Military Engineer Services Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 42,420Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_695639_1Tender No
TOKEN NO. GE/K-84/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply & fixing 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap bent to curve, with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed.
54
-
-
... More
M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer including preparation of surface.
61.56
-
-
... More
M&L for preparing old wooden surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed.
3
-
-
... More
M&L for preparing old steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed.
120
-
-
... More
Demolition of concrete of any description and in any position and removal of rocks/debris to a distance not exc 50 mtrs and depositing where directed at a level n exc. 1.5 m above the starting point.
9.08
-
-
... More
M&L for 75 mm thick plain cement concrete 1:3:6. type C-2 (using 40mm graded aggregate) as in plinth protection and subbase to floors complete all as specified and directed.
121
-
-
... More
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed
12
-
-
... More
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete incl 20mm thick screed bed in CM 1:6 complete all as specified and directed .
120
-
-
... More
Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed.
2
-
-
... More
Supply & fixing 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
2
-
-
... More
Suface dressing n.exc 15cm deep in hard/dence soil.
16.41
-
-
... More
Excavation over area n.exc 1.50m deep and getting out in hard / dense soil
22.43
-
-
... More
Excavation over area exc 1.50m but n.exc 3.00m deep and getting out in hard / dense soil
0.72
-
-
... More
Excavating in trenches n exc 1.5 m in depth for foundation, & n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in hard / dense soil
57.05
-
-
... More
M&L for cement concrete 1:4:8 type D2(using 40mm graded stone aggreagte) as in foundation filling, sub base and mass concrete complete all a specified
3.6
-
-
... More
M&L mild steel TMT bars 10mm and over in dia,cut to length bent to shape required,including cracking,bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
1012
-
-
... More
M&L mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified
427
-
-
... More
Form work to sides of concrete fdn footing base of columns and raft beams sides and soffits (if any) of fdn and plinth beams and similar wk vertical or to batter for rough finished surfaces complete all as specified
46.93
-
-
... More
Form work to sides of pillars, post, struts, piers, columns ans stanchions in rough finished surfaces Square, rectangular or polygonal complete all as specified
38.8
-
-
... More
M&L for reinforced cement concrete mix 1:1.5:3 (using 20mm graded stone aggregate as in foundations incl raft footing, foundations beams, plinth beams, bases for column etc, basement slabs under rammed piles and mass concrete complete all as specified
4.1
-
-
... More
M&L for reinforced cement concrete mix 1:1.5:3 (using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified
2.3
-
-
... More
Returning filling incl spreading leveling watering and well ramming in layers not exceeding 25 mm in any type of soil.
47.81
-
-
... More
Removing excavated material not exc 50m and depositing where directed at a level n. exc. 1.50m above the starting point etc complete all as specified and directed
34.24
-
-
... More
M&L for 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using granite dust with admixture of pigment to match with shade of granite all as specified
17
-
-
... More
Supply & fixing Fe-290 (Gde E-165) Framed work as in door or gates of angle or other section with gusset plates rails, braces etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fiting (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete
1335
-
-
... More
Supply & fixing 1.60 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screw, clouts nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turnning up, mitred angle etc as required complete all as specified
54.08
-
-
... More
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer.
169.72
-
-
... More
M&L fo MS heavy duty adjustable sliding gate guide roller with suitable dia complete all as specified.
11
-
-
... More
M&L for reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregate as in foundations incl raft footing, foundations beams, plinth beams, bases for column etc, basement slabs under rammed piles and mass concrete complete all as specified.
3.7
-
-
... More
M&L for reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified
1.92
-
-
... More
RCC (Design mix) M-25 using 20mm graded stone aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
1.65
-
-
... More
M&L for Precast cement concrete Type C1 ,(1:3:6) (using 20mm graded crushed stone agg) block masonary with solid blocks exc 10cm in width and setting in CM 1:4, complete all as specified and directed by Engr-in charge.
9
-
-
... More
Rendering 15mm thick on fair faces brick surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified.
72
-
-
... More
Preparing newly plastered surfaces and applying two coat of cement base paint over a coat of primer complete all as specified.
72
-
-
... More
Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts, clamps and accessories complete complete all as specified and directed by the Engr-in-Charge.
30
-
-
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
5.4
-
-
... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed.
3.22
-
-
... More
Factory made ISI marked un-reinforced precast cement concrete cable cover of PCC 1:1.5:3 type A-1, conforming to class LV, flat of size 250mmx150mmx40mm, laid dry over electric cable for protection all as specified.
133
-
-
... More
Supply & fixing in replacement of post top lantern LED 45W 220v, 50Hz, IP65 including inbuilt high efficent electronic driver & grouting of GI tubing of dia, including GI tubing length as per requirement on gate pillars for fixing the lamp, wiring with 1.5 sqmm PVC insulated standed copper conductor in and including concealed conduit on gate piller and conectting the lights with the nearest street light feeders/switch control as per site requirment all as specified and directed . Make : JAQUAR Cat part No. OBL-GRY-LGTP01X030XW or equivalent in WIPRO Cat part No LP09S-501-XX-57-XX or equivalent in SURYA Cat part No. SLE PT 40W-NAVI
2
-
-
... More
Supply & fixing sheet metal enclosure for DB's single door, single pole and neutral, 240V, 2 way including blanking plates where required, complete all as specified and directed.
1
-
-
... More
Supply and fixing 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 32 Amp in the MCB DB complete with connection testing and commissioning.all as specified and directed by Engr-in-charge.
1
-
-
... More
M&L for submain wiring comprising single core, 2 Runs of 1.5 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 25mm dia. PVC conduit ISI Marked(heavy duty) and its fittings on recessed complete including provision of 1X1.5.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS complete all as specified and directed by Engr-in-charge.
16
-
-
... More
Supplying and laying as in repairs GI tubing medium grade incl all accessories for passing of cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works complete all as specified and directed by the Engr-in-Charge.
8
-
-
... More
M&L for LT UG cable 3.5 core x 120 sq mm 1100 Volts grade XLPE insulated , armoured, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable gland lugs/ thimbles/ ferrules including connecting, testing and commissioning complete for the following sizes including taking down existing LT UG cable of any size at site all as specified and as directed.
Notes:
(a) Excavation ,RFR, and protection pipe etc. Shall be measured and paid separately under relevant item of schedule (b) Rate quoted deemed to include for cutting and removing of defective joints where required as directed.
212
-
-
... More
M&L for sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.
15.63
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm laid dry over electric cable for protection complete all as specified and directed by the Engr-in-Charge
1153
-
-
... More
Supply and fixing GI tubing light grade 80 mm bore as in cable protection fixed to poles/walls or laid in trenches/under road crossing etc. all as specified and as directed.
30
-
-
... More
Supply, installing, testing and commissioning factory made LT (415 Volts, 50 Hz, 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 200 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class (IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 5 mm), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
1
-
-
... More
BUS BAR CHAMBER :- (a) 200 Amps 3 Strips & Netural, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
INCOMING SUPPLY :- (i) MCCB 160 Amps 25 KA 4 Pole with Thermal Magnetic release 415 volts , 50Hz,=01 No., Make of MCCB:-L&T/ Schneider / Legrand.
INSTRUMENT FEEDER :- (a) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with Volt meter selector switch- 01 Set. (b) Digital Amp Meter, 96X96mm, flush type rated 0-200 A, with Amp meter Selector switch- 01 Set. (c) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)
(d) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).
(e) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider.
-
-
-
... More
OUTGOING SUPPLY :- (i) MCB 32 Amps 10 KA SPN 415 volts , 50Hz - 08 Nos, Make of MCB:- L&T/ Schneider / Legrand.
The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011)
2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)
3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk
4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V
5. ISO 9001 CERTIFIED
-
-
-
... More
Supply, installing, testing and commissioning factory made LT (415 Volts, 50 Hz, 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 200 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class (IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 5 mm), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
1
-
-
... More
BUS BAR CHAMBER :- (a) 200 Amps 3 Strips & Netural, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
INCOMING SUPPLY :- (i) MCCB 160 Amps 25 KA 4 Pole with Thermal Magnetic release 415 volts , 50Hz,=01 No., Make of MCCB:-L&T/ Schneider / Legrand.
INSTRUMENT FEEDER :- (a) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with Volt meter selector switch- 01 Set. (b) Digital Amp Meter, 96X96mm, flush type rated 0-200 A, with Amp meter Selector switch- 01 Set. (c) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)
(d) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).
(e) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider.
-
-
-
... More
OUTGOING SUPPLY :- (i) MCCB 100 Amps 16 KA 4 Pole with Thermal Magnetic release 415 volts , 50Hz,=01 No., (ii) MCCB 63 Amps 16 KA 4 Pole with Thermal Magnetic release 415 volts , 50Hz,=01 No., (iii) MCB 32 Amps 10 KA SPN 415 volts , 50Hz - 04 Nos, Make of MCB:- L&T/ Schneider / Legrand.
The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011)
2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)
3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk
4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V
5. ISO 9001 CERTIFIED
-
-
-
... More
Supply, installing, testing and commissioning factory made LT (415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 200 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class (IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 5 mm), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
1
-
-
... More
BUS BAR CHAMBER :- (a) 200 Amps 3 Strips & Netural, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
INCOMING SUPPLY :- (i) MCCB 160 Amps 25 KA 4 Pole with Thermal Magnetic release 415 volts , 50Hz,=01 No., Make of MCCB:-L&T/ Schneider / Legrand.
INSTRUMENT FEEDER :- (a) Digital Volt Meter, 96X96mm, flush type rated 0-500 V, with Volt meter selector switch- 01 Set. (b) Digital Amp Meter, 96X96mm, flush type rated 0-150 A, with Amp meter Selector switch- 01 Set. (c) C.T's 150/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)
(d) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).
(e) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider.
-
-
-
... More
OUTGOING SUPPLY :- (i) MCCB 63 Amps 16 KA 4 Pole with Thermal Magnetic release 415 volts, 50Hz=01 No., (ii) MCB 32 Amps 10 KA, SPN 415 Volts, 50Hz -06 Nos,
Make of MCB:- L&T/ Schneider / Legrand.
The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011)
2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)
3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk
4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V
5. ISO 9001 CERTIFIED
-
-
-
... More
Supply & fixing in replacement of CI LT cable route indicator of size 125 MM dia , thickness 8mm with MS angle height 0.6 M with embosed letters "LT CABLE" and embedded in PCC 1 :3:6 (150 x150 x150 mm) Type B2 including earth work complete all as directed.
6
-
-
... More
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip 32×6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. GI Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :-
(a) GI strip 32x6 mm.
(b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (MS Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)
(c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
6
-
-
... More
Note : Deduction for amount of Rs. 26,690.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%