Military Engineer Services Tender
... More
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 13,980Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_647487_1Bid Award Id
ViewTender No
GEAF/T-15/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for in repair / replacment electronic LED driver for LED light fittings, capacity 45 Watt, 50Hz, complete all as specified and directed by Engineer-In-Charge.
Make: Havells, Wipro, Phillips,crompton,bajaj
25
-
-
... More
Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge.
32.4
-
-
... More
Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a soft/loose soil complete all as specified and directed by Enginer-in-Charge.
17.84
-
-
... More
Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
14.56
-
-
... More
M&L for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and directed.
Note:-Excavation and earth work to be measured and paid for separately
1067
-
-
... More
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge.
Note: Punned thickness of sand shall be measured.
12.96
-
-
... More
S&F LT Junction box for street lights,Sheet Moulding Compound ( SMC),hinged door type and locking arrangement, off white colour of size 155X155X100 mm (internal dimensions) comprising 2 Nos aluminium bus bar of adequate capacity including suitable Size MS clamps,including taking down old unserviceable junction box complete all as specified and as directed by engineer-in-charge.
20
-
-
... More
S&F in repair including taking out old LT Junction box for street lights,Sheet Moulding Compound ( SMC),hinged door type and locking arrangement, off white colour of size 240x130x95 mm (internal dimensions) comprising 4 Nos aluminium bus bar of 200 Amps complete on 6 Amp MCB SP adequate capacity including suitable Size MS clamps,including taking down old unserviceable junction box complete all as specified and as directed by engineer-in-charge.
20
-
-
... More
S&F Aviation obstruction light in die-cast aluminium alloy housing,built in 75V step up transformer,1x75VA neon spiral lamp,heat resistant,clear thick glass dome complete with all acessories as specified and directed by engr-in-charge. Make: bajaj/crompton/havells or equivalent.
10
-
-
... More
M&L for in repair / replacment XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 2-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
50
-
-
... More
All as per Srl Item No 12 above but of size cross-sectional area 16.0 Sqmm, 4 -core.
50
-
-
... More
All as per Srl Item No 12 above but of size cross-sectional area 185.0 Sqmm, 3.5 -core.
50
-
-
... More
All as per Srl Item No 12 above but of size cross-sectional area 300.0 Sqmm, 3.5 -core.
50
-
-
... More
Replacement of old unserviceable/damaged street light bracket made out of GI pipe 40 mm bore light grade 1.5 m long bend to shape required fixed to pole / wall with MS clamps made out of 40x5 mm, 50 cm long incl nuts bolts of size 80x12 mm complete all as specified and directed.
5
-
-
... More
S& F in weather proof flat twin core cable aluminium conductor cable 2.50 sqmm complete all as specified and directed.
100
-
-
... More
M&L for GI pipe 20mm dia light grade for passing through wire between terminal box to street light with GI clamp complete all as specified and directed.
100
-
-
... More
supply and fixing SPN 32 amp rating 240V,10KA 'C' curve MCB 32 amp current carring capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
50
-
-
... More
M&L for in repair / replacment fabrication and install street light terminal box outdoor canopy type size 40cm Height x 30 cm width x 12 cm thick size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut, bolt, & 8 Nos aluminium cable socket suitable for upto 185 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25x25mm 40 cm long as per sample incl taking down.complete all as specified.
5
-
-
... More
M&L in repair Earthing complete with copper plate electrode 600x600x3.15mm thick electrode burried directly in ground not less than 3.0 mtr deep below normal ground level with top edge of earth plate not less than 2.5 mtr below normal ground level connected to and including and 20x3 mm copper strip as earth lead by means of bolt ,nuts, check nuts, and washers of stainless steel and duly welded incl PCC pit in PCC 1:2:4 type B-I angle iron 40x40x3mm frame, pit in PCC 1:2:4 type B-I cover 40mm reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20mm bore with funnel and wire mashand medium grade GI protection pipe 40mm bore and earth wire up all as shown in electrical plate No 3 of MES SSR- Part-I all as directed and specified by Engineer-in-charge. Note : Excavation work should be done by manpower only. ( Earth test should be done by contractor and if required result is not found entire earting should be done by contractor again ) .
2
-
-
... More
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
1
-
-
... More
M&L for in repair / replacment Change over switch, rating 100 Amps, four poles, 415 Volts, AC, 50 Hz, on load, conforms to IS:13947 (Part-3); IEC:60947-2, side handle, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Make: Havells cat part No- IHBFFE0100 or equivalent in Indo-Asian/ L&T/ Legrand/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
1
-
-
... More
M&L for in repair / replacment Change over switch, rating 200 Amps, four poles, 415 Volts, AC, 50 Hz, off load, conforms to IS:13947 (Part-3); IEC:60947-2, side handle, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Make: Havells cat part No- IHBFFE0200 or equivalent in Indo-Asian/ L&T/ Legrand/ Standard/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
1
-
-
... More
M&L for in repair / replacment Mild steel bands, straps, including bolts, if required: clamps for house brackets for mounting street/ security light fittings; ties; hooks for hanging fans;and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and as directed by Engineer-In-Charge.
5
-
-
... More
Attanding day to day complaints for maintenance and repair of street/ perimeter security light fittings of any type and any specifications or any accessories related to security light fittings of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge.
Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate.
(ii) Supply of spare parts of light fittings shall be measured and paid separately.
25
-
-
... More
Note: The work under subject BoQ (item No. 1 to 27 ) is meant for maint of senstive security and street light in AF Stn Thoise under GE(AF ) Thoise. The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of Security and street light in the AF station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor's payment for each complaint so notified.
-
-
-