Military Engineer Services Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 8,64,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Summary
Provision Of Wksp Repair Est At Leh Under Ge I P No 1 Leh
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_668019_2Tender No
180100Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Total amount of Sch ‘A’ Part - III (PROTECTIVE WORK)
1
-
1937473.25
Total amount of Sch ‘A’ Part - IV (ROAD WORKS)
1
-
4263286.56
Total amount of Sch ‘A’ Part - V (SEWAGE DISPOSAL WORKS)
1
-
201990.3
Total amount of Sch ‘A’ Part - VI (SECURITY WALL WORKS)
1
-
12546801.62
Total amount of Sch ‘A’ Part - VII (INTERNAL WATER SUPPLY WORKS)
1
-
29890.82
Total amount of Sch ‘A’ Part - VIII (INTERNAL ELECTRIC SUPPLY WORKS)
1
-
971164.38
Total amount of Sch 'A' Part - IX (EXTRNAL WATER SUPPLY WORKS)
1
-
816056.45
Total amount of Sch 'A' Part - X (EXTRNAL ELECTRIC SUPPLY WORKS)
1
-
4917151.01
Total amount of Sch ‘A’ Part - XI ( STREET LIGHT WORKS)
1
-
1093585.98
Total amount of Sch ‘A’ Part - XII ( STANDBY DG SET FOR CHS WORKS)
1
-
205559.1
SCH 'A PART - XIII (Miscellaneous B/R and E/M works for Sch 'A' Part-II to Part-XII)
Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
-
-
-
Supplying and fixing 30 users LLDPE septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft , connection etc conventional type complete all as specified and directed by Engrs-in-Charge.
1
-
-
Supplying and fixing 10 users LLDPE septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft , connection etc conventional type complete all as specified and directed by Engrs-in-Charge.
1
-
-
Construction of soakage well 2.4m internal dia and 3.00m effective depth including excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings.
1
-
-
Construction of soakage well 1.2m internal dia and 3.00m effective depth including excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings.
1
-
-
Supplying and fixing for Concertina Coil Punched type 600mm dia , Central core wire - made from high tensile , spring steel - high carbon wire conforming to IS 4454/Part-/Garde-Sm duly hot dipped galvanized with diameter staring from 2.50mm, UTS 1670N/mm2, heavy zinc coating with minimum 230gms per srm. Razor punched tape - galvanized steel strip As per IS 513/D.D Grade/2004, with concertina clips heavy duty J clipsto be used for making concertina coils which is made from steel Fe410 complete all as specified and directed.
1041
-
-
M & L for MS wicket gate as Ref drwg- CELZ/TD/ST-11/2017 SHEET 1R/1 Complete all as specified and directed by Engrs-in-Charge.
2
-
-
M & L for 5.5 Mtr Wide gate with pillers Ref drwg- CELZ/TD/ST-11/2017 SHEET 1R/1 Complete all as specified and directed by Engrs-in-Charge.
1
-
-
Supply, Install, lowering, testing, and commissioning of submersible openwell pumping sets, centrifugal, electric driven,minium discharge of 23.46 LPM at 33 mtr head motor capacity minium 3 HP including 3 HP Starter complete all specified and directed.
2
-
-
Supply, installation, testing and commissioning of LT Feeder Pillar Box, out door type, vermin proof, front door openable, made out of CRCA Sheet 3.15 mm thick, duly powder coated, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following.
a) Bus bar chamber with and including copper strips (set 4 nos) suitable for 100 amps duly insulated wired & duly mounted on porcelain insulators b) Incommer MCCB 4 Pole 440 Volts, 40 Amps rating with repturing capacity 16 KA - 1 No
c) Outgoing MCCB 4 Pole, 16 Amps rating with repturing capacity 16 KA - 2 No (for Openwell Submersible pumpset)
d)Three Ph LED electronic Ammeter Class 1 with in built selector switch having range 0 to 100 Amp - 01 No
e) Three Ph LED electronic Voltmeter Class 1 with in built selector switch having range 0 to 500 Volts- 01 Nos
f) Indicator RYB . LED type- 1 Set.
g) All accessories prewired with appropriate size copper strip or wire thimbles etc.
h) Space for Provn of DOL starter 3 HP - 02 Nos
All as required including foundations as per Manufacturers recommendations all as required at site or as directed by Engr-in-Charge.
1
-
-
Supply and fix submersible copper conductor cable 3 core, 4 sqmm 1100 volt flat industrial grade including nylon binding wire and accesories to clamp with column pipe at two places to each column pipe complete all specified and directed.
80
-
-
M&L for Construction of brick masonary valve pit of size.0.9X0.9X1.8 mtr (internal diamensions) including excavation and earth work in any type of soil, PCC 1:4:8 type B-2 in foundation brick work in CM 1:4, 15mm thick plastering in CM 1:4 internally and flush pointing externally in same mortar as the work process angle iron frame 40X40X6mm, with 3mm thick MS sheet cover with 12 mm dia handle and locking arrangement (including lock and two Keys) and two coats of synthetic enamel paint over a coat of red oxide primer, filling saw dust into the pit and providing extension rod 0.6 m long to operate sluice valve from top and welding it with sluice valve spindle all as specified and directed by Engr-in-charge.
3
-
-
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.5m x 1.2m x 0.7m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including the following :- (Prop Main LT Panel)(Near Prop Transformer)
(a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 2400 Amps.
(b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1600 Amps - 01 No for incoming
1
-
-
(c) MCCB 4 Pole, 415 V, 36 KA, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 02 No O/G (for Prop Sub LT Panel, Spare)
(d) ACB 800 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No O/G (for CHS LT Panel) (e) MCCB 25 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 03 No O/G (for High Mast light No.1,2 & Feeder Pillar box)
(f) Indicator Lamp LED type (RYB) - 01 Set (g) Digital type Ammeter 3 Ph with in built selector switch suitable up to 1600 Amp including suitable rating CTs -01 Set
(h) Digital type Voltmeter 3 Ph with in built selector switch suitable up to 500 Volt - 01 Set
(j) All accessories prewired with appropriate size copper strip or wire thimbles etc.
All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge.
-
-
-
Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.2m x 1.2m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including the following :- (Prop Sub LT Panel)(Near workshop bldg)
(a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 1000 Amps.
(b) MCCB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 01 No for incoming
1
-
-
(c) MCCB 250 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No O/G (for VTPN DB No.1)
(d) MCCB 63 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 Nos O/G (for VTPN DB No 2)
(e) MCCB 160 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 Nos O/G (for VTPN DB No 3)
(f) MCCB 100 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No O/G (for VTPN DB No 4)
(g) Indicator Lamp LED type (RYB) - 01 Set (h) Digital type Ammeter 3 Ph with in built selector switch suitable up to 400 Amp including suitable rating CTs -01 Set
(j) Digital type Voltmeter 3 Ph with in built selector switch suitable up to 500 Volt - 01 Set
(k) All accessories prewired with appropriate size copper strip or wire thimbles etc.
All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge.
-
-
-
Supply, installation, commissioning and testing of factory made, CPRI approved feeder piller box of size 0.9m x0.9m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including fwg:- (Feeder Pillar box) (Near washing platform)
1
-
-
(a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 50 Amps.
(b) MCCB 25 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No incomer
(c) MCCB 16 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No outgoing
(d) Earth plug socket 3 ph 415 V, 32 Amp - 01 No
(e) Switch socket combination 5/15 Amps 5/6 pin - 02 Nos
(f) Indicator Lamp LED type (RYB) - 01 Set (g) Digital type Ammeter 3 Ph with in built selector switch suitable up to 400 Amp including suitable rating CTs -01 Set
(h) Digital type Voltmeter 3 Ph with in built selector switch suitable up to 500 Volt - 01 Set
(j) All accessories prewired with appropriate size copper strip or wire thimbles etc.
All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge.
-
-
-
Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
32
-
-
Supply, Installation, Testing & Commissioning of High galvanized mast light suitable for 8 luminaries symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation suitable for 12.5 Mtr height completed minimum dimension specified as under mentioned specifications.
(A) High Mast Structure
1. Matrial of Construction:- HR sheet steel conform to IS 2062/BS EN 10025 or Equivalent
2. Base Dia. and top diameter (A/F) 1. Top Section - 150 mm 2. Bottom Section - 360 mm
3. Plate thickness :- Top - 3mm, Bottom - 3 mm
4. Cross Section of Mast (Number of Slides) - 20 Sided Polygon
5. Standard of galvanisation - As per BS EN ISO 1461
6. Size of opening and door at base - 1050 x 225 mm
7. Diameter of base plate - 520 mm
8. Thickness of base plate - 25 mm
9. Lighting protection finial - G.I single spike
10. Max. wind speed - 50 m/s as per IS : 875 (Part -III)
11. Number of foundation bolts - 4 nos
12. Type/ diameter/ length of foundation bolts - TS 600/ 24 mm dia/ 850 mm long
13. PCD of foundation bolts - 445 mm
2
-
-
(B) Luminaires Carriage :- 1. Material of construction - 40 NB ERW Class B - M.S. pipe
2. Diameter of carriage ring (mm) - 450 mm (ID)
3. Construction - 4 Arm, welded, 2 sections
4. Load Carrying capacity - 08 Luminaires
(C) Trailing Cable :- 1. Conductor - Copper, 5 core, 2.5 Sqmm 2. Insulation - PVC insulated
3. No of circuits per mast - One no. cable per mast (D) Winch/ Power Tool
1. Type /SWL of winch - Double drum, SWL 350 Kg
2. Method of seperation - Integral Motor
3. Motor capacity - 0.75 HP
4. No of speeds - 6 pole, single speed
5. Torque limitor - with mechanical tripping facility
(E) Stainless steel wire rope 1. Grade/ Construction - AISI 304, 7/19 construction
2. No of ropes - Two continuous
3. Diameter (mm) - 5 mm
4. Breaking load capacity - 1350 Kg x 2
-
-
-
S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 250 Amps rating with rupturing cap 36 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
1
-
-
S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
1
-
-
S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
1
-
-
S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
1
-
-
S & F, installation, commissioning and testing Junction boxes made of Lid PC and base is polystyrene Hensel reference : KG series suitable . Junction Boxes Size 217 x 253 x 115 mm in Grey RAL 7035 colour. Junction Box IP 65 Thermoplastic PS Polystyrene weatherproof Junction Box with multi level knockouts for cable glands in different sizes. The pre-moulded knockouts shall be available on top and bottom of the junction box to enable cable entries from both direction. The junction box shall have an optional cable entry at the bottom up Cable Size 25 Sq mm of the box via pre-moulded knockout to enable pole mounting option. Lid fasteners self closed will be tool operated. it will be sealable with accessories. The junction box shall have elongated holes inside them for wall/pole mounting provision. The junction box with 4 Pole Terminal Strip and MCB SP 6 Amp 10 KA C Curve for LED light. In the event of formation of condensed water, the junction box shall have a minimum of two condensation knock-outs inside to ensure optimum safe performance.
22
-
-
The junction box shall fulfill the following standards
Weatherproof : Rainwater proof, temperature resistant.
IEC 60670-22 : Particular requirements for connecting boxes and enclosures.
IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C.
IEC 60529 : IP 65 degree of protection.
UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4
The Junction Box with Suitable Glands 3 Nos with each and chromium plated clamps, nut bolts complete all as per manufacturer’s instructions.
-
-
-
Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (Main LT Panel )
INCOMING:
(a) Aluminium bus bar 3 phase 4 strip suitable for 600 Amps current carrying capacity complete with post insulators and heat shrinkable sleeves- 01 No.
(b) MCB TPN, 415 V, 10 KA, with Thermal Magnetic Release of capacity 16 Amps - 01 No Incomer
1
-
-
OUTGOING:
(c) MCB TPN, 415 V, 10 KA, with Thermal Magnetic Release of capacity 10 Amps - 02 Nos O/G
(d) Indicator Lamp LED type (RYB) - 01 Set (e) Digital type Ammeter 3 Ph with in built selector switch suitable up to 100 Amp including suitable rating CTs -01 Set
(f) Digital type Voltmeter 3 Ph with in built selector switch suitable up to 500 Volt - 01 Set
(g) All accessories prewired with appropriate size copper strip or wire thimbles etc.
(h) All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge.
-
-
-
Supply & installation of silent CPCB approved 625 KVA TP Diesel Generating Set having diesel engine Liquid cooled, Electric start, four stroke, cold starting, TCI Aspirated, compression ignition, totally enclosed diesel engine with electronic governor , direct coupled ith 625 KVA Three Phase alternator at 1500 RPM, 0.8 lagging power factor, providing Three Phase 415Volts suitable for 50 Hz, H class insulated winding, Close-direct-coupled, Self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base-frame. The alternator shall confirm to IS: 13364, IS: 4722, BS5000, IEC: 34 and suitable for tropical condition. having fitted inside Canopy, fabricated out of 1.6 mm CRCA Sheet, cubical type, totally enclosed, Powder Coated, Control Panel and all accessories in- housed in a acoustic enclosure – sound proof canopy.
1
-
-
(A) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-
-
-
-
i) Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts.
iii) Cooling Water pump : - Centrifugal type belt driven.
iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre. Exhaust gas turbo charger type, Exhaust manifold, Silecer : Residual type, Bellows
-
-
-
iv) Fule System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governer for 1% speed /frequecy regulation. Fuel filters, Fuel hoses
v) Lub oil System :- Lubricating oil filter, Lubricating oil pump
vi) Air Intake System :- Air intake Manifold, Air cleanler dry type, vii) Governer :- Electronic Governer, viii) Starting System :- Electric Self starter with maintenace free battary including battary charging alternator.
-
-
-
(B) Batteries :- 24 VDC system Batteries of maintenece free of capacity as recommended by the manufacturer complete with copper conductor multistrnded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified of Make as per OEM.
D) Starter gear ring, Start and stop push button, Ignition key / Switch, Handling and operation : Salient features of accessories shall be as under, Radiator with blower fan, Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass. Electronic governer controlled direct fuel injection system, Fly wheel housing and fly wheel.
-
-
-
(C) Generator Monitoring Control Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display including suitable size MCCBs and multifuction meter.
xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine.
xii) Coupling arrngement : - Flexiable coupling, fly wheel to suit flexiable coupling.
-
-
-
xiii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames.
xiv) Base Frame with anti vibration pads on base frame: - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes.
xv) MS pipe line to and from the fuel tank to the DG Set.
(D) Alternator :- Standard design alternator rated at 625 KVA, net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be inposition to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.
-
-
-
i) Insualation class - 'H', ii) Temparature rise Class - 'H', iii) Excitation : Self Excited, iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% . v) Frequency regulation + 1%
F). Civil Works :- All civil works including PCC plat form as per manufacture's design also 30 cm above the ground. The depth of the foundation and PCC as recommended by the manufacturer. G) Rubber Matting of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel should be provided.
Note:- The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer.
-
-
-
(E) Accoustic Enclosure:- Manufactured by OEM suitable for 625 KVA DG Set. (i) NAL approved as per CPCB
(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.
(iii) The generating set battaries and control panel should be inside the enclosure.
(iv) Fuel tank should be out side the enclosure in the sub station building.
v) The DG Set should be provided with external Emergency stop push button.
vi) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulated platform.
viii) The enclosure should be suitably illuminated by suitable capacity of LED fittings.
xi) The noise level should be 75 db at 1m under free field conditions.
-
-
-
xii) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade.
xiii) Fuel tank as per manufacturer recommendation with inlet and outler connections and fuel level indicator.
NOTE : - (i) The Generator set prime mover will produce at least 734 BHP on 625 KVA.
(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to distrbed surfaces so as to match with the existing finishes all as specified and directed.
(iii) The quoted rate shall be deemed to be inclusive of first filling of lubricant oil. (iv) The quoted rate shall be deemed to be inclusive of 24 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer; including FOL, all arrangements are to be made by the contractor for tests.
-
-
-
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 1000 Amps complete all as specified and directed.
2
-
-
Supply and fixing LED blub full dum 7 watt with rechargeble type, retrofit all as specified and directed by Engr-in-charge
4
-
-
S&F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and including MCCB 4 pole 100 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately)
3
-
-
S&F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and including MCCB 4 pole 200 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately)
1
-
-
S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, toughned glass, 240V, IP 66 class, impact resistence IK07, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from ground with MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
8
-
-
Supply and Fixing of 40W LED High Bay light with Surface mounted device(SMD) with multiple LED with Borosilicate glass lens and acrylic, with aluminum reflector,operating Voltage between 140-270Vac, Power Factor more than 0.95%, intergal driver with 3KV surge protection differential mode/coman mode ,LED CCT 5665±355K as per ANSI BIN, Over load protection,No load Protection, Driver should be concealed under IP66 and BIS Marking (R no. for Driver), Driver Certiifcation IEC64347-2-13 IS(15885), System Lumen 4000, CRI70, Over all electrical efficency more than 90%,connecting with PVC copper cable of size 3x1 sqmm at least 2 Year on site warranty wihout any condition including taking down of old light fitting safely and removing from site complete all as specified and directed.
58
-
-
SCH 'A PART - XIV (HOT WATER SUPPLY)
Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
-
-
-
Supply and fixing of 5 star rated Water Heaters Storage type (Geysers) of Capacity 25 ltrs including grouting the nuts, bolts, washers of adequate size and all other accessories required at site for the effective functioning of the water heater complete all as specified and directed.
Note :
(i) Cost of Stop cocks deemed to be included in the quoted rate no extra payment shall be made.
(ii) PVC connections, Bib cock and GI pipe shall be measured and paid seperately.
3
-
-
SCH 'A PART - XV (CENTRAL HEATING SYSTEM)
Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
-
-
-
Electric Hot Water Generator : Supply, installation, testing and commissioning of package type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 150 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches.
3
-
-
(a) All neccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.
(b) The prices should include lifting, shifting and positioning of units at Site.
(c) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulation etc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structure etc as recommended by Manufacturer. (d) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity as per ISO or equivalent standard.
(e) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler.
-
-
-
GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 rated Axial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with EFF1 type class 'F' insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal. Pumps with performance characteristics as given below: The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps .
3
-
-
The scope also shall include following below mentioned:
(i) Electrical by pass starter for pump set as recommended by OEM.
(ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.
(iii) 3 Nos. - 150 mm dia type pressure gauges
(iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation)
(v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation). (vi) Pump capacity are as under:
(vii) Capacity and pump head not less than flow 350 USGPM , Head 35 mtr each including the triple duct valve and End Suction guide. Note:- In 02 Nos working and 01 No standby configuration.
-
-
-
EXPANSION TANK and Pressurisation Unit: Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume of Glycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder.
-
-
-
The tank connection's should be as per OEM recommendations and 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank. The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (with lates Revision) and Rated at PN 16 and ASME Stamped. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.
-
-
-
The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panel IP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U value Insulating Material and cladded with aluminium Sheet (20G).
-
-
-
(a) Expansion Tank of 1000 Lts capacity for Pocket-1
1
-
-
(b) PRESSURIZATION UNIT: for Pump Set -03 Nos (Ref. Point 4) with Control Panel and accessories for Pocket-1.
1
-
-
Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 990 litres for Pocket-1 complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make up Water tank as described above should be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G).
1
-
-
Supply, Installation, Testing and Commissioning of Ceiling Suspended Fan Coil Unit having casing with bottom return Air Plenum complete including Direct driven fan (three speed) motor, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with inbulit 2way wall with cordless remote. The Ball Valve with Strainer/ Shut off Value with Strainer at inlet and outlet of FCU should be provided. The Unit Capacity should be calculated as per BIS/ Eurovent Standard/AHRI Certification method. The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 65 Degree Celcius , OUTLET TEMP: 55 Degree Celcius and Below Mention External Static Pressure (ESP).
-
-
-
2.5 kW, ESP: 50 Pa (Reference Model No.: FWW200VC / Equivalent) (CHS Plant Room - Toilet )
1
-
-
5 kW, ESP: 50 Pa (Reference Model No.: FWW500VC/Equivalent) (Wkshp Toilet Area - 4 Qty, CHS Plant Room - Toilet- 1 Qty)
5
-
-
10 kW, ESP: 50 Pa ( Reference Model No.: FWW1000VC/Equivalent) (Staff Room: 2 Qty, SPL Shop, Tech TRG, Tech LIB, Inspection OFF, Office for Wksh- 1 Qty
7
-
-
12 kW, ESP: 100 Pa ( Reference Model No.:FUW015A/Equivalent) (Electricain - 1 Qty)
1
-
-
18 kW, ESP: 100 Pa ( Reference Model No.: FUW020A/Equivalent)
(Office for QC n Fuel Injection - 1 Qty)
2
-
-
24 kW, ESP: 100 Pa ( Reference Model No.: FUW030A/Equivalent) (Mech Section- 1 Qty)
1
-
-
30 kW, ESP: 100 Pa (Reference Model No.: FUW035A/Equivalent)
(Service Bay - 2 Qty Each Service Bay)
4
-
-
M & L for Pre - insulated MS pipe,Class 'C' having minimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge GI/AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of -50 Degree Celcius to 120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
-
-
-
Inside Building
-
-
-
100 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
50
-
-
80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
50
-
-
65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
250
-
-
50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
250
-
-
40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
450
-
-
20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
300
-
-
Buried under ground/Exposed to Ambient:
-
-
-
100 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding.
140
-
-
80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding.
50
-
-
Supply,Installation, Testing amd commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows,tees, reducers,sockets,u trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system compelete. Nominal diameters of pipe in mms as inducated below:
-
-
-
25 mm dia pipe, Insulation thickness - 19 mm
200
-
-
32 mm dia pipe, Insulation thickness - 19 mm
150
-
-
40 mm dia pipe, Insulation thickness - 19 mm
350
-
-
CABLE TRAYS
-
-
-
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required
-
-
-
150 mm width X 50 mm depth X 1.6 mm thickness
600
-
-
VALVES :
-
-
-
Supplying, fixing, testing and commissioning of following diameter valves(PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified.
Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.
-
-
-
100 mm dia Butterfly Valve
2
-
-
65 mm dia Butterfly Valve
19
-
-
Y - STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified.
-
-
-
65 mm dia Y STRAINER
3
-
-
NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified.
-
-
-
65 mm dia NRV
3
-
-
Automatic Air Purge Valves for hot water circulation header as specified and required by Engineer In Charge.
-
-
-
Automtic Air Purge Valve 20 mm dia
20
-
-
Air Separator (PN16)
-
-
-
65 mm
3
-
-
SITC of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8" dia and SS tubing, socket. Range (0-50) / (0-100) as required by Engineer In Charge.
20
-
-
SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2" size as required by Engineer In Charge.
20
-
-
Supply, installation, commissioning and testing of factory made, CPRI approved LT CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :-
1
-
-
INCOMERS
(a) Bus Bar TPN Copper extensible type main bus bars of minimum of 1200 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars of suitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 50kA .
(b) ACB 800 Amps, 415 Volt, 50 KA, 4 Pole, thermal magnetic release - 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers) Make: Legrand/Schenider/Simens
-
-
-
OUTGOINGS
(c) 5 Nos- 400A 10 KA TPN MCCB with Microprocessor release (3# Hot Water Generator) (d) MCB 5/6 Amp, 10KA, TPN - 02 Nos Pressurization PUMPs (e) MCB 50 Amp, 10KA, TPN - 03 Nos for Pumps
(f) MCB 5/6 Amp, 10KA, SPN,- 21 No for Bldg load/FCU. Makes of MCBs: Legrand/Schenider/Simens
(g) LED Phase indication lamps (01 Set) with 2Amp back up MCB, Breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set
-
-
-
(h) Digital Ammeter with in built ASS, metering C.T.s "CAST RESIN" type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.
(j) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge. Note : Contractor will submit the drawing of panel to GE before execution for approval.
-
-
-
Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed Copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)
-
-
-
3.5 Core x 250 sq.mm. (Electric Hot Water Generator)
50
-
-
4 Core x 10 sq.mm. (Pump)
50
-
-
4 Core x 6 sq.mm (Pressurization Unit)
600
-
-
2 Single core x 2.5 sq.mm. (FCU)
600
-
-
4 Core x 4 sq.mm (Boiler Pump)
600
-
-
Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge.
6
-
-
Supply and fixing rubber matting conforming to IS-15652-2006 complete as required. of size 2m * 1m * 25 mm complete all as specified & directed by Engr-in-charge.
3
-
-
Supplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels for CHS complete all as directed.
NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 55:45 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe line Storage Tank.
1
-
-
GENERAL NOTES:
-
-
-
1. The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of :
(a) All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings.
(b) Wastage on materials and labour.
(c) Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognize principles.
-
-
-
(d) Liabilities, obligations and risks arising out of Conditions of Contract.
(e) The unit rate for all equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required. 2. The contractor shall perform Nitrogen test and vacuum test on refrigerant piping. Start and stop timing & pressure maintained shall be checked and the readings recorded shall be counter signed by consultant / client’s representative.
-
-
-
3. Cable glands shall be compression type, heavy-duty chromium plated. 4. All cable termination to have lugs/ thimbles. 5. INSTRUCTION / MAINTENANCE MANUAL
-
-
-
The Contractor shall prepare and produce instruction, operation and maintenance manuals in English for the use, operation and the maintenance of the supplied equipment and installations and submit to the Client / Consultant in (3) copies at the time of handing over. The manual shall generally consist of the following:
(i) Description of the project.
(ii) Operating instructions.
(iii)Maintenance instructions including procedures for preventive maintenance.
(iv) Manufacturers catalogues.
(v) Trouble shooting charts.
(vi) Schematic & control wiring diagrams.
-
-
-
(vii) Commissioning Certificate.
(viii) Also for BMS System, Training,Opeartion, Installation manual and Trouble shooting manual and Training should be imparted to the field person.
(ix) All neccassary license should be provided for the BMS free of cost. 6. For Make List If any make stated below does not comply with the technical specifications and or IS Standards then such a make shall not be used in the work. 7.MAINTENANCE OF PLANT AND TRAINING OF PERSONNEL
The Cont ractor shall arrange to provide, at no extra cost, necessary personnel and material to carry out all routine maintenance of the CHS equipment as required regularly.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%