Military Engineer Services Tender

... More
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date6 Mar 2025
Closing Soon5 Apr 2025
Tender Amount₹ 27,00,000 
Notes
Download

Costs

Summary

Token No. Ge/k-90/2024-25 - Repair And Maint Of External Water Supply

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Cleaning of RCC Semi underground reservoir / tank to be cleaned from silt and scrapping the internal surfaces of the tank with wire brush, removing the fungus deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the reservoir/UG sump with bleaching powder solution including applying two coats of lime wash on internal surface of wall, ceiling, floor complete and writing “TANK CLEANED ON ………..” on external surface with white paint on black base including preparation of surface & applying two coats of cement based paint on the external surface. The letter height should not be less than 4" for 50000 litres capacity complete all as specified and directed by EIC.

1

-

-

... More
M&L for Cleaning of RCC Semi underground reservoir / tank to be cleaned from silt and scrapping the internal surfaces of the tank with wire brush, removing the fungus deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the reservoir/UG sump with bleaching powder solution including applying two coats of lime wash on internal surface of wall including ceiling, floor complete and writing “TANK CLEANED ON ………..” on external surface with white paint on black base including preparation of surface & applying two coats of cement based paint on the external surface. The letter height should not be less than 4" for 16500 litres capacity complete all as specified and directed by EIC.

2

-

-

... More
M&L for Cleaning of RCC Semi underground reservoir / tank to be cleaned from silt and scrapping the internal surfaces of the tank with wire brush, removing the fungus deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the reservoir/UG sump with bleaching powder solution including applying two coats of lime wash on internal surface of wall including ceiling, floor complete and writing “TANK CLEANED ON ………..” on external surface with white paint on black base including preparation of surface & applying two coats of cement based paint on the external surface. The letter height should not be less than 4" for 34500 litres capacity complete all as specified and directed by EIC.

1

-

-

... More
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in hard/ dense soil complete all as specified.

199

-

-

... More
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick, all as directed.

196.5

-

-

... More
Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, all as directed.

2.5

-

-

... More
Taking up or down old unserviceable GI/MS/PPR tubing and connetions of following sizes including all fittings from the trenches, wall, floor etc complete as directed.

-

-

-

... More
15 mm bore size

480

-

-

... More
20 mm bore size

510

-

-

... More
25 mm bore size / 32 mm bore size

500

-

-

... More
40 mm bore size

360

-

-

... More
50 mm bore size

360

-

-

... More
80 mm bore size

204

-

-

... More
100 mm bore size

30

-

-

... More
150 mm bore size

18

-

-

... More
Relaying/refixing after repairing/Cleaning thoroughly complete to the GI/MS pipes in old or new position obtained from above item No. 10 including new fittings complete of following sizes in trenches :-

-

-

-

... More
15 mm bore size

300

-

-

... More
20 mm bore size

240

-

-

... More
25 mm bore size

210

-

-

... More
40 mm bore size

240

-

-

... More
50 mm bore size

240

-

-

... More
80 mm bore size

120

-

-

... More
100 mm bore size

30

-

-

... More
Material and labour for laying of GI tubing medium grade of ISI marked complete with all necessary fittings of the follwing sizes in trenches/floors/wall

-

-

-

... More
15 mm bore size

180

-

-

... More
20 mm bore size

180

-

-

... More
25 mm bore size

120

-

-

... More
40 mm bore size

120

-

-

... More
50 mm bore size

120

-

-

... More
80 mm bore size

84

-

-

... More
Material and labour for laying of GI tubing medium grade of ISI marked of size 150 mm complete with flanged joints and other fittings in trenches/floors/wall complete all as directed .

24

-

-

... More
S & F in repair cast iron sluice valve, class PN 1.6, conforming to IS-14846, ISI marked with brass spindle complete with flanged ends including necessary nuts, bolts, washers and rubber gaskets, 3mm thick, heavy duty and iron wheel complete with jointing material including taking out old unserviceable sluice valve of following sizes :-

-

-

-

6

-

-

... More
100 mm

6

-

-

... More
S & F Ball valve 15 mm bore with polythene float and flynut complete, screwed for iron pipes and fixed complete including taking down of old one.

43

-

-

... More
S & F Ball valve 20 mm bore with polythene float and flynut complete, screwed for iron pipes and fixed complete including taking down of old one.

20

-

-

... More
S & F Ball valve 25 mm bore with polythene float and flynut complete, screwed for iron pipes and fixed complete including taking down of old one.

20

-

-

... More
S&F Gun metal gate valve 40 mm bore with iron hand wheel head , screwed both ends for iron pipes and fixed complete including taking down of old one.

20

-

-

... More
S&F Gun metal gate valve 50 mm bore with iron hand wheel head , screwed both ends for iron pipes and fixed complete including taking down of old one.

20

-

-

... More
Material and labour for PCC (1:2:4) type B2 using 20mm graded crushed stone aggregate as in foundation, filling and mass concrete including necessary form work, including cutting of roads complete all as directed.

2.5

-

-

... More
Supply & laying 3-layer PP-R Polypropylene random copolymer pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc including all necessary fittings such as T, Bend, Joints, Nipple etc of following sizes complete all as specified and directed.

-

-

-

... More
20 mm bore size (outer dia of pipe in mm)

90

-

-

... More
25 mm bore size (outer dia of pipe in mm)

90

-

-

... More
32 mm bore size (outer dia of pipe in mm)

80

-

-

... More
S&F in repair foot valve /strainer of size 80mm bore for suction pipe flanged ISI marked complete with nuts, bolts and washers packing material etc. complete all as specified & directed.

2

-

-

... More
Taking out submersible pump of any capacity from bore well and lowering into bore well after repairing/rectification of defects in submersible motor pump (Note-Repairing of pump and motor will be measured and paid separately).

2

-

-

... More
Repair to submersible motor assembly of capacity 25 HP by dismantling unserviceable motor by cutting, wornt out copper winding as per specification,coupling etc and replacing with new copper winding and necessary parts with necessary connections and testing then Reassembling with the pump and motor including scrubbing and painting to motor complete as directed as specified by Engr-in-Charge.

2

-

-

... More
Repair to submersible pump of capacity 25 HP by dismantling unserviceable pump by replacing, wornt out impeller sets and replacing with new impeller sets, motor pump coupling etc complete as directed as specifed by Engr-in-Charge.

2

-

-

... More
Repair and maintenance of centrifugal electric driven self priming pump set of capacity 40 HP by disconnecting the electric connection,removing from site and dismantling it and replacing the worn out motor shaft,bearing, worn out winding and replacing with as per existing specification, repair to centrifugal pump by replacing the worn out impeller, shaft, gland, nuts and bolts and refixing at same position all as specified and as directed by Engr-in-Charge.

2

-

-

... More
S&F in repair of Three Phase automatic star delta starter suitable for centrifugal pump/ submersibile pump set of capacity 12.5 HP, over load relay and shortcircuit protection complete all as specified and directed by the Engr In charge.

2

-

-

... More
S&F in repair of MS column pipe up to 50mm dia heavy duty medium grade' with MS flanged and drilled at both ends duly threaded and welded of 3 mtr long alongwith cut for passing the submersible cable including bolts, nuts, washers and rubber insertions packing complete all as specified and directed by Engineer-in-Charge.

28

-

-

... More
S&F in repair of PVC insulated and sheathed submersible cable flat three core copper conductor cable size 10.00 sqmm 1100 volts grade conforming to IS-694/1990.

300

-

-

... More
S&F in repair of PVC insulated and sheathed submersible cable flat three core copper conductor cable size 6.00 sqmm 1100 volts grade conforming to IS-694/1990.

300

-

-

... More
S & F in repair of unserviceable lead acid maintenance free battery 12 Volts 180 AH battery complete all as specified and as directed by Engr-in-Charge.

3

-

-

... More
S & F in repair of Battery Terminal for 12 Volts 180 AH battery complete all as specified and as directed by Engr-in-Charge

6

-

-

... More
S & F in repair of Battery Cable of size 16Sqmm Single Core made of stranded copper conductor for 12 Volts 180 AH battery complete all as specified and as directed by Engr-in-Charge

32

-

-

... More
M&L for repair of leakage of water supply line including necessary excavation up to 1.5 m depth in hard /dense soil with returning filling and removal of excavated soil and testing of pipeline after reparing complete all as specified and directed by engr-in charge. Note - Any connected items required for repair of pipe line such as Bend, socket, Aluminium sheet, insulation and anti freezing cable etc are included in quoted rate).

6

-

-

... More
M&L for 40mm thick closed cell elastomeric insulation min 42 Kg/m3 density glass wool fiber insulation with aluminium sheet cover over any size of GI/PPR pipes on exposed portion including taking out of old insulation complete all as specified and directed by Engr-in-Charge.

345

-

-

... More
M&L for providing tracer/ antifreezing cable (self regulating heating cable) 220Volt, min 25 watt/M required to keep the pipe warm avoiding freezing water all as specified including electrical wiring cable for connection of suitable size including taking down of burnt tracer cable Complete all as specified and directed by Engr-in-Charge.

360

-

-

... More
Supply and fixing in repair of booster pump set of cap 0.5 HP, 230 volts, 1 phase, 50 Hz complete all as specified and directed by Engr-in-Charge. Make -Crompton (model No- MINI-FORCE II) or Equivalent

10

-

-

... More
Construction of valve pit chamber of size 90cmx90cmx90cm (Internal dimension) of double brick masonary with internal plastering from the top of surface including cover of MS sheet 3.15mm thick and angle iron 40mmx40mmx6mm with hinges and locking arrangement including painting with two coat of synthetic enameled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement mortar 1:3, foundation concrete 1:3:6 including necessary earthwork including demolition of old valve pit chamber complete all as specified and directed.

4

-

-

... More
Repair to non clogging centrifugal electric driven self priming pump set of capacity 7.5 HP by disconnecting the electric connection, removing from site and dismantling it and replacing burnt out winding with same guage of winding wire and repair to pump by replacing the worn out shaft,gland nut bolts, impleller etc. and refixing at the same position complete all as directed.

3

-

-

... More
Note : Deduction for amount of Rs. 75,295.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.