Military Engineer Services Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date25 Sep 2024
Closing Date24 Oct 2024
Tender Amount₹ 30,00,000
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/maint To External Water Supply Ci And Gi Pipe Line, Sluice Valves, Gate Valves Connected Works At X Area At Afs Amla
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676515_1Bid Award Id
ViewTender No
8597/E8 OF 2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Excavation of trenches/pits (in any type of soil) n exc 6 mtr in length 2.5 Mtr wide and upto 2.5 mtr in depth with manually and getting out the leakage water by using diesel engine pump set/motor/manually for complete de watering from the tranches and repairing leakages in pipe line/NRV/Air Release valves in position for repairing the area/trench for jointing/repairing the leakages of any sizes upto 300mm bore of pipe with mechanical joint including returning filling in trenches all as directed.
14
-
-
Taking up or down (from wall/trench/floor) existing steel tubing and connections including cleaning with iron rod and wire brush for refixing or remove to MES store of following sizes: -
-
-
-
15 mm bore
220
-
-
20 mm bore
360
-
-
25 mm bore
335
-
-
40 mm bore
240
-
-
50 mm bore
325
-
-
80 mm bore
300
-
-
100 mm bore
220
-
-
Refixing of old steel tubing and connections in new or old position including cleaning internally and externally, cutting threading, any grade/make in trenches /on walls, celling, floors including all new type of fitting i.e. sockets, Tea, union, elbow etc all as sprcified and directed at site for following sizes: -
-
-
-
15 mm bore
40
-
-
20 mm bore
65
-
-
25 mm bore
50
-
-
40 mm bore
50
-
-
50 mm bore
45
-
-
80 mm bore
60
-
-
100 mm bore
40
-
-
Supply, Fixing and laying in repairs only GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all such as tee, bends union elbow reducer etc required at site: -
-
-
-
15 mm bore
180
-
-
20 mm bore
295
-
-
25 mm bore
285
-
-
40 mm bore
190
-
-
50 mm bore
280
-
-
80 mm bore
240
-
-
100 mm bore
180
-
-
Cutting Existing steel tubing in position for alteration or additions as per site (each cut measured) in any condition all as specified and directed of following size:-
-
-
-
15 mm bore
14
-
-
20 mm bore
20
-
-
25 mm bore
25
-
-
40 to 50 mm nore
20
-
-
Taking down and supply and fix gun metal valve, cast screwed down, hiogh pressure with iron wheel handle, screwed both ends for iron pipe or unions of the following size: -
-
-
-
50 mm bore
12
-
-
40 mm bore
10
-
-
25 mm bore
20
-
-
20 mm bore
40
-
-
15 mm bore
20
-
-
M&L for repairs/rectification of leakage in UG cast iron pipe lead joint by caulking lead wool/pig lead complete including excavation and earth work for exposing the joints and working space on the site, returning filling in and making good to the existing earth level of the surroundings after repair for the following sizes of pipes all as specified and directed.
Note: (a) Cost including excavation, returning, refilling
(b) In case of any leakage on the same joint contractor will be rectified without any financial effect with in six months.
-
-
-
do-but 80 mm dia bore
25
-
-
do-but 100 mm dia bore
20
-
-
do-but 150 mm dia bore
50
-
-
do-but 200 mm dia bore
35
-
-
M&L for Run leaded joint for spigot and socketed end of cast iron pipes of size 80mm dia bore all as specified and directed.
16
-
-
M&L for Run leaded joint for spigot and socketed end of cast iron pipes of size 100mm dia bore all as specified and directed.
12
-
-
M&L for Run leaded joint for spigot and socketed end of cast iron pipes of size 150mm dia bore all as specified and directed.
20
-
-
M&L for Run leaded joint for spigot and socketed end of cast iron pipes of size 200mm dia bore all as specified and directed.
30
-
-
Taking up cast iron or Ducting iron water mains (including all fittings), with spigot and socket, flange ends and lead joints including burnings out joints and recovering lead of following sizes:-
-
-
-
do-but 80 mm dia bore
135
-
-
do-but 100 mm dia bore
120
-
-
do-but 150 mm dia bore
50
-
-
do-but 200 mm dia bore
132
-
-
Re-laying Cast iron pipes with spigot and socket ends cenrifugally cast, Class LA in any length laid in trenchs of following sizes: -
-
-
-
do-but 80 mm dia bore
35
-
-
do-but 100 mm dia bore
35
-
-
do-but 150 mm dia bore
25
-
-
do-but 200 mm dia bore
75
-
-
Supply and fix cast iron pipes with spigot and socket ends cenrifugally cast, Class LA in any length laid in trenchs, tee, socket, elbow, uninion, site requirement including all items of following sizes: -
-
-
-
do-but 80 mm dia bore
100
-
-
do-but 100 mm dia bore
85
-
-
do-but 150 mm dia bore
25
-
-
do-but 200 mm dia bore
57
-
-
Cutting cast iron pipes and reducing to required length before laying all as specified and directed.
-
-
-
do-but 80 mm dia bore
8
-
-
do-but 100 mm dia bore
6
-
-
do-but 150 mm dia bore
4
-
-
do-but 200 mm dia bore
8
-
-
Screwing existing steel tubing for addition or alterations all as specified and directed at site for following sizes: -
-
-
-
15 mm bore
10
-
-
20 mm bore
10
-
-
25 mm bore
12
-
-
40 to 50 mm nore
12
-
-
S&F in repair 150 mm bore; M. S. pipe heavy duty Class 'C' ISI marked & including cutting, screwing welding etc. with all fittings as rtees, elbows reducers, flanges U Bolts, wire ropes etc. painting with one coat of primer and two coats of synthetic enamel paint complete all as specified and directed.
6
-
-
Supply and fix in repair non return valve of following size cast iron body with by-pass arrangement confirming to IS with jointing and jointing materials such as rubber gasket, nut, bolt, washer all as specified.
-
-
-
200 mm dia bore
2
-
-
150 mm dia bore
2
-
-
100 mm dia bore
2
-
-
80 mm dia bore
2
-
-
Taking down and supply and fixing Mechanical joint made out of MS sheet of thickness not less than 10 mm fabricated as per existing site requirement including long MS bolt, rubber gasket, cutting/fixing of pipe in position of any size CI/MS/AC pipe with the help of manually as well as mechanical T & P complete all as directed of following sizes: -
-
-
-
do-but 80 mm dia bore
2
-
-
do-but 100 mm dia bore
2
-
-
do-but 150 mm dia bore
3
-
-
do-but 200 mm dia bore
5
-
-
M&L for taking out sluice valves, top cover, spindle and broken/unserviceable check nut/gutka carry to workshop and refixing of sluice valve after servicing /maintenance /griding/greasing work to sluice valve parts, including replacement of gland packing, rubber sheet, nut bolt and washer of existing size complete all as specified and directed.
-
-
-
do-but 80 mm dia bore
4
-
-
do-but 100 mm dia bore
4
-
-
do-but 150 mm dia bore
5
-
-
do-but 200 mm dia bore
4
-
-
S&F in repairs 80mm size butterfly valve suitable for pressure rating PN 1.6 Mpa, conform to standard API609/BSEN 593 (BS 5155) complete with all accessories including taking down old butterfly valve all as specified and directed.
1
-
-
S&F in repairs 100mm size butterfly valve suitable for pressure rating PN 1.6 Mpa, conform to standard API609/BSEN 593 (BS 5155) complete with all accessories including taking down old butterfly valve all as specified and directed.
1
-
-
S&F in repair Rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed at site:-
Make: Sintex, Polycon, Jaipur, Rotex
-
-
-
500 Ltr cap
5
-
-
1000 Ltr cap
2
-
-
2000 Ltr cap
2
-
-
S&F in repair for PVC float valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass fenle and fixed in all as specified and directed of following size: -
-
-
-
15 mm bore
15
-
-
25 mm bore
30
-
-
25 mm bore
10
-
-
S&F in repair in position sluice valve confirming to IS 780/IS 14846- 2000 PN, 1.6 flanged and S/S spindles with cap & handle wheel opening arrangment of sizes given below with all nuts bolts, washer and rubber packing of existing size including taking down existing sluice valve and deposited to E/M store yard. Make: SIR, KIRLOSKAR, LEADER
-
-
-
do-but 80 mm dia bore
5
-
-
do-but 100 mm dia bore
4
-
-
do-but 150 mm dia bore
4
-
-
do-but 200 mm dia bore
3
-
-
do-but 250 mm dia bore
1
-
-
Material and labour CI fittings such as bends (any type radius and angle), tee pieces, single branch ‘Y’ Junction, double branch, cross (all sockets or socket & spigot), collars, caps & piugs etc for spigot and socketed CI pipes of size uoto 150mm bore all as specified.
130
-
-
Excavation in trench not exceeding 1.5 Mtr in depth and not exceeding 1.5 Mtr in width and getting out in soft/loose soil.
726.95
-
-
Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cms by using excavated soil.
656.35
-
-
Removing surplus spoil to a distance not exceeding 50 m and depositing where directed at level not 1.5 m above starting point.
70
-
-
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements