Military Engineer Services Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 95,040Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686054_1Tender No
82132/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wall: Internal wall :- The walls panel shall be of min 140 mm thick continuous line manufactured Sandwich wall Panels with facility of customized Length. Insulation core: modified Rock wool insulation Core with an internal temperature range of -25°C to +100°C. The Panels shall be rock wool insulated of density not less than 48 Kg/Cubic meter sandwiched between 12.5 mm thick Gypsum board adn min 8 mm thick fiber cement board on both sides. it should also cater for fixing of tiles.
-
-
-
External wall :- The walls panel of min 140 mm thick continuous line manufactured Sandwich wall Panels with facility of customized Length. Insulation core: foam insulation Core with an internal temperature range of -25°C to +100°C. The External cladding to be PPGI sheet of approved colour of min thickness 0.5 mm. internal surface to be of 12.5 mm thick Gypsum board cover fiber cement board minimum 8 mm thick. Rock wool insulated of minimum thickness of 50 mm density not less than 48 Kg/Cubic meter tone sandwiched between the external and internal board. All necessary flashings will be provided at corners and joints. Camouflage painting as required colour and pattern of CGI sheet will be approved by GE. Certification from NABL accredited Lab to be submitted along with bid.
-
-
-
The wall panels shall be cover width shall be minimum 1100mm or as per design with tongue and groove joint interlocking system. Panels to be laid with factory applied weather seal at side laps to provide complete weather tight performance. All materials required for the manufacture of shelter shall be new and shall comply with relevant Bureau of Indian Standard specification.
-
-
-
GI Metal Skin for Panels for external surface only: 0.50mm thick hot dipped galvanized steel sheets on inner and outer side with 25 micron thick PVC guard film on the finished surface only for protection against scratches during handling and transportation. Base metal of GA skin IS-513 as per GR-120, IS-277. The pre coated GI sheet should have minimum coating of 4-5 micron epoxy primer and 25 micron polyester top coat on the finished surface. The pre coated GI sheet should conform to IS-14246-1995 with manufacturer test certificates conforming above specification
-
-
-
False ceiling panel: The false ceiling will be made up of 60mm thick continuous line manufactured hybrid core insulated fireproof sandwich ceiling Panels in min 1100mm width with facility of customized Length, Core Type modified insulation Core with an internal temperature range of -25°C to +100°C. The Panels will be made of 0.50mm thick color coated steel sheets on both side with 50 mm thick layer of rock wool providing max U value of 0.36 w/m2k with all necessary certification to be submitted along with bid. The False ceiling panels will be provided with tongue and groove joint interlocking system. All materials required for the manufacture of shelter shall be new and shall comply with relevant Bureau of Indian Standard specification. The false ceiling panels will be provided with tongue and groove or lip locking joint for interlocking. False ceiling will be supported with the help of inverted CRCA Tee Section 50 x 50 x 6 mm thick (4.40 Kg/Rm) and L- section of 50 x 50 x 5mm thick (3.80 Kg/Rm) fixed appropriately to the Truss.
-
-
-
Flashing. Suitable flashing with 0.6mm thick pre-coated sheet of matching color with panels will be provided at all joints between roof and wall corners.
-
-
-
Roof: 0.50 mm thick PPGI sheet approved color fixed with self-tapping screws over steel purlins. Steel sheets shall be laid with corrugations over lap at sides and 15 cm end overlap or as per manufacture's instruction. Pre painted (matching with roof tint) wind tie of size 40 X 5mm flat iron shall be provided at lower and upper horizontal end of each pitch for protection against wind. The Profile of PPGI sheet of approved colour on roof will project 400mm outside the ends of front and rear side and 300mm at the both gable ends. In addition to self-tapping screws shall also be fixed for roof sheeting. The sheets shall be conforming as per relevant IS
-
-
-
Ridge Cover 0.50 shall be of mm thick pre-coated corrugated/plain sheet of approved color matching with the roof sheet of size & design, 3.0 m long and 900 mm wide shall be provided. PPGI sheet is to be fixed on top junction of the roof using suitable self-tapping screws over steel purlins. Installing foam closers between Ridge cover and Roof sheet to avoid the entry of snow inside the shelter. No gap should be there in the roof design for allowing the entrance of snow inside the roof from ridge and roof sheet. MAKE: TATA/ SAIL/JSW
-
-
-
Wind Breaker Roof :- The wind breaker cabin roof shall be made up of 50mm thick + minimum 28 mm trapezoidal shape Panels. The Panels will be made of 0.6 mm thick PPGI on both sides and a layer of rigid CFC free polyurethane foam of density 44 kg +/-2kg/ cum as Insulation. The roof PUF panels have one ridge / end lap overlapping of minimum 150 mm on the sides and will be fixed on to the roof steel structure using STSD screws.
-
-
-
Deck slab:- Deck slab shall be of adequate thickness which shall be fixed to the beam and web of frame with RCC laid on the top as per arch drawings including all structural members to take up the deck slab load as per design.
-
-
-
Flooring:- (a) Cook House, Store Room, Washing Area, Meat Cutting Room:- 20-22 mm thick machine cut pre polished Kota Stone Homogenous colour flooring set with neat cement slurry mixed with colour over 20mm thick screed bed in CM 1:4 over sub base (75mm PCC 1:4:8/ floor slab) The minimum size of KOTA Stone in flooring will be 550X550mm or 550X400 mm complete all as specified and directed. (b) Dinning Hall and Living Room: Ceramic Tile of size 400x400 and 7-8 mm thick and in the dining area Vitrified Tiles of size 600x600 of 9-10 mm thick over 15 mm thick screed bed in CM 1:6 over sub base of 75 mm thick PCC 1:4:8 complete all as specified and directed please.
-
-
-
03 Nos Ventilator :- 03 Nos-Powder coated aluminum ventilator of size 600x750 mm fixed type including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screw etc and glazing with heat insulated sheet glass of min 6 mm thick compete all as specified. Outer frame shall be made of 1.6mm thick weight not less than 0.710 kg/mAll the material used for aluminum frame work should conform to IS-733- 1983, IS-737-1986 or IS-1285- 2002 Make: Tata/Jindal/Hidalco as shown in drg
-
-
-
06 Nos-Powder coated aluminum three track sliding window of size 1200 x 1200 mm with glazing of heat insulated sheet glass of min 6 mm thick glass and stainless steel fly proof mesh with aluminum grill shall be provided (02 no’s of glass shutter, 01 Nos wire mesh shutter). Outer frame shall be made of 1.6mm thick weight not less than 0.710 kg/m and shutter frame shall be made of size 44 x 44 x 1.6mm thick weight not less than 0.670 kg/m and clip shall be made of size 21 x 15.4 x 1.22mm weight not less than 0.18 kg/m. Mullion shall be made of size 59 x 38 x 1.6mm thick weight not less than 0.85 Kg/M. Grill frame shall be made of 42.4 x 10 x 12mm thick weight not less than 0.325 Kg/m and including 5mm thick glass necessary joining cleats, glazing chips, rubber packing. Aluminum grill having 10mm dia weight not less than 0.54 Kg/Sqm along to with aluminum fly proof mesh having 1mm aperture of wire mesh 24 gauges shall be fixed aluminum shutter. All the material used for aluminum frame work should conform to IS-733- 1983, IS-737-1986 or IS-1285- 2002 Make: Tata/Jindal/Hidalco as shown in drg
-
-
-
Main Doors. 01 Nos of Powder coated (min thickness of powder coating 50 micron) Aluminium door shutter of size 1200mm x 2100 mm aluminium section weight not less than 0.60 kg/m including necessary jointing cleats glazing clips, rubber neoprene packing, aluminium snap beading screws etc glazing with heat insulated sheet glass of min 6 mm thick on both panel and including powder coated aluminum frame of min thickness of 2 mm fixed to the structure complete all as specified and shown on arch drawing. The powder coated aluminium door shutter including providing and fixing hinges/pivots, 01 No 4 lever brass Mortice lock vertical type, 01 Nos of aluminum AL drop of 250 mm and Aluminum tower bolts of 200 mm size from inside and 2 Nos D type aluminium handles and 01 No aluminium hydraulic door closer should be provided in each shutter. All the material used for aluminum frame work should conform to IS-733-1983, IS-737-1986 or IS- 1285-2002. as shown in diag
-
-
-
Internal Doors: 06 Nos of Powder coated (min thickness of powder coating 50 micron) Aluminium door shutter of size 900mm x 2100 mm aluminium section weight not less than 0.60 kg/m including necessary jointing cleats glazing clips, rubber neoprene packing, aluminium snap beading screws etc glazing with heat insulated sheet glass of min 6 mm thick on top panel and 06 mm thick pre-laminated particle board on bottom panel and including powder coated aluminum frame fixed to the structure complete all as specified and shown on arch drawing. The powder coated aluminium door shutter including providing and fixing hinges/pivots, 01 Nos of aluminum AL drop of 250 mm and Aluminum tower bolts of 200 mm size from inside and 2 Nos D type aluminium handles. All the material used for aluminum frame work should conform to IS-733-1983, IS-737-1986 or IS- 1285-2002. as shown in diag
-
-
-
Serving slab (SS), Washing slab (WS), Bhatti platform (BP), Veg Cutting slab (CS), Shelf (as per drg). All slabs, platforms and shelves to be constructed with PCC of ratio 1:2:4, rendering with cement mortar 1:6 and finishing with distemper. Serving slab and veg cutting slab to be provided with Granite (of any type) tiles 25mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete with granite/marble on top. Washing slab, Bhatti platform and all shelves to be provided with Machine cut kota stone slab 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and as directed by Engr-in-charge. Location as per drg.
-
-
-
S/F of PUF insulated water storage tank min 3 layer of capacity 1000L including ball valve high pressure, gate valve for inlet and outlet water pipe with proper plumbing and staging for shelter complete all as specified and directed.
-
-
-
01 Manhole of internal size 300x300 mm is to be provide for connection of sewage/drainage pipe to existing nearby soakage well/septic tank complete all as specified and directed please.
-
-
-
Note:- Anything missed out above but required as per arch line plan for construction of building so as to meet its functional requirement shall be deemed to be included in quoted rate.
-
-
-
SANITARY FITTINGS & INTERNAL WATER SUPPLY
-
-
-
S&F 3 Layer PPR concealed pipes of dia 120mm SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain and brass threaded PPR random fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and directed
35
-
-
S&F wash basin, vitreous china (flat back or angle back type) size 630x450 with waste coupling including cutting for and pinning in end of brackets or erecting stand including supply and fixing waste pipes 32/40 mm dia of suitable length complete all as specified and directed.
3
-
-
S&F PVC connection pipe of 15 mm size with PTMT nuts of length 300 mm complete all as specified and directed
3
-
-
S&F SS soap dish, any type, size 160x160 mm fixed to plugs with chromium plated brass screws complete all as specified and directed
5
-
-
S&F 600x450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board of commercial plywood and fixed to wooden plugs with chromium platted brass screws and cup washers complete all as specified and directed.
1
-
-
S&F for 15mm pillar taps, cast copper alloy, with capstan heads ,chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed
1
-
-
S&F PVC (SWR) 75mm floor trap ,plain with grating (hole type) including jointing with solvent cement complete all as specified and directed
5
-
-
S&F sink made of stainless steel 1mm thick for kitchen with plugs, washers and waste; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495x420mm bowl size 410mmx330 mm x160mm complete all as specified and directed.
2
-
-
S&F Bib tap 15mm cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
3
-
-
S&F 15mm stop valve fancy type, chromium plated screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
3
-
-
SEWAGE AND DRAINAGE SYSTEM -S&F PVC (SWR) pipe of size 110 mm single socket in any length with rubber ring joints laid in floor or in trenches with proper connected bends/joints/traps to be provided for proper drainage and sewage complete all as specified and directed.
Note :-
(a) Proper connection to be done to nearby septic tank/soakage well for proper drain out of waste water complete all as specified and directed.
30
-
-
M&L concrete bed to drain pipe including packing under and hunching against the sides of pipe after laid and tested complete all as specified and directed
25
-
-
S&F PVC (SWR) bend of 110 mm bore complete all as specified and directed
6
-
-
Internal Electrification
-
-
-
M&L for point wiring for one light/fan/bell point controlled by one switch one way in and including PVC casing and caping including accessories, ISI marked as per site requirement using FRLS PVC unsheated multi stranded copper conductor unsheathed cable 1.5Sqmm single core for one light/fan/bell point controlled by one switch including 3mm thick plastic laminated sheet cover over PVC box for each earth continuity, insulated PVC unsheathed (green colour) 1.5 Sqmm copper earth wire connected to common earth dolly using complete all as specified and directed by Engineer-in-Charge.
Note:- Wiring shall be done by using proper colour coding.
25
-
-
All as per Serial item No. 3.01 here-in-before but for 5 amp socket outlet on independent board.
5
-
-
All as per Serial item No. 3.01 here-in-before but for 5 amp socket outlet on same board.
3
-
-
All as per Serial item No. 3.01 here-in-before but for 15 amp independent socket outlet using 2.5 sqmm single core copper wire for phase, neutral and earth complete all as specified and directed.
11
-
-
Supply and fixing, switch piano, flush type, single pole, one way, 5Amps, 230V, ISI marked complete all as specified and as directed.
25
-
-
Supply and fix, socket outlet, flush type, 2-in-1 3 pin, 6Amps & 16Amps, 230volts, ISI marked complete all as specified and as directed.
8
-
-
Supply and fix, socket outlet, flush type, 2-in-1 3 pin, 5 and 15Amps , 230volts, ISI marked complete all as specified and as directed.
11
-
-
Supply and fixing lamp holder with LED bulb of 10W, white polycarbonate body, with back plate suitable for batten fitting fixed in position and connecting complete all as specified and as directed.
5
-
-
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type energy efficient LED integrated batten type luminaries suitable for wall or ceiling mounting with built in LED chip and integral LED driver 10W, aluminium channel housing and polycarbonate diffuser, colour temperature 6500K or as directed, luminaire efficiancy not less than 100 lumen/W with all accessories, fixing arrangement internally pre-wired, making all connection using 1.5Sqmm copper conductor multistarnd PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete all as specified and directed.
2
-
-
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
11
-
-
Supply and fixing wall mounting fan of 380mm sweep, suitable to work on single phase AC 230 volts, 50 hz complete with mounting and fixtures, PVC insulated and overall sheathed 3 core flexible copper conductor cable of size 23/0.0076 from ceiling rose to fan complete all as specified and as directed.
5
-
-
Supply and fixing LED bulk head type luminaries with high output, 10W, 220V AC, colour temperature 6500K or as directed, luminous flux of light 1000 lumens complete with all accessories, IP 65 protection dust and water resistant, surge protection upto 2.5Kv, PC opal high efficiency diffuser, LM 80 tested made die cast aluminium housing with complete assembly, suitable for surface/wall mounted with driver holder including connecting up using 1.5Sqmm copper conductor multistrand PVC insulated with three core flexible copper conductor cable of suitable size, complete all as specified and as directed.
1
-
-
Supply and fixing exhaust fan, steel body AC single phase, 230V of size 450mm sweep alongwith blade, frame and louvers complete all as specified and as directed.
4
-
-
Supply and fixing LED street light fitting 30/35 Watt for operating voltage between 110V to 320V system efficiency not less than 120 lumen/watt, PF- 0.95 minimum, IP 66 protection, 5700 CCT (K), CRI between 80-85, conforming to LM79 and LM80 standards or as per IS- 16104:2012 and IS- 16106:2012, for estimated life span of minimum 50000 hrs consisting of high/low voltage cut off, maintenance free isolated electronic driver circuits, Low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with LED street optics lens for uniform light distribution, weather proof gasket for lamp and driver compartment, heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws including necessary GI bracket for fixing on wall complete all as specified and as directed.
4
-
-
Supply and fixing sheet metal enclosure MCB distribution board TPN 415V 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting chases in wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed.
1
-
-
Supply and fix, MCB, SP, 6-32Amps, 240volts, 10KA, 'C' type, ISI marked, complete all as specified and directed.
6
-
-
Supply and fix, MCB, TPN 16-32Amps, 240volts, 10KA, 'C' type, ISI marked, complete all as specified and directed.
1
-
-
Supply and fix, MCB, SPN 32Amps, 240volts, 10KA, 'C' type, ISI marked, complete all as specified and directed.
4
-
-
Material and labour for Sub Main Wiring with Two run single core 4Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including PVC nedium duty conduit of size 20mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including One run of continuous multi stranded copper conductor 4Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity , complete all as specified and directed.
Note:- Two run of 4Sqmm + One run of 4Sqmm for earth wire shall be measured as one RM.
40
-
-
Supply and fixing, sheet metal enclosure MCB distribution board SPN 240 volts ,8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting chases in wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed.
1
-
-
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32 x 6 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc all as shown in Electrical Plate No. 3 of SSR Part 1 including dismantling old, complete all as directed and specified.
1
-
-
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm 4 core aluminum conductor 1100volts grade underground cable ISI marked including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc complete all as specified and as directed.
Note(s): (i) Excavation & earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
80
-
-
Excavation in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5M in depth for laying of GI pipe/cable and getting out of excavated material complete all as specified and directed by Engineer-in-Charge
18.9
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engineer-in-Charge
12.54
-
-
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
6.36
-
-
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, ISI marked for protection of LT cable , complete all as specified and directed.
466
-
-
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed.
Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
5.67
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%