Military Engineer Services Tender

Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date22 Nov 2024
Closing Date13 Dec 2024
Tender Amount₹ 4,00,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation over areas n exc 1.50m deep and getting out in any type of soil, complete all as specified and directed by the Engr-in-Charge.

50.34

-

-

... More
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25mm thick, complete all as specified and as directed by Engineer-in-charge.

41.84

-

-

... More
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc non exc 10 Sqm on plan and nexc 1.5 m in depth and getting out for laying of cable / pole etc in hard/dense soil, complete all as specified and directed by Engr-in-Charge.

65

-

-

... More
Excavation in trenches not exc 1.5 m wide and exc 1.5 m and not exc 3.0 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc non exc 10 Sqm on plan and nexc 1.5 m in depth and getting out for laying of cable / pole etc in hard/dense soil, complete all as specified and directed by Engr-in-Charge.

3.5

-

-

... More
Excavation in trenches in any type of soil n.exc 1.5m wide and not exc 1.5m in depth for foundations or for shafts, wells, cespits, manholes pier holes etc. and getting out in any type of soil, complete all as specified and directed by Engr-in-Charge.

13.5

-

-

... More
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in hard dense soil, returing, filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm thick, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Surface excavation n exc. (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in hard/ dense soil complete all as specified and directed, complete all as specified and directed by Engr-in-Charge.

165

-

-

... More
Excavation over area n exc 1.5m deep and getting out in hard/ dense soil, complete all as specified and directed by Engr-in-Charge.

99

-

-

... More
Under Ground Sump

-

-

-

... More
PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete etc, complete all as specified and as directed by Engineer-in-charge.

5.1

-

-

... More
Supply only integral water proofing compound, complete all as specified and as directed by Engineer-in-charge.

72

-

-

... More
Form work to faces of walls, retaining walls, parapets, water tank side walls and similar works of rough finished flat surfaces, complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Form work to edges of concrete flat, roof slabs all exc 20cm Wide/ thick shelves etc for rough finished surfaces, complete all as specified and directed by the Engr-in-Charge.

14.22

-

-

... More
TMT bars 10 mm dia and over cut to length bent to shape required incl cranking bending spirally for hooping etc and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed by the Engr-in-Charge.

400

-

-

... More
TMT bars 06 mm dia and over upto incl 10mm cut to length bent to shape required incl cranking bending spirally for hooping etc and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed by the Engr-in-Charge.

500

-

-

... More
RCC M-30 (Design Mix) using 20mm graded crushed stone aggregate as in foundation, rafts, footings, base slab or water tanks and similar works , complete all as specified and directed by the Engr-in-Charge.

7

-

-

... More
RCC M-30 (Design Mix) using 20mm graded stone aggregate as in walls, side walls of water tanks and similar works, complete all as specified and directed by the Engr-in-Charge.

8

-

-

... More
RCC M-30 (Design Mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies etc, complete all as specified and directed by the Engr-in-Charge.

5

-

-

... More
Providing Precast RCC cover slabs (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in manholes cover, leach pit and similar items set in CM 1:4, complete all as specified and directed by the Engr-in-Charge.

0.01

-

-

... More
Rendering 15mm thick cement plaster in CM 1:4 on fair faces of concrete or brick work and finished even and smooth without using extra cement, complete all as specified and directed by the Engr-in-Charge.

23

-

-

... More
Preparation of newly plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed by the Engr-in-Charge.

6

-

-

... More
Internal Electric Supply for Existing Building

-

-

-

... More
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings , bulk head fittings, tube lights fittings and regulators etc for reuse the same at site, complete all as specified and directed by the Engr-in-Charge.

404

-

-

... More
Fixing only LED tube light fittings 20 watt with ceiling rose as retrieved from ser item No - 3.01 above and connecting up with existing three core flexible copper conductor cable, complete all as specified and directed by the Engr-in-Charge.

90

-

-

... More
Fixing only lamp holder as retrived from ser item No 3.01 above and connecting electrically, complete all as specified and directed by the Engr-in-Charge.

4

-

-

... More
Fixing only 6 Amp switch piano as retrived from ser item No 3.01 above and connecting electrically, complete all as specified and directed by the Engr-in-Charge.

90

-

-

... More
Fixing only 16 Amp switch socket independent board and switch socket combination as retrived from ser item No 3.01 above and connecting electrically, complete all as specified and directed by the Engr-in-Charge.

40

-

-

... More
Fixing only 6 Amp switch socket indepndent boad and switch socket combination as retrived from ser item No 3.01 above and connecting electrically, complete all as specified and directed by Engineer-in-Charge.

95

-

-

... More
Fixing only ceiling rose as retrived from ser item No 1 above and connecting electrically, complete all as specified and directed by Engineer-in-Charge.

85

-

-

... More
Point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multistranded conductor, 1100 V grade of size 1.5 sqmm including necessary termination board 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earthing and connected to common earthing with PVC heavy duty casing caping/PVC conduit ISI marked as rquired at site along with all accessories and making good the disturbed surfaces of wall/ ceiling etc for one switch socket combination Point on independent board, complete all as specified and directed by the Engr-in-Charge.

50

-

-

... More
Supply and fix switch socket combination multi purpose 5 pin, 5 amp, complete all as specified and directed by the Engr-in-Charge.

50

-

-

... More
Insulation of Annexe Building Wall and Ceiling

-

-

-

... More
12mm thick prelaminated particle board interior grade prelamination one side and other side balancing white lamination fixed with nails to timber frame work as in wall, complete all as specified and directed by the Engr-in-Charge.

2800

-

-

... More
09mm thick prelaminated particle board interior grade prelamination one side and other side balancing white lamination fixed nails to timber frame work as in ceiling, complete all as specified and directed by the Engr-in-Charge.

600

-

-

... More
2nd class soft wood plain fillets square rectanugular/ triangular in section clean sawn secured with nails area exc. 13 & n.exc 25 sqcm, complete all as specified and directed by the Engr-in-Charge.

7600

-

-

... More
2nd class soft wood plain fillets square rectanugular / triangular in section wrought with nails sectional area exc. 6 & n.exc 13 sqcm, complete all as specified and directed by the Engr-in-Charge.

1650

-

-

... More
2nd class soft wood plain fillets square rectanugular/ triangular in section wrought with nails sectional area not exc. 3 sqcm as in beading, complete all as specified and directed by the Engr-in-Charge.

2000

-

-

... More
Bonded mineral wood blankets slab made from glass, density 24kg/cum and fixed as per manufacturer's instruction 40mm thick covered, complete all as specified and directed by the Engr-in-Charge.

3400

-

-

... More
4.8mm thick, sheet glass ordinary quality and glazing with wooden beading in square n exc 0.50 sqm in each pane, complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long, complete all as specified and directed by Engineer-in-Charge.

900

-

-

... More
Silicon Sealants laying on Gypsum board in ceiling, etc complete all as specified.

900

-

-

... More
Polythene film, black, 50 micron laid in ceiling, complete all as specified and directed.

1800

-

-

... More
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed by Engr-in-Charge.

300

-

-

... More
Hot Water Supply System

-

-

-

... More
Hot Water Tank with inbuilt Heater: Supply of Horizontal / Vertical Type Storage Tank of capacity 6000 Litre, Construction - Made from Stainless Steel Sheet- SS 316, Sheet Thickness- 8mm thick Shell & 10mm thick Dish end Connection - Inlet / Outlet / Drain / Vent, Heater Rating - 30 KW x 5 Nos , 150 KW. Insulation - 100mm thick Puf Inulation (40 Kg/Sqcm density), Cladding - 24 gauge thick Aluminium Sheet,Test Pressure – 100 P.S.I G,Electrical Panel – Step Controller, Main incomer S.F.U, Outgoing Contactor, M.C.B, Master Thermostat for high temperature cut-out, Low level controller with sensor, Pressure Gauges with Ball Valves, Pressure Relief Valve, Auto vent Factory wired complete. Flameproof Heat tracing cable of 45 Watt/meter to operate at 230V single phase AC with total capcity of 8 KW, with junction boxes will be installed at bottom Dish end and on cylindrical portion with the help of self adhesive aluminium film. Panel should also include the OEM recommended MCB for Water Circulation pumps, complete all as specified and directed by Engr-in-Charge. Note :- (i) All neccassary accessories required for the proper functioning of Hot Water Generator are included in price. (ii) The prices should include lifting, shifting and positioning of units at Site. (iii) Hot Water Tank installation to be done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator, Insulation, all accessories required for proper fucntioning, etc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Structure, Mechanical Structure etc as recommended by Manufacturer. Make of Boiler: Rapid Cool/Rapid Therm

2

-

-

... More
Hot Water CENTRIFUGAL PUMPS: Supply, Erection, testing and commissioning of Flow: 20 USGPM, Head: 10 meter (Circuit: Hot Water Generator : Storage Tank) Horizontal/Vertical in line axial Split Coupled PN 16 centrifugal pumps complete with CED coating, externally flushed outside type balanced Mechanical Seal and non overloading motor, as per specifications and drawings.suitable HP, TEFC permanent magnet motor with Efficiency IE3, class ‘F’ insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply for each pump. The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -45 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps. Triple Duty Valve and Suction Guides to be provided by the pump manufacturer for the unit responsibility. Each pump shall comprise of following as required as per specifications. Note : (i) Electrical starter for pump set should be as OEM Recommendation. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump. (iii) 3 Nos. - 150 mm dia type pressure gauges (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation). (vi) Capacity and pump head should be not less than as mentioned above head each including the triple duct valve and End Suction guide. Make of Pump : Armstrong (Reference Model:4300 5012-007.5) / Xylem /Grundfoss/Wilo

2

-

-

... More
All as per para 5.02 above but flow : 10 USGPM 35 meter head Hot water tank for Ring main, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply, installation, testing and commissioning of Heater Rating 10 KW with Ceramic coating to be installed in under ground storage tank, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and Fix highly accurate temprature / humidity sensor thermostat controller on / off indoor to control CHS unit to measure the temp inside the buildings from the minus 35 degree celsius to plus 35 degreee celsius range with robust design and recording last 10 readings of temp and humidity, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Pre - insulated PPR pipe as IS:4984 having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 gauge GI cladding complete suitable for in side building above ground / underground / wall mounted of following sizes. Note :- The pipes should be insulated with closed cell puf of density 36 ± 2 Kg/Cum of under mentioned thickness. The Pipe should be workable in the temp. range of -50 Degree Celcius to 100 Degree Celcius. The All Accesories, U trap, Joints, Elbow and Joining of Pipes with OEM recommendation should be included in the rate of pipes.

-

-

-

... More
(a) 50 mm with 69 mm PUF thicknes and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

200

-

-

... More
(b) 50 mm with 69 mm PUF thicknes and 26 Gauge HDPE Cladding, complete all as specified and directed by Engr-in-Charge.

200

-

-

... More
(c) 40 mm with 65 mm PUF thicknes and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
(d) 25 mm with 60 mm PUF thicknes and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supplying and installing cable tray of size 150 mm width X 50 mm depth X 1.6 mm thickness of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling / Ground / wall with M.S. suspenders including bolts and nuts, painting suspenders etc. as required, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supplying, fixing, testing and commissioning of 80 mm dia Butterfly Valve valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts and Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section/HPDE Caldding for Buried, complete all as specified and directed by Engr-in-Charge. Note : Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet and O ring, Complete with fittings, Nuts, Bolts & Gaskets

8

-

-

... More
Y - STRAINER 80 mm dia (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
NON - RETURN VALVE 80 mm dia (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Automatic Air Purge Valves for hot water circulation header as specified and directed by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
SITC of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-100 C. Brass oil filled thermowell of 1/2" size as required by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply and fixing rubber matting conforming to IS-15652-2006 complete as required. of size 2m x 1m x 25 mm, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Internal Water Supply For Hot Water Supply

-

-

-

... More
15mm bore chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete, complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Stop valves, chromium plated cast coper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of for brass union, complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
PVC connection pipe 15mm with PTMT nuts of length 600 mm, complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
16mm outer dia, 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 and SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
20mm outer dia, 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 and SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply incl all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Central Heating System

-

-

-

... More
Electric Hot Water Generator : - Supply, installation, testing and commissioning of package type electric Hot Water generator constructed out of MS sheet having easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 300 KW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, as recommended by OEM. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual / auto rotary switches control and compatability, complete all as specified and directed by Engr-in-Charge. Note :- (a) All neccassary accessories required for the proper fucntioning of Hot Water Genearator shall be included in price. (b) The prices should include lifting, shifting and positioning of units at Site. (c) Hot Water Genearator installation to be done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulation,all accessories required for proper fucntioning, etc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation shall be included in ODU price which includes the Civil Structure, Mechanical Structure etc as recommended by Manufacturer.

3

-

-

... More
GLYCOL CIRCULATION CENTRIFUGAL PUMPS :- Supply, Erection, testing and commissioning of Vertical in line axial Split Coupled PN 16 centrifugal pumps Flow : 125 USGPM, Head: 35 meter complete with CED coating, externally flushed outside type balanced Mechanical Seal and non overloading motor, as per specifications and drawings of suitable HP, TEFC permanent magnet motor with Efficiency IE5, class ‘F’ insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply for each pump. Pump should be provided with motor mounted IP55 integrated VFD for sensorless/wireless control( 2 nos of wireless DPTs should be considered for wireless control across the load). Pump mounted VFD must display dynamic frequency, amps, volts, real time flow and head of operating pump.The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -45 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . Suction Guides to be provided by the pump manufacturer for the unit responsibility. Fluid : Glycol 55%, Water 45%. Each pump shall comprise of following as required as per specifications :- (i) Electrical starter for pump set should be as OEM Recommendation. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump. (iii) 150 mm dial type pressure gauges - 3 Nos. (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation flow). (vi) Capacity and pump head should be not less than as mentioned above head each including the triple duct valve and End Suction guide. Make of Pump : Armstrong(Reference Model:4300 5012-007.5) / Xylem /Grundfoss/Wilo

3

-

-

... More
EXPANSION TANK AND PRESSURIZATION UNIT :- Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK of capacity Expansion Tank of 500 Litre suitable for total volume of Glycol - Water Solution, circuit along with necessary accessories such as 2 Nos pumps with Control Panel and accessories (1 x working +1 x standby) with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tank connection's should be as per OEM recommendations and 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank. The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (with lates Revision) and Rated at PN 16 and ASME Stamped. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system. The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panel IP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U value Insulating Material and cladded with aluminium Sheet (20G), complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
MAKE UP TANK :- Supply, installation, testing and commissioning of Make up Water Tank of capacity 550 litre for Pocket 1, Rectangular/Circular MS (IS 2062) construction with inlet, outlet, overflow, drain and vent with flame arrestor, tank will be made out of 4 mm thick MS sheet with supporting made out of minimum 50mm NB class 'B' pipe to keep tank base at minimum (1000mm) above FFL service platform shall be provided. The tank shall be provided with remote indication and level provided with remote indications and level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Makeup Water tank as described above should be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G), complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Ceiling Suspended Fan Coil Unit complete with G.I. casing with bottom return Air Plenum (5mm PE insulation) or as per site requirement, Filter box with 8mm Nylon Filter, 3/4 Row Deep cooling coil with coper tube diameter is 9.52 mm and thickness 0.33 mm with hydrophilic Aluminium fins. An air vent in the coil must be provided. Complete coil must be designed for standard working pressure is 1.6 MPa (16bar) and the test pressure is 3.3MPa (33bar). Unit to be provided with SS drain pan with 5mm/10 mm PE insulation/OEM designed as required . Direct driven fan (three speed) motor/OEM Designed, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with electronic Thermostat having LCD and touch button. It has to based on microprocessor operations which can realize intelligent control of room temperature. ESP for the Fan Coil Unit be as per mentioned below, Else Specified. The Capacity calculation sheet for Heating application of unit should be in Line with ASHRAE/ Eurovent Standard for Fan Coil and to be approved by Consultant/Eurovent or ASHRAE Certified. OEM Should supply the capacity rating at all three speeds with as per required paramters of Site. The Cut outs to be made in ceiling as per the Machine for the Servicing purpose/Trape Door should be included in the price.Minimum Capacity at Hot Water Inlet : 60 Degree Celcius and Hot Water Outlet: 50 degree Celcius should be as follows :-

-

-

-

... More
(i) Unit to be provided with electronic Thermostat having LCD and touch button and 2 Way Valve. It has to based on microprocessor operations which can realize intelligent control of room temperature. It shall also have RS485 Modbus communication function or Bacnet for BMS control. (ii) Unit to be installed with Ball Valve/Butterfly Valve at Inlet and Oulet as per Pipe Diameter and Auto Air vent. The all accessiroes required for proprer fucntioning of unit should be included as per OEM recommendation. The desired U trap should be given as per the site Requirement.

-

-

-

... More
(a) 2.5 kW (External Static Pressure: 50 Pa) (Toilet Area - CHS Plant, Dinning Hall ) Reference Model - FWW200VC, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

2

-

-

... More
(b) 5 kW (External Static Pressure: 50 Pa) (Cook House, Plate Wash Area - Dinning Hall, CHS Plant Room, Study Room, 02 HAV's) Reference Model - FWW500VC, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

13

-

-

... More
(c) 9 kW (External Static Pressure: 50 Pa) (Servery - Dining Hall) Reference Model: FWW800VC, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

1

-

-

... More
(d) 12 kW (External Static Pressure: 100 Pa) (GF - Toilet Area, Passage, 20 Ors, FF- Passage) Reference Model : FUW015A, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

20

-

-

... More
(e) 18 kW (External Static Pressure: 100 Pa) (40 ORs), Reference Model: FUW020A, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

8

-

-

... More
(f) 30 kW (External Static Pressure: 100 Pa) ( Corridor- Dinning Hall & Dinning Hall) Reference Model: FUW035A , complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

3

-

-

... More
Pre - insulated MS pipe , Class 'C' having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 gauge GI cladding complete suitable for above ground as per sizes mentioned below. Note :- (i) The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temperature range of -50 Degree Celcius to 120 Degreec Celcius. (ii) The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Makes: ZECO/Seven Star/Lloyd/Parma Pipe

-

-

-

... More
Inside Building

-

-

-

... More
(a) 100 mm with 50 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
(b) 80 mm with 50 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

250

-

-

... More
(c) 65 mm with 36 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

250

-

-

... More
(d) 40 mm with 36 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

250

-

-

... More
(e) 32 mm with 36 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
(f) 20 mm with 36 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Burried

-

-

-

... More
(g) 100 mm with 50 mm PUF thickness and HDPE Cladding, 26 Gauge, complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
(h) 80 mm with 50 mm PUF thickness and HDPE Cladding, 26 Gauge, complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
Supply,Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping 25mm dia pipe, Insulation thickness - 19 mm complete with fittings (elbows, tees, reducers, sockets,U trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supply,Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping 32mm dia pipe, Insulation thickness - 19 mm complete with fittings (elbows, tees, reducers, sockets,U trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping 40mm dia pipe, Insulation thickness - 19 mm complete with fittings (elbows, tees, reducers, sockets,U trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply and installation of perforated painted with powder coating M.S. cable trays of size 150 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required at site, complete all as specified and directed by Engr-in-Charge.

300

-

-

... More
Supply, Installation, Testing Balancing and Commissioning of factory fabricated GSS rectangular/ round ducting thickness: 22 gauge Sheet of Hot dipped Galvanised with 120GSM Zinc coating including plenum as reuired at site as per IS 655 - 2006 complete with gaskets, elbows, splitters, vanes, supports adjustable dampers, etc. as per approved drawings. The price shall include necessary scaffolding required for working at required height.

500

-

-

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 15 mm thick Supply and Application of Acoustic Insulation with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/Cum passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents, complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Supply & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply and fixing of Flexible connection Duct, complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Duct insulation of 25 mm thickness with resin fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following :- (a) Cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Applying rubber based adhesive CPRX compound. (c) Sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mitre, complete all as specified and directed by Engr-in-Charge.

250

-

-

... More
Supplying, fixing, testing and commissioning of 100 mm dia butter fly valve with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets (PN-16 Rating) Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets , strainers gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section/HPDE Caldding for Buried as specified, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supplying, fixing, testing and commissioning of 80 mm dia butter fly valve with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets (PN-16 Rating) Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets , strainers gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section/HPDE Caldding for Buried as specified, complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supplying, fixing, testing and commissioning of 32 mm dia butter fly valve with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets (PN-16 Rating) Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets , strainers gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section/HPDE Caldding for Buried as specified, complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply and fixing Y - STRAINER of size 32mm dia (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing NON - RETURN VALVE of size 32 mm dia (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing automatic Air Purger Valves for hot water circulation header, complete all as specified and directed by Engr-in-Charge. Makes : Audco/C&R/Adverse/Anergy/MES approved supplier

20

-

-

... More
Supply and fixing of Air Separator of size 32 mm, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing SITC of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply and fixing SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-100 C. Brass oil filled thermowell of 1/2" size as required by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply & Laying/ fixing of 400 sq.mm 3.5 Core size XLPE insulated and PVC sheathed aluminium conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray), complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
Supply & Laying/ fixing of 10 sq.mm 4 Core size XLPE insulated and PVC sheathed copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray), complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply & Laying/ fixing of 6 sq.mm 4 Core size XLPE insulated and PVC sheathed copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray), complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply & Laying/ fixing of 2 X 2.5 sq.mm single Core size XLPE insulated and PVC sheathed copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray), complete all as specified and directed by Engr-in-Charge. Note :- Two run of cable shall be measured as 1 Running Metre.

200

-

-

... More
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply and fixing rubber matting conforming to IS-15652-2006 complete as required of size 2mx1mx 25 mm, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed. NOTE :- (i) The glycol concentrate shall be mixed with potable water supplied and filled in central heating system pipe line after proper leakage test of entire circuit. The glycol water mixture ratio shall be 55:45 and freezing temperature shall be - 45° C (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe line Storage Tank, complete all as specified and directed by Engr-in-Charge.

3097

-

-

... More
External Electric Supply

-

-

-

... More
Supply , installation testing and commissioning step down 11/0.433 KV off load transformer, 3 Phase 4 wire AC, 50 cycles, 1000 KVA copper wound out door type transformer step up/ step down, type with off load manual tap changing arrangments on HT side to vary secondary voltage upto ± 7.5% with step of ± 2.5% including suitable cable entry boxes on both side to receive HT/LT XLPE cable complete in all respect with standard accessories and fitments conforming to IS-1180 level -III and IS 2026 Dy-11 connection complete all as specified and directed. Transformer shall be painted with two coat of smoke gray epoxy paint confirming to IS - 632, complete all as specified and directed by Engr-in-Charge and comprising the following :- (a) Rating and diagram plate. (b) Earthing terminal two Nos (c) Thermometer pocket (d) Air release valve with plug (e) Winding temperature/Oil temperature indicator housed in a separate box (f) Conservator with oil indicator (g) Silcagel breather assembly

1

-

-

... More
Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type triple pole mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 400 Amp, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Air break switch insulator for 11000 volts suitable for current rating 400 Amps, complete all as specified and directed by Engr-in-Charge.

18

-

-

... More
Supply, laying, jointing & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts earthed grade, of size 3 core 185 sq mm, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Steel tubular swaged pole erected in vertical position type 410 SP-55 (11 Mtr long with 300mmx340mm x6mm thick mild steel base plate continously welded to pole, finial taper plug , bolts, nuts and screws all as specified including factor paint internally throughout and externally for embeded portion and making 30 cm strips yellow and black with synthetic enamelled paint over as coat of red oxide primer upto 1.5 meter from ground level / coping and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection complete including making pole number , complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Lightning arrestors impulsion type complete with all fittings, transmission class , discharge capacity 65 Kamps 11000 volt, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat , one under coat and one finishing coat of paint , complete all as specified and directed by Engr-in-Charge.

2.8

-

-

... More
Anti climbing devices comprising spike type fabricated out of MS bars (round, square or flat) including nuts, bolts washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified and directed by Engr-in-Charge.

0.3

-

-

... More
Danger notice plate of of 1.6mm thick mild steel sheet , vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25 x 20 cm size, complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
ACSR conductor for overhead line 11 KV of size 6/1x3.00mm Ferret, complete all as specified and directed by Engr-in-Charge.

2.2

-

-

... More
Single disc insulator assembly for tension with tension clamps for conductors working pressure 11000 volts, porcelain, vitreous brown or green insulator including two galvanised iron washers and one galvanised iron nut, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Pin type, porcelain , vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut, 150mm height,150mm dia for 11000 volts grade, complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Galvanised steel tubing light grade with all fitting and laid in trenches or fixed along wall /poles of size 100 mm dia, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supplying, installation, testing and commissioning of cubical type wall / floor mounted Distribution Panel suitable for Indoor application for 415V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick , including cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable Amp capacity extensible type Copper bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 50kA, the bus bar spacing Ph-Ph, Ph-N, Ph-body/Earth shall be designed for altitute 3500 mtrs the design shall be approved by Engineer in Charge with Entire panel shall have a common earth bus of suitable size at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of aluminium bus bars 2500 Amp rated and control panel wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alloys, cable gland plates. providing & fixing following switch gears:- Incomming (a) ACB MDO microprocessor based, 415 Volt, 4 pole 1600 Amp 50 KA -01 No (b) Digital multi functional panel meter showing volt, frequency, PF along with CTs - 01 set (c) Indicator lamp LED type RYB - 01 Set Outgoing (a) ACB MDO microprocessor based 4 pole630 Amp 36 KA -03 Nos (For HOT Water Generator) (b) On load Changeover switch 1600 Amp, 4 pole - 01 No (c) MCCB 400 Amp , 4 pole, 36 KA thermal magnetic - 01 No (Notes : (i) Incoming and ougoing cable shall be fixed with appropriate size of lugs (ii) Entries of all size of cables in panel should be done through adequate size of metallic cable glands All connection shall be made through spreader link between bus bar and ACB/MCCB, complete all as specified and directed by Engr-in-Charge. (iii) Design and drawing of panel shall got approved from GE prior execution at site.

2

-

-

... More
Supply, laying, jointing and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core, complete all as specified and directed by Engr-in-Charge.

65

-

-

... More
Supply, laying , jointing and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630 sq mm 3½ core, complete all as specified and directed by Engr-in-Charge.

85

-

-

... More
Dry sand cushioning to underground electric cable 8mm thick before laying of cable and 15cm thick after laying of cable laid in trenches, complete all as specified and directed by Engr-in-Charge. Note :- Punned thickness shall be measured.

9

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat of size 250mm x150mm x 40mm placed perpendicular of the cable, complete all as specified and directed by Engr-in-Charge.

1150

-

-

... More
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc, complete all as specified and directed by Engr-in-Charge.

18

-

-

... More
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron earthing lead wire 4.00 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of soil PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron earthing lead wire 4.00 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc, complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping padestal to poles including provision of necessary form work finishing the exposed surface even and smooth, complete all as specified and directed by Engr-in-Charge.

2.25

-

-

... More
Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3, complete all as specified and directed by Engr-in-Charge.

7.5

-

-

... More
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash to the portion of PCC muffs above ground level, complete all as specified and directed by Engr-in-Charge.

1.3

-

-

... More
Supplying, installation, testing & commissioning of cubical type wall/floor mounted Distribution Panel suitable for Indoor application for 415V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm , i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable Amp capacity extensible type aluminium bus bars 600 Amp of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 50kA, the bus bar spacing Ph-Ph, Ph-N, Ph-body/Earth shall be designed for altitute 3500 mtrs the design shall be approved by Engineer in Charge with Entire panel shall have a common earth bus of suitable size at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of Copper bus bars and control panel wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alloys, cable gland plates. providing & fixing following switch gears:- Incomming (a) MCCB microprocessor based, 415 Volt, 4 pole 400 Amp 36 KA -01 No (b) Digital multi functional panel meter showing volt, frequency, PF along with CTs - 01 set of siutable ratio. (c) Indicator lamp LED type RYB - 01 Set Outgoing (a) 40 A 10 KA MCB 4 pole- 02 Nos ( for Glycol centrifugal Pumps). (b) 315 A 36 KA MCCB microprocessor based, 415 Volts, 4 pole- 02 Nos (Heater for Storage Tank) (c) 63 A 25 KA MCCB microprocessor based, 415 Volts, 4 pole- 03 Nos (Heater for UG Storage Tank) (d) 40A 10 KA MCB SPN - 06 Nos (Tracer element , circulation pumps) All connection shall be made through spreader link between bus bar and ACB/MCCB,

1

-

-

... More
External Water Supply

-

-

-

... More
Steel water tubing galvanized medium grade 25 mm dia laid in trenches/walls including all necessary fittings clamps etc complete and connecting to existing system, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Steel water tubing galvanized medium grade 20 mm dia laid in trenches/walls including all necessary fittings clamps etc complete and connecting to existing system, complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Gun metal gate valves with iron wheel head screwed both ends for GI pipe of 25 mm dia, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Gun metal gate valves with iron wheel head screwed both ends for GI pipe of 20 mm dia, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Providing tracer / antifreezing cable required to keep the pipe warm to avoid freezing of GI and DI pipe , complete all as specified and directed by Engr-in-Charge.

114

-

-

... More
Cutting existing steel tubing or alternations or addition screwing existing steel tubing for making connections, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Construction of new brick masonary valve pit chamber of size 600x600x900mm (Internal size) with 230 mm thick brick wall in CM (1:4), 15mm plastering on internal & external surfaces in CM (1:4), 75mm thick PCC(1:4:8) type D-2 using 40mm graded crushed stone aggregate including MS sheet cover 3mm thick hinged with 40x40x6mm MS angle iron frame having locking arragements. Cover is painted with two coat of synthetic enamel paint over one coat of red oxied primer including necessary earth work and removal of surplus soil to a distance n.exc. 50m and deposited, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Chain Link Fencing

-

-

-

... More
Cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, fillings and mass concrete, complete all as specified and directed by Engr-in-Charge.

1.2

-

-

... More
Rolled Mild Steel Plates 6mm thick (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and directed by Engr-in-Charge.

230

-

-

... More
Applying two coats of synthetic enameled paint over a coat of red oxide primer on new steel surface, complete all as specified and directed by Engr-in-Charge.

20.4

-

-

... More
Joist channel angle or tee sections, fixed independently without connecting plates etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated), complete all as specified and directed by Engr-in-Charge.

380

-

-

... More
Chainlink Mild Steel galvanised fencing, 3.8 mm dia size or type including line wires any mesh size and type of standards, rails, straining bolts etc including provision of binding wire, complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
Sewage Disposal

-

-

-

... More
150 mm dia RCC NP-3 in any type of soil at average depth of 0.70-1.65 m, inclusive of manholes / drop manholes of standard size made of brick masonery / RCC / Precast RCC with SFRC ventilating cover and frame, includes all items and activities to execute and make sever the functional in 150 mm thick moorum/ sand/ crushed stone, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Soakage well of size 1.2M dia x 0.3M deep, excavation in any type of Soil, foundation in PCC 1:3:6 wells of Honey combed and solid in M-25 concrete, inlcuding intercepting chamber, screen chamber brick work in CM, RCC cover slab in M-25, RR masonry, Filling with brick bats, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Conventional type RCC septic tank for 50 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, base slab, baffle walls and roof slab incl beams with Vent shaft, manhole openings with cover connection etc complete with effective depth of 1.5 meter and overall depth of 3 meter, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Road, Path and Culvert

-

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete as in stone edging and position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 course sand), incl making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm, including making drainage opening where required, complete all as specified and directed by Engr-in-Charge.

5.1

-

-

... More
Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS: 15658-2006 of 60 mm thickness, M-35 Grade, complete all as specified and directed by Engr-in-Charge.

165

-

-

... More
Sand filling under floors or in foundations including watering and consolidation , complete all as specified and directed by Engr-in-Charge.

4.13

-

-

... More
75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in sub base, complete all as specified and directed by Engr-in-Charge.

166

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.