Military Engineer Services Tender
View complete overview of Lakshadweep MES Tender
Military Engineer Services - MES Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date20 Dec 2023
Closing Date18 Jan 2024
Tender Amount₹ 27,74,000
Costs
EMD
₹ 55,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_633624_1Bid Award Id
ViewTender No
8382/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
ACCOUSTIC ENCLOSURE : Specifically designed to meet stringent MoEF/CPCB norms of 75 dBA@1mtr at 75% load under free field condition. The accoustic enclosure is made of CRCS sheet in munsel green shade and a structural/sheet metal base frame painted in black. The hot chamber of the canopy shall be properly insulated by mineral wool and aluminium foil to prevent excess heat radiation and necessary space heaters as recommended by OEM. BASE FRAME : The Diesel engine and alternator shall be perfectly aligned and assembled dynamically balanced on a sturdy, fabricated, welded construction, channel iron base frame. Base frame shall have lifting provisions and predrilled holes suitable for grouted foundation. Flooring/ foundation should be RCC (Reinforced Cement Concrete) and firm & level.
AMF Panel: Fabricated sheet cubicle type powder coated with front hinged doors, dust and vermin proof totally enclosed for indoor type including MFM, LED indication lamps, selector switches, controller, auto/manual switch, contactors of suitable rating as per OEM, internal wiring with suitable size, relays, CTs of suitable rating, aluminium bus bar suitable for 125 KVA DG set complete all as recommended by OEM.
-
-
-
Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead 32x6 mm size, by means nut, bolt, check nuts and washer of galvanized iron and 32x6 mm as earth lead protected by provision of GI light grade pipe 40mm bore incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point all as specified including testing on completion. complete all as specified and as directed by Engineer-in-Charge.
6
-
-
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting soft/loose soil for laying of cables/pipes/erection of poles etc. complete all as specified and as directed by Engineer-in-Charge.
48
-
-
Returning filling in, with excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cms complete all as specified and as directed by Engineer-in-Charge.
34
-
-
Removing excavated materials/surplus soil exceeding 250m and n. exc. 500m and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
14
-
-
M&L for sand cushioning with Sand in two layer,first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable including consolidation of each layer complete all as specified and as directed by Engineer-in-Charge.
Note: Thickness of sand cusioning shall be measured after punning. All as specified and directed by Engr-in-Charge.
14
-
-
supply and Laying unreinforced precast concrete cable cover class LV 1 flat size of size 250x150x40 mm for LT Cable all sizes complete all as specified and as directed by Engineer-in-Charge.
1200
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core complete all as specified and as directed by Engineer-in-Charge.
200
-
-
M&L for cutting the existing road for laying of cables and pipes in hard standing of size and pavings n.exc 15 cms thickness (below ground level) for road cutting channel to lay pipes complete all as specified and as directed by Engineer-in-Charge.
0.5
-
-
Material and labour for PCC 1:3:6 type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
0.5
-
-
Supply and laying 80mm dia GI Pipe (ISI Marked) medium grade for cable protection in road crossing as ordered of complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply & Install, test and commission factory made outdoor type/Floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of size (1700x2050x700mm) with 400 Amps rated copper busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer, LT feeder pillar box shall be manufactured by CPRI approved manufacturer, including PCC foundation to accmoomodate complete all as specified and as directed by Engineer-in-Charge. Comprising of following:-
(i) On Load change over switch TPN 415V 400A ,50kA-01 (incoming)
(ii) MCCB TPN 415V 100A 36kA-04 & 63 Amps 25 KA -04 (outgoing)
(iii) Digital voltmeter 0-500 V 01 No
(iv) Digital ammeter with Cts 250 amps- 01 No
(v) Tamper proof digital KWH enery meter with CTs - 01 No
(vi) Indicator lamp LED type 240V AC (RYB) - 01 set