Military Engineer Services Tender
... More
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_644311_1Bid Award Id
ViewTender No
8001/GE/KHU-78Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Driver for 40/45 Watts LED
40
-
-
... More
Driver for 25/30 Watts LED
50
-
-
... More
Excavation in trenches not exceeding 1.5m in depth deep for laying of pipe, cable, foundation of electric pole etc and getting out in hard soil, complete all as specified and directed by Engr-in-Charge.
135
-
-
... More
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr-in-Charge. (Surplus soil if any shall not be removed but left over the trench)
90
-
-
... More
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
45
-
-
... More
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified and directed by Engr-in-Charge.
Note :- For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I.
40.5
-
-
... More
M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other at site complete all as specified and directed by Engr-in-Charge.
3125
-
-
... More
Supply and fixing in repair Junction box made out of FRP sheet of make approved by GE, ready made type having aluminium bus bar of capacity 100 Amps 4 Nos including bakelite connector of size 300x200x115 with necessary connector , MCB 6 Amps and entry of gland and fixing arrangement to fix the box on plinth/wall by providing MS clamp and nut bolt as per product Complete all as specified and directed by Engineer-in-Charge.
80
-
-
... More
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 30 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion IP-66 with mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 45 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc. complete all as specified and directed by Engr-in-Charge.
30
-
-
... More
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 60 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 30 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed by Engr-in-Charge.
80
-
-
... More
Supply, fixing, connecting and testing in replacement integral LED flood light luminaries, 45 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
Supply and fixing in repair PVC insulated and PVC sheathed three core Copper conductor of size 1.5 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting complete all as specified and directed by Engr-in-Charge.
300
-
-
... More
Supply and fixing in replacment GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required for fixing of street lights on poles/walls including nuts, bolts, washers , Clamps (02 sets) of suitable size complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
Supply and fixing in replacement of Automatic Street Light Switch for 3-phase Load of 08 KW using Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS) for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 30 Lux and for Switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. The Sensor along with suitable Power Contactors with 3 nos. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 20-32 Amps each. Circuit wiring (Copper) of min.10 sq.mm and Auto-Manual selection option (Sensor By-Pass) should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP-66 complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 16 Sq mm 4 core complete all as specified and directed by Engr-in-Charge.
500
-
-
... More
Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 10 Sq mm 4 core complete all as specified and directed by Engr-in-Charge.
500
-
-
... More
M & L for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor,along the pole including taking down complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0 mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Deduct Credit for Demolished/Dismantled material Rs (-) 47965.00 (Minus) as listed in Schedule 'A' Sec-II (Credit Schedule)
Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements