Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 86,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673494_1Bid Award Id
ViewTender No
GE/KHU-62/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for stone dust sand cushioning to UG cable laid in trenches all as specified and directed.
37.65
-
-
Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x180mm x 40mm placed perpendicular of the cable complete.
389
-
-
Supplying and laying unreinforced precast concrete cable cover, class LV, type 1 flat of size 250mm x150mm x 40mm placed perpendicular of the cable complete.
2793.67
-
-
Supply and fix in repair GI Pipe Light grade with all connected accessories of sizes 100 mm dia completed as directed for cable protection
36
-
-
Cutting of existing road not exc 1.5 mtr in depth and not exceeding 0.45 mtr wide including providing black top sub base and WBM, well ramming in layers with watering after laying of GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.
30
-
-
Taking out the UG XLPE insulated armoured /unarmoured PVC sheathed laid in trenches/ passing through GI tubing /on pole /on wall of any size and type complete all as specified and directed.
530
-
-
Supply laying & testing in repair cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 120 sq mm.
300
-
-
Supply and laying,jointing & testing in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volt grade laid in trenches,ducts,drawn through pipes across the road/path/along poles/floors/equipment etc of size 300 sq mm 3.5 core.
60
-
-
All as per item srl No. 11 here-in-before but of size 150 sqmm 3.5 core
100
-
-
All as per item srl No. 11 here-in-before but of size 120 sqmm 3.5 core
100
-
-
All as per item srl No. 11 here-in-before but of size 95 sqmm 3.5 core
100
-
-
All as per item srl No. 11 here-in-before but of size 70 sqmm 3.5 core
130
-
-
All as per item srl No. 11 here-in-before but of size 35 sqmm 3.5 core
50
-
-
All as per item srl No. 11 here-in-before but of size 25 sqmm 4.0 core
200
-
-
Supply installing, testing and commissioning of LT Panel outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Aluminium bas bar of capacity 400 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- LT panel shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm) . The panel shall have 2 nos compartment for 02 nos incommer and 02 nos outgoing section .Panels shall be of CPRI approved .
Note:- Drg of panel shall got approved before execution at site.
1
-
-
INCOMMER BAY 1
Onload change over 415V, 50 Hz , 250 Amps , capacity ,4 pole -01 No
Incoming MCCB, 415V, 4 pole, 250 Amps, 36 KA, Ics =100% Icu
Indicator Lamp-01 Set (Set of three)
Voltmeter 0-500 Volt , 415V , 50 Hz ,with selector switches -01 set
Ammeter 0- 500 Amps with CTs, 415V 50 Hz with selector switches -01 set
INCOMMER BAY 2
Onload change over 415V, 50 Hz , 250 Amps capacity , 4 pole -01 No MCCB, 415V, 4 pole, 200 Amps, 36 KA, Ics =100% Icu
Indicator Lamp-01 Set (Set of three)
Voltmeter 0-500 Volt , 415V , 50 Hz ,with selector switches -01 set
Ammeter 0- 500 Amps with CTs, 415V 50 Hz with selector switches -01 set
OUTGOING BAY 1
MCCB, 415V, 4 pole, 250 Amps, 36 KA -01 No
MCCB 4 pole 125 amp, 415V, 36 KA, 4 pole , 02 Nos MCCB 4 pole 63 amp, 415V, 36 KA, 4 pole , 03 Nos MCB SPN 20 Amps , 230V, 50 Hz - 02 Nos
OUTGOING BAY 2 MCCB, 415V, 4 pole, 250 Amps, 36 KA -01 No MCCB 4 pole 125 amp, 415V, 36 KA, 4 pole , 01 Nos MCCB 4 pole 63 amp, 415V, 36 KA, 4 pole , 01 Nos
-
-
-
Supply installing, testing and commissioning of LT Panel outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Aluminium bas bar of capacity 400 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- LT panel shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm) . The panels shall be of CPRI approved Note:- Drg of panel shall got approved before execution at site.
1
-
-
INCOMMER Onload change over 415V, 50 Hz , 315 Amps , capacity ,4 pole -01 No
Incoming MCCB, 415V, 4 pole, 315 Amps, 36 KA, Ics =100% Icu
Indicator Lamp-01 Set (Set of three)
Voltmeter 0-500 Volt , 415V , 50 Hz ,with selector switches -01 set
Ammeter 0- 500 Amps with CTs, 415V 50 Hz with selector switches -01 set
OUTGOING
MCCB, 415V, 4 pole, 200 Amps, 36 KA -01 No MCCB 4 pole 125 amp, 415V, 36 KA, 4 pole , 02 Nos MCCB 4 pole 63 amp, 415V, 36 KA, 4 pole , 04 Nos MCB SPN 40 Amps , 230V, 50 Hz - 01 Nos
-
-
-
Supply installing, testing and commissioning of Bus bar junction box panel outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Aluminium bas bar of capacity 400 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- Bus bar junction box shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm) . Note:- Drg of bus bar junction box panel shall got approved before execution at site. INCOMMER/OUT GOING
Incoming MCCB, 415V, 4 pole, 250 Amps, 36 KA, Ics =100% Icu -01 nos
Indicator Lamp-01 Set (Set of three)
2
-
-
S & F in replacement of existing UNSV HPSV/LED fitting with LED street light fittings 60 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
60
-
-
Checking of street light fittings any type on pole to find out defect /taking out UNSV parts such as driver and repairing by changing the defective parts including minor repairs to cable connection all as speciifed and directed.Note: Spares of light fitting shall not be measured separatly,ii) The T & P Vehicles and necessary ladders etc will be arrange by the contractor and the cost deemed to be inlcuded in the quoted rates.
120
-
-
M&L for replacing LED driver for 1x45 watts security light 230V, 50 Hz of make Bajaj/Havells/crompton
50
-
-
M&L for replacing SPD for 1x45 watts security light 230V, 50 Hz of make Bajaj/Havells/crompton
50
-
-
S&F in repairs cable end joint 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable indoor type complete all as specified and directed.
4
-
-
S&F in repairs cable end joint 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable outdoor type complete all as specified and directed.
3
-
-
S&F in repairs cable straight through joint 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work all as specified and directed.
4
-
-
M&L for relaying of HT cable after rectification of the fault size 120 to 185 sq mm complete all as directed
30
-
-
M&L for services for cable fault location for 11 KV, 3 core XLPE Cable 95 sqmm to 185 sqmm with the help of HT cable fault detector machine complete all as directed
5
-
-
M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achieve dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level all as directed.
Note: (a) Oil topping up shall be measured and paid separately.
(b) Filtration shall be done at site and on line. (c) BDV test shall be carried out before the filtration and after the filtration & results recorded in triplicate duly signed by the contractor, MES rep. and Engr-in-charge (d) Dielectric strength of the oil shall not be less than 50 KV after filtration & the rate quoted for the items shall be deemed to include the filtration till the desired dielectric strength is achieved.
2500
-
-
Supply and fill new transformer oil topping up / change complete superior quality having di - electric strength not less than 60 KV and ISI marked of approved make.Note: Items rates deemed to include for (a) The transformer oil shall be ISI marked, and brought at site in sealed container only.
(b) Collection of samples before and after topping up/changing including testing for dielectric strength.
300
-
-
Disconnecting the transformer any type situated at various locations 11/ 0.433 KV of any make and transporting to workshop for repairs/ rewinding. Dismantling the transformer and accessories, draining out insulating oil, taking out the core assembly, defective winding, cleaning the transformer complete internally and externally providing new insulation, sleeves for outlet connections, ovening the complete core assembly, reassembling, including dehydration and filtration of transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for following capacities of transformer :-
-
-
-
100-350 KVA
1
-
-
500/750 KVA.
Notes (i) Copper winding wire/strip will be measured and paid separately.
(ii) Transformer oil for topping up will be measured and paid separately.
(iii) Transportation of transformer for repair and re-installation is deemed to include in quoted rates.
1
-
-
M&L for taking out of burnt HT coil winding and replacement of the same with new copper wire coil of same gauge and turns including necessary insulation materials like impregnated paper or super enamelled of transformers of capacity 250/500 KVA all as directed by Engr - in - Charge
180
-
-
M&L for taking out of burnt LT coil winding and replacement of the same with copper strips of same gauge and turns including necessary insulation materials of transformers of capacity 250/500 KVA all as directed by Engr - in - Charge
160
-
-
Disconnecting the transformer any type from HT/ LT system and opening carefully for rectifying the leakage by replacing the unserviceable spare parts of capacity 100 to 500 KVA transformer and complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the HT/ LT system all as specified and directedNote :- Defective parts replaced will be measured and paid separately
2
-
-
Supply only in repair of LT bushings with brass studs.
3
-
-
Supply only in repair of top cover gasket set.
3
-
-
Supply only in repair of radiator flanged gasket 6 mm thick.
6
-
-
Supply only in repair of oil level indicator gasket set.
3
-
-
Supply only in repair of HT bushing with brass studs 11 KV.
3
-
-
Supply and fix in replacement of breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer.
4
-
-
S&F in repair lightning arrestor non linear resister type (Surge) suitable for 11000 volt grade conforming to IS-3070 Part-I with discharge capacity 65 kilo Amps including stranded coloured sleeved jumper connection with PG clamps mounted on steel mounting fabrication of MS clamps, bolts, nuts, washers etc all as specified and directed.
1
-
-
M & L for replacement of earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/piope or fixed to poles or any other indicated situation for loop earting etc as required 32x6 mm galvanised iron strip .
25
-
-
M&L for removing HT/LT over head conductor from the insulator where ever required and restretching the same without any kink/bend upto permissible sag,binding it on insulator by means of binding wire and testing the HT overhead line after completion as directed.(Note: Three/four runs of HT/LT overhead conductor for three phases and neutral shall be measured and paid as one length.)
2700
-
-
Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping padestal to poles including provision of necessary form work finishing the exposed surface even and smooth complete all as specified.
1.2
-
-
Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 complete all as specified.
3.2
-
-
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash to the portion of PCC muffs above ground level complete all as specified.
1.5
-
-
S&F in repair Aluminium conductor, steel reinforced, of size 6/211 to 6/3010 mm (Squirrel to Ferret) straining properly on insulators with and including aluminium tape/winding wire, clamps & jumpers etc. complete all as specified.
Note : 3% for sag shall be added in measurement .
1
-
-
S&F in repair Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending (cold or hot), drilling holes for bolts, bent to any shape or size as directed and inclusive of one primer coat of red oxide, one under coat of zinc oxide and one finishing coat of aluminium paint complete all as specified.
1.2
-
-
S&F in repair pin type porcelain vitreous white,brown insulator 150 mm height and 150 mm dia for working pressure 11000 volts complete all as specified.
50
-
-
M&L for disc type insulator,porcelain,vitreous 145 mm high and 255 mm dia ball and socket type,white.brown or green two in series assembly for tension clamps for conductors for working pressure 11000 volts grade,including taking out existing unserviceable insulator of any type/description etc complete all as specified and directed
5
-
-
Supply and fix in replacing LT Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle, two gavanised iron washers and one galvanised iron nut, 50mm
height, 65mm dia for 550 volts complete all as specified and directed.
30
-
-
Supply and fix in replacing Shackle Type, Porcelain, vitreous, white, brown or green insulator working voltage 1100 volt, height 75 mm and dia 90mm including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of size
30
-
-
S&F in repair stay assembly complete with accessories as shown in electrical plate No 1 and diameter of stay rod 16 mm (loop type insulator,stay clamps,excavation and concrete measured separately).
1
-
-
Taking down defective unserviceable GOD from pole and supply and fix gang operated air break switches incl 12 insulators mounted on MS Channel with operating mechanism worked from ground level suitable 11000 volts, 200 Amps including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements.
4
-
-
Material and labour for replacement of Digital type 3 phase voltmeter of capcity 0-500 V with selector switch complete all as specified and directed.
4
-
-
Material and labour for replacement of Digital type 3 phase ammeter of capcity 0-300 A with selector switch and CTs complete all as specified and directed.
4
-
-
Material and labour for replacement of Neon indicator lamp RYB set of three complete all as specified and directed.
6
-
-
M & L for changing the locks and refixing the doors of LT panels by welding and painting the outer surface of panel complete all as specified and directed
9
-
-
Disconnecting from circuit/bus bar LT and taking out cables for extension of loop/passing through pipe reconnection with circuit and tightening of connections complete all as specified and directed
20
-
-
S&F in replacement of existing unserviceable changeover any size & capacity with changeover 4 pole 630 Amps front handle operated along with SS enclosure including minor additional/alternation as required at site for fixing and connecting up of changeover all as directed by Engr-in-Charge.
4
-
-
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 400 Amps 36KA Thermal magnetic and Microprocessor release with thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
4
-
-
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 250 Amps 36KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge
8
-
-
S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 160 Amps 36 KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
10
-
-
S & F in replacement MCCB VTPN DB Vertical 04 ways,double door ,powder coated DB and provision for MCCB /MCBs including necessary earth bar and neutral link 200 Amp,and complete with provision of MCB (out going) with adjustable release complete fixed as in repair all as specified.
5
-
-
S&F in replacement of existing unserviceable changeover any size & capacity with changeover 4 pole 100 Amps with side handle operated including minor additional/alternation as required at site for fixing and connecting up of changeover all as directed by Engr-in-Charge.
4
-
-
S&F in repair danger notice plate of 1.6 mm thick mild steel sheet,vitreous enamelled white with letters,figures and conventional skul and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size,for HT,25x20 cm in size.
10
-
-
Supply and fixing G I tubing 40 mm dia light grade galvanised with all fittting and fixed fix on wall ceiling or laid in floors complete all as specified and direceted at site .
21
-
-
M&L for replacing 3 core copper flexible cable 2.5 sqmm PVC sheathed FRLS complete all as specified and directed .
300
-
-
Supply and fix in replace unsv PVC heavy duty conduit 25 mm size for fixing on strret light pole from junction box to security light fitting with proper MS clamps for supporting with pole including all fixing accessories such as nuts , bolts and wshers complete all as specified and directed .
300
-
-
S&F in repairs cable straight through joint 70 to 150 Sqmm 3.5 core XLPE 1.1KV LT Cable heat shrinkable complete including necessary excavation and earth work all as specified and directed.
10
-
-
S&F in repairs cable end temination out door type 70 to 150 Sqmm 3.5 core XLPE 1.1KV LT Cable heat shrinkable complete including necessary excavation and earth work all as specified and directed.
10
-
-
M&L for replacing Moulded case circuit breaker (MCCB) 4 pole 125A , 50 Hz 16KA breaking capacity complete all as specified and directed.
15
-
-
All as per above but of capacity 100 Amps complete all as specified and directed.
12
-
-
All as per above but of capacity 63 Amps complete all as specified and directed.
8
-
-
M&L for painting of LT/security light steel tubular pole upto 9 mtr length incl MS clamp , bracket, cross arms and metallic junction boxe with two coat of alumnium paint after preparation of old painted surface and applying metallic primer , providing 03 nos alternative strip of 30 cm wide with black and yellow super quality enamel paint above embedded level and writing pole nos with 02 inch wide letter complete all as specified and directed
325
-
-
M&L for painting of steel tubular pole upto 11 mtr length incl MS clamp , bracket, cross arms with two coat of alumnium paint after preparation of old painted surface and applying metallic primer , providing 03 nos alternative strip of 30 cm wide with black and yellow super quality enamel paint above embedded level and writing pole nos with 02 inch wide letter complete all as specified and directed.
Note for item No : Necessary electric shutt down will be taken from the Dpt before commencing the work .
300
-
-
M&L in replacing LT line seperator made of PVC 4 line complete with screws, bolts , nuts all as specified and direted.
382
-
-
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
8
-
-
Deduct Credit for Demolished/Dismantled material Rs (-) 65,545.00 (Minus) as listed in Schedule 'A' Sec-II (Credit Schedule)