Military Engineer Services Tender

... More
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Eprocure
Opening Date27 Feb 2025
Closing Date20 Mar 2025
Tender Amount₹ 13,35,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, complete all as specified and directed by Engr in Charge.

32

-

-

... More
Replacement of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-I flate size 250 x 150x40mm , complete all as specified and directed by Engr in Charge.

2622

-

-

... More
Taking out U/S LT UG cable for relaying/ replacement any size cable all as directed by Engr-In-Charge. Note:- Excavation and earth work shall be measured paid separately under respective item.

562

-

-

... More
Supply and Laying in trenches or passing through pipe or fixed on surface XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade of under mentioned sizes :-

-

-

-

... More
(a) 35 Sqmm 3.5 core

140

-

-

... More
(b) 25 Sqmm 3.5 core

90

-

-

... More
(c) 95 Sqmm 3.5 core

182

-

-

... More
(d) 50 Sqmm 3.5 core

150

-

-

... More
M& L in replacement of GI Pipe light grade of size 40 mm dia for cable protecton in road crossing and making good surface of road by filling with PCC 1:2:4 type B2 (using 40mm graded aggregate) complete all as specified and directed by Engr in Charge.

20

-

-

... More
All as per item Ser No 8 above, but of Size 80 mm dia.

12

-

-

... More
Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed by Engr-in-Charge. Note : GI pipe shall be measured and paid separately.

12

-

-

... More
Material & labour for installing, testing and commissioning of factry made bus bar chanber comprising of 4 Nos aluminium bus bar of 200 Amp rating supported on insulator and enclosed with sheet steel enclosure out door type made out of 3.15 mm thick CRCA sheet, with top edge tappered, dust and vermin proof , having locking arrangement at front and opening arrangement from front & rear both including fixing arrangement on pole/gorunting in floor, with colour coded FRP with compression cable glands for entry & exit of cables, powder coated all specified and directed by Engr-in-Charge.

3

-

-

... More
Supply & Installation, testing and Commissioning in replacement of LT Panel cubical type out door floor mounted weather proof totally enclosed, (CPRI approved) factory made and made out of 3 mm thick CRCA powder coated sheet and angle iron complete with bus bar of copper of suitable size for capacity 600 Amps 3 Phase and Neutral 415 Volts 50 Hz mounted on epoxy type insulators with PCC flooring and angle iron base frame complete all as directed by the Engr-in-charge including fallowing accessories:- a) MCCB 400 Amps Cap 4 Pole 36 KA 415 Volts - 1 No for( I/C) b) Change over switch open execution type 200 Amp 4 pole - 01 No c) MCCB 200 Amp cap 3 pole 25 KA 415 Volts - 1 No d) MCCB 100 Amp cap 3 pole 16 KA 415 Volts - 3 Nos e) Digital Volt meter with sellector switch(0-500V) - 02 Set f) Digital Amp meter with sellector switch with necessary CT (0-500A) - 02 Set g) LED indicating lamp - 02 Set Note : (i) The Make of Change over and MCCB considered are Havells/Standard/Indo Asian/HPL (ii) The rates deemed to be inclusive of suitable size copper wiring/copper strips from Main I/C MCCBs to Change over switch, Change over switch to Main Bus bar and Bus Bar to Outgoing MCCBs complete all as specified and directed. (iii) The design of Panel, Make of complete accessories and drawing of the LT Panel should be submitted by the Contractor for pre-approval from the Engineer-in-charge before order and execution at site.

1

-

-

... More
Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge.

371

-

-

... More
Point wiring complete with 1.5 Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead all as specified and directed for the following:-

-

-

-

... More
(a)   One light/exhaust fan point controlled by one way switch

204

-

-

... More
(b) One 3 pin switch socket combination 5 Amp on independent board complete all as specified and directed.

83

-

-

... More
(c) One 3 pin socket out let 5 Amp on the same board with other switches complete all as specified and directed.

24

-

-

... More
(d)   One bell point controlled by one bell push switch

1

-

-

... More
All as item No 14 above, but using cable 2.5 Sq mm size but using cable 2.5 Sq mm size for 3 pin socket out let 15 Amp on independent board.

56

-

-

... More
All as item No 14 above, but using cable 4 Sq mm size for geyser point

3

-

-

... More
Supply and replacement of lamp holder insulated body with back plate.

42

-

-

... More
Supply and fix of Switch piano flush button single pole 6 Amps 230 volts one way complete all as directed.

228

-

-

... More
Supply and fix of switch Socket combination flush type 3/5 pin 5/6 Amps 230 volts complete all as directed.

83

-

-

... More
Supply and fix of Socket outlet 3 pin, 5A, flush type complete all as directed.

24

-

-

... More
Supply and fix of switch Socket combination 5 pin 5 & 15 Amps flush type.230 volts complete all as directed.

56

-

-

... More
Supply and fix of Ceiling rose, surface Bakelite three terminals complete all as directed.

162

-

-

... More
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 8 Way all as specified and directed by Engr-in-Charge.

8

-

-

... More
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used tripple pole & neutral 415 Volt 4 Way all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 12 Ways all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used Single pole and neutral 240 Volt 4 Ways all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fix MCB TPN 100 Amp 415 Volts AC ISI marked all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fix MCB SPN 40 Amp 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge.

12

-

-

... More
Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supply and fixing in replacement Air circulator made of sturdy Engineering plastic complete with louvers, shutter, voltage 230 volt, 50 Htz RPM 1200, copper winding of sweep 250 mm complete all as specified and directed by Engr-in-Charge.

13

-

-

... More
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected using galvanised iron strip 25×4mm as earthing leadby means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.

4

-

-

... More
M & L for submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x4.0 sq. mm + 1x4 sq. mm earth wire complete all as specified

116

-

-

... More
M & L for submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x6.0 sq. mm + 1x6 sq. mm earth wire complete all as specified

100

-

-

... More
S & F in replacement of old U/S decorative durable LED batten fitting of 18/20W , 4 feet long with decorative and caps, powder coated CRCA decorative for LED tube of any capacity, 4 feet long (white colour) tube having driver ,connector block etc complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as required at site or directed by Engr in Charge.

114

-

-

... More
S&F in replacement of Old U/S Lamp LED 7/9 Watt, 230 volts 50 Hz AC complete all as specified.

42

-

-

... More
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.

6

-

-

... More
Supply and fixing in replacement of electrical bell (multi music type), AC, 230 Volts complete all as specified and directed by Engr in Charge.

1

-

-

... More
Supply and fixing in replacement of electrical bell push flush type 5 Amp complete all as specified and directed by Engr in Charge.

1

-

-

... More
S&F in replacement of Old U/S fancy light of any type and supply amd fix New LED fancy light 7/9 Watt, 230 volts 50 Hz AC complete all as specified.

11

-

-

... More
Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equiped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge.

18

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.