,000
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671771_1Tender No
8766/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Cleaning & removal of blockage, of any type in WC, bathroom, kitchen including floor/nahani traps, soil waste/vent pipes gully trap upto 1st manhole, in any situation by way of cleaning / desludging and removing foreign materials to a place as earmarked by state auth out side the defence land to the entire satisfaction of Engineer-in-charge.
3000
-
-
Note:-
(a) Contractor shall detail his supervisor to office of AGE B/R II daily by 9.00 AM who will report to concerned JE B/R /Engineer-in-Charge to receive all complaints of entire area divided in two parts i.e. Md accn & OTM accn under this contract.
(b) Contractor shall provide service providers (sweepers) separately for both the areas as per the complaints list given alongwith all requisite tools, equipments, including safely measures for attending complaint and ensure completion report by 5.00 PM same day.
(c) Complaint/blockage cleared in one building in a day may be for WC, bath, kitchen, floor/nahani traps etc shall be treated as one complaint.
(d) Please note that all the complaints relating to internal sewage (WC/bath/kitchen etc) shall be attended within same day (within 12 hour).
(e) In case any complaint pertaining to inside the building (WC/bath/kitchen) is not attended by 12.00 hours. A penalty @ Rs. 100 per complaint shall affected from contractor payments.
-
-
-
Clearing & removal of all blockage in sewage line of any dia of sewer lines, manholes of any section and any depth, in any situation by way of cleaning / desludging foreign materials as well as blockage of sewage line in between successive manholes manunally / mechanically including desludging of manhole /sewage line where required and odered by Engineer-in-charge and keeping sewer line functional, upto final drop/outlet into septic tank /central sewage system terminating in other joining zone/ area or into sewage wells complete all as specified.
3000
-
-
Note:-
(a) Contractor shall detail his supervisor to office of AGE B/R II daily by 9.00 AM who will report to concerned JE B/R /Engineer-in-Charge to receive all complaints of entire area under this contract.
(b) Contractor shall provide service providers (sweepers) as per the complaints list given alongwith all requisite tools, equipments, including safely measures for attending complaint and ensure completion report by 5.00 PM same day.
(c) Please note that all the complaints relating to sewage line shall be attended within same day (within 12 hour). In case of blockage in sewage line could not be detacted/completed same day and concerned JE / Engineer-in-Charge is satisfied to the efforts applied but the same shall be attended and all blockage must be cleared by 24 hours (next day by 5.00 PM) without fails.
(d) In case any complaint pertaining to clearing of blockage in sewage line is not removed /cleared within 24 hours (next day 5.00 PM). A penalty @ Rs. 200/- per complaint shall affected from contractor payments.
(e) Blockage cleared between two man holes irrespective of length in between shall be treated as one complaint.
-
-
-
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in soft/loose soil etc complete all as specified and directed
1268.3
-
-
Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed
1014.64
-
-
Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed
253.66
-
-
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe complete all as specified and directed.
2256
-
-
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 200 mm internal dia of pipe complete all as specified and directed.
50
-
-
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
30
-
-
M&L for salt Glazed stone ware drain pipe 150 mm bore grade 'A' laid in trenches and jointed and testing complete all as specified & directed.
25
-
-
M&L for laying DWCP 150 mm dia pipes in trenches Class SN-8 conforming to IS 16098 (Part -2) in 6 mtr length with coupler complete all as specified and directed by Engr-in-charge
2231
-
-
M&L for laying DWCP 200 mm dia pipes in trenches Class SN-8 conforming to IS 16098 (Part -2) in 6 mtr length with coupler complete all as specified and directed by Engr-in-charge
50
-
-
M&L for 450 mm bore reinforced concrete pipes, class NP2, laid and jointed with collars complete all as specified and directed.
10
-
-
M&L for 600 mm bore reinforced concrete pipes, class NP2, laid and jointed with collars complete all as specified and directed.
20
-
-
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
2256
-
-
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 200 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
50
-
-
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
15
-
-
Demolition of cement concrete reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
7
-
-
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
138.6
-
-
M&L Brick work using old size bricks with sub class 'B' bricks in one brick thick honey comb walling built in cement mortar 1:6 complete all as specified and directed.
20
-
-
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
110
-
-
All as per above item here-in-before but except brick complete all as specified and directed.
12
-
-
M&L for brick work with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
12
-
-
M&L for Broken bricks of gauge not exceeding 63 mm for loose filling in sokage pit, sokage wells complete all as specified and directed.
33
-
-
Supply only integral water proofing compound complete all as specified and directed.
15
-
-
Taking down cement plaster any description on brick or stone walls and including wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
250
-
-
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:4 with water proofing compound @2% of weight of cement and to be finished even and smooth with out using extra cement complete all as specified and directed
450
-
-
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 to be finished even and smooth with out using extra cement complete all as specified and directed
200
-
-
M & L applying three coat of white wash on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified.
200
-
-
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
7.5
-
-
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
50
-
-
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
15
-
-
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 200 mm internal dia of pipe complete all as specified and directed.
5
-
-
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed.
15
-
-
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
650
-
-
M&L for Mild Steel TMT bar 6 to 8mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
350
-
-
M&L for RCC 1:2:4 type B1 using 20 mm graded aggregate as in slab supported on walls, shelves etc.complete all as specified and as directed.
1
-
-
M&L for RCC type B 1, 1:2:4 (using 20mm graded aggregate) as in beams, cantilevers, lintels, over 1.5 m span complete all as specified and as directed.
1
-
-
M&L for Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed
5
-
-
M&L for Form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof and sides of bands in walls, horizontal or sloping and similar work for rough finished concrete surface exc 10 cm but not exc 20 cm wide complete all as specified and directed.
12
-
-
Taking down of eves gutter,rain water pipes of any size or pattern including all fittings etc complete all as specified and directed.
450
-
-
S&F for PVC (SWR) pipes of 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and as directed.
250
-
-
S&F for PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls complete all as specified and as directed.
200
-
-
S&F PVC (SWR) bends ISI marked of radius 110 mm bore with access door complete all as specified and directed.
50
-
-
S & F PVC (SWR) bends of radius, 75 mm bore complete all as specified and as directed.
50
-
-
PVC (SWR) 110mm bore 'T' equal or unequal complete all as specified and directed.
20
-
-
M&L for preparation of old wall surfaces including brooming down or steel wire brushes, scraping down smoke soot moulds, moss and effeorescent salts and trading oil and greasy spot and applying one coat of white wash complete all as specified and as directed.
500
-
-
S&F in repairs galvanised, 2 strand , steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails staining bolts, incl securing or tying at crossings with and provn of galvanised mild steel wire, staples or steel pins, etc complete all as specified and as directed ( each line wire to be measured.
25
-
-
Restraining and resecuring existing galvanised, 2 strand , steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacings including making good staples etc. fixing to any type of standard rails staining bolts, incl securing or tying at crossings etc complete all as specified and as directed. ( each line wire to be measured.
50
-
-
Supply , laying and fixing of galvanized punched tape concertina coil of 600mm dia complete having galvanized spring steel core wire 2.5mm dia cold drawn steel, galvanized punched of low carbon steel having series of sharp barbs uniformly punched along its length 550 nos, barbs on periphery per revolution,crimped on steel spring core wire weight 9.20 kg each coil complete all as specified and directed.
50
-
-
Dismantling/ demolition posts or struts embedded in soil or concrete etc (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
200
-
-
Dismantling fencing wiremesh of any type complete all as specified and as directed.
50
-
-
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
3
-
-
Excavation in post holes (or similar holes) n exc 0.5 cum getting out in any type of soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm and covering and removal of surplus soil n exc 50m and making good surface complete all as specified and as directed.
10
-
-
M&L for PCC Type B-2 1:2:4 (using 40mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pillasters, butresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed.
2
-
-
M&L for sand filling under floors or in foundation incl watering and consolidation for laying inter-locking tiles complete all as specified and as directed.
5
-
-
M&L for 60mm thick machine pressed precast concrete interlocking paver, block with grey cement and pigment any shape and size conforming to IS-15658-2006 of M-40 Grade complete all as specified and as directed.
100
-
-
M&L chequred cement concrete tiles 20cm X 20cm X 25mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
100
-
-
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting, etc including embeding in concrete and similar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
400
-
-
Supply and fixing of chain link fencing of MS galvanised fencing of diameter of wire 3 mm thick and having aperature size of 75mm x 75 mm to any type of standard rails, straining bolts etc including provision of binding wire all as specified and as directed
200
-
-
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
30
-
-
S&F 12mm mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 5cm long complete all as specified and as directed.
25
-
-
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of syanthetic anamel paint over one coat of red oxide primer complete all as specified and as directed.
100
-
-
M&L preparation of new or previously untreated steel surfaces of any description, n exc 10cm in width and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed.
25
-
-
M&L for applying one coat of synthetic enamel paint on old decorated steel surfaces exc 10 cm width or girth including preparation of surfaces , complete all as specified and directed.
50
-
-
M & L for Providing 25mm thick (measured solid), precast cement concrete louvres and jallies, with 1:2:4 mix, type B0 (using 12.5mm graded stone aggregate) including all mouldings but excluding frame set in CM (1:6) complete all as specified and as directed.
20
-
-
M & L for Providing 40mm thick (measured solid), precast cement concrete louvres and jallies, with 1:2:4 mix, type B0 (using 12.5mm graded stone aggregate) including all mouldings but excluding frame set in CM (1:6) complete all as specified and as directed.
100
-
-
M&L for RCC type B 1, 1:2:4 (20mm graded agg) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
5
-
-
M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified.
25
-
-
M&L for expanded metal, cut to length, bent to shape required and tying with and incl annealed mild steel sire not less than 0.9 mm dia or fixing with galvinised steel staples supplied and fixed complete to wood or steel members n exc 4 kg per Sqm complete all as specified and as directed
40
-
-
S&F in repair vitreous china squatting pan white orissa pattern size 580 x 440mm with integral foot rests (excludig flushing cistern & flush pipe) with cast iron trap and make good to match with the existing surface of floor all as specified and directed by Engr-in-charge.
10
-
-
S&F in repair vitreous china wash down water closet pan including seat cover (pedestal pattern) white excluding flushing cistern & flush pipe including connection to out going pipe and flushing pipe complete all as specified and directed by Engr-in-charge.
10
-
-
S&F in repair 10 Ltr capacity PVC valveless shyphonic action type low level flushing cistern white with inlet, ball valve, float valve and handle incl bracket and flush pipe of low level of 32mm dia fixed to wall complete all as specified and as directed.
10
-
-
Dismantling floor, hearth or wall tiling in-cluding cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
51.5
-
-
M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick ( square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match ( in patches to match the existing colour /shed) over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
51.5
-
-
S&F in repair 100 mm/ 125mm dia mild steel chromium plated grating fixed on floor trap / nahani trap in Cement mortar 1:6 , all as specified and directed by Engr-in-charge.
30
-
-
S&F in repairs PVC (SWR) floor trap with grating 75 mm dia incl jointing with solvent cement complete all as specified and as directed.
5
-
-