Military Engineer Services Tender

... More
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Military Engineer Services - MES Tender

Works
Electrical Works
Eprocure
Opening Date25 Mar 2025
Closing Date12 Apr 2025
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Summary

Ge/khu-101/2024-25 Repair Replacement Of Security Lights Lightning Conductors Gi Strip Air Termination Rod And Other Allied Wks At Lamayuru Khaltsi Hanuthang

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for fine sand cushioning to UG cable laid in trenches all as specified and directed.

48.6

-

-

... More
Supplying and laying unreinforced precast concrete cable cover, class LV, type 1 flat of size 250mm x150mm x 40mm placed perpendicular of the cable complete.

4000

-

-

... More
Cutting of existing road not exc 1.5 mtr in depth and not exceeding 0.45 mtr wide including providing black top sub base and WBM, well ramming in layers with watering after laying of GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.

18

-

-

... More
Taking out the UG XLPE insulated armoured /unarmoured PVC sheathed laid in trenches/ passing through GI tubing /on pole /on wall of any size and type complete all as specified and directed.

750

-

-

... More
Supply and laying,jointing & testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volt grade laid in trenches,ducts,drawn through pipes across the road/path/along poles/floors/equipment etc of size 16 sqmm 4 core

400

-

-

... More
All as per item srl item No. 08 here-in-before but of size 10 sqmm 02 core

200

-

-

... More
All as per item srl item No. 8 here-in-before but of size 06 sqmm 02 core

150

-

-

... More
Supply installing, testing and commissioning of LT Panel outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Copper bas bar of capacity 250 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- LT panel shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm) . The panels shall be of CPRI approved Note:- Drg of panel shall got approved before execution at site. INCOMMER Incoming MCCB, 415V, 4 pole, 160 Amps, 25 KA, Ics =100% Icu Indicator Lamp-01 Set (Set of three) Voltmeter 0-500 Volt , 415V , 50 Hz ,with selector switches -01 set Ammeter 0- 500 Amps with CTs, 415V 50 Hz with selector switches -01 set OUTGOING MCCB, 415V, 4 pole, 63 Amps, 16 KA -02 No MCB SPN 40 Amps , 230V, 50 Hz - 02 Nos

1

-

-

... More
Supply installing, testing and commissioning of Bus bar junction box panel of size .75x.6x.3 Mtr outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Copper bas bar of capacity 200 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- Bus bar junction box shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm) . Note:- Drg of bus bar junction box panel shall got approved before execution at site. INCOMMER/OUT GOING Incoming MCCB, 415V, 4 pole,100 Amps, 36 KA, Ics =100% Icu -01 nos Indicator Lamp-01 Set (Set of three)

4

-

-

... More
S & F in replacement of existing UNSV HPSV/LED fitting with LED street light fittings 45 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant , IP 65 protection complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.

60

-

-

... More
Checking of street light fittings any type on pole to find out defect /taking out UNSV parts such as driver and repairing by changing the defective parts including minor repairs to cable connection all as speciifed and directed. Note: (i) Minor items like wires themble shall be included inthe qouted rate ii) The T & P Vehicles and necessary ladders etc will be arrange by the contractor and the cost deemed to be inlcuded in the quoted rates. (iii) Major items like LED driver , SPDs shall be measured and paid seperately as per relevent item in the schedule .

200

-

-

... More
M&L for replacing LED driver for 1x36 watts security light 230V, 50 Hz of make Bajaj/Havells/crompton

35

-

-

... More
M&L for replacing LED driver for 1x45 watts security light 230V, 50 Hz of make Bajaj/Havells/crompton

40

-

-

... More
M&L for replacing LED driver for 1x72 watts security light 230V, 50 Hz of make Bajaj/Havells/crompton

30

-

-

... More
M&L for replacing SPD for 1x36 watts security light 230V, 50 Hz of make Bajaj/Havells/crompton

50

-

-

... More
M&L for replacing SPD for 1x45 watts security light 230V, 50 Hz of make Bajaj/Havells/crompton

40

-

-

... More
M&L for replacing SPD for 1x 72 watts security light 230V, 50 Hz of make Bajaj/Havells/crompton

30

-

-

... More
M&L for replacing Air termination, single pointed aluminium rod 12mm dia and 300mm long at different places in the AOR of AGE B/R-II complete incl taking down old/unsv air termination rod along with supporting GI pipe , replacing the termination rod with new incl necessary PCC ,nut bolt and washers all as specified and directed

20

-

-

... More
M & L for replacement of earthing continuity conductor or main earthing lead fixed to wall/roof on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for lightning arrestors /loop earting etc as required 32x6 mm galvanised iron strip incl necessary nut bolt washers and connecting screws complete all as specified and directed .

200

-

-

... More
M&L for replacing Test point terminal block made of gun metal or hosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete including necessary cement work and painting to match with the existing surface

15

-

-

... More
M&L for removing HT/LT over head conductor from the insulator where ever required and restretching the same without any kink/bend upto permissible sag,binding it on insulator by means of binding wire and testing the HT overhead line after completion as directed.(Note: Three/four runs of HT/LT overhead conductor for three phases and neutral shall be measured and paid as one length.)

200

-

-

... More
Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping padestal to poles/support pedestrial of LA including provision of necessary form work finishing the exposed surface even and smooth complete all as specified.

1.2

-

-

... More
Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 complete all as specified.

0.8

-

-

... More
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.

1

-

-

... More
S&F in repair Aluminium conductor, steel reinforced, of size 6/211 to 6/3010 mm (Squirrel to Ferret) straining properly on insulators with and including aluminium tape/winding wire, clamps & jumpers etc. complete all as specified. Note : 3% for sag shall be added in measurement .

0.2

-

-

... More
S&F in repair Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending (cold or hot), drilling holes for bolts, bent to any shape or size as directed and inclusive of one primer coat of red oxide, one under coat of zinc oxide and one finishing coat of aluminium paint complete all as specified.

1

-

-

... More
Supply and fix in replacing LT Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle, two gavanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts complete all as specified and directed.

20

-

-

... More
Supply and fix in replacing Shackle Type, Porcelain, vitreous, white, brown or green insulator working voltage 1100 volt, height 75 mm and dia 90mm including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of size

10

-

-

... More
S&F in repair stay assembly complete with accessories as shown in electrical plate No 1 and diameter of stay rod 16 mm (loop type insulator,stay clamps,excavation and concrete measured separately).

4

-

-

... More
M & L for changing the locks and refixing the doors of LT panels by welding and painting the outer surface of panel complete all as specified and directed

9

-

-

... More
Disconnecting from circuit/bus bar LT and taking out cables for extension of loop/passing through pipe reconnection with circuit and tightening of connections complete all as specified and directed

10

-

-

... More
S&F in replacement of existing unserviceable changeover any size & capacity with changeover 4 pole 100 Amps with side handle operated including minor additional/alternation as required at site for fixing and connecting up of changeover all as directed by Engr-in-Charge.

2

-

-

... More
S&F in repair danger notice plate of 1.6 mm thick mild steel sheet,vitreous enamelled white with letters,figures and conventional skul and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size,for HT,25x20 cm in size.

10

-

-

... More
Supply and fixing G I tubing 40 mm dia light grade galvanised with all fittting and fixed fix on wall ceiling or laid in floors complete all as specified and direceted at site .

36

-

-

... More
M&L for replacing 3 core copper flexible cable 2.5 sqmm PVC un-sheathed FRLS complete all as specified and directed .

200

-

-

... More
S&F in replacing LT cable junction boxes out of polycarbonate with glass fibre reinforced and size not less than 104x104x70 mm ( cable size upto 4 sqmm ) . The polycarbonate junction box shall be environmental friendly , recyclable , halogen and sylicon free, anti acid and anti corrosive with IP rating IP 67/69 in accordance with IEC 60529 weather proof UV resistant , rain water proof and temparature resistant . The gasket material of junction box shall be polyurethane and internally embedded. The junction box comprises of DIN rail and terminal for 3 phase . The degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08 incl 5 pole terminals comany fitted and chromium plated clamps complete all as specified and directed. Cat part no :- KF 0404 B of Hensel or equivalent make in Seimens/GE/ABB

6

-

-

... More
S&F in replacing FRP junction box for LT cable junction for security light along with one MCB SP 6 Amps C series incl DIN rail and 4 nos bus bar for three phase and neutral ize not less than 250x200x120 mm incl cable gland on botton side for cable entry ,size of cable upto 25 sqmm 4 core .The FRP junction box shall be IP65 environmental friendly . Make Syntex/siemens/ABB

50

-

-

... More
S&F in repairs Bollard 20 watts fully aluminium cast body finished with poly urethane paint ( with prior treatment ) of length 647 mm and circular base dimeter of leg of bollard 76 mmsurrounded with fully cast aluminium body finished with ploy urethhane paint with acrylic diffuser with B 22 base for fixing warm white/milky white LED bulb . Total length of bollard fitting 1181 mm complete all as specified and directed . Model No MBL-D-002 of make Mepro electricals / equivalent in Crompton/Bajaj

6

-

-

... More
S&F in repairs Gate light 20 watts fully aluminium cast body finished with poly urethane paint ( with prior treatment ) of length 434 mm and breadth 234 mm along with B22 brass holder , spigot entry 62 mm suitable for 5 to 15W LED bulb with fully cast aluminium body finished with acrylic cover as diffuser .Model No PTL-03 of make Mepro electricals / equivalent in Crompton/Bajaj

4

-

-

... More
Supply and fix in replace unsv PVC heavy duty conduit 25 mm size for fixing on strret light pole from junction box to security light fitting with proper MS clamps (03 Nos) of suitable size with nut bolt and washers for supporting with pole including PVC copper wire multistranded 1.5 sqmm (02 run) from junction box to connector of security light all fixing accessories such as nuts , bolts and wshers complete all as specified and directed . Note: One run of PVC conduit with MS clamp, 02 run of copper wire will be measured as one unit run

788

-

-

... More
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 160 Amps 36 KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.

4

-

-

... More
M&L for replacing Moulded case circuit breaker (MCCB) 4 pole 125A , 50 Hz 16KA breaking capacity complete all as specified and directed.

2

-

-

... More
All as per above but of capacity 100 Amps complete all as specified and directed.

2

-

-

... More
All as per above but of capacity 63 Amps complete all as specified and directed.

5

-

-

... More
M&L for painting of LT/security light steel tubular pole upto 9 mtr length incl MS clamp , bracket, cross arms and metallic junction box with two coat of alumnium paint after preparation of old painted surface and applying metallic primer , providing 03 nos alternative strip of 30 cm wide with black and yellow super quality enamel paint above embedded level and writing pole nos with 02 inch wide letter complete all as specified and directed. Note : Location of pole including all area under the AOR of AGE B/R-II

300

-

-

... More
M&L for replacing security light GI braket made ou of GI pipe 32/40 mm size 1.2 Mtr length bend to size at 120 degree complete with connecting clamp (02 Nos) , nut , bolt washers, paiting with 02 coat of synthetic aluminium paint incl surface preparation and primer coat all as specified and directed

30

-

-

... More
M&L for replacing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete incl taking down old unsv light fitting.

30

-

-

... More
M&L for replacing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete incl taking down old unsv light fitting.

30

-

-

... More
M&L for replacing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete incl taking down old unsv light fitting.

30

-

-

... More
M&L for replacing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp incl taking down of old /unsv light fitting all as specified and directed

10

-

-

... More
M&L in replacing LT line seperator made of PVC 4 line complete with screws, bolts , nuts all as specified and direted.

60

-

-

... More
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.

4

-

-

... More
Deduct Credit for Demolished/Dismantled material Rs (-) 26308.00 (Minus) as listed in Schedule 'A' Sec-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.