Military Engineer Services Tender

View complete overview of Lakshadweep MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Oct 2024
Closing Date16 Nov 2024
Tender Amount₹ 44,07,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 02.00 here in before but one 3 pin 5 amps switch socket on independent board

20

-

-

... More
All as per item No 02.00 here in before but with cable size 2.5 Sqmm and 2.5 Sqmm as earthwire for 3/5 pin, 15/16 amps socket outlet independent board

20

-

-

... More
S & F modular switch, 1 way, 6A, 1 module complete all as specified and as directed .

73

-

-

... More
S&F modular socket, 6A, 2/3 pin combined 2 module complete all as specified and as directed .

30

-

-

... More
S & F modular switch, 1 way, 16A, 1 module complete all as specified and as directed .

30

-

-

... More
S&F modular socket, 6/16A, 2/3 pin combined 2 module complete all as specified and as directed .

30

-

-

... More
S & F in replacement of switch piano flush type single pole one way 5 amps 230 volts ISI marked complete all as specified and as directed .

40

-

-

... More
S & F in replacement of switch socket combination flush type universal 2 in 1, 3 pin 5 Amps 230 volts ISI marked complete all as specified and as directed .

20

-

-

... More
S & F in replacement of ceiling rose 3 terminal 5 Amps 230 volts ISI marked,PVC/Polycarbonate, insulated body complete all as specified and as directed .

45

-

-

... More
S & F in replacement of Fan step Regulator, 120 Watt, 2 module, hum free complete all as specified and as directed .

56

-

-

... More
S&F in replacement of modular bell push, 6 A, 1 module complete all as specified and as directed .

10

-

-

... More
S & F in replacement of bell electric ding dong AC 230 V single pole complete all as specified and as directed .

10

-

-

... More
S & F in replacement of LED light fitting batten fitting 1x 20W, 220V, 4 feet, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed .

500

-

-

... More
S & F in replacement of LED light batten fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed .

331

-

-

... More
S & F in replacement of LED bulb 10w retrofit type to fit in lamp holder/bulk head fittings complete all as specified and as directed .

90

-

-

... More
S & F in replacement of LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed .

25

-

-

... More
S & F in replacement of street light brackets made out of 40mm bore GI tubing, light grade, 1.5m long, bent to required shape, including necessary bending, welding, etc fixed with 2Nos. clamps made out of 32x5mm GI strip including necessary drilling holes, screws, nuts, bolts, etc complete all as specified and as directed .

20

-

-

... More
S & F in replacement of LED bldg security light fitting 30 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed .

35

-

-

... More
S & F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp, 240 V MCB complete all as specified and as directed

4

-

-

... More
Supply only 1.5 Sqmm Flame Retardant Low Smoke & Halogen (FR-LSH) single core PVC Insulated Industrial grade copper conductor (Unsheathed) Flexible Cable, 1100 Volt Conforming to IS 694 complete all as specified and as directed

360

-

-

... More
All as per Item No 23.00 here-in-before but 2.5 Sqmm.

360

-

-

... More
All as per Item No 23.00 here-in-before but 4 Sqmm.

360

-

-

... More
S & F in replacement of MCB SP, 6 amps to 32 amps, 240 volts,10 KA complete all as specified and as directed

50

-

-

... More
S & F in replacement of MCB SPN 16 amps to 32 amps, 240 volts,10 KA complete all as specified and as directed

10

-

-

... More
S & F in replacement of MCB TPN/FP 40 Amp to 60 Amp 415 V, 50 Hz, complete all as specified and as directed

12

-

-

... More
S & F in replacement of in repair single door MCB DB TPN 4 Way 415 V , 50 Hz, complete all as specified and as directed

2

-

-

... More
S & F in replacement of single door MCB DB SPN 4 Way 240 V , 50 Hz with 200A rated copper busbar complete all as specified and as directed

4

-

-

... More
S & F in replacement of single door MCB DB SPN 8 Way 240 V , 50 Hz, with 200A rated copper busbar complete all as specified and as directed

4

-

-

... More
S & F in replacement of distribution board VTPN 4 way vertical type double door 415 Volts as per IP-43 with provision for MCCB upto 160 Amps as incomer and SP/SPN/TPN MCB as outgoing and electrically connected up complete all as specified and as directed

2

-

-

... More
Taking down existing unserviciable ceiling fan /exhaust fan of any type and rewinding the same with fine enamelled copper conductor and refixing at same location and testing complete all as specified and as directed .

60

-

-

... More
S & F in replacement of condenser of 2.5 MFD complete all as specified and as directed .

75

-

-

... More
S & F in replacement of condenser of 1.5 MFD complete all as specified and as directed .

10

-

-

... More
Taking down the unserviceable Electric geyser 25 Ltrs capacity and transporting to work shop for repairs/replacement of unserverviceable items such as heating coil, thermostat, copper container, indicating lamp to match the existing geyser complete all as specified and as directed . Note : Cost for replacement of items will be measured and paid under respective items as Supply only

4

-

-

... More
Supply only heating coil suitable for Electric geyser 25 Ltrs capacity

4

-

-

... More
Supply only thermostat suitable for Electric geyser 25 Ltrs capacity

4

-

-

... More
Supply only inner container made of copper suitable for Electric geyser 25 Ltrs capacity

4

-

-

... More
Maintenance and servicing of split type 1.5/2 Ton AC including cleaning filter, washing with soap solution after removing from site and refixing the same complete all as specified and as directed .

34

-

-

... More
S & F in replacement of hermitically sealed outdoor compressor unit including brazing/welding and leakage testing after completon of job for 1.5 Ton Split type AC complete all as specified and as directed .

15

-

-

... More
All as per item No. 41.00 here in above but for 2.0 Ton capacity

3

-

-

... More
M & L for gas charging including comissioning and testing in split AC 1.5/2 Ton complete all as specified and as directed .

34

-

-

... More
S & F in replacement of condensing coil copper including soldering with existing system for 1.5/2 Ton AC complete all as specified and as directed .

15

-

-

... More
S & F in replacement of outdoor fan motor for 1.5 ton AC complete all as specified and as directed .

11

-

-

... More
S & F in replacement of outdoor fan motor for 2.0 ton AC complete all as specified and as directed .

3

-

-

... More
S & F in replacement of running capacitor of capacity 36 MFD + 5% complete all as specified and as directed .

15

-

-

... More
S & F in replacement of starting capacitor of capacity 60 MFD + 5% complete all as specified and as directed .

15

-

-

... More
S & F in replacement of running Capacitor of capacity 2.5 MFD + 5% complete all as specified and as directed .

15

-

-

... More
Disconnection and removing the unserviceable PCB from the indoor unit of Split type Air conditioner and S & F New PCB suitable for the existing makes of Air conditioners of capacity 1.5/2 TR complete all as specified and as directed .

17

-

-

... More
Disconnection and removing the unserviceable PCB from the indoor unit of invertor type Split type Air conditioner and S & F new PCB suitable for the existing makes of Air conditioners of capacity 1.5/2 TR complete all as specified and as directed .

6

-

-

... More
Disconnection and removing the unserviceable indoor blower motor from the indoor unit of 1.5/2 TR Split type Air conditioner and S & F new indoor blower motor suitable for the existing makes of Air conditioners of capacity 1.5/2 TR complete all as specified and as directed .

10

-

-

... More
Disconnection and removing the unserviceable indoor swing motor from the indoor unit of 1.5 TR Split type Air conditioner and S & F new indoor swing motor suitable for the existing makes of 1.5 TR split type Air conditioners complete all as specified and as directed .

10

-

-

... More
Disconnection and removing the unserviceable indoor swing motor from the indoor unit of 2 TR Split type Air conditioner and S & F new indoor swing motor suitable for the existing makes of 2 TR split type Air conditioners complete all as specified and as directed .

10

-

-

... More
S & F in replacement of copper pipe of size 1/2" dia with necessary fixing arrangements for such as welding, brazing, nut, bolts and testing complete all as specified and as directed .

50

-

-

... More
S & F in replacement of copper pipe of size 1/4" dia with necessary fixing arrangements for such as welding, brazing, nut, bolts and testing complete all as specified and as directed .

50

-

-

... More
S & F in replacement of suitable stand (bracket) for outdoor unit of 1.5/2 ton split air conditioner complete all as specified and as directed .

15

-

-

... More
M & L for gas charging with R134A including comissioning and testing complete of 40/80 Ltrs capacity water cooler complete all as specified and as directed .

3

-

-

... More
S & F in replacement of compressor unit for 40/80 Ltrs capacity of water cooler including comissioning and testing complete all as specified and as directed .

3

-

-

... More
S & F in replacement of thermostat for water cooler of existing capacity complete all as specified and as directed .

3

-

-

... More
S & F in replacement of capacitor of 10 MFD for water cooler complete all as specified and as directed .

3

-

-

... More
Disconnection and removing the unserviceable voltage stabilizer and replace the unserviceable items such as PCB/control board etc and refixing back in its original position testing as per existing makes of capacity 2/4 KVA complete all as specified and as directed Note: Cost for replacement of items will be measured and paid under respective items as Supply only

8

-

-

... More
Supply only PCB/control board suitable for 2.0 KVA Votlage stabilizer

4

-

-

... More
Supply only PCB/control board suitable for 4.0 KVA Votlage stabilizer

4

-

-

... More
S & F in replacement of addressable multi sensor detectors photoelectric optical heat and smoke complete detector include B501 base sleek low profile design, removable cover and insect resistant screen for simple field cleaning but built in tamper resistant feature complete all as specified and as directed .

7

-

-

... More
S & F in replacement of 12 volt 7 AH battery in the fire alarm control panel complete all as specified and as directed .

6

-

-

... More
Taking down old unserviceable LT UG cable from existing position and supply & laying, connecting and commissioning of LT UG cable 50 sqmm 3.5 core 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc. laid in trenches or fixed on walls complete all as specified and as directed .

150

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft/loose soil for laying cables/pipes etc. complete all as specified and as directed .

74

-

-

... More
Returning filling in, with excavated soils including spreading, levelling, watering and well ramming in layers n.exc. 25 cms thick. complete all as specified and as directed .

60

-

-

... More
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed .

14

-

-

... More
M&L for sand cushioning with sand in two layer,first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable including consolidation of each layer complete all as specified and as directed . Note: Punned thickness of sand cusioning shall be measured only for the purpose of payment .

15

-

-

... More
Supply and laying unreinforced precast concrete cable cover class LV 1 flat size of size 250x150x40 mm for cable protection complete all as specified and as directed.

1420

-

-

... More
Cutting the existing hardstanding not less than 25cm in deep and 15cm in width for laying of underground cable / pipe and making good the disturbed surfaces complete all as specified and as directed.

35

-

-

... More
S & F GI tubing 50 mm dia medium grade ISI marked laid in trenches complete with all accessories such as tees union , bend ,elbow nipple reducer etc as required for protection of UG Cable on floor,pole etc complete all as specified and as directed .

10

-

-

... More
S & F in replacement of MCCB 63 Amps ,16 KA, 4 Pole, 415 V 50 Hz including all connections complete all as specified and as directed .

2

-

-

... More
All as per Sl item No. 75.00 here in before but MCCB 100 Amps ,25 KA, 4 pole

2

-

-

... More
All as per Sl item No. 75.00 here in before but MCCB 160 Amps 36 KA, 4 pole

1

-

-

... More
All as per Sl item No. 75.00 here in before but MCCB 250 Amps 36 KA, 4 pole

1

-

-

... More
All as per Sl item No. 75.00 here in before but MCCB 400 Amps 36 KA, 4 pole

1

-

-

... More
Painting of existing LT panels by using two coats of synthetic enamell paint including prepartions of old surfaces complete all as specified and as directed.

3

-

-

... More
Repairs to existing LT panels front and rear doors of locking arrangements by using suitable hinges complete all as specified and as directed.

2

-

-

... More
Supply install and commission of double door type, 415 volts, AC, 50Hz, factory fabricated, dust and vermin proof, made out of non corrosive 3mm thick CRCA sheet bus bar panel of size (900x600x300mm) outdoor type IP-65 protection with 400 amps rated aluminium bus bar mounted on epoxy insulators alongwith suitable sizes of GI nuts, bolts, washers for incoming and outgoing cables and CRCA sheet panel mounted on suitable MS angle iron base frame painted with two coats of synthetic enamel paint over a coat of red oxide primer including PCC foundation and earthing connection arrangements complete all as specified and as directed .

2

-

-

... More
Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead 32x6 mm size, by means nut, bolt, check nuts and washer of galvanized iron and 32x6 mm as earth lead protected by provision of GI light grade pipe 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point including testing complete all as specified and as directed.

4

-

-

... More
Maintenance and servicing of DG Sets (B check) comprising prime mover and alternator with accessories, control panel and connected electric circuits with various type of sensors etc including checking lubricating oil, coolant, filters, V-belt, self starter, battery power, gauges and other connected accessories, cleaning of alternator with vaccum cleaner, attending faults of AMF panels and replacing the defective parts (as per B check i.e. filters, gasket kits, O ring, oil, coolant etc) and identifying malfunction of the DG Set of capacity 30 KVA (Model No. KG1-30WS) complete all as specified and as directed . Note :- (a) Spares of DG Set will be measured and paid seperately under relevent item of the CA catered as supply only. (b) Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the rate quoted. (c) Labour component for fixing the spares during the servicing including testing the DG set is deemed to be included in the quoted rate.

1

-

-

... More
All as per sl item No.84.00 here in before but DG Set of capacity 45 KVA (Model No. ALGPWO417MK1E4)

1

-

-

... More
All as per sl item No.84.00 here in before but DG Set of capacity 62.5 KVA (Model No. AL4CTIDG5)

1

-

-

... More
Dismantling radiator assembly from the engine of 62.5 KVA capacity DG sets by disconnecting inlet and outlet connection overhauling / servicing the radiator, descaling and servicing the radiator internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, re assembling with necessary welding and additional bracket as required including refixing, reconnecting and testing for proper functioning complete all as specified and as directed.

1

-

-

... More
All as per item No 87.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 87.00 here-in-before but for DG Set of capacity 30 KVA

1

-

-

... More
Dismantling of fuel injection pump assembly complete from the engine of DG Set of capacity 30 KVA , servicing, over hauling, replacement of valves, washers etc., assembling, calibration, setting for proper function, reassembling and re-fixing complete all as specified and as directed .

1

-

-

... More
All as per item No 90.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 90.00 here-in-before but for DG Set of capacity 62.5 KVA

1

-

-

... More
Disconnecting and taking down outgoing cables from the DG Set of capacity 30 KVA and cutting removing the burnt cable ends and thimbling and refixing back including provision of cable glands, lugs, tools and testing complete all as specified and as directed .

1

-

-

... More
All as per item No 93.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 93.00 here-in-before but for DG Set of capacity 62.5 KVA

1

-

-

... More
Supply only (in replacement) spin on fuel filter (pre and fine filter) element with O ring for DG Set of capacity 30 KVA

1

-

-

... More
All as per item No 96.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 96.00 here-in-before but for DG Set of capacity 62.5 KVA

1

-

-

... More
Supply only (in replacement) dry type Air filter element Inner and Outer unit as required at site with O' Ring of suitable for DG Set of capacity 30 KVA

1

-

-

... More
All as per item No 99.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 99.00 here-in-before but for DG Set of capacity 62.5 KVA

1

-

-

... More
Supply only (in replacement) Lub oil filter element with O Ring suitable for DG Set of capacity 30 KVA

1

-

-

... More
All as per item No 102.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 102.00 here-in-before but for DG Set of capacity 62.5 KVA

1

-

-

... More
Supply only (in replacement) by pass filter element with O ring of suitable for DG Set of capacity 30 KVA

1

-

-

... More
All as per item No 105.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 105.00 here-in-before but for DG Set of capacity 62.5 KVA

1

-

-

... More
Supply only (in replacement) V-belt suitable for DG Set of capacity 30 KVA

1

-

-

... More
All as per item No 108.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 108.00 here-in-before but for DG Set of capacity 62.5 KVA

1

-

-

... More
Supply only (in replacement) of water pump assy suitable for DG Set of capacity 30 KVA

1

-

-

... More
All as per item No 111.00 here-in-before but for DG Set of capacity 45 KVA

1

-

-

... More
All as per item No 111.00 DG Set of capacity 62.5 KVA

1

-

-

... More
S & F in replacement of common rail diesel sensor suitable for DG Set engine complete all as specified and as directed .

1

-

-

... More
S & F in replacement of water outlet and inlet hose pipe from radiator to Engine and back from Engine to radiator complete all as specified and as directed.

1

-

-

... More
S & F in replacement of Lub oil pipe armoured of suitable length and socket size complete all as specified and as directed.

1

-

-

... More
S & F in replacement of Anti vibration rubber pad for side radiator complete all as specified and as directed.

1

-

-

... More
S & F in replacement of Lub oil pressure guage 0 to 10 kg / sq cm complete all as specified and as directed.

1

-

-

... More
Supply and top up coolent oil complete all as specified and as directed.

50

-

-

... More
Supply and top up engine oil 15W40 grade complete all as specified and as directed.

50

-

-

... More
Supply and replace battery connecting single core copper cable 16sqmm with battery terminal made of brass with nuts/bolts/washer complete all as specified and as directed.

1

-

-

... More
Supply and top up battery distilled water complete all as specified and as directed.

10

-

-

... More
S & F in replacement of SMPS battery charger 12V/24V DC including all fixing accessories and re-wiring with suitable size copper conductor FRLS grade PVC insulated two core cable drawn through PVC conduit not less than 20mm dia as required at site and complete all as specified and asc directed.

1

-

-

... More
Disconnecting, dismantling 12V/24V battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery complete all as specified and directed.

1

-

-

... More
S & F in replacement of AVR (Auto Voltage Regulator) suitable for 30 KVA to 45 KVA capacity Gen Set having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4 A DC voltage regulation +/- 1% average volts, over excitation current tripping fuse protection 4A, fast acting and frequency 50Hz complete all as specified and directed.

1

-

-

... More
All as per item No 125.00 here-in-before but for 62.5 KVA capacity

1

-

-

... More
S & F in replacement of Digital DG controller suitable for any type DG Set of any capacity and connecting with existing electrical circuit complete all as specified and as directed.

1

-

-

... More
S & F in replacement of Diods set (Rectifier) of main alternator of DG Set of capacity 30/45 KVA complete all as specified and as directed.

1

-

-

... More
All as per item No 128.00 here-in-before but for DG Set capacity 62.5 KVA

1

-

-

... More
S & F in replacement of contactor 4 pole, 65A, coil volt-240volts, AC 50Hz com plete all as specified and as directed

1

-

-

... More
S & F in replacement of contactor 4 pole, 100A, coil volt-240volts, AC 50Hz com plete all as specified and as directed

1

-

-

... More
S & F in replacement of CT coil with CT Ratio 100/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992 complete all as specified and as directed.

1

-

-

... More
S & F in replacement of fuse unit 12 V DC (as per sample) suitable for DG Set control pane complete all as specified and as directed.

1

-

-

... More
Minor repair / cleaning of fuel tank, removing sludge, arresting leak using metal paste / sealent or by welding / soldering, replacement of diesel receiver pipe from lock to tank with clamp set all as required at site for DG Set of capacity 30/45 KVA complete all as specified and as directed.

1

-

-

... More
All as per item No 134.00 here-in-before but for DG Set capacity 62.5 KVA

1

-

-

... More
Minor repair to canopy such as to hinges, locking arrangement etc and painting inside /outside area of DG Set 62.5 KVA comprising engine, alternator, genset panel board and fuel tank and canopy, as per standard approved colour code with one coat of synthetic enamel paint cleaning scrubbing of all surface including writing by paint the SM/MES numbers etc complete all as specified and as directed.

1

-

-

... More
All as per item No 136.00 here-in-before but for 30/45 KVA Genset

1

-

-

... More
Dismantling, removing the self starter, motor from the engine of DG Set of capacity 30 / 45 KVA , opening the self starter body and overhauling / servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and as directed.

1

-

-

... More
All as per item No 138.00 here-in-before but for DG Set of capacity 62.5 KVA

1

-

-

... More
S&F asbestos rope 12 mm dia wrapped over the exhaust pipe and painting with heat proof paint of approved colour including taking down the old rope complete all as specified and as directed.

5

-

-

... More
S & F in replacement of volt meter digital type with 01 x selector switch complete all as specified and as directed.

1

-

-

... More
S & F in replacement of ampere meter digital type with 01 x selector switches & CTs of suitable rating complete all as specified and as directed.

1

-

-

... More
S & F in replacement of LED phase indicator lamp assy RYB complete all as specified and as directed.

1

-

-

... More
S & F in replacement of water separator suitable for DG sets of capacity 62.5 KVA complete all as specified and as directed.

1

-

-

... More
All as per item No 144.00 here-in-before but DG Set of capacity 30 KVA to 45 KVA complete all as specified and as directed.

1

-

-

... More
S&F DG Set diesel tank lock (as per sample) with fixing accessories complete all as specified and directed.

1

-

-

... More
Checking of AMF panels including replacement of unserviceable parts such as relays, timers, power contactors, Auxilary contactors, defective copper wiring, MCCBs etc. for DG Set, complete all as specified and directed. Note: - Spare parts shall be measured and paid separately under Supply only items

1

-

-

... More
Supply only ON and OFF delay timer 240 V AC

1

-

-

... More
Supply only Earth fault relay.

1

-

-

... More
Supply only Over load relay.

1

-

-

... More
Supply only Under voltage relay.

1

-

-

... More
Supply only Power Contactor MCX11, 4 Pole

1

-

-

... More
Dismantling of 62.5 KVA capacity alternator from Generator after Dismantling from Generator shifting to workshop, taking out burnt out winding from stator & rotator, cleaning thoroughly and rewinding the stator with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating, reassembling of alternator, bringing back to the site, refixing and installation and foundation with proper alignment, testing and commissiong complete all as specified and as directed. Note :- Transportation from the site to workshop and back and labour element is deemed to included in rate quoted.

1

-

-

... More
All as per item No.153.00 here-in-before but of capacity 30/45KVA

1

-

-

... More
S & F in replacement of aluminium strip of size 25 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors including all connections complete all as specified and as directed.

15

-

-

... More
S & F in replacement of Air termination, single pointed, aluminium rod 12mm dia and 300mm long including all connection complete all as specified and as directed.

4

-

-

... More
S & F in replacement of ceramic insulators of height not less than 50 mm clearance fixed to floor/wall/ ceiling and provision for fixing lightening conductor including necessary fixing arrangements such as nut, bolts or welding etc. including all connections complete all as specified and as directed.

25

-

-

... More
Taking down old unserviceable LT UG cable from existing position and supply & laying, connecting and commissioning of LT UG cable 10 sqmm 4 core 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc. laid in trenches or fixed on walls complete all as specified and as directed.

120

-

-

... More
S & F GI tubing 40 mm dia medium grade ISI marked laid in trenches complete with all accessories such as tees union , bend ,elbow nipple reducer etc as required for protection of UG Cable on floor,pole etc complete all as specified and as directed .

10

-

-

... More
S & F in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.

8

-

-

... More
S & F in replacement of street light brackets made out of 40mm bore GI tubing, light grade, 1.5m long, bent to required shape, including necessary bending, welding, etc fixed with 2Nos. clamps made out of 32x5mm GI strip including necessary drilling holes, screws, nuts, bolts, etc complete all as specified and as directed

8

-

-

... More
S & F in replacement of LED bollard lighting of 10 W energy saving and environmental friendly long life aesthetically designed aluminium landscape IP 65 luminare for diffused lighting with high power LED as light source including all connections complete all as specified and as directed.

8

-

-

... More
Dismantling the centrifugal / submesible pump set of capacity 1 HP and transportation to workshop for replacing unserviceable parts such as impeller,shaft, bearing, winding etc and reconnecting back the pumpset to its original position after repair and testing complete all as specified and as directed.

2

-

-

... More
All as per item No.163.00 here-in-before but of capacity 1. 5 HP

5

-

-

... More
All as per item No. 163 here-in-before but of capacity 2.0 HP

2

-

-

... More
Disconection and removing the defective DOL starter and S & F the new DOL starter three phase 440 Volts , 50 Hz suitable for motor capacity up to 5 HP testing complete all as specified and as directed.

2

-

-

... More
Disconection and removing the defective DOL starter and S & F the new DOL starter single phase 240 Volts , 50 Hz suitable for motor capacity up to 1.5 HP testing complete all as specified and as directed.

3

-

-

... More
S & F in replacement of PVC foot valve of 50 mm bore complete all as specified and as directed.

2

-

-

... More
All as per item No. 168.00 here-in-before but of 40 mm bore.

2

-

-

... More
All as per item No. 168.00 here-in-before but of 32 mm bore.

2

-

-

... More
S&F in replacement of CPVC ball valve of 25 mm bore complete all as specified and as directed.

3

-

-

... More
All as per item No. 171.00 here-in-before but of 32 mm bore.

3

-

-

... More
All as per item No. 171.00 here-in-before but of 40 mm bore.

3

-

-

... More
All as per item No. 171.00 here-in-before but of 50 mm bore.

3

-

-

... More
Supply & laying in replacement of CPVC pipes of 25mm bore SDR 13.5 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete all as specified and as directed .

30

-

-

... More
All as per item No. 175.00 here-in-before but of 32 mm bore.

30

-

-

... More
All as per item No. 175.00 here-in-before but of 40 mm bore.

46

-

-

... More
All as per item No. 175.00 here-in-before but of 50 mm bore

47

-

-

... More
S&F in replacement of CPVC brass elbow of 25 mm bore complete all as specified and as directed.

3

-

-

... More
All as per item No. 179.00 here-in-before but of 32 mm bore

3

-

-

... More
All as per item No. 179.00 here-in-before but of 40 mm bore

3

-

-

... More
All as per item No. 179.00 here-in-before but of 50 mm bore

3

-

-

... More
S&F in replacement of CPVC brass tee of 25 mm bore complete all as specified and as directed

3

-

-

... More
All as per item No. 183.00 here-in-before but of 32 mm bore

3

-

-

... More
All as per item No. 183.00 here-in-before but of 40mm bore

3

-

-

... More
All as per item No. 183.00 here-in-before but of 50mm bore

3

-

-

... More
S&F in replacement of CPVC male brass threaded adaptor of 25 mm bore complete all as specified and as directed

2

-

-

... More
All as per item No. 187.00 here-in-before but of 32 mm bore

2

-

-

... More
All as per item No. 187.00 here-in-before but of 40mm bore

2

-

-

... More
All as per item No. 187.00 here-in-before but of 50mm bore

2

-

-

... More
S&F in replacement of CPVC female brass threaded adaptor of 25 mm bore complete all as specified and as directed

2

-

-

... More
All as per item No. 191.00 here-in-before but of 32 mm bore

2

-

-

... More
All as per item No. 191.00 here-in-before but of 40mm bore

2

-

-

... More
All as per item No. 191.00 here-in-before but of 50mm bore

2

-

-

... More
S&F in replacement of CPVC union of 25 mm bore complete all as specified and as directed

3

-

-

... More
All as per item No. 195.00 here-in-before but of 32 mm bore

3

-

-

... More
All as per item No. 195.00 here-in-before but of 40mm bore

3

-

-

... More
All as per item No. 195.00 here-in-before but of 50mm bore

3

-

-

... More
Construction of 200mm thick PCC solid block wall masonary valve chamber built in CM 1:6 with 150mm thick PCC foundation 1:2:4 type B-1 coping 50mm thick finished even and smooth, rendering 10mm thick in cement mortar (1:6), finished fair and and even externally including excavation earthwork in any strata, 6mm thick MS sheet cover fixed on angle iron frame 25x4mm embedded in PCC coping with locking arrangement and mild steel hold fast, mild steel handles and painting to steel surface with two coats of black bituminus paint over one coat of red oxide primer etc, for internal size 600x600x600mm including the demolishing PCC chamber complete all as specified and as directed .

6

-

-

... More
Comprehenssive maintenace and complete servicing and periodic maintenance (ie once in three months / each quarter) of RO plant of capacity 500 LPH by replacing of filters and other components complete to ensure the quality of RO water and proper operation of RO plant complete all as specified and directed Note :- Any minor spares required during the servicing is also deemed to be included in the rate quoted .

9

-

-

... More
Cmplete servicing of high pessure pump / motor of RO plant by dismantling entire pump assembly, cleaning, servicing and replacement of damaged parts if any such as impeller/washer/bolt/ connected parts in the pump and servicing of motor by dismantling, cleaning & varnishing of coil, rewinding , replacement of carbon brush and other parts, reassembling of the same, including testing and operation of pump to suit above RO plant for designed water output including its transportation complete all as specified and as directed .

3

-

-

... More
Supply only NSF certified food grade RO membrane cleaner acid

150

-

-

... More
Supply only NSF certified food grade PH booster

150

-

-

... More
Supply only NSF certified food grade miniral booster

147

-

-

... More
Supply only NSF certified food grade chemical anti scalent for RO dosing system

150

-

-

... More
S & F in replacement of 5 micron catridge filter suitable for existing make complete all as specified and as directed

18

-

-

... More
S & F in replacement of RO membrane 4040 as per manufacturers specification for 500 lph membrane with salt rejection 96-99% suitable for existing system and testing complete suitable for RO plant of capacity 500 LPH with input raw water having TDS more than 6000 PPM complete all as specified and as directed .

16

-

-

... More
S & F in replacement of manual multiport valve top / side mounted filter / softener suitable to fix in CPVC pipe line 40mm dia , inlet / outlet to vessel top & bottom 11/2 inch BSPF, max operating pressure - 5Kg/Cm2, max flow service / rinse / backwash - 6m3/hr@0.5 Kg/cm2 pressure drop complete all as specified and as directed .

6

-

-

... More
S & F in replacement of pressure gauge [0-20 kg/cm2 or 0-300 PSI] or [0-300 PSI] suitable for existing system complete all as specified and as directed .

6

-

-

... More
S & F in replacement of rotometer / flowmeter gauge for indicating prodct flow or R\rejection flow suitable for existing system complete all as specified and as directed.

5

-

-

... More
S&F in replacement of dosing pump with connecting pipes and FRP tank complete all as specified and as directed by Engr-in-charge.

3

-

-

... More
S&F in replacement of 5 micron filter catridge housing complete all as specified and as directed .

5

-

-

... More
S&F in replacement of LPS switch range 0.5 to 5 kg/cm2, differential 0.5 with connecting pipe, metal connectors and wires complete all as specified and as directed .

3

-

-

... More
S&F in replacement of HPS switch range 2 to 25 kg/cm2, differential 0.5 with connecting pipe, metal connectors and wires complete all as specified and as directed .

3

-

-

... More
S&F in replacement of UV sterlizer suitable for existing system and testing complete all as specified and as directed .

3

-

-

... More
Complete replacement of rapid sand filter media of RO plant including replacement of filter media, rubber gaskets, nut bolts, filters and other parts as required complete all as specified and as directed .

3

-

-

... More
Complete replacement of activated carbon filter media of RO plant including replacement of carbon filter media, rubber gaskets, nut bolts, filters and other parts as required complete all as specified and as directed .

3

-

-

... More
S&F in replacement of RO membrane FRP pressure vessel housing 4080, operating Pressure - 300 psi with end cap O ring, rubber gasket and italian coupling suitable for existing system complete all as specified and as directed .

3

-

-

... More
S&F in replacement of control panel suitable for RO plant of capacity 500 LPH complete all as specified and as directed .

3

-

-

... More
S&F in replacement of raw water / treated water pump capacitor of 45 mfd complete all as specified and as directed .

5

-

-

... More
S&F in replacement of ball valve suitable to fix in CPVC pipe of dia 25mm complete all as specified and as directed .

12

-

-

... More
S&F in replacement of ball valve suitable to fix in CPVC pipe of dia 40mm complete all as specified and as directed .

12

-

-

... More
S&F in replacement of star delta motor starter suitable for raw water pump, 3 phase, 415V, 50 Hz complete with sheet metal enclosure to be fixed in the existing panel complete all as specified and as directed .

3

-

-

... More
Repairs to centrigugal pumpset of capacity up to 2 HP such as rewinding , water seal,impeller,shaft,bearing etc.complete all as specified and as directed .

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.