Military Engineer Services Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Machinery and Tools
Eprocure
Opening Date3 Sep 2024
Closing Date24 Sep 2024
Tender Amount₹ 4,04,00,000 
Notes
Download

Costs

Summary

Addn / Altn To Bldg No P-1217 At Af Stn Gwalior

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the contractor for Internal Electrifications as listed in Sch ‘A’ Part II.

1

-

1538787.48

... More
Sch A Part III (EXTERNAL WATER SUPPLY)

-

-

-

... More
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part III .

1

-

16966.64

... More
Sch A Part IV (EXTERNAL ELECTRIFICATIONS)

-

-

-

... More
Lump sum price worked out by the contractor for External Electrifications as listed in Sch ‘A’ Part IV.

1

-

2721797.13

... More
Sch A Part V (SEWAGE DISPOSAL)

-

-

-

... More
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part V.

1

-

92043.35

... More
Sch A Part VI (ROAD/PATH AND HARDSTANDING)

-

-

-

... More
Lump sum price worked out by the contractor for ROAD/PATH AND HARDSTANDING as listed in Sch ‘A’ Part VI.

1

-

762111.03

... More
Sch A Part VII (ADDN/ ALTN TO BLDG NO P-1217- B/R PORTION ONLY)

-

-

-

... More
Lump sum price worked out by the contractor for Addn/Altn to Bldg No P-1217 as listed in Sch ‘A’ Part VII

1

-

7160528.57

... More
Sch A Part VIII (RAMP WORK)

-

-

-

... More
Lump sum price worked out by the contractor for Ramp Work as listed in Sch ‘A’ Part VIII

1

-

55298.55

... More
Sch A Part IX (Miscellaneous Items of B/R and E/M)

-

-

-

... More
Taking down old serviceable flame proof light fittings / light fixture conventional type from wall surface / ceiling or any position, and re-fixing the same at location as directed by GE all as specified and directed.

29

-

-

... More
Taking down old serviceable flame proof/non-flame proof ceiling fans from ceiling and re-fixing the same at location as directed by GE all as specified and directed.

16

-

-

... More
Taking down old serviceable flame proof sockets/distribution boards from wall or from any position and re-fixing the same at location as directed by GE all as specified and directed.

49

-

-

... More
Taking down carefully serviceable DB any type/size disconnecting and re-fixing the same at location as directed by GE and making good disturbed surfaces complete all as directed.

2

-

-

... More
Taking down carefully serviceable MCB SP/SPN/Isolator of any rating/size and re-fixing the same at location as directed by GE.

60

-

-

... More
Taking down old and unserveasable sub main wiring of 2 or 3 runs of any sizes from any position including, depositing to MES store for safe custody and making good disturbed surface of wall ceiling etc all as directed.

1500

-

-

... More
Taking down carefully the serviceable indoor and outdoor units of wall-mounted Split Air Conditioners with 1.5/2 TR capacity and refixing the same in UPS Room and Spare part room incl servicing along with copper pipes and fittings complete all as specified and directed. Note:The cost of required copper pipe, insulation and other misc. items required for commissioning of AC is deemed to be included in the quoted rate.

4

-

-

... More
Supply & fixing of 4FT Dali Dimmable 40W IP40 LED Batten with system efficacy of 125LM/W and system lumen of 5000lm.LED fixture should have extruded aluminium housing and non-yellowing polycarbonate diffuser, with operating voltage range of 150V-270V, PF=0.95, CRI of min.80 with life criteria pof 75000br. hrs and surge protection of min 2.5KV fixture should have electrical insulation Class 1.

40

-

-

... More
Supply & fixing of wireless IoT System having BLE 5.2 AES 128 Bit encryption based 32 child DALI controller and analog 2 channel (0-10V) output, operates on 100-277 VAC, 10-30mA, 50Hz, DALI 2.0 protocol. Sensor input of 0-3V DC & 1mA. For analog dimming, It provides output voltage of 0-10V DC +/- 0.2V and 15mA per channel. For DALI output, it provides 12-20V DC and 160mA max for 32 DALI devices. An auxillary power output of 3.3VDC and 30mA. 0 - 100% dimming, device to device range 45m. Controller must control individually control standard DALI or Tunable DALI Drivers independently or combination of both. Operating temperature -20 to 50 deg celsius, surge protection 3kV. System shall support easy commissioning and configuration via Mobile Application along with user and site management features. Optional Cloud Application must be available for control and monitoring of the devices along with analytics reports. Mobile Application shall have features of individual & group control for On/off/dimming/ colour tuning / Scene Control / Device must have security key for commissioning and replacement for future.

4

-

-

... More
Supply & fixing of BLE 5.2 AES 128 Bit encryption based. Wireless battery powered 5-button wall switch that controls ON/OFF, intensity and CCT of an individual or group of luminaires. Operates on 3V DC input voltage in an ambient temperature of 0 to 50 deg Celsius and device to device range 45m. System shall support easy commissioning and configuration via Mobile Application along with user and site management features. Optional Cloud Application must be available for control andmonitoring of the devices along with analytics reports.

2

-

-

... More
Supply and fixing sheet metal enclosure powder coated three phases suitable for 100 to 125 Amp MCCB 4 pole IP 43 Metal Door VTPN DB 6 way double door with bus bar including grouting on the wall using screws and rawal plugs and making good disturbed surfaces to match with the existing colour of wall complete all as specified. Note: MCCBs & MCBs will be measured and paid separately

1

-

-

... More
Supply and fixing sheet metal enclosure powder coated three phases suitable for 100 to 125 Amp MCCB 4 pole IP 43 Metal Door VTPN DB 4 way double door with bus bar including grouting on the wall using screws and rawal plugs and making good disturbed surfaces to match with the existing colour of wall complete all as specified. Note: MCCBs & MCBs will be measured and paid separately

1

-

-

... More
Supply and fix ETPN 6-way distribution board with IP-43 protection as per IS 8623 With 100 A busbars, neutral bar, and earth bar with provision for FP RCCB / MCB / Isolator as incomer and SP MCBs as outgoing. Note:- MCB TPN & MCB SP will be measured and paid separately

4

-

-

... More
Supply and fix ETPN 4-way distribution board with IP-43 protection as per IS 8623 With 100 A busbars, neutral bar, and earth bar with provision for FP RCCB / MCB / Isolator as incomer and SP MCBs as outgoing. Note:- MCB TPN & MCB SP will be measured and paid separately

5

-

-

... More
Supply and fix MCCB 250 Amps, 4 pole, in and including SS Sheet metal enclosure of any reputed make wall mounted with inbuilt neutral link IP-30 protection complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
Supply and fixing MCCB 200 Amps, 4 pole, in and including SS Sheet metal enclosure of any reputed make wall mounted with inbuilt neutral link IP-30 protection complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
Supply and fixing MCCB 40 Amps, 4 pole, in and including SS Sheet metal enclosure of any reputed make wall mounted with inbuilt neutral link IP-30 protection complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Supply and fixing LT, 1100 volts grade, PVC insulated, unsheathed, stranded copper conductor cable, FRLHS, cable, 35 Sqmm x 4 runs for RYBN in proper colour code alongwith green colour conductor, FRLHS, 35 Sqmm one run for earthing in and including Rigid Non-metalic PVC conduit of suitable size with proper fixing arrangement on wall surface/ceiling complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Supply and fixing LT, 1100 volts grade, PVC insulated, unsheathed, stranded copper conductor cable, FRLHS, cable, 50 Sqmm x 4 runs for RYBN in proper colour code alongwith green colour conductor, FRLHS, 50 Sqmm one run for earthing in and including Rigid Non-metalic PVC conduit of suitable size with proper fixing arrangement on wall surface/ceiling all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Supply and fixing , 1100 volts grade, PVC insulated, unsheathed, multi stranded copper conductor cable, FRLHS twin core cable, 1.5 Sqmm concealed in wall for control wiring of dimmer lamps all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Supply and laying PVC conduit medium grade 25 mm dia concealed in wall for drawing of AFNET cables and communication cables complete all as specified and directed by Engineer-in-Charge.

400

-

-

... More
Supply and fixing LT, 1100 volts grade, PVC insulated, unsheathed, stranded copper conductor cable, FRLHS, cable, 70 Sqmm x 4 runs for RYBN in proper colour code alongwith green colour conductor, FRLHS, 70 Sqmm one run for earthing in cable tray complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Supply and fixing in wall concealed with metallic flush box suitable for fixing R-45 communication port complete all as specified and directed.

25

-

-

... More
Supply and fixing wall mounted emergency lamp 10 Watt along with battery complete all as specified and as directed

10

-

-

... More
Supply and fixing super imposed metal Cable trays size 150mm wide with an edge of 50 mm, 14SWG fixed laterally on the wall , complete with all fittings as required as per site.

400

-

-

... More
M&L for Rotational moulded polyethylene water storage tank eight layer of 10000 Ltr Capacity cylindrical vertical with closed top each hoisted and fixed in position with and including stagging base & foundation. Outer size of stagging base & foundation is 3.0mx3.0mx2.0m and made of Brick work with and including plaster finishes etc complete all as specified and directed by Eng-in-charge.

2

-

-

... More
Construction of brick massonery valve pit internal dimension 60x60x60cm with subclass B bricks in CM (1:6) and 15mm thick plastering in CM (1:4) inside the chamber and on the external portion exposed above ground level, 3mm thick MS sheet cover welded arouds with ms flat iron of size 40x6mm and ms angel iron frame of size 40x40x6mm with locking arrangement and painting with tow coats of syhthetic enamel paint over acoat of red oxide primer including necessary earth allas specified

1

-

-

... More
Cutting CI pipe in position for insertion of new Tee 80 X 80 X 50 for branch connection of 50 mm dia pipe including necessary fittings and fixtures. Note: Necessary excavation, return refilling, fittings and fixtures are included in the quoted rate

1

-

-

... More
Cable jointing kit for 1.1 KV grade cable for straight-through Heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminum conductor cable of size 240 sqmm.

4

-

-

... More
M&L for Maintenance free earthing with 17.2mm dia minimum 3m length copper coated (Minimum 200 Micron) earth electrode with 65 mmx10mm, 3mm thickness copper coated flat with holeson the top of the copper bonded rod for connecting the copper earth strip. The cost includes drilling a hole of 85mm in diameter using mechanical / hydrolic boring /drilling. The copper bonded electrode to be placed in the hole and surrounding area shall be filled with EEM (Earth Enhancing Material) with the suggested proportion of excavated soil. The copper bonded electrode is to be connected with 25 mmx3mm copper strip using a copper / brass nut bolt of size 8 mm with copper washer near top end of earth electrode is to be connected to copper strip 25mmx3mm as main earthing lead using copper brass bolt nuts washer chech nuts and strip firmly, earth lead to be connected to earth test point made of phosphorous broze / gunmetal of size 75mmx75mmx25mm drill and screwed including 03No 8mm dia 25mm long hexagonal head screw. PCC 1:3:6 type C-1using 20mm graded stone aggregate for inspection chamber (earth pit) of size 300mmx300mminternal with 100mm thick at side i.e total 500mmx500mm outer side & 300mm depth with precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick cover reinforced with 8mm dia TMT bars 3 No both way with 12mm dia round bar handle etc including necessary earthwork complete all as specified and directed. Note: (i)The achieved earth value shall be less than 01ohm. The cost of calculating the earth resistivity of the particular site is deemed to be included in the quoted rate. The quantity of earthing for achieving an earthing value less than 01ohm will be decided by the value earth resistivity. (ii) The cost of earth leads up to and including 7.5 meter only from the top of earth electrode are deemed to be included under this item and additional earth lead, if any required shall be measured and paid for separately under appropriate item of Sch 'A' (iii) The earth enhancing material (EEM) shall comply with the specification as mentioned in PS. Relevant test certificate as per EC62561-7 & other standard should be tested at any recognized National Test Laboratories like CPRI, ERDA, ERTL and MSME as approved by GE. The list of tests shall be done as given in PS. (iv) The resistance value shall be recorded in the presence of the User and Engr-in-Charge and value shall be sustained for a period of a minimum of 10 Years. The contractor shall a Certificate from OEM in this connection.

6

-

-

... More
Supply, installing, testing and commissioning of factory made LT Panel board, indoor type, of suitable size platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 1000 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 54 class protection and made of 2.0 mm CRCA MS sheet and 60x60x6mm thick angle iron frame work, powder coated finish RAL 7032 SIEMENS GRAY STRUCTURE after the seven tank surface treatment, front /back opening type, with aprons for cable entry, and fixing 2 Nos. danger notice plate of size 20x15 cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest ground level. complete all as specified and directed including connections of all out going/in coming existing cables of sizes 25 to 400 sqmm by drawing / digging out cable from loops in trenches/ ducts out side the Bldg. inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size Aluminium lugs for terminal connections of cables, necessary PCC foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate/ glands & The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old Skelton type panel any type and size complete all as specified and directed by Engr-in-Charge, The scope of work includes the following: Items (Note:- All type Test certificates and design Verification with switch gears (MCCB) as per confirming to IS/IEC: 61439/2011 Part-1 and part -2 with short circuit test at with 4000 Amps 65 KA, should be submitted by the contractor before executing the job.)

1

-

-

... More
A) BYPASS SECTION:- ON- LOAD Change over Switch 4P, 630 Amps -01 No.On indicating Neon - 02 Sets B) AMF 400 KVA, SECTION:- TPN Aluminium BUS BAR 1000 Amps - 01 Set MCCB 630 Amps FP, 50KA, TMR, along with suitable spreader links & ROH -02 Nos. CONTACTOR, 4 Pole,415 V of suitable capacity - 02 Nos. Digital MFM V.A.F. +PF -01 No. CT : 630/5 A-03 Nos. RYB & ON indicating Lamp LED type 240 V AC-06 Nos. LOAD ON indicating Lamp LED type 240 V AC-02 Sets. MCB SP 6A, -06 Nos. Auto / Manual selector Switch-01 No. DC Ammeter & voltmeter ( for battery charger) - 01 Set. Amf logic relay, Battery Charger & accessories - 01 Set. Necessary wiring of suitable size. - 01 Set. C) POWER SUPPLY DISTRIBUTION SECTION:- INCOMING:-Busbar 4 Pole, Aluminum, 1000 Amps - 01 Set. MCCB, 630 A, 4 Pole, 415 volt, 50 KA, ICS= 100% ICU with ROH & Spreader Link - 01 Set. METERING:- MFM VAF+ PF - 01 No. CT : 630/5A - 01 set. LED indicating lamps (RYB)-01 Set. OUTGOING:- MCCB 4 pole 415 volt, 400 Amps, 36 KA, -01 No.(Adjustable thermal magnetic type)(For 1217 Bldg Light). MCCB 4 pole 415 volt, 250 Amps, 36 KA, -01 No..(Adjustable thermal magnetic type) (For proposed AC Plant) Space only for spare MCCB -01 No.

-

-

-

... More
Taking down carefully the serviceable LT UG cable 240 Sqmm 3.5 core in position and relaying/shifting the same at the directed location complete all as specified and as directed. Note: 1. Necessary excavation, return refilling, sand, and PCC cable covers will be measured and paid separately. 2. Cable jointing Kits, and cable if required at the site will be measured and paid separately.

200

-

-

... More
M & L for disconnecting the existing 240 Sqmm 3.5 core LT UG cables from the LT Panel and fixing both the Cables at outgoing of AMF Panel along with all necessary connecting materials complete all as specified and as directed.

1

-

-

... More
Supply install testing and commissioning ISOLATION TRANSFORMER Indoor type- suitable for IP 23 enclosure, 415 volts at no load AC 3 phase 50 Hz capacity 160 KVA, core type double copper wound ONAN cooled Oil immersed delta connected on primary side and star connected on secondary side in accordance with vector symbol DYN-II (vector group) with neutral brought out on secondary side (LV side) and having tapping at +5% in steps of 2.5% by means of off circuit tap link board. The maximum temperature rise 115 degree calsius by winding resistance method after continuous full load on an ambient temp of 50 degree Celsius. The transformer shall be confirming to IS: 1180: 2014 and shall comprise of the following:- (a) Rating and diagram plate. (b) Two earthing terminals in two side. (c) Lifting lugs .(d) Off circuit link board. (e) Base channel with Bi- directional Rollers. (f) Danger board (g) 100 mm dial type thermometer. (h) Cable entry boxes etc complete as reqd.

1

-

-

... More
Supply, commissioning erecting and testing complete of OEM manufactured, static silient (sound proof enclosure) Disel Engine driven Generating set of capacity 400 KVA, water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, of adequate capacity for 8 hrs running fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Gwalior (capacity of engine, alternators shall worked out taking all derating factors into consideration) including foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height) as per manufacturer recommendation, anti-vibration pads complete all as specified and directed, confirming to emision norms (No + HC 4.0,Gm/kwhr CO 3.5 gm/kwhr, PM 0.2 gm/kwhr, smoke limit 2.7 m -1) including all feature to comply with latest CPCB 4+ guidelines and comprising of followings:- DIESEL ENGINE: Diesel engine 1500RPM, direct injection, multi cylinders, four stroke, conforming to conforming to IS:100001/ISO3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 400 KVA at outdoor atmospheric conditions at Gwalior ( Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:- (i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level (v) Radiator cooling (vi) Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter and fuel houses (ix) Fuel injection pump (FIP) (x) Fan and water pump assesembly (xi) Lub oil filter and pump (xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid bty as per manufacturer recommendation including inter connecting cables/leads with terminals complete with starting/stopping switch voltmeter, etc 01 set (xiii) Engine safety shut down system against low oil pressure and high water pressure (xiv) Exhaust gas driven turbo charge (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine maintenance manual with spare part list (xviii) Suitable designed acoustic enclosure as per CPCB regulations (xix) Any other item not included / specified but is a standard design of the manufacturer/required for commissioning/satisfactory operation of DG set.

1

-

-

... More
Engine instrument panel : Engine instrument panel shall comprising of the following:- (i) Starting on /off switch. (ii) water temp auge. (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure. ) Any other item not included/specified but is a standard design of the manufacturer. ALTERNATOR : shall be self excited, self regulated, brush less for 400KVA continous operation at the speed of 1500RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS-4722 complete-01 No. Note:- Alternator should be able to deliver output rating at actual site condition. Common fabricated base frame for engine and alternator made from structural channel, jerk proof PCC 1:2:4 mix type B1 foundation including adequate number of suitable anti-vibration pads all as per manufacture recommendations is deemed to be included in the unit rate quoted by the contractor. Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per engineering practice complete all as specifided and directed. (i) Hour run meter. (ii) Any other item not included/ specified but is a standard design to the manufacturer.

-

-

-

... More
M&L for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to galvanised iron strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 40 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, PCC chamber using PCC(1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed. Note :- (i) GI strip and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for MS sheet of size 300x300x3mm th, fixed with necessary nuts and bolts on angle iron of size 40X40x5mm, 60cm long and grouted with PCC block of size 200x200x250mm(PCC 1:3:6 using 20mm grade stone aggregate including necessary earth work for marking the result and purpose.

2

-

-

... More
M&L for earthing with copper plate 600x600x3.15mm thick, buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to copper stip 20x3mm by means of copper/brass nut, bolt duly brazed earth strip protected with 32mm bore medium grade GI pipe from electrode and upto and including watering pipe medium grade 15mm bore GI pipe including funnel, wire mesh, providing alternate layer of 150mm th each charcoal and salt upto 1.2mtr, PCC chamber using PCC (1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed. Note :- (i) Copper strip and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for MS sheet of size 300x300x3mm th, fixed with necessary nuts and bolts on angle iron of size 40X40x5mm, 60cm long and grouted with PCC block of size 200x200x250mm(PCC 1:3:6 using 20mm grade stone aggregate including necessary earth work for marking the result and purpose.

2

-

-

... More
M&L for 30 to 35mm thick Duct flooring of Anti Static laminated Steel cementitious Pannel with PVC edge beading of size 600x600mm (10 % of total number of tiles used should be perfoated tiles ) with grid system made of Padestal assembly MS Zinc coated tubular pipesfor 600mm finish floor height, Padestal base plate, Head assembly, check nut for level adjustments, GI olded stringers with embossed ribs on 3 sides , jack plate, Base plates fixed to floor with fastners with complete installation by manufacturer complete all as specified and directed. Concentrated load capacity 362Kg and UDL =1400 Kg /Sqm. Note: The work should be executed by specialized manufacturers agents.

74.23

-

-

... More
M&L for prepration of ceiling, Floor and wall surface over 10cm girth or width,and applying two coas of anti dust epoxy Black or Dark grey satinated colour over a coat of primer complete all as specified and directed.

995.46

-

-

... More
S&F as in repair window roller curtains, zebra blinds, polyresin inside/outside mount type as per site condition with complete installation all as specified and directed by Engr-in Charge. Note : Window opening size will be measured, Shades and pattern as approved by GE & User.

38.25

-

-

... More
S&F UPVC luxury casement sound proof side Hung (Tilt &Turn type) windows and frame with double toughned glass glazing 65mm/C65PS3/Z-SASH, DG INS, TGH (5T+10+5T) internal plain and external tinted with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc complete all as directed.

15.53

-

-

... More
S&F UPVC luxury casement sound proof fixed type windows and frame with double toughned glass glazing 65mm/ C65PS3/Z-SASH, DG INS, TGH (5T+10+5T) internal plain and external tinted with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc with lock and key complete all as directed.

38.03

-

-

... More
S&F 4mm thick ACP (Aluminum composite pannel) for fixing to aluminum doors /partitons complete all as specified and directed.

82.5

-

-

... More
S&F UPVC sound proof door shutter with frame with double toughned glass glazing 65mm/C65PS3/ Z-SASH, DGU INS, TGH (5T+10+5T) with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc complete all as directed.

110.62

-

-

... More
S&F Steel Track roller heavy duty for Sliding of Door complete all as specified and as directed

24

-

-

... More
Supply only powder coated aluminium snap beading complete all as specified and directed .

44

-

-

... More
S&F 30mm thick Acoustic peforated prelam PVC false ceiling panel made of 4.5/5mm thick PVC perforated sheet of size 600mmx600mm on 25mm glasswool/rockwool pasted with perforated sheet with suitable adheisive. The panel is inserted in a frame made of GI 'T' & 'L" section of size (25mx25mm) in square type grid of 600mmx600mm the false ceiling 4mm dia GI suspender of suitable size and dash fastners to be provided @ 1.20 mtr distance complete all as directed. Note:- Quoted rates inclusive of removing all electric fittings and fixtures and refixing the same at its positions after finishing false celing work.

895.34

-

-

... More
S&F 18mm thick Rajshri PVC Celuka ply of both side laminated to make kitchen cabinet shutter/drawer front shutters complete as per specifications and as directed by the Engr in charge.

8.74

-

-

... More
S&F auto closing hinges 35mm size including magnetic system and openable at 110 degree for kitchen cabinets shutters.

16

-

-

... More
S&F Stainless steel handles 100mm size or kitchen cabinets shutters as per specifications and as directed by the Engr in charge.

8

-

-

... More
M&L for under deck insulation with a resin bonded fibre glass wool confirming to IS 8913, density 24 Kg per Cubic meter, 60 mm thick, wrapped in 200+/- 20 GSM virgin polythene bags fixed to ceiling with matellic cleat 50x50x3mm at 60 cm centre to centre and wire mesh of 12.50mm x 24G wire complete all as specified and directed by Engineer-in-Charge.

527.91

-

-

... More
Deduct Schedule of Credit of amount Rs 82518.00 as per credit schedule attached

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.