Military Engineer Services Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 50,740Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_674412_2Tender No
81203/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
76.5
-
-
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed.
42
-
-
Supplying and laying, factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
2800
-
-
Material and labour for taking out the existing defective 3 core 95Sqmm to 185Sqmm HT cable from trenches including cable cover from poles/drains/under roads and relaying the cable after rectifying the defect, complete all as specified and directed. Note:- Necessary earth work shall be measured and paid seperately.
250
-
-
Supply, laying, jointing, testing and commissioning of High Tension (HT), 11000Volts (earthed) grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with multi stranded aluminum conductor, cross sectional area 120 Sqmm, 3core under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, including taking down old cable, complete all as specified and directed Note : Excavation and earth work, sand cushioning and precast concrete cable cover for protection of cable shall be measured and paid separately. Make : Polycab/Havells/Gloster.
350
-
-
All as per item No 8. above but of size 95 Sqmm,3 core
300
-
-
Supply, jointing & testing, straight through joint kit cold shrinkable type complete with jointing material and accessories suitable for 11KV grade (earthed), HT, underground XLPE insulated armoured aluminium conductor, 3core 120Sqmm to 185 Sqmm size cable, in repairs complete all as specified and directed.
Make : 3M/Universal/Raychem
10
-
-
All as per item No 10 here-in-above but of 3 core 95 sqmm size cable.
4
-
-
Material and labour for outdoor end termination joint kit cold shrinkable type complete with jointing material and accessories suitable for 11KV grade (earthed), HT, underground XLPE insulated armoured aluminium conductor, 3core 95 Sqmm size cable but in repair, complete all as specified and directed.
Make : 3M/Universal/Raychem
15
-
-
Material and labour for indoor end termination joint kit cold shrinkable type complete with jointing material and accessories suitable for 11KV grade (earthed), HT, underground XLPE insulated armoured aluminium conductor, 3core 120Sqmm to 185 Sqmm size cable but in repair, complete all as specified and directed. Make : 3M/Universal/Raychem
20
-
-
Suply and Fixing for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) including numbering of poles with aluminium paint and painting up to 1.5 meter above PCC coping of poles in black and white strips 5 number including taking down old complete all as specified and as directed by Engr-in-Charge. (Excavation, earth work, foundation concrete and coping etc will be measured and paid separately as per relevant SSR part-I and part-II norms).
4
-
-
Supplying and fixing out door, triple pole, gang operated switch single bank, tilting type suitable to vertical/horizontal mounting consisting of hot dipped electro plated galvanised channel iron base with drop out fuse having 15 Nos insulators 11 KV, copper/copper alloy tinned contacts, copper or chromium plated MS arcing chains capable of making and breakign the magnetising current complete with horizonatal bar, GI pipe as down level coupling and operating handle with locking arrangements and drop out fuzes working voltage 11000 volts 200 Amps including testing and dismantling old complete all as specified and directed
3
-
-
Supplying and fixing out door, triple pole, gang operated switch single bank, tilting type suitable to vertical/horizontal mounting consisting of hot dipped electro plated galvanised channel iron base with drop out fuse having 09 Nos insulators 11 KV, copper/copper alloy tinned contacts, copper or chromium plated MS arcing chains capable of making and breakign the magnetising current complete with horizonatal bar, GI pipe as down level coupling and operating handle with locking arrangements and drop out fuzes working voltage 11000 volts 400 Amps including testing and dismantling old complete all as specified and directed
3
-
-
Material and labour for pin type, porcelain, vitreous brown insulator including one galvanised mild steel spindle, 02 Nos, GI washer & 01 No GI nut of 150mm height and 150mm dia for 11000 volts grade including dismantling old complete complete all as specified and directed by Engr-in-charge.
15
-
-
Material and labour for Lighting Arrestor expulsion type for out door use complete with all fittings transmission class discharge capacity 65 kilo Amps suitable for 11000 V including bracket, clamps, nuts, bolts and washers and connecting to earth wire including dismantling old complete all as specified and directed by Engr-in-charge.
6
-
-
Material and labour for Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
0.7
-
-
Material and labour, PCC (1:3:6) type C-1, using 20mm graded crushed stone aggregate, as in coping to parapet walls, electric poles etc., weathering slightly, rounded or chamfered including use waste and necessary form work , complete all as specified and directed.
1.5
-
-
Material and labour for Cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminium paint over a coat of red oxide primer, including dismantling old complete all as specified and directed.
5
-
-
M&L for Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered including dismantling old complete all as specified and directed.
Note;- Clamps measured and paid seperately)
0.2
-
-
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and
conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size including dismantling old complete all as specified and directed.
10
-
-
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32 x 6mm as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc all as shown in Electrical Plate No. 3 of SSR Part 1, including dismantling old complete all as directed and specified.
6
-
-
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc all as shown in Electrical Plate No. 3 of SSR Part 1, including dismantling old complete all as directed and specified.
6
-
-
S&F in replacement of galvanised iron strip of 32mmx6mm complete all as directed and specified.
20
-
-
Disconnecting 11KV electric supply from existing VCBs for maintenance and servicing/ overhauling of existing indoor type, horizontal draw out type VCB, of current rating 630 Amps by disconnected HT cable termination joints, checking serviciability of all parts, cleaning all parts with cleaning agent and cleaning spray to avoid any chance of flashing, loose connection, speeling, any break out parts, replacement of connecting nuts, bolts and washers in found damaged due to flashing of appropriate size. Testing, calibration and replacement if required of earth fault relay, Overload relay, feeder management relay, TC supervision relay, Annunciator, master trip relay, TRF fault relay, DC fault relay complete with reconnection of all dismantled cable, charging of VCB and testing complete with satisfaction of GE and Engineer-in-Charge. Note:- The servicing of VCB including calibration of relays shall be carried out through OEM/Authorized dealer/Channel Partner of manufacturer of VCB and payment of relay paid in respective seperate items. Make:- Schneider
2
-
-
All as per item No. 27.00 here-in-before but 11 KV VCB 400 amps complete all as specified and directed. Make-Schneider
3
-
-
Replacement of unserviceable earth fault over current relay of capacity 400Amps to 630 Amps for 11 KV VCB of make schneider or any other make approved by schneider complete all as specified and directed.
2
-
-
M&L for opening, checking and testing of trasformer of capacity 250/400KVA in HT copper winding coils of required size with super enameled superior quality copper wire of suitable size and specification, complete with insulation, varnishing, vaccum impregnation and baking of coil assembly etc, complete all as specified and directed.
60
-
-
M&L for opening, checking and testing of trasformer of capacity 250/400KVA in LT copper winding coils of required size with super enameled superior quality copper wire of suitable size and specification, complete with insulation, varnishing, vaccum impregnation and baking of coil assembly etc, complete all as specified and directed.
100
-
-
Supply and fix in repair HT bushing complete with gasket, for transformers of capacity 250 KVA to 400 KVA all as specified and directed.
3
-
-
Supply and fix in repair LT bushing complete with gasket, for transformers of capacity 250 KVA to 400 KVA all as specified and directed.
4
-
-
Supply and fix in repair HT stud (brass) with nuts and bolts with gasket complete set for transformers of capacity 250 KVA to 400 KVA all as specified and directed.
3
-
-
Supply and fix in repair LT stud (brass) with nuts and bolts with gasket complete set for transformers of capacity 250 KVA to 400 KVA all as specified and directed.
3
-
-
Supply and replacement of Silica gel breather assembly with silica gel cristal (500 gram) for 400 KVA capacity transformer.
3
-
-
Supply of transformer oil superior quality having di-electric strength not less than 50 KV at 2.0mm gap, ISI marked, 200 liter sealed drum, and filling, topping up into transformers and voltage stabilizer, complete all as specified and directed.
1050
-
-
Disconnecting the voltage stabilizer of capacity upto 10 KVA 3 Phase 415 V, from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & interconnections, Reassembling of the voltage stabilizer after carrying out the repair work and testing the same after repair and replacement of electronic relays, control circuit, indicator lamp , auto manual switch and other connected item complete all as specified and as directed by Engineer-in-charge.(Spares required/replaced will be measured and paid separately under the respective sch of item ) if required.
4
-
-
Disconnecting the voltage stabilizer of capacity upto 50 KVA 3 Phase 415 V capacity, single phase dry type from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & inter connections, Reassembling of the voltage stabilizer after carrying out the repair work and testing the same after repair and replacement of electronic relays, control circuit, indicator lamp , auto manual switch and other connected item complete all as specified and as directed by Engineer-in-charge.
Note:- (Spares required/replaced will be measured and paid separately under the respective sch of item ) if required.
7
-
-
Supply and fixing in repair servo motor of capacity 3 kg suitable upto 50 KVA 3 Phase 415 V complete all as specified and as directed by Engineer-in-charge
3
-
-
Supply and fixing in repair auto transformer(Dimmer) of input voltage single phase 90 to 270 volts and output voltage single phase 230 volts for power 50 KVA complete all as specified and directed by Engineer-in-charge.
2
-
-
Disconnecting the voltage stabilizer of capacity upto 51 KVA to 100 KVA 3 Phase 415 V capacity, single phase dry type from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & interconnections, Reassembling of the voltage stabilizer after carrying out the repair work and testing the same after repair and replacement of electronic relays, control circuit, indicator lamp , auto manual switch and other connected item complete all as specified and as directed by Engineer-in-charge.(Spares required/replaced will be measured and paid separately under the respective sch of item ) if required.
1
-
-
Supply and fixing in repair servo motor of capacity 5 kg suitable upto 51 KVA to 100 KVA 3 Phase 415 V capacity complete all as specified and as directed by Engineer-in-charge
1
-
-
Supply and fixing in repair control circuit complete including soldering the same with existing circuit upto 51 KVA to 100 KVA 3 Phase 415 V capacity complete all as specified and as directed by Engineer-in-charge
1
-
-
Supply and fixing in repair auto transformer(Dimmer) of input voltage single phase 90 to 270 volts and output voltage single phase 230 volts suitable for power 51 to 100 KVA Voltage stabilizer complete all as specified and directed by Engineer-in-charge.
1
-
-
Disconnecting the voltage stabilizer of capacity upto 101 KVA to 320 KVA 3 Phase 415 V capacity, single phase dry type from electric circuit, strip opening of the same for repair work and replacement of worn out parts including wiring & interconnections, Reassembling of the voltage stabilizer after carrying out the repair work and testing the same after repair and replacement of electronic relays, control circuit, indicator lamp , auto manual switch and other connected item complete all as specified and as directed by Engineer-in-charge.
1
-
-
Supply and fixing in repair servo motor of capacity 10 kg upto 101 KVA to 320 KVA 3 Phase 415 V capacity complete all as specified and directed by Engineer-in-charge.
1
-
-
Supply and fixing in repair control circuit complete including soldering the same with existing circuit complete all as specified and directed by Engineer-in-charge.
1
-
-
Supply and fixing in repair auto transformer(Dimmer) of input voltage single phase 90 to 270 volts and output voltage single phase 230 volts suitable for power 100 to 320 KVA Voltage stabilizer complete all as specified and directed by Engineer-in-charge.
1
-
-
Disconnecting the UPS of capacity upto 10 KVA from electric circuit, strip opening of the same for repair work and replacement of worn out parts, Reassembling of the UPS after carrying out the repair work and testing the same after repair of control circuit, transformer (step down/ step up), Auto & Manual switch. for its functioning to the satisfaction of Engineer-in-charge.
Note;- Rate of All spare parts required at ground are included in quoted rate.
1
-
-
Material and labour for 40mm coarse aggregates filling in sub stations with proper leveling complete all as specified and directed by Engineer in charge
4
-
-
M&L for Filtration, dehydration of transformer oil as drain out from transformer of existing any Capacity, 11 KV here-in-above to make the oil fit for reuse by improving its dielectric strength not less than 45 KV below 45 KV dielectric strength oil shall be replaced with new oil
Note:- (new oil for toping/or for replacement shall be measured and paid separately under appropriate item of sch 'A') .
3200
-
-
Note : Schedule of credit for Rs. 1,38,250.00 to be deducted on acceptance of bid.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%