Central Public Works Department Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Central Public Works Department - CPWD Tender
Civil And Construction
Pipe Line Project
GEM
Opening Date1 Mar 2024
Closing Date13 Mar 2024
Tender Amount₹ 94,12,723
Costs
EMD
₹ 1,88,254Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/4720635Bid Award Id
ViewTender No
GEM/2024/B/4720635Tender Authority
Central Public Works Department ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
nit_for_fire_pump_gem_2024-03-01-18-28-40_7c3417813faef0bfd0a372e4af6ef6db.pdf
boq_item_sample_file_2024-03-01-18-28-40_172e6ef950336c5e851032b65deb4baa.csv
BOQ Items
SITC of Electrical control panel Incomings 630A 50kA 4 Outgoings for Main Fire Pumps and Jockey Pump , As per BOQ specification
1
-
-
Providing laying T and C of C class heavy duty MS pipe 25 mm dia , As per BOQ specification
18
-
-
Providing laying T and C of C class heavy duty MS pipe 50 mm dia , As per BOQ specification
18
-
-
Providing laying T and C of C class heavy duty MS pipe 80 mm dia , As per BOQ specification
12
-
-
Providing laying T and C of C class heavy duty MS pipe 100 mm dia , As per BOQ specification
12
-
-
Providing laying T and C of C class heavy duty MS pipe 150 mm dia , As per BOQ specification
24
-
-
Providing laying T and C of C class heavy duty MS pipe 200 mm dia wall thickness 6.3 mm , As per BOQ specification
36
-
-
Providing laying T and C of C class heavy duty MS pipe 250 mm dia wall thickness 6.3 mm , As per BOQ specification
2
-
-
Supplying fixing T and C of Double flanged sluice valve 50 mm dia , As per BOQ specification
2
-
-
Supplying fixing T and C of Double flanged sluice valve 80 mm dia , As per BOQ specification
4
-
-
Supplying fixing T and C of Double flanged sluice valve 100 mm dia , As per BOQ specification
1
-
-
Supplying fixing T and C of Double flanged sluice valve 150 mm dia , As per BOQ specification
9
-
-
Supplying fixing T and C of Double flanged sluice valve 200 mm dia , As per BOQ specification
4
-
-
Supplying fixing T and C of Double flanged sluice valve 250 mm dia , As per BOQ specification
2
-
-
Providing installation T and C of non-return valve 80 mm dia , As per BOQ specification
2
-
-
Providing installation T and C of non-return valve 100 mm dia , As per BOQ specification
1
-
-
Providing installation T and C of non-return valve 150 mm dia , As per BOQ specification
3
-
-
Providing installation T and C of non-return valve 200 mm dia , As per BOQ specification
2
-
-
Providing installation T and C of stainless steel Ystrainer. 200 mm dia , As per BOQ specification
2
-
-
Providing installation T and C of stainless steel Ystrainer. 150 mm dia. , As per BOQ specification
3
-
-
Providing installation T and C of stainless steel Ystrainer. 80 mm dia , As per BOQ specification
2
-
-
Providing and fixing of gun metal fire Brigade Suction Hose coupling , As per BOQ specification
1
-
-
Supply and fixing of air vessel made of 250mm dia 10 mm thick MS sheet , As per BOQ specification
1
-
-
Providing and fixing 150 mm diameter MS Class C for diesel engine exhaust pipe , As per BOQ specification
40
-
-
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators 80 mm dia , As per BOQ specification
4
-
-
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators 100 mm dia , As per BOQ specification
2
-
-
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators 150 mm dia , As per BOQ specification
6
-
-
Supplying and laying of Power cable 3.5 core 300 sq mm aluminium conductor armoured cable , As per BOQ specification
370
-
-
Supplying and laying of Power cable 3.5 core 150 sq mm aluminium conductor armoured cable , As per BOQ specification
120
-
-
Supplying and laying of Power cable 3.5 core 50 sq mm aluminium conductor armoured cable , As per BOQ specification
120
-
-
Supplying and drawing following sizes of 2 x 1.5 sq mm , As per BOQ specification
30
-
-
Supplying and drawing following sizes of 4 x 1.5 sq mm , As per BOQ specification
20
-
-
Supplying and drawing following sizes of 6 x 1.5 sq mm , As per BOQ specification
20
-
-
Supplying and drawing following sizes of 4 x 2.5 sq mm , As per BOQ specification
20
-
-
Supplying and drawing following sizes of 3 x 4 sq mm , As per BOQ specification
20
-
-
Supply and Installing following size of 100 mm width X 50 mm depth X 1.6 mm thickness , As per BOQ specification
20
-
-
Supply and Installing following size of 150 mm width X 50 mm depth X 1.6 mm thickness , As per BOQ specification
20
-
-
Supply and Installing following size of 225 mm width X 50 mm depth X 1.6 mm thickness , As per BOQ specification
40
-
-
Supply and Installing following size of 300 mm width X 50 mm depth X 1.6 mm thickness , As per BOQ specification
60
-
-
Providing laying and fixing following dia RCC pipe NP2 class light duty 250 mm dia , As per BOQ specification
60
-
-
Supply and Installing following size of 300 mm dia , As per BOQ specification
60
-
-
Foundations footings bases of columns etc for mass concrete , As per BOQ specification
400
-
-
Thermo Mechanically Treated bars of grade Fe500D or more , As per BOQ specification
5000
-
-
P and L in position cement concrete of specified grade 1 1.5 3 1 cement 1 5 coarse sand Zone III , As per BOQ specification
85
-
-
Earth work in excavation by mechanical means All kinds of soil , As per BOQ specification
300
-
-
Providing and Fixing of pressure switch in MS pipe line , As per BOQ specification
5
-
-
Providing and fixing in position the industrial type pressure gauge , As per BOQ specification
8
-
-
Supply and Installation of suitable capacity monorail with chain pulley , As per BOQ specification
1
-
-
Indian Standard Medium weight Beams 300 , As per BOQ specification
20
-
-
SITC of De Watering pump with Auto Operation and control panel 2HP capacity , As per BOQ specification
2
-
-
SITC of Flange end pressure relief valve PRV Safety Valve , As per BOQ specification
1
-
-
SITC of H U connection between existing fire hydrant line and new fire hydrant line , As per BOQ specification
2
-
-
SITC of tube axial fans 2500 CFM 30mm WG Exhust Air Fan , As per BOQ specification
1
-
-
SITC of fabricated Thickness 0.80 mm sheet , As per BOQ specification
36
-
-
Supply installation testing and commissioning of GI volume control duct damper , As per BOQ specification
5
-
-
Fresh Air Fan Panel Incoming 1 nos 63A 35 KA 3P MCCB , As per BOQ specification
1
-
-
Supplying and fixing of following ways surface recess mounting, vertical type 415 volts , As per BOQ specification
1
-
-
Supplying and fixing 5 amps to 32 amps rating 240 415 volts C curve Single pole , As per BOQ specification
12
-
-
Supplying and fixing 5 amps to 32 amps rating 240 415 volts C curve Triple pole and neutral , As per BOQ specification
1
-
-
Earthing with GI earth pipe 4 point 5 meter long 40 mm dia , As per BOQ specification
2
-
-
Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick , As per BOQ specification
2
-
-
Providing and fixing 25 mm X 5 mm GI strip on surface , As per BOQ specification
80
-
-
Providing and fixing 6 SWG dia GI wire on surface , As per BOQ specification
100
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements