National Centre For Earth Science Studies Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

National Centre For Earth Science Studies - NCESS Tender

Works
Eprocure
Opening Date1 Apr 2021
Closing Date26 Apr 2021
Tender AmountRefer Documents 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Renovation of room for installation of wet labs
Renovation of room for installation of wet labs
Renovation of room for installation of wet labs
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Fabrication, installation, Erection and testing of Volume Control Dampers: Suitable dampers Powder /FRP coated to be installed in AHU to regulate the quantity of airflow-in supply and return air ducts.

2

-

7951

... More
Supply, Fabrication, installation, Erection and testing of Fresh air intake Louvre: Appropriate Aluminum finish air intake louvre with volume control damper and 20-micron pre filter, By pass Damper and variable Frequency Drive to be provided for adjusting AHU Motor speed during idle hours, evenings & week ends.

1

-

11363

... More
Supply, Fabrication, installation, Erection and testing of Fire Damper with actuator: Appropriate fire damper with actuator. In case of fire the fire alarm should close the actuator Actuators, Control Panel & Wiring. the damper and the AHU

2

-

19095

... More
Supply, Fabrication, installation, Erection and testing of return air grille with VCD

2

-

8480

... More
Supply, Fabrication, installation, Erection and testing Control Panel with all Cable upto 40-meter, Distribution Board. The electrical connections should be complete with D B, MCBs, Wiring, Plug, Light switches etc, LAN points, Telephone points, Standard modular switches, Plug and sockets of 15/ 5 A with three socket each (with relevant Indian Standards.) etc should be installed at locations specified by the User.

1

-

200000

... More
ESD EPOXY FLOORING  CIVIL WORK Apply a coat of solvent free best quality approved epoxy primer and allowing it to become dry. Apply solvent free, roller applied epoxy of best quality and approved colour, epoxy coating (two coats or more coats) to 2 mm ESD and allow to full cure. Allow entire system to air cure for a period of 24 hours before putting to foot traffic etc including all labour, materials and conveyance charges etc as directed by Engineer in Charge including skirting for 75 mm height on wall. NOTE:- The thickness of Epoxy coating should be measured by using Elcometer 500 concrete coating thickness gauge and got approved by Engineer in Charge.

50

-

1400

... More
Supply and installation of False Ceiling 60 mm Thick non-metallic. False ceiling with 3 mm high Pressure laminates on both sides smooth finish PUF density should be 40 Kg/Cu.M. The false ceiling should be aptly supported (nonmetallic support) from the RCC roof as directed by Engineer in Charge. It is made of non-metal. cost include of all cut outs for filters and lighting should be made in the false ceiling including all labour, materials, scaffolding charges etc complete.

70

-

4500

... More
Finishing with Epoxy Paint (two or more coats) at all locations prepared and applied as per manufactures specification including appropriate priming coat, preparation of surfaceCleaning ofExisting walls and applying epoxy paint 2 coats upto 100 micron thickness including all labour, materials, scaffolding charges etc. complete.

200

-

189.4

... More
Supply, erection, testing and commissioning of clean room compatible light fittings recess mounting type 20/24 watts LED all as specified And/or directed etc., complete.

20

-

7000

... More
BrickworkwithcommonburntclayF.P.S.(nonmodular) bricksofclassdesignation7.5in Superr structure Cementmortar1:6(1cement: 6coarsesand)

5

-

6157.45

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length Second Class Teak Wood frame of 0.05size 2.10 M X 0.10M X 0.07 M including painting with ready mixed wax polish of approved brand & manufacture

0.05

-

105327.2

... More
Providing and fixing wooden door (side towards the lab to be covered with acid proof laminate) with View panels (450 X750 mm) (toughen glass) doors withy hinges, non-metallic handle, powder coated door closer etc with all necessary fittings including all conveyance labour charges etc complete including painting with ready mixed wax polish of approved brand & manufacture

10

-

2770.4

... More
Supplying and fixing woodenwork table (Heavy top covered with acid proof laminate) of required size and shape as per users requirement and specifications for lab use.

3

-

10000

... More
Supplying and fixing wooden storage racks covered with formica as directed by the user including all material, labour and conveyance charges etc complete as directed by the user.

20

-

700

... More
Supplying and fixing of Poly Propylene/ PVC/ Laboratory sink of size 600l X 350WX225 mm with all necessary fittings (PP/PVC), drain out let (PP/PVC) etc complete as per User’s requirement. The connections from tanks to the lab to be carried out using PVC/PP pipes

1

-

11000

... More
Providing and fixing Wall mounted Temperature and Relative Humidity equipment including all conveyance charges as directed by user

1

-

8000

... More
Supplying and fixing Room Pressure gauge in the form of Mangehelic gages for measuring and indicating change in room pressure, including all labour, material and conveyance charges etc complete as per User requirement.

1

-

4000

... More
Supplying and fixing fire detector alarm as per fire and safety standards including all labour, material and conveyance etc complete. Fire Detector And Alarm Specification includes Supply,Warranty,Installation,TestingandC ommissioningandintegrationoftheFireAlar mSystemmainlyconsisting of the Fire Alarm Control Panel(FACP),loop driver cards, Repeater Panel, Detectors and associated Testing kit, for performing the major functions as below: i)Detection of fire in its incipient stage and give an audio-visual annunciation at specified locations/backup location with quick and exact identification of the fire location as well as operate auxiliary devices as programmed. ii) Supervise and monitor all Analogue addressable detectors for normal, trouble and alarm conditions. iii) Display information associated with the fire alarm condition, including type and location within the protected premises. Detectors:The detectors shall be Analogue Addressable type and suitable for connection to the control panel via a two-wire loop circuit (class A wiring).Its hall have dual alarm and power LED’s, which shall flash under normal conditions, indicating that the detector is operational and in regular communication with the control panel. Both LED’s shall be placed into steady illumination mode by the control panel, indicating that an alarm condition has been detected. An output connection shall also be provided in the base to connect an external remote alarm/response LED. Compatible Plug in type bases shall be supplied with all the detectors, MCPs, sounders etc. The bases shall be equipped with field terminals capable of securing field wire sizes up-to 1.5 sqmm. Fire Alarm Control Panel:The Networked Intelligent Addressable Fire Alarm Control Pane l(FACP) shall consist of 3nos. of addressable Loop driver cards, Communication card for repeater panel located at around 500meterdistance,TCP/IP Networkcard,240VACpowersupply input and in-built battery backup. The capacity of battery (AH) shall be selected so as to operate the Fire alarm system control panel, repeater panel, detectors and other components for 24 hours in stand by mode plus 30 mins. in alarm mode. 1.TheFireAlarmControlPanelshallhaveaoperator interface control and annunciation panel with a backlit liquid crystal display, individual colour coded system status LED’s, and an alpha numeric key pad for the field programming and control of the fire alarm system. The FACP shall control and communicate with the addressable detectors, addressable modules, repeator panel, annunciators and other system controlled devices like Audio Alarm hooter, Fire Contact output and Alarm output

1

-

1058

... More
Installation of the existing Laminar flow 1 no 1500 LX600mm D X750 mmH and Laminar flow fume hoods 3 nos 1500 LX600 DX 750 H in wet labs as specified by the user

4

-

2000

... More
12 mm cement plaster 1 :4 for Brick Masonary work

25

-

172.95

... More
Supplying and closing the existing window openings with 5.5 mm thick toughened glass panel including all fixtures, labour and conveyance charges etc complete

7

-

1500

... More
Providing and fixing Polyvinyl Chloride (PVC) pipes, all PVC plain fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia pipe Conditions 1 Warranty: material and working warranty for 3 years 2 The lab should be compatible to the present Class 10,000 clean lab at NCESS 3 The supplier should have prior experience of making clean lab or a wet lab associated with clean lab (for clean chemistry) using high pressure laminates (HPL) at CSIR/DST/MoES/DOS National R & D institutes or IIT, IISER etc. The details of such works to be provided. 4 The make, model and its detailed specification, list of items must be clearly specified.

20

-

30

... More
CI 35.59%

0.36

-

438754

... More
Contingencies 5%

0.05

-

1395507



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.