Military Engineer Services Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673738_1Bid Award Id
ViewTender No
COMPREHENSIVE MAINT/REPAIR /RENEWAL WKS TOTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for non skid coloured ceramic tiles of 7 to 8 mm thick , area of each tile exceeding 0.18 sq m but not exceeding 0.38 Sq m in floors set and jointed in neat cement slurry and pointed in white cement mixed with colour pigment to match over & Incl screed layer of 15 mm thick in CM 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and as directed.
90
-
-
S/F of Glazed coloured and cereamic tiles in vertical surfaces 300X200X7mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over backing coat 10mm thick in rendering of cement mortar 1:4 for laying skirting dados and vertical surfaces including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises all as specified and directed
60
-
-
S&F Vitrified ceramic tiles 9-10mm thick (Square/rectangular)polished area of each tiles n.exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured (Light Shade)cement to match over & incl 20 mm thick screed bed or bedding layer of cement mortar(1:6) for laying floor finishes including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises all as specified and directed
20
-
-
Demolition of Stone slabs and tiles laid bedded on sand/cement pointed in mortar of any description or thickness in floors, aprons etc.
40
-
-
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement and pigment used, excluding laying of sand cushioning complete all as specified and as directed.Note :- Sand will be measured and paid seperately
400
-
-
M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
10
-
-
Demolition of cement concrete (unreinforced) in ground floor any type and any position and paving including PCC tiles any type n exc (below or above GL) all as specified.
24.5
-
-
M&L for 75mm thick, cement concrete, type C-2, 1:3:6 (40 mm graded stone aggregate) as in floors & pavings, plinth protection, path, etc. finishing top surface even and Smooth with using extra cement all as specified.
10
-
-
M&L for 100 mm PCC cement concrete type D-2 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified
240
-
-
M&L for wooden floor tiles of size 1200 x 200 mm and 7 mm thick with dove tailed joints laid over 150 Micron polythene film and 3mm thick foam as per manufacturers instructions including taking down of old wooden flooring any type and fixed with decorative wooden beadings as per site requirement complete all as specified and directed by Engr-in-charge, complete.
30
-
-
Dismantling wall and ceilling boards of any description including cover fillets complete.
420
-
-
M & L 9 mm thick Prelaminated Partical Board interior grade prelamination one side & other side balancing white lamination fixed with nails to timber frame work as in ceiling.
100
-
-
M & L 11 to12 mm thick Prelaminated Partical Board interior grade prelamination one side & other side balancing white lamination fixed with nails to timber frame work as in wall.
320
-
-
Dismantling timber scantling 40 sqcm and over in section unframed work in any position complete all as specified and directed.
0.4
-
-
M&L 2nd class HW in scantling clean sawn timber fixed with nails complete all as specified and directed.
0.4
-
-
Dismantling timber fillets, rails, posts rafter purlins under 40 Sqcm in sectional area.
785
-
-
S&F 2nd class HW plain fillets Square rectangular/triangular in section clean sawn secured with nails sec area exc 13 & n.exc 25 sqcm complete all as specified and directed.
350
-
-
S&F 2nd class HW plain fillets square rectanular, triangular in section wrought with nails sectional area exc. 6 and n.exc 13 sqcm complete all as specified and directed.
140
-
-
S&F 2nd cl HW plain fillets square rectangular, triangular in section wrought with nails sectional area exc. 3 and n.exc 6 sqcm complete all as specified and directed.
95
-
-
S&F 2nd cl HW plain fillets square rectangular, triangular in section wrought with nails sectional area n'exc. 3 Sqcm as in beadings complete all as specified and directed.
200
-
-
Dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed.
70
-
-
Supply & Fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed.
60
-
-
Supply & Fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall/ridges, fixed with self tapping screws as complete all as specified and directed.
10
-
-
M&L for cement concrete type C-2 1:3:6 using 40mm graded stone aggergate as in foundations filling and mass concrete complete all as specified and directed by Engr-in-charge.
0.3
-
-
Roof truss (framed) trussed, purlins crane gantries, rails and fastenings and heavy bracket framing (Beam tee, angle,hollow section, channel or flat sections) inclusing distance pieces,cleats etc Fe 410-W (Gde E-250) quality B, complete all as specified and directed.
100
-
-
M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over red lead primed steel surfaces complete all as specified.
10
-
-
S & F in repairs door closer (cast iron) hydraulically regulated designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
10
-
-
S&F in repair Rotational moulded Polyethylene water storage tank of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm PVC float valve high pressure with polythene float valve & taking down old PVC water tank complete all as specified and as directed. (Make : Sintex, Sheetal, Polycon or equivalent)
6
-
-
S&F in repair Rotational moulded Polyethylene water storage tank of 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm PVC float valve high pressure with polythene float valve & taking down old PVC water tank complete all as specified and as directed. (Make : Sintex, Sheetal, Polycon or equivalent.
5
-
-
S&F in repair PVC low level flushing cistern 9/10 ltrs capacity with float ball valve and bracket including fixing of flush pipe (dia 32 mm) complete all as specified.
6
-
-
S&F Vitreous china wash down water closet pan (pedestal pattern)white/coloured cascade type 640X360X690 (monolithic flush cistern type) Make: Parryware C849P (S-110) (640 x 355 x 695mm) White/ Jaguare Model NO:SLS WHT-6853S/CERA Cat No: s1013132s or equivalent single picece wc with PP seat cover ,Hinges fixing accessories set including flush cistern with S-Trap of size 220mm all as per manufacturing instructions and all as specified and directed. (Make:Jaguor/Parryware or Equivalent)
2
-
-
Taking down carefully copper/ aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface etc.
300
-
-
Material and labour for point wiring with 1.5 sqmm single core PVC insulated , unsheathed FRLS multi stranded copper cable , 1100 volt grade with necessary termination board in and incl PVC heavy duty casing n caping ISI marked on wall/ceilings including 1.5 sqmm single core PVC insulated multistranded copper conductor cable green in colour as earth earth continuity conductor connected to common earth dolley as rquired at site along with all accessories and making good the disturbed surfaces of wall/ ceiling etc for the following : - Note :- Colour coding for point wiring should be maintained at site. Incase of any deviation necessary recovery will be made as applicable.
-
-
-
(a) One light point/ one fan point/ Bell Point controlled by one switch.
160
-
-
(b) One 3 pin socket outlet, 5 Amp independent with other switches.
60
-
-
(c) All as per item 36 (b) here - in - before but One 3 pin socket outlet 5Amps on same board with other switches .
30
-
-
All as per item No 36 above but for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing caping heavy duty ISI marked /heavy duty conduit ISI marked as required at site alongwith accessories with 2.5 Sq mm FRLS PVC insulated unsheathed copper conductor cable as earthing wire and connected to common earth dolly complete all as specified.
50
-
-
S & F in repair switch socket combination 15 amp ,230V, 50 Hz flush type all as specified.
50
-
-
S & F in repair Switch socket combination 5A , 230V, 50 Hz all as specified.
90
-
-
S&F in repair switch piano flush type single pole one way 5 amp , 230V, 50 Hz all as specified.
145
-
-
S&F in repair Batten holder PVC/ poly carbonate typen with cord grip cap incl taking old one all as specified
65
-
-
S&F in repair Bell electronic ding dong AC 230Volts 50 Hz all as specified.
15
-
-
S&F in repair bell push flush type single pole one way 5 amp , 230V, 50 Hz all as specified.
15
-
-
S & F in repair Ceiling rose 3 terminals complete all as specified & directed
250
-
-
S&F in replacment of decorative ultra slim polycarbonate LED 4 feet long 20/22 watts with THD less than 15% very high efficiency suited for T-8 tube luminare with system efficacy 110 lumen per wattsb , high quality poly carbonate end cap in white finish and snap fitted to the housing, inbuilt driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed. .
600
-
-
S&F in replacement of wall mounted 10 watts LED batten 2 feet long comprising extruded aluminium heat shrink provided for efficient heat dissipation and integrated lectronic driver with aluminium housing , system efficiency of 110 lumen per watts and lumen package = 1100 lumen , THD 10 % incl copper connecting wire three core of suitable size upto connctor of ceiling rosecomplete all as specified and directed.
50
-
-
S&F in replace LED building security light fitting 30 watts made of pressure diecast aluminium housing with acrylic cover as diffuser with IP65 and IK -07 protection , THD10%, lumen output = 110 lumen per watts with integrated lectronic driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed.
80
-
-
S&F in replacing GI mounting pipe of building security lights of size 32 mm to 40 mm size upto 1.2 mtr length bend into sizes incl mounting clamps made of MS flat saddles, nut bolt and washers all as specified and directed .
40
-
-
M&L for replacing LED bulk head fittings of wattage 6 to 13 watts deigned for modern homes , glare free lights and easy to install snapfit installer complete including making good of surface complete all as specified and directed.
25
-
-
S&F in replace warm white/ white LED luminaire 600X600 mm,35/36 watt,220V recessed type lumen output = 122 lumen per watts , THD 10% environmental friendly , new generation , aesthetically designed , ultra modern with high brightness SMD LEDs as light source incl inbuilt drivers with high efficiency PMMA diffuser soft glare free light complete suitable for roof ceiling including connecting up with three core flexible copper conductor of suitable size all as specified and directed.
30
-
-
S&F in replacing distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface incl making good of surface complete all as specified and directed incl taking down old one
25
-
-
S&F in replace distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete incl making good all as specified and directed.
25
-
-
S&F in replacing distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one
10
-
-
S&F in replacement MCB DB TPN double door 4 way three phase vertical type , 415 volts with MCCB as incommer and MCB/ISOLATOR SP as outgoing incl three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following ;
INCOMMER
(a) MCCB 4 Pole 100 AMPS AC 415 V 16 KA=01 No OUTGOING (a) MCB SP 63 Amps C curve - 04 Nos (b) MCB SP 40 Amps C curve - 08 Nos Note :- (i)The DB shall be of VTPN series (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly.
4
-
-
S&F in repair MCB single pole, 6 to 32 Amp 240 volt C curve 10 KA breaking capaity complete all as specified and directed incl taking down old one
200
-
-
S&F in repair MCB SPN 40 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one
40
-
-
S&F in repair MCB SPN 63 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed incl taking down old one
25
-
-
Taking down old u/s submain wiring of any sizes complete incl conduits/PVC casing n caping all as specified & directed.
500
-
-
M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 6 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 6 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed.
Note :
1. Two run of main copper conductor 6 sqmm size , one run of 6 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length .
2. Proper colour coding shall be maintained as per IS code.
200
-
-
M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 4 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 4 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed.
Note :
1. Two run of main copper conductor 4 sqmm size , one run of 4 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length .
2. Proper colour coding shall be maintained as per IS code.
300
-
-
Taking down old u/s undergound cable/service cable of any sizes complete all as specified and directed
180
-
-
Supply and fixing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor cable 1100 volts grade laid in trenches / passing through GI pipe / on pole / on wall of size 10 sq mm 2core complete all as specified .
180
-
-
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in hard soil complete all as specified and directed. (cable shall be laid 60 cm below ground level )
38.88
-
-
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
22.68
-
-
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
13.41
-
-
Sand cushioning for cables with hight of cushioning as 8 cm below the cable and 15 cm above the cable all as specified and directed .
14.9
-
-
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-1, flat, size 250mm x 150mm x 40mm complete all as specified and directed
960
-
-
Supply and fixing G I tubing 40 mm dia light grade galvanised with all fittting and fixed fix on wall ceiling or laid in floors complete all as specified and direceted at site .
12
-
-
M&L for repair/replacing PCC 1:3:6 using 20 mm graded stone aggregate of required shape incl necessary form work , rendering with cement mortar 1:4 finishing complete incl two coat of distumbering as per approved colour duly making surface preparation and two coat of cement primer all as specified and directed. of post top lantern/bollards incl necessary form works
1.82
-
-
S&F in replacing LT cable junction boxes out of polycarbonate with glass fibre reinforced and size not less than 104x104x70 mm ( cable size upto 4 sqmm ) . The polycarbonate junction box shall be environmental friendly , recyclable , halogen and sylicon free, anti acid and anti corrosive with IP rating IP 67/69 in accordance with IEC 60529 weather proof UV resistant , rain water proof and temparature resistant . The gasket material of junction box shall be polyurethane and internally embedded. The junction box comprises of DIN rail and terminal for 3 phase . The degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08 incl 5 pole terminals comany fitted and chromium plated clamps complete all as specified and directed. Cat part no :- KF 0404 B of Hensel or equivalent make in Seimens/GE/ABB
10
-
-
M&L for replacing 3 core copper flexible cable 2.5 sqmm PVC sheathed FRLS complete all as specified and directed .
310
-
-
Supply and fix in replace unsv casing and caping 25mm/PVC heavy duty including all fixing accessories complete all as specified and directed .
392
-
-
S&F in repairs Bollard 20 watts fully aluminium cast body finished with poly urethane paint ( with prior treatment ) of length 647 mm and circular base dimeter of leg of bollard 76 mmsurrounded with fully cast aluminium body finished with ploy urethhane paint with acrylic diffuser with B 22 base for fixing warm white/milky white LED bulb . Total length of bollard fitting 1181 mm complete all as specified and directed .
Model No MBL-D-002 of make Mepro electricals / equivalent in Crompton/Bajaj
6
-
-
M&L for earthing complete with galvanized steel earth plate electrode60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0 mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified and directed.
2
-
-
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor ,served with inner sheathing of PVC tape and overall PVC sheathed in service connections two core of size 6 sq mm flat or circular complete all as specified and directed
56
-
-
S&F in replacing distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 2 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed incl taking down old one
30
-
-
Deduct Credit for Demolished/Dismantled material Rs (-) 60,363.00 (Minus) as listed in Schedule 'A' Sec-II (Credit Schedule)
Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
-
-
-