Military Engineer Services Tender

... More
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Military Engineer Services - MES Tender

Works
Electrical Works
Eprocure
Opening Date25 Mar 2025
Closing Date29 Apr 2025
Tender Amount₹ 4,71,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Total amount of Sch 'A' Part - III (Internal Electric Supply for Existing Bldgs)

1

138045

-

... More
Total amount of Sch 'A' Part - IV (Insulation of Annexe Bldg Walls & Celling)

1

9279585

-

... More
Total amount of Sch 'A' Part - V (Underground Sump)

1

302701

-

... More
Total amount of Sch 'A' Part - VI Section-I (Hot Water Supply System-1)

1

59944

-

... More
Total amount of Sch 'A' Part - VI Section-II (Internal Water Supply for Hot vWater Supply)

1

13996

-

... More
Total amount of Sch 'A' Part - VII Section-I (Central Heating System)

1

371706

-

... More
Total amount of Sch 'A' Part - VIII Section-I (External Water Supply)

1

13462

-

... More
Total amount of Sch 'A' Part - IX (External Electric Supply)

1

1500609

-

... More
Total amount of Sch 'A' Part - X (Sewage Disposal)

1

47479

-

... More
Total amount of Sch 'A' Part - XI (Chain Link Fencing)

1

74226

-

... More
SCHEDULE `A' PART - VI Section-III (Hot Water Supply) is not prepriced by MES and prepriced rates indicates 0.0 under column 7 signified this fact only.

-

-

-

... More
Hot Water Supply

-

-

-

... More
Hot Water Tank with inbuilt Heater: Supply of Horizontal / Vertical Type Storage Tank of capacity 6000 Litre, Construction - Made from Stainless Steel Sheet- SS 316, Sheet Thickness- 8mm thick Shell & 10mm thick Dish end Connection - Inlet / Outlet / Drain / Vent, Heater Rating - 30 KW x 5 Nos , 150 KW. Insulation - 100mm thick Puf Inulation (40 Kg/Sqcm density), Cladding - 24 gauge thick Aluminium Sheet,Test Pressure – 100 P.S.I G,Electrical Panel – Step Controller, Main incomer S.F.U, Outgoing Contactor, M.C.B, Master Thermostat for high temperature cut-out, Low level controller with sensor, Pressure Gauges with Ball Valves, Pressure Relief Valve, Auto vent Factory wired complete. Flameproof Heat tracing cable of 45 Watt/meter to operate at 230V single phase AC with total capcity of 8 KW, with junction boxes will be installed at bottom Dish end and on cylindrical portion with the help of self adhesive aluminium film. Panel should also include the OEM recommended MCB for Water Circulation pumps, complete all as specified and directed by Engr-in-Charge. Note :- (i) All neccassary accessories required for the proper functioning of Hot Water Generator are included in price. (ii) The prices should include lifting, shifting and positioning of units at Site. (iii) Hot Water Tank installation to be done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator, Insulation, all accessories required for proper fucntioning, etc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Structure, Mechanical Structure etc as recommended by Manufacturer. Make of Boiler: Rapid Cool/Rapid Therm

2

-

-

... More
Hot Water CENTRIFUGAL PUMPS: Supply, Erection, testing and commissioning of Flow: 20 USGPM, Head: 10 meter (Circuit: Hot Water Generator : Storage Tank) Horizontal/Vertical in line axial Split Coupled PN 16 centrifugal pumps complete with CED coating, externally flushed outside type balanced Mechanical Seal and non overloading motor, as per specifications and drawings.suitable HP, TEFC permanent magnet motor with Efficiency IE3, class ‘F’ insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply for each pump. The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -45 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps. Triple Duty Valve and Suction Guides to be provided by the pump manufacturer for the unit responsibility. Each pump shall comprise of following as required as per specifications. Note : (i) Electrical starter for pump set should be as OEM Recommendation. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump. (iii) 3 Nos. - 150 mm dia type pressure gauges (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation). (vi) Capacity and pump head should be not less than as mentioned above head each including the triple duct valve and End Suction guide. Make of Pump : Armstrong (Reference Model:4300 5012-007.5) / Xylem /Grundfoss/Wilo

2

-

-

... More
All as per para 6.02 above but flow : 10 USGPM 35 mitre head Hot water tank for Ring main, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply, installation, testing and commissioning of Heater Rating 10 KW with Ceramic Quoting to be installed in under ground storage tank, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Pre - insulated PPR pipe as IS:4984 having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 gauge GI cladding complete suitable for in side building above ground / underground / wall mounted of following sizes. The pipes should be insulated with closed cell puf of density 36 ± 2 Kg/Cum of under mentioned thickness. The Pipe should be workable in the temp. range of -50 Degree Celcius to 100 Degree Celcius. The All Accesories, U trap, Joints, Elbow and Joining of Pipes with OEM recommendation should be included in the rate of pipes.

-

-

-

... More
(a) 50 mm with 69 mm PUF thicknes and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

200

-

-

... More
(b) 50 mm with 69 mm PUF thicknes and 26 Gauge HDPE Cladding, complete all as specified and directed by Engr-in-Charge.

200

-

-

... More
(c) 40 mm with 65 mm PUF thicknes and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
(d) 25 mm with 60 mm PUF thicknes and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supplying and installing cable tray of size 150 mm width X 50 mm depth X 1.6 mm thickness of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling / Ground / wall with M.S. suspenders including bolts and nuts, painting suspenders etc. as required, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supplying, fixing, testing and commissioning of 80 mm dia Butterfly Valve valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts and Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section/HPDE Caldding for Buried, complete all as specified and directed by Engr-in-Charge. Note : Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet and O ring, Complete with fittings, Nuts, Bolts & Gaskets

16

-

-

... More
Y - STRAINER 80 mm dia (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
NON - RETURN VALVE 80 mm dia (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Automatic Air Purge Valves for hot water circulation header as specified and directed by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
SITC of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-100 C. Brass oil filled thermowell of 1/2" size as required by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Supply & laying/fixing of following size XLPE insulated, Amuminium conductor, ameured cabhle/unamoured as required of 1.1 KV grade complete as required. (ISI Marked) (In ground/In duct/en surface/ on cable tray)

-

-

-

... More
(a) 4 Core x 120 Sq mm

50

-

-

... More
(b) 4 Core x 10 Sq mm

50

-

-

... More
(c) 4 Core x 6 Sq mm

50

-

-

... More
SCHEDULE `A' PART - VII Section-II (Central Heating System) is not prepriced by MES and prepriced rates indicates 0.0 under column 7 signified this fact only.

-

-

-

... More
CENTRAL HEATING SYSTEM

-

-

-

... More
Electric Hot Water Generator : - Supply, installation, testing and commissioning of package type electric Hot Water generator constructed out of MS sheet having easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 300 KW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, as recommended by OEM. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual / auto rotary switches control and compatability, complete all as specified and directed by Engr-in-Charge. Note :- (a) All neccassary accessories required for the proper fucntioning of Hot Water Genearator shall be included in price. (b) The prices should include lifting, shifting and positioning of units at Site. (c) Hot Water Genearator installation to be done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulation,all accessories required for proper fucntioning, etc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation shall be included in ODU price which includes the Civil Structure, Mechanical Structure etc as recommended by Manufacturer.

3

-

-

... More
GLYCOL CIRCULATION CENTRIFUGAL PUMPS :- Supply, Erection, testing and commissioning of Vertical in line axial Split Coupled PN 16 centrifugal pumps Flow : 125 USGPM, Head: 35 meter complete with CED coating, externally flushed outside type balanced Mechanical Seal and non overloading motor, as per specifications and drawings.suitable HP, TEFC permanent magnet motor with Efficiency IE5, class ‘F’ insulation operating on 415 + 10% volts, 3 phase, 50 cycles AC supply for each pump. Pump should be provided with motor mounted IP55 integrated VFD for sensorless/wireless control( 2 nos of wireless DPTs should be considered for wireless control across the load). Pump mounted VFD must display dynamic frequency, amps, volts, real time flow and head of operating pump.The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -45 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . Suction Guides to be provided by the pump manufacturer for the unit responsibility. Fluid : Glycol 55%, Water 45%. Each pump shall comprise of following as required as per specifications :- (i) Electrical starter for pump set should be as OEM Recommendation. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump. (iii) 150 mm dia type pressure gauges - 3 Nos. (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation flow). (vi) Capacity and pump head should be not less than as mentioned above head each including the triple duct valve and End Suction guide. Make of Pump : Armstrong(Reference Model:4300 5012-007.5) / Xylem /Grundfoss/Wilo

3

-

-

... More
EXPANSION TANK AND PRESSURIZATION UNIT :- Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK of capacity Expansion Tank of 500 Litre suitable for total volume of Glycol - Water Solution, circuit along with necessary accessories such as 2 Nos pumps with Control Panel and accessories (1 x working +1 x standby) with Pressure Transmitter and interconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tank connection's should be as per OEM recommendations and 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank. The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (with lates Revision) and Rated at PN 16 and ASME Stamped. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system. The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panel IP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U value Insulating Material and cladded with aluminium Sheet (20G), complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
MAKE UP TANK :- Supply, installation, testing and commissioning of Make up Water Tank of capacity 550 litre for Pocket 1, Rectangular/Circular MS (IS 2062) construction with inlet, outlet, overflow, drain and vent with flame arrestor, tank will be made out of 4 mm thick MS sheet with supporting made out of minimum 50mm NB class 'B' pipe to keep tank base at minimum (1000mm) above FFL service platform shall be provided. The tank shall be provided with remote indication and level provided with remote indications and level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make UpWater tank as described above should be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G), complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Ceiling Suspended Fan Coil Unit complete with G.I. casing with bottom return Air Plenum (5mm PE insulation) or as per site requirement, Filter box with 8mm Nylon Filter, 3/4 Row Deep cooling coil with coper tube diameter is 9.52 mm and thickness 0.33 mm with hydrophilic Aluminium fins. An air vent in the coil must be provided. Complete coil must be designed for standard working pressure is 1.6 MPa (16bar) and the test pressure is 3.3MPa (33bar). Unit to be provided with SS drain pan with 5mm/10 mm PE insulation/OEM designed as required . Direct driven fan (three speed) motor/OEM Designed, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with electronic Thermostat having LCD and touch button. It has to based on microprocessor operations which can realize intelligent control of room temperature. ESP for the Fan Coil Unit be as per mentioned below, Else Specified. The Capacity calculation sheet for Heating application of unit should be in Line with ASHRAE/ Eurovent Standard for Fan Coil and to be approved by Consultant/Eurovent or ASHRAE Certified. OEM Should supply the capacity rating at all three speeds with as per required paramters of Site. The Cut outs to be made in ceiling as per the Machine for the Servicing purpose/Trape Door should be included in the price.Minimum Capacity at Hot Water Inlet : 60 Degree Celcius and Hot Water Outlet: 50 degree Celcius should be as follows :-

-

-

-

... More
(i) Unit to be provided with electronic Thermostat having LCD and touch button and 2 Way Valve. It has to based on microprocessor operations which can realize intelligent control of room temperature. It shall also have RS485 Modbus communication function or Bacnet for BMS control. (ii) Unit to be installed with Ball Valve/Butterfly Valve at Inlet and Oulet as per Pipe Diameter and Auto Air vent. The all accessiroes required for proprer fucntioning of unit should be included as per OEM recommendation. The desired U trap should be given as per the site Requirement.

-

-

-

... More
(a) 2.5 kW (External Static Pressure: 50 Pa) (Toilet Area - CHS Plant, Dinning Hall ) Reference Model - FWW200VC, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

1

-

-

... More
(b) 5 kW (External Static Pressure: 50 Pa) (Cook House, Plate Wash Area - Dinning Hall, CHS Plant Room, Study Room, 02 HAV's) Reference Model - FWW500VC, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

1

-

-

... More
(c) 6 kW (External Static Pressure: 50 Pa) (Servery - Dining Hall) Reference Model: FWW600VC, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

16

-

-

... More
(d) 12 kW (External Static Pressure: 100 Pa) (GF - Toilet Area, Passage, 20 Ors, FF- Passage) Reference Model : FUW015A, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

11

-

-

... More
(e) 18 kW (External Static Pressure: 100 Pa) (40 ORs), Reference Model: FUW020A, complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

8

-

-

... More
(f) 30 kW (External Static Pressure: 100 Pa) ( Corridor- Dinning Hall & Dinning Hall) Reference Model: FUW035A , complete all as specified and directed by Engr-in-Charge. Makes : Remote/Thermostat:Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI

8

-

-

... More
Pre - insulated MS pipe , Class 'C' having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 gauge GI cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temperature range of -50 Degree Celcius to 120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Makes: ZECO/Seven Star/Lloyd/Parma Pipe

-

-

-

... More
INSIDE BUILDING

-

-

-

... More
(a) 100 mm with 50 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

170

-

-

... More
(b) 80 mm with 50 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

400

-

-

... More
(c) 65 mm with 36 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

250

-

-

... More
(d) 40 mm with 36 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

250

-

-

... More
(e) 32 mm with 36 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
(f) 20 mm with 36 mm PUF thickness and 26 Gauge GI Cladding, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supply,Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping 25mm dia pipe, Insulation thickness - 19 mm complete with fittings (elbows, tees, reducers, sockets,U trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supply,Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping 32mm dia pipe, Insulation thickness - 19 mm complete with fittings (elbows, tees, reducers, sockets,U trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping 40mm dia pipe, Insulation thickness - 19 mm complete with fittings (elbows, tees, reducers, sockets,U trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply and installation of perforated painted with powder coating M.S. cable trays of size 150 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required at site, complete all as specified and directed by Engr-in-Charge.

300

-

-

... More
Supply, Installation, Testing Balancing and Commissioning of factory fabricated GSS rectangular/ round ducting thickness: 22 gauge Sheet of Hot dipped Galvanised with 120GSM Zinc coating including plenum as reuired at site as per IS 655 - 2006 complete with gaskets, elbows, splitters, vanes, supports adjustable dampers, etc. as per approved drawings. The price shall include necessary scaffolding required for working at required height.

1100

-

-

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 15 mm thick Supply and Application of Acoustic Insulation with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/Cum passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents, complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supply & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications, complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
Supply and fixing of Flexible connection Duct, complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply and fixing automatic Air Purger Valves for hot water circulation heade, complete all as specified and directed by Engr-in-Charge. Makes : Audco/C&R/Adverse/Anergy/MES approved supplier

20

-

-

... More
Supply and fixing of Air Separator of size 100 mm, complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing SITC of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Supply and fixing SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-100 C. Brass oil filled thermowell of 1/2" size as required by Engineer In Charge, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed Aluminium conductor armoured cable/unamoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray), complete all as specified and directed by Engr-in-Charge of size 3.5x630Sqm

60

-

-

... More
Supply & Laying/ fixing of 10 sq.mm x 4 Core size XLPE insulated and PVC sheathed copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray), complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply & Laying/ fixing of 6 sq.mm 4 Core size XLPE insulated and PVC sheathed copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray), complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply & Laying/ fixing of 2 X 2.5 sq.mm single Core size FCU insulated and PVC sheathed copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray), complete all as specified and directed by Engr-in-Charge. Note :- Two run of cable shall be measured as 1 Running Metre.

200

-

-

... More
Supply and fixing rubber matting conforming to IS-15652-2006 complete as required of size 2mx1mx 5 mm thickness, complete all as specified and directed by Engr-in-Charge.

16

-

-

... More
Supplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed. NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied and filled in central heating system pipe line after proper leakage test of entire circuit. The glycol water mixture ratio shall be 55:45 and freezing temperature shall be - 45° C (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe line Storage Tank, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
SCHEDULE `A' PART - VIII Section-II (External Water Supply) is not prepriced by MES and prepriced rates indicates 0.0 under column 7 signified this fact only.

-

-

-

... More
External Water Supply

-

-

-

... More
Supply , installation testing and commissioning step down 11/0.433 KV off load transformer, 3 Phase 4 wire AC, 50 cycles, 1250 KVA copper wound out door type with off load manual tap changing arrangments on HT side to vary secondary voltage upto ± 7.5% with step of ± 2.5% including suitable cable entry boxes on both side to receive HT XLPE cable complete in all respect with standard accessories and fitments conforming to IS-1180 level -III and IS 2026 Dy-11 connection complete all as specified and directed. Salient features of transformers shall be as under :- (a) Transformer shall be oil immersed, naturally/self cooled, double wounded, coper winding, core type, MSD radiatior cooled tank complete with first fill of transformeroil as per IS : 335 with test certificates with ON/AN cooling system, temparature of oil shall not rise beyond 55oCto am,blent and 55oC of windiong. Transformer shall be painted with two coats of smpoke gray epoxy paint conforming to IS : 632. (b) Rating and diagram plate. (c) Earthing terminal two Nos (d) Lifting lugs (e) Thermameter pocket including suitable thermometer (f) Air release valve with plug (g) Winding temperature/Oil temperature indicator housed in a separate box for control wiring (h) Conservator with oil indicator (j) Mild steel castors with locking provision (k) Silca breather Gel assembly with first filling of coper sulphate Note : Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with m4 grade or better

1

-

-

... More
Supplying, installation, testing and commissioning of cubical type wall / floor mounted Distribution Panel suitable for Indoor application for 415V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick , i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable Amp capacity extensible type Copper bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 50kA, the bus bar spacing Ph-Ph, Ph-N, Ph-body/Earth shall be designed for altitute 3500 mtrs the design shall be approved by Engineer in Charge with Entire panel shall have a common earth bus of suitable size at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of aluminium bus bars 2500 Amp rated and control panel wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alloys, cable gland plates. providing & fixing following switch gears:- Incomming (a) MCCB microprocessor based, 415 Volt, 4 pole 400 Amp 36 KA -01 No (b) Digital multi functional panel meter showing volt, frequency, PF along with CTs - 01 set (c) Indicator lamp LED type RYB - 01 Set Outgoing (a) 40 A 10 KA MCB 4 pole - 02 Nos (For Glycol centrifugal Pumps) (b) 315 A 36 KA MCCB microprocessor based, 415 volts, 4 pole -02 Nos (Heater for storage Tank). (c) 63 A 25 KA MCCB microprocessor based, 415 volts, 4 pole-03 Nos (Heater for UG Storage Tank) (d) 40A 10 KIA MCB SPN-06 Nos (Tracer element, circulation pumps) All conection shall be made through spreader link between bus bar and ACB/MCCB, complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supplying, installation, testing and commissioning of cubical type wall / floor mounted Distribution Panel suitable for Indoor application for 415V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick , i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable Amp capacity extensible type Copper bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 50kA, the bus bar spacing Ph-Ph, Ph-N, Ph-body/Earth shall be designed for altitute 3500 mtrs the design shall be approved by Engineer in Charge with Entire panel shall have a common earth bus of suitable size at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of aluminium bus bars 2500 Amp rated and control panel wiring with 1.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alloys, cable gland plates. providing & fixing following switch gears:- Incomming (a) MCCB microprocessor based, 415 Volt, 4 pole 400 Amp 36 KA -01 No (b) Digital multi functional panel meter showing volt, frequency, PF along with CTs - 01 set suitable ratio (c) Indicator lamp LED type RYB - 01 Set Outgoing (a) 40A 10KA MCB 4 pole -02 Nos (For Glycol Centrifugal Pumps) (b) 315A 36 KA MCCB microprocessor based, 415 Volts, 4 pole- 02 Nos (Heater for Storage Tank) (c) 63A 25KA MCCB microprocessor bases, 415 volts-03 Nos (Heater for UG Storage Tank) (d) 40A 10KA MCB SPN - 06 Nos (Tracer element, circulation pumps) All connection shall be made through spreader link between bus bar and ACB/MCCB, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
SCHEDULE `A' PART - IX Section-II (External Electric Supply) is not prepriced by MES and prepriced rates indicates 0.0 under column 7 signified this fact only.

-

-

-

... More
External Electric Supply

-

-

-

... More
Providing tracer / antifreezing cable required to keep the pipe warm to avoid freezing of GI and DI pipe , complete all as specified and directed by Engr-in-Charge.

114

-

-

... More
Construction of new brick masonary valve pit chamber of size 600x600x900mm (Internal size) with 230 mm thick brick wall in CM (1:4), 15mm plastering on internal & external surfaces in CM (1:4), 75mm thick PCC(1:4:8) type D-2 using 40mm graded crushed stone aggregate including MS sheet cover 3mm thick hinged with 40x40x6mm MS angle iron frame having locking arragements. Cover is painted with two coat of synthetic enamel paint over one coat of red oxied primer including necessary earth work and removal of surplus soil to a distance n.exc. 50m and deposited, complete all as specified and directed by Engr-in-Charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.