National Institute For Interdisciplinary Science And Technology Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
National Institute For Interdisciplinary Science And Technology - NIIST Tender
Eprocure
Opening Date6 May 2024
Closing Date14 May 2024
Tender Amount₹ 16,37,510
Costs
EMD
₹ 32,750Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_194953_1Bid Award Id
ViewTender No
NIIST/WKS/013/NIT(2-1)/2024-25Tender Authority
National Institute For Interdisciplinary Science And Technology ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Four Quartely servicing and maintenance of Multi Split Air conditioners of 2 Tr/ 3 TR capacity of various makes like, Voltas, Bluestar, carrier, Videocon, Usha etc. Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
4
-
-
Four Quartely servicing and maintenance of cassette type Split Air conditioners of 1Tr/2 Tr capacity of various makes like, Voltas, Bluestar, carrier, Videocon, Usha etc. Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
4
-
-
Four Quartely servicing and maintenance of Slim line Air conditioners of 3/4 TR capacity of Voltas, make . Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
7
-
-
Four Quartely servicing and maintenance of Ductable Split Air conditioners of various capacities as follows . Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
-
-
-
3 TR Carrier make
10
-
-
5 TR Carrier make
1
-
-
5.5 TR Carrier,Blue star, Hitachi make
7
-
-
8.5 TR Carrier,Blue star make
4
-
-
Four Quartely servicing and maintenance of Packaged Air conditioners of various capacities as follows . Attend to all breakdown calls or performance related complainte. Rate should be quoted for yearly basis.
-
-
-
11 TR ETA/Zeco/Carriermake (Twin circuit of 5.5 TR with Horizontal AHU type)
4
-
-
16.6 TR ETA make (Twin circuit of 8.5 TR with Horizontal AHU type)
4
-
-
Four Quartely sevicing and maintenance of Cold Room 1.0/2 TR
1
-
-
PART-B Supply, Installation,Replacing of Spares/Works as and when required basis - Part B-1 For Window & Split Acs
-
-
-
Supply and installation of new sealed unit compressors for window mounting/Split/Multi split air conditioners of 1.5 TR/2TR of Reciprocating/Rotary as and when/which required
10
-
-
Gas (Refrigerant R22/R32/410A) charging of 1.5 TR/2TR windows mounting air conditioners of various makes after welding , system flushing with nitrogen, leak testing, evacuation including all material cost and labour charges etc. complete , as when required.
2
-
-
Gas (Refrigerant - R22/R32/R410a) charging of 1.5TR/2TR Split air conditioners of various makes after welding , system flushing with nitrogen, leak testing, evacuation including all material cost and labour charges etc. complete as and when required.
20
-
-
Gas (Refrigerant - R22/R32/R410a) charging of 1TR/2TR cassette type Split air conditioners of various makes after welding , system flushing with nitrogen, leak testing, evacuation including all material cost and labour charges etc. complete as and when required.
1
-
-
Gas (Refrigerent ) charging of 3 and 4 TR Slim line air conditioners after welding, system flushing with nitrogen, leak testing, evacuation including all matetrial cost and labour charges etc. complete as and when required.
2
-
-
Shifting and Re-installation of spli/Multi split Air conditioners with in the Lab.Rooms/Camplus including Civil work if required.
7
-
-
Copper tubing for the above1/4'' & 1/2'' ( or which ever is suitable size to the unit ) with insulation etc complete.
50
-
-
supply & replacing of Condensing Unit Stand
5
-
-
Condenser Fan motor Rewinding, over-hauling , bush replacement and re fixing etc. complete of window units/split Units, as and when required.
10
-
-
Blower Fan motor bush repalcement , servicing and re-fixing etc for split units, as and when required.
10
-
-
Sevicing and rectification of cordless remote controller PCBs of split Ac as and when required.
6
-
-
Supply , fixing & commissioning of new condensing fan motor for split AC as and when required.
6
-
-
Supply, fixing & commissioning of new blower fan motor for split AC as and when required.
6
-
-
Supply , Installation & commissioning of New condensing units with copper coil without compressor of 1.5/2TR as and when required.
3
-
-
Supply , Installation & commissioning of New Indoor units with copper coil of 1.5/2TR as and when required.
3
-
-
Supply & Installation of New condenser copper coils 1.5/2TR split units (replacing of Aluminium Coil) as and when required.
5
-
-
Replaccing/Repairing/fabricationg of sheet metals of Bottom plate and fan mounting plates of condensing units, including painting of the same
5
-
-
Supply and fixing of angle Iron fabricated condenser unit stand as per site condition /Engineer Incharge choice
20
-
-
Supply and laying of closed cell nitrile rubber Insulation for existing refrigent tubes and wrapping heat resistance (white) tape on it.
50
-
-
Supply and fixing of spare parts for windows units and split units, as and when required.
-
-
-
Fan motor capacitor
20
-
-
Starting capacitor
15
-
-
Running Capacitor
30
-
-
Starting Relay
5
-
-
Thermostat
1
-
-
Swing motor for split Acs
5
-
-
Air filter Fiber
5
-
-
Air Filter Fiber for spli Unit
10
-
-
condenser fan leaf
10
-
-
Blower Fan
2
-
-
Replacement of remote control unit (cordless ) with signal receiver
7
-
-
Contactor for 2TR single phase compressor
4
-
-
Contactor for multi split A/Cs condenser fan
4
-
-
Temp Sensor Air
10
-
-
Temp Sensor coil
10
-
-
PART-B Supply, Installation,Replacing of Spares/Works as and when required basis - PART - B-II For Ductable units 3,5,5.5 & 8.5 TR units
-
-
-
Supply and fixing of the following Genuine spare parts whenever necessary
-
-
-
Contactor for compressor
10
-
-
Single Phase Preventer with Under Voltage & Over voltage cut out, Phase failure and phase reversal cut out
2
-
-
Microprocesor based Controlling unit
2
-
-
Temp sensor For Microprocessor
6
-
-
Compressor for 3TR (1.5 + 1.5) unit 1.5TR Rotary Compressor
4
-
-
Liquid line filter / Drier
2
-
-
Condenser fan Leaf
2
-
-
V belts for IDUs
2
-
-
Blower Fan motor Rewinding , over hauling , and Refixing etc complete whenever required.
2
-
-
Condenser fan motor Rewinding, over-hauling, and refixing etc complete as and when required
3
-
-
Gas ( Refrigerant ) charging of 3TR air conditioners of Carrier make after welding , system flushing with nitrogen , leak testing , evacuation & recommissioning, including all material cost and labour charges etc. complete, as and when required. Twin system and hence rate may be quoted for 1.5
4
-
-
Gas(Refrigerant) charging of 5.5TR air conditioners of carrier/Blue star make after welding,system flushing with nitrogen, leak testing , evacuation & recommissioning , including all material cost and labour charges etc. complete, as and when required.
4
-
-
Gas (Refrigerant) charging of 8.5 TR/8.3TR air conditioners of variousof Carrier/Blue star after welding , system flushing with nitrogen, leak testing, evacuation including all material cost and labour charges etc. complete , as when required.
2
-
-
Supply and fixing of the following Genuine spare parts whenever necessary
-
-
-
60x30.5x50 cm Box type prefilter for ZECO AHU 90% down to 10 Micron
1
-
-
61x61x50 cm Box type prefilter for ZECO AHU 90% down to 10 Micron
1
-
-
61x61x50 cm Box type prefilter for ZECO AHU 99% down to 5 Micron
1
-
-
60x30.5x50 cm Box type prefilter for ZECO AHU 90% down to 5 Micron
1
-
-
Supply & replacing of Condenser deck (Condenser mounting plate) for carrier make 3TR units
4
-
-
PART-B Supply, Installation,Replacing of Spares/Works as and when required basis - PART - B-III For Packaged/AHU type units
-
-
-
Supply and fixing of the following spare parts (original) whenever necessary
-
-
-
contactor for compressor (siemens 3TF33)
4
-
-
contactor for blower motor (siemens 3TF31)
2
-
-
Overload relay for compressor (siemens 3UA52 16-25A)
2
-
-
Overload relay for fan motor (siemens 3UA50 6-10A)
2
-
-
Under Voltage & over voltage cut out and phase failure and phase reversal cut put ( Make -Minilec - S2VMR3)
2
-
-
Microprocesor based Controlling unit carrier /ETA makes
4
-
-
Temp sensor For Microprocessor
10
-
-
"v" Belts
10
-
-
Bearings for Blower mounting
2
-
-
Shaft for blower
3
-
-
Liquid line filter/drier
4
-
-
AHU Fan motor Rewinding , over-hauling , and Re-fixing atc complete as and when required.(5 HP, 3HP motor)
4
-
-
Condenser fan motor Rewinding, over-hauling, and refixing etc complete as and when required
2
-
-
Gas (Refrigerant ) charging of 11TR (5.5 Twin Compressors with individual Ref Circuit ) air conditioners . After welding, syystem flushing with nitrogen , leak testing , evacuation & recommissioning , including all material cost and labour charges etc. complete , as and when required.Twin system and hence rate may be quoted for 5.5 TR only .
2
-
-
Gas (Refrigerant ) charging of 16TR (8.3 Twin Compressors with individual Ref Circuit ) air conditioners . After welding, syystem flushing with nitrogen , leak testing , evacuation & recommissioning , including all material cost and labour charges etc. complete , as and when required.Twin system and hence rate may be quoted for 8.3 TR only .
4
-
-
Fabrication & Installation of Standard Electrical Controll pannel for 16.6 Tr Twin circuit Horizontal AHU roof top Packaged Unit with minimum Size of 700 mm X 450 mm x200 mm including L & T FN 100A Main Switch, 415V . (The drawing of the pannel should be approved by Eng Incharge before Fabrication)
3
-
-
Removing old Controller pannel & Installation of New supplied panneand by Utilizing the components such as Controller Contactor, relays, including termination Glands etc complete
3
-
-
Supply & Replacing of double skin insulated Bottom pannel of 50 mm thick for ETA make AHU=CTA-008 (16.6TR Horizontal Mount ) it includes system disconnection after proper pumpdown /reconnection of the same and Duct mouths etc complete if necessary
4
-
-
Replaccing/Repairing/fabricationg of sheet metals of Bottom plate and fan mounting plates of condensing units of 5.5 TR Units, including painting etc complete
6
-
-
PART-B Supply, Installation,Replacing of Spares/Works as and when required basis - PART - B-IV For Cold Rooms
-
-
-
Four Quartely servicing and maintenance of cold rooms 1.5 TR/ 2TR capacity (4 Deg C) of makes like Voltas, Carrier, L.G., Bluestar, Videcon, Usha etc. Attend to all breakdown calls or performance related complaints. Rate should be quoted for yearly basis.
1
-
-
Replacement of Evaporator fan motor with leafs
1
-
-
Replacement of Condenser fan motor with leafs
1
-
-
Gas (Refrigerent) charging of 1.5TR/2TR cold rooms flushing with Nitrogen , leak testing , evacuation including all material cost and labour charges etc. complete, as and when required.
1
-
-
PART-B Supply, Installation,Replacing of Spares/Works as and when required basis - PART - B-V For Refrigerators/DeepFreezers etc
-
-
-
Exchanging defective compressors with new one, installation , welding , leak testing, evacuation and gas charging, etc. complete for all models, as and when required.
2
-
-
Cost of refrigerent, welding, ;abour charge , etc. complete for gas charging after evacuation of the system of all models, as and when required.
2
-
-
Spare parts ( original ) supply and replacement , as and when required.
-
-
-
Relay
4
-
-
Thermostat
4
-
-
Bulb
6
-
-
OLP
6
-
-
Capacitors
2
-
-
Timer for non frost refrigerator
4
-
-
Heater for non frost refrigerator
4
-
-
Fan motor with fan leaf for Frost free Refrigerator
4
-
-
Supply & installation of compressors of various capacity refrigerator , as and when required.
4
-
-
Gas charging after testing and evacuation including cost of materials and labour charges, etc. complete, as and when required.